The Main Himalayan Thrust(MHT),where the 2015 MW7.8 Gorkha earthquake occurred,features the most seismicity of any structure in Nepal.The structural complexity of the MHT makes it difficult to obtain a definitive inte...The Main Himalayan Thrust(MHT),where the 2015 MW7.8 Gorkha earthquake occurred,features the most seismicity of any structure in Nepal.The structural complexity of the MHT makes it difficult to obtain a definitive interpretation of deep seismogenic structures.The application of new methods and data in this region is necessary to enhance local seismic hazard analyses.In this study,we used a well-designed machine learning-based earthquake location workflow(LOC-FLOW),which incorporates machine learning phase picking,phase association,absolute location,and double-difference relative location,to process seismic data collected by the Hi-CLIMB and NAMASTE seismic networks.We built a high-precision earthquake catalog of both the quiet-period and aftershock seismicity in this region.The seismicity distribution suggests that the quietperiod seismicity(388 events)was controlled by a mid-crustal ramp and the aftershock seismicity(12,669 events)was controlled by several geological structures of the MHT.The higher-level detail of the catalogs derived from this machine learning method reveal clearer structural characteristics,showing how the flat-ramp geometry and a possible duplex structure affect the depth distribution of the seismic events,and how a tear fault changes this distribution along strike.展开更多
The low level radio frequency(LLRF) system for booster accelerator at Shanghai Synchrotron Radiation Facility(SSRF) was upgraded by a digital controller based on field programmable gate array(FPGA) technology.Paramete...The low level radio frequency(LLRF) system for booster accelerator at Shanghai Synchrotron Radiation Facility(SSRF) was upgraded by a digital controller based on field programmable gate array(FPGA) technology.Parameters of voltage, frequency and field flatness in the two 5-cell cavities are controlled to meet the requirements of booster. In this article, the ramping curve of cavity voltage, amplitude and phase control loop with vector sum of the two 5-cell cavities, tuning loop and field flatness loop are analyzed and discussed in detail.A different method in tuning loop is adopted due to the limitations of ADC channels. The function realizes energy ramping of electron beam from 150 Me V to 3.5 Ge V with a repetition rate of 2 Hz. With the new LLRF controller, the phase stability at ramping mode in 10 hours long operation is improved from ±1.5°(RMS) with open loop to ±0.15°(RMS) with close loop, while the detuning phase and field flatness are maintained to within ±2°and ±1%, respectively.展开更多
Hanging wall syncline and central dome are special extension structures, developing over the hanging wall in an extensional ramp-flat fault. Under the condition that the flat is sub-horizontal, the hanging wall syncli...Hanging wall syncline and central dome are special extension structures, developing over the hanging wall in an extensional ramp-flat fault. Under the condition that the flat is sub-horizontal, the hanging wall syncline is separated from the half graben by the central dome. And on the dome forms an erosional surface. Both sediments in the half graben and erosional surface on the top of the central dome extended over the dome and entered into the hanging wall syncline with extension going on. Meanwhile, those having entered were overlapped by new sedimentary layers in the hanging wall syncline, so that there is a together-threaded, diachronic unconformity to form in the same epoch stratum. The layers in the hanging wall syncline also have an attribute of migrating laterally and getting tilted with extension. There is no sedimentation on the central dome. But sediments, which came from the half graben, got thicker over the dome in extension.展开更多
基金funded by the National Key R&D Program of China(2022YFF0800601)National Natural Science Foundation of China(42174069,U1939204).
文摘The Main Himalayan Thrust(MHT),where the 2015 MW7.8 Gorkha earthquake occurred,features the most seismicity of any structure in Nepal.The structural complexity of the MHT makes it difficult to obtain a definitive interpretation of deep seismogenic structures.The application of new methods and data in this region is necessary to enhance local seismic hazard analyses.In this study,we used a well-designed machine learning-based earthquake location workflow(LOC-FLOW),which incorporates machine learning phase picking,phase association,absolute location,and double-difference relative location,to process seismic data collected by the Hi-CLIMB and NAMASTE seismic networks.We built a high-precision earthquake catalog of both the quiet-period and aftershock seismicity in this region.The seismicity distribution suggests that the quietperiod seismicity(388 events)was controlled by a mid-crustal ramp and the aftershock seismicity(12,669 events)was controlled by several geological structures of the MHT.The higher-level detail of the catalogs derived from this machine learning method reveal clearer structural characteristics,showing how the flat-ramp geometry and a possible duplex structure affect the depth distribution of the seismic events,and how a tear fault changes this distribution along strike.
基金Supported by the National Natural Science Foundation of China(No.11335014)
文摘The low level radio frequency(LLRF) system for booster accelerator at Shanghai Synchrotron Radiation Facility(SSRF) was upgraded by a digital controller based on field programmable gate array(FPGA) technology.Parameters of voltage, frequency and field flatness in the two 5-cell cavities are controlled to meet the requirements of booster. In this article, the ramping curve of cavity voltage, amplitude and phase control loop with vector sum of the two 5-cell cavities, tuning loop and field flatness loop are analyzed and discussed in detail.A different method in tuning loop is adopted due to the limitations of ADC channels. The function realizes energy ramping of electron beam from 150 Me V to 3.5 Ge V with a repetition rate of 2 Hz. With the new LLRF controller, the phase stability at ramping mode in 10 hours long operation is improved from ±1.5°(RMS) with open loop to ±0.15°(RMS) with close loop, while the detuning phase and field flatness are maintained to within ±2°and ±1%, respectively.
文摘Hanging wall syncline and central dome are special extension structures, developing over the hanging wall in an extensional ramp-flat fault. Under the condition that the flat is sub-horizontal, the hanging wall syncline is separated from the half graben by the central dome. And on the dome forms an erosional surface. Both sediments in the half graben and erosional surface on the top of the central dome extended over the dome and entered into the hanging wall syncline with extension going on. Meanwhile, those having entered were overlapped by new sedimentary layers in the hanging wall syncline, so that there is a together-threaded, diachronic unconformity to form in the same epoch stratum. The layers in the hanging wall syncline also have an attribute of migrating laterally and getting tilted with extension. There is no sedimentation on the central dome. But sediments, which came from the half graben, got thicker over the dome in extension.