A complementary method to determine the vibration source intensity,defined as the weighted vertical acceleration level at the tunnel wall,is needed urgently when comparable measurements or database predictions are una...A complementary method to determine the vibration source intensity,defined as the weighted vertical acceleration level at the tunnel wall,is needed urgently when comparable measurements or database predictions are unavailable in empirical predictions.In this study,we present an analytical model designed to quickly and accurately estimate the vibration source intensity produced by moving metro trains,considering both regular and floating slab tracks.The improved periodic pipe-in-pipe(PiP)model with regular or floating slabs affixed to the tunnel invert was developed.The train loads are represented in the frequency-wavenumber domain to apply in the model.Measured track irregularities were applied and the proposed model was validated against the measured results and verified by a tunnel-soil coupled model.The proposed approach effectively and accurately assessed the vibration source intensity generated by underground trains in a prediction time of just 58 s.Track irregularities significantly affect the vibration source intensity,making them a key factor in comparable measurements or database predictions.A floating slab track can reduce the vibration source intensity by about 14 dB.The proposed approach can serve as an additional method to complement comparable measurements or database predictions for determining the vibration source intensity in empirical predictions.展开更多
In order to accommodate higher speeds,heavier axle weights,and vibration damping criteria,a new floating slab structure was proposed.The new type of floating slab track structure was composed of three prefabricated fl...In order to accommodate higher speeds,heavier axle weights,and vibration damping criteria,a new floating slab structure was proposed.The new type of floating slab track structure was composed of three prefabricated floating slabs longitudinally interconnected with magnesium ammonium phosphate concrete(MPC).This study investigated the dynamic performance of the structure.We constructd a full-scale indoor experimental model to scrutinize the disparities in the impact performance between a longitudinally connected floating slab track and its longitudinally disconnected counterpart.Additionally,a long-term fatigue experiment was conducted to assess the impact performance of longitudinally connected floating slab tracks under fatigue loading.The findings are described in the following.1)The new structure effectively suppresses ground vibrations,exhibiting a well-balanced energy distribution profile.However,the imposition of fatigue loading leads to a reduction in the damping performance of the steel spring damping system,thereby reducing its capacity to attenuate structural vibrations and leading to an increase in ground vibration energy;2)After 107 loading cycles,the attenuation rate of the vibration acceleration for the MPC increases by 171.9%.Conversely,at the corresponding disconnected location,the attenuation rate of ground vibration acceleration decreases by 65.6%.In conclusion,longitudinally connected floating slab tracks exhibit superior vibration reduction performance.While the vibration reduction performance of longitudinally connected floating slab tracks may diminish to some extent during long-term service,these tracks continue to meet specific vibration reduction requirements.展开更多
To improve the low-frequency vibration reduction effect of a steel spring floating slab track(FST),nonlinear quasizero-stiffness(QZS)vibration isolators composed of positive stiffness elements(PSEs)and negative stiffn...To improve the low-frequency vibration reduction effect of a steel spring floating slab track(FST),nonlinear quasizero-stiffness(QZS)vibration isolators composed of positive stiffness elements(PSEs)and negative stiffness elements(NSEs)were used to support the FST.First,considering the mechanical characteristics of the nonlinear QZS vibration isolators and the dynamic displacement limit(3 mm)of the FST,the feasible parameter groups were studied with the nonlinear stiffness variation range and bearing capacity as evaluation indices.A vertical vehicle quasi-zero-stiffness floating slab track(QZS-FST)coupled dynamic model was then established.To obtain a reasonable nonlinear stiffness within a few millimeters,the original length of the NSEs must be analyzed first,because it chiefly determines the stiffness nonlinearity level.The compression length of the NSEs at the equilibrium position must be determined to obtain the low stiffness of the floating slab without vehicle load.Meanwhile,to meet the dynamic displacement limit of the FST,the PSE stiffness must be increased to obtain a higher stiffness at the critical dynamic displacement.Various stiffness groups for the PSEs and NSEs can provide the same dynamic bearing capacity and yet have a significantly different vibration reduction effect.Excessive stiffness nonlinearity levels cannot effectively improve the vibration reduction effect at the natural frequency.Furthermore,they also significantly amplify the vibrations above the natural frequency.In this paper,the vertical vibration acceleration level(VAL)of the floating slab and the supporting force of the FST can be decreased by 6.9 dB and 55%,respectively,at the resonance frequency.展开更多
Low frequency vibrations induced by underground railways have attracted increasing attention in recent years. To obtain the characteristics of low frequency vibrations and the low frequency performance of a floating s...Low frequency vibrations induced by underground railways have attracted increasing attention in recent years. To obtain the characteristics of low frequency vibrations and the low frequency performance of a floating slab track (FST), low frequency vibration tests on an FST in an underground laboratory at Beijing Jiaotong University were carried out. The FST and an unbalanced shaker SBZ30 for dynamic simulation were designed for use in low frequency vibration experiments. Vibration measurements were performed on the bogie of the unbalanced shaker, the rail, the slab, the tunnel invert, the tunnel wall, the tunnel apex, and on the ground surface at distances varying from 0 to 80 m from the track. Measurements were also made on several floors of an adjacent building. Detailed results of low frequency vibration tests were reported. The attenuation of low frequency vibrations with the distance from the track was presented, as well as the responses of different floors of the building. The experimental results could be regarded as a reference for developing methods to control low frequency vibrations and for adopting countermeasures.展开更多
The extensive use of steel spring floating slab tracks has effectively addressed the challenge of alleviating the environmental vibrations induced by urban rail transit systems.However,under the combined action of tra...The extensive use of steel spring floating slab tracks has effectively addressed the challenge of alleviating the environmental vibrations induced by urban rail transit systems.However,under the combined action of train dynamic loads and complex environmental factors,problems,such as the fracture of steel spring vibration isolators and suspension vibrations induced by the uneven settlement of the base,often occur.The failure of isolator support stiffness is often hidden in its early stages and is challenging to identify by conventional detection methods.At the same time,it will aggravate the wheel-rail interaction,accelerate the deterioration of track structure,and even affect the driving safety.This study first establishes a detailed coupled train-floating slab track-foundation analytical model.Then the influence of the vibration isolator support stiffness failure on the dynamic indices of the floating slab track system response is analyzed.A set of defect identification methods that can detect the number of failed steel springs,severity of damage,and their location is proposed.Finally,an intelligent monitoring system for support stiffness of floating slab track is built by combining the density-based spatial clustering of applications with noise algorithm and statistical data analysis and is applied to a rail line in southern China.During a three-year monitoring campaign,a suspension failure and a fracture of a steel spring were each successfully detected and detailed failure information was obtained.Field investigation results were consistent with the damage identification results.After repair,the track structure dynamic response returned to the average pre-damage level and further deterioration had been arrested.The proposed damage identification methods and monitoring system provide an approach for intelligent identification of track structure support stiffness failures.展开更多
In actual line operation,the critical velocity is one of the key physical quantities of rail design owing to its great infuence on the riding comfort and safety of vehicles due to the wheel-rail contact loss caused by...In actual line operation,the critical velocity is one of the key physical quantities of rail design owing to its great infuence on the riding comfort and safety of vehicles due to the wheel-rail contact loss caused by the abrupt change of rail foundation rigidity,rail wear,or abruptness irregularities on rail.In this study,the short floating slab track(SFST)structure is regarded as a double-layer system.The Euler beam and the rigid body model are adopted for the rail and the floating slab,respectively.and the dispersion equation and the theoretical critical velocity of the rail structure under ideal conditions are deduced.Besides,this st udy considers the implementation of the SFST in the vehicle-structure coupling system.The alterable element method is introduced for accurately simulating the change of the whee-rail contact state and coding a vehicle-structure dynamic analysis program(VSDAP)to calculate the critical velocity of rail structures from the dynamic response of vehicles and rail structures.The principle of its design at the beginning of the design is given on the basis of the theoretical value of the critical velocity and the simulation of the dynamic response,which can provide reference for practical engineering design.展开更多
Virtual simulation teaching is an addendum to the experimental teaching mode of railway engineering,and the two teaching methods complement each other and merge with each other.In view of the current research,there is...Virtual simulation teaching is an addendum to the experimental teaching mode of railway engineering,and the two teaching methods complement each other and merge with each other.In view of the current research,there is little discussion about the integration path of the two above.Based on the connotation and design of virtual simulation teaching,this research systematically expounds the integration of the real path and path optimization problems,and puts forward the railway engineering experimental teaching principles based on virtual simulation teaching.On the basis of this research,a virtual simulation experiment platform for vibration mechanics and its application in the floating slab vibration damping track was developed to make full use of three-dimensional modeling,virtual reality,human-computer interaction and other technologies,which can realistically simulate the vibration law and vibration damping effect of the rail transit system,and in the hope that the virtual simulation teaching can be widely used in the experimental teaching mode of railway engineering in the future.展开更多
Underground railway vibration source strength is one of the key values used for environmental impact assessment and the evaluation of mitigation measure’s performance.However,currently there is no international stand...Underground railway vibration source strength is one of the key values used for environmental impact assessment and the evaluation of mitigation measure’s performance.However,currently there is no international standard of measuring the underground railway vibration source strength for such purposes.The available local standards and industrial guidelines do not agree on measurement locations as well as the metrics for presenting the source strength.This has caused many confusions.This paper aims to study the suitable measurement location and metrics using the data from a large scale field-testing carried out at the Nanchang underground railway(Metro Line 1,China)in 2017.200 passing trains were recorded during the test at two different sections of the railway line,one with the spring floating slab installed and the other without.Three locations were chosen at each section,including one in the middle of the track and two on the tunnel wall at different heights.Based on the results of statistical analysis,the maximum of z-weighted vertical vibration level(VLzmax)obtained at a lower measurement location on the tunnel wall is the best for representing the underground railway vibration source strength,which is 76.66 dB obtained from this study.展开更多
基金supported by the Natural Science Foundation of Shandong Province of China(No.ZR2024QE071).
文摘A complementary method to determine the vibration source intensity,defined as the weighted vertical acceleration level at the tunnel wall,is needed urgently when comparable measurements or database predictions are unavailable in empirical predictions.In this study,we present an analytical model designed to quickly and accurately estimate the vibration source intensity produced by moving metro trains,considering both regular and floating slab tracks.The improved periodic pipe-in-pipe(PiP)model with regular or floating slabs affixed to the tunnel invert was developed.The train loads are represented in the frequency-wavenumber domain to apply in the model.Measured track irregularities were applied and the proposed model was validated against the measured results and verified by a tunnel-soil coupled model.The proposed approach effectively and accurately assessed the vibration source intensity generated by underground trains in a prediction time of just 58 s.Track irregularities significantly affect the vibration source intensity,making them a key factor in comparable measurements or database predictions.A floating slab track can reduce the vibration source intensity by about 14 dB.The proposed approach can serve as an additional method to complement comparable measurements or database predictions for determining the vibration source intensity in empirical predictions.
基金Project(2022-Major-14)supported by the Science and Technology Research and Development Program Project of China Railway Group Limited。
文摘In order to accommodate higher speeds,heavier axle weights,and vibration damping criteria,a new floating slab structure was proposed.The new type of floating slab track structure was composed of three prefabricated floating slabs longitudinally interconnected with magnesium ammonium phosphate concrete(MPC).This study investigated the dynamic performance of the structure.We constructd a full-scale indoor experimental model to scrutinize the disparities in the impact performance between a longitudinally connected floating slab track and its longitudinally disconnected counterpart.Additionally,a long-term fatigue experiment was conducted to assess the impact performance of longitudinally connected floating slab tracks under fatigue loading.The findings are described in the following.1)The new structure effectively suppresses ground vibrations,exhibiting a well-balanced energy distribution profile.However,the imposition of fatigue loading leads to a reduction in the damping performance of the steel spring damping system,thereby reducing its capacity to attenuate structural vibrations and leading to an increase in ground vibration energy;2)After 107 loading cycles,the attenuation rate of the vibration acceleration for the MPC increases by 171.9%.Conversely,at the corresponding disconnected location,the attenuation rate of ground vibration acceleration decreases by 65.6%.In conclusion,longitudinally connected floating slab tracks exhibit superior vibration reduction performance.While the vibration reduction performance of longitudinally connected floating slab tracks may diminish to some extent during long-term service,these tracks continue to meet specific vibration reduction requirements.
基金Project supported by the National Natural Science Foundation of China(Nos.5197858351425804+2 种基金51578468and 51608460)the Open Foundation of State Key Laboratory for Track Technology of High-speed Railway(No.2018YJ180)。
文摘To improve the low-frequency vibration reduction effect of a steel spring floating slab track(FST),nonlinear quasizero-stiffness(QZS)vibration isolators composed of positive stiffness elements(PSEs)and negative stiffness elements(NSEs)were used to support the FST.First,considering the mechanical characteristics of the nonlinear QZS vibration isolators and the dynamic displacement limit(3 mm)of the FST,the feasible parameter groups were studied with the nonlinear stiffness variation range and bearing capacity as evaluation indices.A vertical vehicle quasi-zero-stiffness floating slab track(QZS-FST)coupled dynamic model was then established.To obtain a reasonable nonlinear stiffness within a few millimeters,the original length of the NSEs must be analyzed first,because it chiefly determines the stiffness nonlinearity level.The compression length of the NSEs at the equilibrium position must be determined to obtain the low stiffness of the floating slab without vehicle load.Meanwhile,to meet the dynamic displacement limit of the FST,the PSE stiffness must be increased to obtain a higher stiffness at the critical dynamic displacement.Various stiffness groups for the PSEs and NSEs can provide the same dynamic bearing capacity and yet have a significantly different vibration reduction effect.Excessive stiffness nonlinearity levels cannot effectively improve the vibration reduction effect at the natural frequency.Furthermore,they also significantly amplify the vibrations above the natural frequency.In this paper,the vertical vibration acceleration level(VAL)of the floating slab and the supporting force of the FST can be decreased by 6.9 dB and 55%,respectively,at the resonance frequency.
基金Project supported by the National Natural Science Foundation of China (No. 51008017)the Fundamental Research Funds for the Central Universities of China (Nos. 2009JBM074 and 2009JBM075)
文摘Low frequency vibrations induced by underground railways have attracted increasing attention in recent years. To obtain the characteristics of low frequency vibrations and the low frequency performance of a floating slab track (FST), low frequency vibration tests on an FST in an underground laboratory at Beijing Jiaotong University were carried out. The FST and an unbalanced shaker SBZ30 for dynamic simulation were designed for use in low frequency vibration experiments. Vibration measurements were performed on the bogie of the unbalanced shaker, the rail, the slab, the tunnel invert, the tunnel wall, the tunnel apex, and on the ground surface at distances varying from 0 to 80 m from the track. Measurements were also made on several floors of an adjacent building. Detailed results of low frequency vibration tests were reported. The attenuation of low frequency vibrations with the distance from the track was presented, as well as the responses of different floors of the building. The experimental results could be regarded as a reference for developing methods to control low frequency vibrations and for adopting countermeasures.
基金This work is supported by the National Natural Science Foundation of China(Nos.51978585 and 52008264)the Applied Basic Research Programs of Science and Technology Commission Foundation of Sichuan Province(No.2020YJ0214)+1 种基金the Foundation of High-speed Rail Joint Fund Key Projects of Basic Research(No.U1734207)the Foundation of National Engineering Laboratory for Digital Construction Evaluation Technology of Urban Rail Transit,China(No.2023JZ01).
文摘The extensive use of steel spring floating slab tracks has effectively addressed the challenge of alleviating the environmental vibrations induced by urban rail transit systems.However,under the combined action of train dynamic loads and complex environmental factors,problems,such as the fracture of steel spring vibration isolators and suspension vibrations induced by the uneven settlement of the base,often occur.The failure of isolator support stiffness is often hidden in its early stages and is challenging to identify by conventional detection methods.At the same time,it will aggravate the wheel-rail interaction,accelerate the deterioration of track structure,and even affect the driving safety.This study first establishes a detailed coupled train-floating slab track-foundation analytical model.Then the influence of the vibration isolator support stiffness failure on the dynamic indices of the floating slab track system response is analyzed.A set of defect identification methods that can detect the number of failed steel springs,severity of damage,and their location is proposed.Finally,an intelligent monitoring system for support stiffness of floating slab track is built by combining the density-based spatial clustering of applications with noise algorithm and statistical data analysis and is applied to a rail line in southern China.During a three-year monitoring campaign,a suspension failure and a fracture of a steel spring were each successfully detected and detailed failure information was obtained.Field investigation results were consistent with the damage identification results.After repair,the track structure dynamic response returned to the average pre-damage level and further deterioration had been arrested.The proposed damage identification methods and monitoring system provide an approach for intelligent identification of track structure support stiffness failures.
基金the National Natural Science Founda-tion of China(No.51675324)the Shanghai Founda-tion for University Key Teacher(No,ZZGCD15039)New Energy Vehicle Vibration and Noise Test and Control Professional Technical Service Platform(No.18DZ2295900)。
文摘In actual line operation,the critical velocity is one of the key physical quantities of rail design owing to its great infuence on the riding comfort and safety of vehicles due to the wheel-rail contact loss caused by the abrupt change of rail foundation rigidity,rail wear,or abruptness irregularities on rail.In this study,the short floating slab track(SFST)structure is regarded as a double-layer system.The Euler beam and the rigid body model are adopted for the rail and the floating slab,respectively.and the dispersion equation and the theoretical critical velocity of the rail structure under ideal conditions are deduced.Besides,this st udy considers the implementation of the SFST in the vehicle-structure coupling system.The alterable element method is introduced for accurately simulating the change of the whee-rail contact state and coding a vehicle-structure dynamic analysis program(VSDAP)to calculate the critical velocity of rail structures from the dynamic response of vehicles and rail structures.The principle of its design at the beginning of the design is given on the basis of the theoretical value of the critical velocity and the simulation of the dynamic response,which can provide reference for practical engineering design.
基金The research is financially supported by First-class Undergraduate Course Funding Project in Hunan Province-Virtual Simulation Experimental Teaching Course(Xiang Jiao Tong[2021]No.28),Hunan Engineering Teaching Team)(Xiang Jiao Tong[2019]No.370)National Experimental Teaching Center of Civil Engineering Virtual Simulation(Central South University)Open Project(202001)Education and Teaching Reform Project of Central South University(2020jy063),which is gratefully acknowledged by the authors.
文摘Virtual simulation teaching is an addendum to the experimental teaching mode of railway engineering,and the two teaching methods complement each other and merge with each other.In view of the current research,there is little discussion about the integration path of the two above.Based on the connotation and design of virtual simulation teaching,this research systematically expounds the integration of the real path and path optimization problems,and puts forward the railway engineering experimental teaching principles based on virtual simulation teaching.On the basis of this research,a virtual simulation experiment platform for vibration mechanics and its application in the floating slab vibration damping track was developed to make full use of three-dimensional modeling,virtual reality,human-computer interaction and other technologies,which can realistically simulate the vibration law and vibration damping effect of the rail transit system,and in the hope that the virtual simulation teaching can be widely used in the experimental teaching mode of railway engineering in the future.
基金The authors are very grateful for the financial support received from the National Natural Science Foundation of China(Grant Nos.51668020,51878277,51478184).
文摘Underground railway vibration source strength is one of the key values used for environmental impact assessment and the evaluation of mitigation measure’s performance.However,currently there is no international standard of measuring the underground railway vibration source strength for such purposes.The available local standards and industrial guidelines do not agree on measurement locations as well as the metrics for presenting the source strength.This has caused many confusions.This paper aims to study the suitable measurement location and metrics using the data from a large scale field-testing carried out at the Nanchang underground railway(Metro Line 1,China)in 2017.200 passing trains were recorded during the test at two different sections of the railway line,one with the spring floating slab installed and the other without.Three locations were chosen at each section,including one in the middle of the track and two on the tunnel wall at different heights.Based on the results of statistical analysis,the maximum of z-weighted vertical vibration level(VLzmax)obtained at a lower measurement location on the tunnel wall is the best for representing the underground railway vibration source strength,which is 76.66 dB obtained from this study.