期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Tuning rheology and fire-fighting performance of protein-stabilized foam by actively switching the interfacial state of the liquid film
1
作者 Ke Qiu Xiaoyang Yu +1 位作者 Huan Li Shouxiang Lu 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2024年第11期120-132,共13页
Biomolecular self-assembly has lately emerged as an intriguing method for creating stable gas-liquid dis-persions with unique functional characteristics.In this work,protein-metal coordination complexes were designed ... Biomolecular self-assembly has lately emerged as an intriguing method for creating stable gas-liquid dis-persions with unique functional characteristics.In this work,protein-metal coordination complexes were designed as the stabilizer for generating ultrastable fire-fighting foam and creating interfacial architec-tures that were actively switched between"rigid"and"mobile"interfacial states of liquid films in re-sponse to changes in pH and bulk solution compositions(metal ions or alkyl polyglycosides).The re-flected light interferometric technique was used to check interfacial states,and the foaming kinetics and rheological response of aqueous solution and liquid foam were investigated by dynamic surface tension tests and oscillatory rheology analysis.The results showed that liquid foams with mobile films with lower yield limits had a faster spreading rate to cover the burning oil,liquid foams with semi-rigid films can-not extinguish fires due to interfacial instability,and the enhanced rheology of the foam with rigid films established a robust and impenetrable barrier to effectively suppress fuel evaporation and combustion.A new correlation between interfacial properties and the fire-fighting performance of foam was proposed,which showed that the fire-extinguishing time of foam could be well correlated by the interfacial states or film lifetime rather than classical thermodynamics entry,spreading,and bridging coefficients(ESB co-efficients). 展开更多
关键词 fire-fighting foams Interfacial states RHEOLOGY Protein SURFACTANT
原文传递
Practical and Risk-Based Management of Potential PFAS Contamination for Your Project
2
作者 Wendy A.Presler Kristen Freiburger Stephen B.Ellingson 《Journal of Civil Engineering and Architecture》 2025年第6期279-287,共9页
PFASs(per-and polyfluoroalkyl substances)are a group of more than 12,000 man-made chemicals used in industrial,commercial,and consumer products since the 1940s.Their unique chemical structure resists degradation and t... PFASs(per-and polyfluoroalkyl substances)are a group of more than 12,000 man-made chemicals used in industrial,commercial,and consumer products since the 1940s.Their unique chemical structure resists degradation and they are often referred to as“forever chemicals”because of how long they persist in the environment.PFASs are also known to accumulate in human tissue.Exposure to certain PFAS at very low concentrations can cause kidney and testicular cancer,hormone disruption,and liver and thyroid diseases.Based on our experience managing PFAS impacted soil and groundwater at geotechnical construction vertical(structures)and horizontal(infrastructure and roads)projects,we present case studies to describe the current federal and state regulatory landscape for this group of emerging contaminants.This paper will provide a summary of basic sampling,testing,and risk-assessment approaches as well as solutions for cost effective treatment and acceptable disposal options. 展开更多
关键词 PFAS AFFF(aqueous fire-fighting foam) groundwater contamination soil contamination
在线阅读 下载PDF
Practice of Fighting Fire and Suppressing Explosion for a Super-Large and Highly Gassy Mine 被引量:20
3
作者 ZHOU Fu-bao WANG De-ming +2 位作者 ZHANG Yong-jiu ZHANG Yu-liang LI Xiang 《Journal of China University of Mining and Technology》 EI 2007年第4期459-463,共5页
The Baijigou Mine fire in Ningxia Province,which broke out on October 24,2003,affected more than 108 m3 of the mine and was probably the largest underground fire in China in recent years. In addition to its size,the f... The Baijigou Mine fire in Ningxia Province,which broke out on October 24,2003,affected more than 108 m3 of the mine and was probably the largest underground fire in China in recent years. In addition to its size,the fire was also characterized by excessive air leakage and the potential for violent methane explosions. A series of new measures were taken to fight the fire,including sealing intake tunnels with water,injecting three-phase foam through boreholes,and flushing with a large volume of nitrogen. The fire was successfully extinguished and production re-sumed soon afterwards; not one single methane explosion occurred during fire-fighting and afterwards. 展开更多
关键词 mine fire gas explosion fire-fighting explosion-suppression three-phase foam
在线阅读 下载PDF
Research on Multi-robot Coordination Searching Ignition Sources Approach
4
作者 Jun Li Wen-Long Song Pu-Cheng Zhou 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2013年第2期50-54,共5页
For the purpose of study on forecasting forest fire behavior,a probability approach was presented to search ignition sources by multi-robot coordination. Firstly,the environment map is built based on Bayes rules. Then... For the purpose of study on forecasting forest fire behavior,a probability approach was presented to search ignition sources by multi-robot coordination. Firstly,the environment map is built based on Bayes rules. Then,the probability searching strategy based on the environment map was designed. Every grid of the searching area was assigned searching expectation value, and robots selected the grid with the highest expectation value as its searching target. The simulation results show the search time reduces greatly,which proves the feasibility and validity of the given algorithm under unknown fire condition. 展开更多
关键词 fire-fighting robots Bayes rules multi-robot coordination
在线阅读 下载PDF
Nozzle Light Powered by Energy Harvesting Technology
5
作者 Jung-Huang Liao Dein Shaw 《Journal of Energy and Power Engineering》 2012年第10期1589-1596,共8页
The invention of this study harvests a portion of hydropower in the fire hose to drive a micro turbine generator and the electric power generated is used to light the LED (light-emitting diode) attached on the fire ... The invention of this study harvests a portion of hydropower in the fire hose to drive a micro turbine generator and the electric power generated is used to light the LED (light-emitting diode) attached on the fire nozzle for the illumination of dark scene (it is called nozzle light in this study). The simulation and experiment are done to match the design of nozzle light. Nozzle light provides firefighters a synergistic function to spray the water and illuminate the fire field at the same time without requiring any extra hand to handle the light. It indeed increases both the efficiency of putting off a fire and the safety of firefighters. The most innovative benefit is that neither heavy battery nor utility wires are needed to get the lighting. 展开更多
关键词 fire-fighting ILLUMINATION energy harvesting LED (light-emitting diode).
在线阅读 下载PDF
Assessing the accessibility to fire hazards in preserving historical towns: Case studies in suburban Shanghai, China
6
作者 Harrison Huang Lu Li Yan Gu 《Frontiers of Architectural Research》 CSCD 2022年第4期731-746,共16页
Protecting large-scale heritage settlements from being damaged by fires has become increasingly crucial in developing areas that lack adequate legislation, emergency planning, and particularly efficient techniques. Th... Protecting large-scale heritage settlements from being damaged by fires has become increasingly crucial in developing areas that lack adequate legislation, emergency planning, and particularly efficient techniques. This study provides a systematic emergency assessment methodology for evaluating the accessibility of specific fire-fighting techniques to mitigate fire hazards in historical towns and examines how the integration of municipal and local fire services works. Specifically, this paper examines the accessibility of fire trucks, local fire services and the overall protection capacity. There are quantitative calculations of the obstruction degrees on main streets, the feasible moving distances of fire-fighting vehicles and firefighters at a given time, and the fire protection coverage and intensity in each town. Using these methods, this paper systematically assesses the fire resistance of three historical towns, Chuansha, Gaoqiao and Fengjing, as case studies. In contrast to previous studies focusing on the vulnerability of buildings in large historical settlements, this assessment method combines an examination of street networks and various emergency response techniques and is particularly applicable to developing areas. 展开更多
关键词 Accessibility to fire hazards Emergency assessments fire-fighting techniques Heritage protection Historical towns Developing areas
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部