期刊文献+
共找到134篇文章
< 1 2 7 >
每页显示 20 50 100
Effects of advancing tunnel on a loaded pile:Numerical analysis and field measurements
1
作者 Cheemin Khoo Hisham Mohamad +3 位作者 Aizat Akmal A.Mohamad Beddelee Phromphat Thansirichaisree Muhammad Farid Ghazali Muhammad Yusoff Mohd Nasir 《Journal of Rock Mechanics and Geotechnical Engineering》 2025年第10期6145-6158,共14页
A full-scale research study was conducted during the bored tunnelling of the Klang Valley Mass Rapid Transit-Putrajaya Line beneath an existing building structure in Kuala Lumpur,Malaysia.The primary objective was to ... A full-scale research study was conducted during the bored tunnelling of the Klang Valley Mass Rapid Transit-Putrajaya Line beneath an existing building structure in Kuala Lumpur,Malaysia.The primary objective was to investigate the tunnel-soil-pile interaction at various stages of tunnel excavation.This study combined field measurements and three-dimensional(3D)numerical analysis to understand the transient effects of TBM tunnelling on a loaded pile.An experimental pile was instrumented with vibrating wire strain gauges,an inclinometer,and distributed fibre optic sensors using Brillouin optical time domain analysis.The pile was pre-loaded and continuously monitored in real-time throughout the tunnel construction process.The 3D finite element modelling was used to simulate the pile’s transient responses based on actual tunnel boring machine(TBM)driving data.The study revealed that the zone of influence due to tunnelling effects extended from y¼2D to y¼4D,with the peak effect observed at y¼1D to 1.5D,where D represents the tunnel diameter.The analysis of axial load patterns highlighted transient responses,including tensile loads below the tunnel invert,which propagated upward and subsided due to negative skin friction.The maximum downdrag load observed reached 56%e71%of the pile’s working load.Additionally,pile movement patterns indicated outward deflections as the TBM approached and a return toward the tunnel post-passage,aligning with the predicted behaviour in a negative face loss scenario.This validated numerical framework provides a solid foundation for further parametric studies and enhances the understanding of tunnel-soil-pile interactions. 展开更多
关键词 field measurement Numerical analysis Tunnel-soil-pile interaction Transient effects Pile responses
在线阅读 下载PDF
Measurement of wind field characteristics at a long-span suspension bridge 被引量:6
2
作者 胡俊 郭健 欧进萍 《Journal of Southeast University(English Edition)》 EI CAS 2011年第3期328-334,共7页
In order to provide a reliable basis for wind resistant evaluation of a long-span suspension bridge, a structural health monitoring system is installed on a bridge in the East China Sea and the simultaneous wind data ... In order to provide a reliable basis for wind resistant evaluation of a long-span suspension bridge, a structural health monitoring system is installed on a bridge in the East China Sea and the simultaneous wind data at the bridge deck and at the top of the bridge tower are recorded. The average wind speeds and directions, variations of wind speeds with height, turbulent characteristics, spatial correlation and characteristics of wind flow around the bridge deck are analyzed by using statistical methods and spectral analysis. It is found that the average wind speeds along the bridge girder are almost identical; however, the mean wind directions vary greatly at different locations. The dimensionless exponent decreases as the average wind speed increases. The measured turbulence intensities are greater than the recommended values, and the turbulence power spectrum can well fit the standard spectrum. However, the measured spectral values are considerably smaller in low frequency ranges. The mean wind speed of the wake flow decreases and the turbulence intensity increases significantly, and the spectral characteristics of the wake flow change obviously while the feature frequency of vortex shedding has not yet been observed. 展开更多
关键词 suspension bridge wind field structural health monitoring system field measurement
在线阅读 下载PDF
Field measurements on thermal comfort of a building with double-skin faade in winter 被引量:1
3
作者 王芳 张小松 +2 位作者 李舒宏 朱文运 胡渠 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期292-296,共5页
Field measurements on thermal comfort were carried out in a building with double-skin faade from January 14th to 16th,2009.Data are obtained by measurements of physical parameters and a questionnaire survey is conduct... Field measurements on thermal comfort were carried out in a building with double-skin faade from January 14th to 16th,2009.Data are obtained by measurements of physical parameters and a questionnaire survey is conducted at the same time in 27 offices of the building.The subjective survey involves questions on demographic information of the occupants,health status,environmental comfort conditions and acceptance.A total of 150 occupants are investigated and 131 questionnaires are completed.The statistical data presents the distributions of predicted mean vote,mean thermal sensation vote,mean thermal comfort vote,thermal acceptability,etc.The results show that low relative humidity is the main reason causing thermal discomfort.The greatest discomfort is dry mouth and eye dryness which are caused by low relative humidity.The females are verified to be more sensitive than the males.Meanwhile,a double-skin faade represents a good noise insulation effect while the glare problem is still unresolved. 展开更多
关键词 thermal comfort field measurement double-skin faade
在线阅读 下载PDF
Field Measurements of Influence of Sand Transport Rate on Structure of Wind-sand Flow over Coastal Transverse Ridge 被引量:10
4
作者 DONG Yuxiang S L NAMIKAS +1 位作者 P A HESP MA Jun 《Chinese Geographical Science》 SCIE CSCD 2008年第3期255-261,共7页
The structure of wind-sand flow under different total sand transport rates was measured with field vertical anemometer and sand trap on the crest of typical coastal transverse ridge in Changli Gold Coast of Hebei Prov... The structure of wind-sand flow under different total sand transport rates was measured with field vertical anemometer and sand trap on the crest of typical coastal transverse ridge in Changli Gold Coast of Hebei Province, which is one of the most typical coastal aeolian distribution regions in China and famous for the tall and typical coastal transverse ridges. The measurement results show that, on the conditions of approximate wind velocities and same surface materials and environments, some changes happen to the structure of wind-sand flow with the increase of total sand transport rate on the crest of coastal transverse ridge. First, the sand transport rates of layers at different heights in the wind-sand flow increase, with the maximum increase at the height layer of 4-8cm. Second, the ratios of sand trans-port rates of layers at different heights to total sand transport rate decrease at the low height layer (0-4cm), but increase at the high height layer (4-60cm). Third, the distribution of the sand transport rate in the wind-sand flow can be expressed by an exponential function at the height layer of 0-40cm, but it changes from power function model to ex-ponential function model in the whole height layer (0-60cm) and changes into polynomial function model at the height layer of 40-60cm with the increase of total sand transport rate. Those changes have a close relationship with the limit of sand grain size of wind flow transporting and composition of sand grain size in the wind-sand flow. 展开更多
关键词 sand transport rate coastal transverse ridge structure of wind-sand flow field measurement
在线阅读 下载PDF
Field measurement and evaluation of vibration in different areas of a metro depot 被引量:7
5
作者 Feng Qingsong Zhang Yunlai +3 位作者 Jiang Jian Wang Ziyu Lei Xiaoyan Zhang Ling 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2022年第2期529-542,共14页
This paper presents a study of the characteristics of a railway vibration at three key sections containing different track structures in a metro depot.The results show that the vertical and horizontal vibration accele... This paper presents a study of the characteristics of a railway vibration at three key sections containing different track structures in a metro depot.The results show that the vertical and horizontal vibration acceleration levels are proportional to train speed.The Z-weighted vertical acceleration levels obtained showed that the vibration source strengths at the ballast foot of the testing line and the throat area were very close.The vibration attenuation at the repair line was larger than that of the testing line.In the throat area,the peak frequency of vibration obtained at the ballast foot(2.5 m)could be shifted to a lower frequency band by using polyurethane sleepers instead of standard concrete sleepers.Polyurethane sleepers can help to reduce vertical vibration in a frequency band of 0-10 Hz.The vibration levels would satisfy the limits given in the ISO2631-2-2003(2013)for any location more than 5 m away from the source at the testing line and 2.5 m away from the source at the repair line and throat area. 展开更多
关键词 field measurement metro depot peak frequency vibration acceleration environmental impacts
在线阅读 下载PDF
Side abutment pressure distribution by field measurement 被引量:8
6
作者 WANG Lian-guo SONG Yang +1 位作者 HE Xing-hua ZHANG Jian 《Journal of China University of Mining and Technology》 EI 2008年第4期527-530,共4页
Given the 7123 working face in the Qidong Coal Mine of the Wanbei Mining Group, nine dynamic roof monitors were installed in the crossheading to measure the amount and velocity of roof convergence in different positio... Given the 7123 working face in the Qidong Coal Mine of the Wanbei Mining Group, nine dynamic roof monitors were installed in the crossheading to measure the amount and velocity of roof convergence in different positions and at different times and three steel bored stress sensors were installed in the return airway to measure rock stress at depth. On the basis of this arrange- ment, the rule of change of the distribution of the side abutment pressure with the advance of the working face and movement of overlying strata was studied. The rule of change and the stability of rock stress at depth were measured. Secondly, the affected area and stability time of the side abutment pressure were also studied. The results show that: 1) During working, the face advanced distance was from 157 m to 99 m, the process was not effected by mining induced pressure. When the distance was 82 m, the posi- tion of peak stress was 5 m away from the coal wall. When the distance was 37 m, the position of peak stress away from the coal wall was about 15 m to 20 m and finally reached a steady state; 2) the time and the range of the peak of side rock pressure obtained from stress sensors were consistent with the results from the dynamic roof monitors; 3) the position of the peak pressure was 25 m away from the coal wall. 展开更多
关键词 field measurement side abutment pressure peak pressure pressure distribution
在线阅读 下载PDF
Long-term field measurement and analysis of the natural wind characteristics at the site of Xi-hou-men Bridge 被引量:3
7
作者 Ming LIU Hai-li LIAO +2 位作者 Ming-shui LI Cun-ming MA Mei YU 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2012年第3期197-207,共11页
In order to investigate the wind characteristics of coastal areas of China, a long-term field measurement of natural wind was carried out. Based on the field measurement results, this paper presents the natural wind c... In order to investigate the wind characteristics of coastal areas of China, a long-term field measurement of natural wind was carried out. Based on the field measurement results, this paper presents the natural wind characteristics of typhoons and strong monsoons at the site of Xi-hou-men Bridge, including mean wind speed, mean wind direction, mean wind elevation angle, turbulent intensity, gust factor, turbulence integral length scales, power spectrum of wind speed and spatial correlation of gusty wind, the profiles of mean wind speed and turbulent intensity, etc. The correlation among wind characteristics is analyzed in detail, and the similarities and differences of wind characteristics between typhoons and monsoons are analyzed. These results can pro- vide detailed wind characteristics of coastal areas of China. 展开更多
关键词 Wind characteristics field measurement Wind spectrum Wind profiles Spatial correlation
原文传递
Characterizing ship-induced hydrodynamics in a heavy shipping traffic waterway via intensified field measurements 被引量:2
8
作者 Li-lei Mao Yi-mei Chen Xin Li 《Water Science and Engineering》 EI CAS CSCD 2020年第4期329-338,共10页
Ship-induced hydrodynamics play an important role in shaping the cross-sectional profile of inland waterways and produce a large amount of pressure on the fluvial environment.This study aimed at quantifying the charac... Ship-induced hydrodynamics play an important role in shaping the cross-sectional profile of inland waterways and produce a large amount of pressure on the fluvial environment.This study aimed at quantifying the characteristics of ship-induced waves and currents in a heavy shipping traffic waterway via intensified field measurements conducted in the Changzhou segment of the Grand Canal,in Jiangsu Province,China.Based on the processed hydrodynamic data,waves and currents caused by single ships and multiple ships were investigated.For single ships,the shipinduced wave heights estimated with empirical formulas were not consistent with the observations.Categorized by the loading conditions of barges,the drawdown height was characterized by the ratio of ship speed to its limit speed.The maximum non-dimensional ship-induced wave height was parameterized by a nonlinear combination of the depth Froude number and a blockage coefficient.For multiple ships,when ships closely followed each other or interlaced each other's paths,it was difficult to characterize the superposition of several ship wakes.The magnitudes of current velocities induced by single ships and multiple ships were respectively nine and six times as large as those of natural flow.This may result in more severe sediment(re)suspension than natural flows.©2020 Hohai University.Production and hosting by Elsevier B.V.This is an open access article under the CC BY-NC-ND license(http://creativecommons.org/licenses/by-nc-nd/4.0/). 展开更多
关键词 Ship-induced waves DRAWDOWN field measurements Current velocity Sediment(re)suspension Grand Canal
在线阅读 下载PDF
Electric field intensity measurement by using doublet electromagnetically induced transparency of cold Rb Rydberg atoms 被引量:1
9
作者 宫廷 师帅 +7 位作者 姬中华 郭古青 孙小聪 田亚莉 邱选兵 李传亮 赵延霆 贾锁堂 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第10期405-409,共5页
We demonstrate a simple method to measure electric field intensity by using doublet electromagnetically induced transparency(EIT) spectra of cold Rb Rydberg atoms, where the frequency of the coupling laser does not ne... We demonstrate a simple method to measure electric field intensity by using doublet electromagnetically induced transparency(EIT) spectra of cold Rb Rydberg atoms, where the frequency of the coupling laser does not need to be locked. Based on the Stark splitting of the Rb Rydberg state, 10D_(3/2), under electric fields and the corresponding calculated polarizabilities, the real electric field intensity is calculated using the difference in radio-frequency diffraction between two acousto-optic modulators, which acts as a frequency criterion that allows us to measure the electrical field without locking the coupling laser. The value measured by this simple method shows a good agreement with our previous work [Opt.Express 29 1558(2021)] where the frequency of the coupling laser needs to be locked with an additional EIT spectrum based on atom vapor and a proportional–integral–differential feedback circuit. Our presented method can also be extended to the measurement of electric field based on hot Rydberg atom vapor, which has application in industry. 展开更多
关键词 doublet electromagnetically induced transparency(EIT) Aulter–Townes(AT)splitting Rydberg atom electric field measurement
原文传递
EXPERIMENTAL MEASUREMENT OF MAGNETIC FIELD IN A NOVEL FLOW CONTROL OF MOLD 被引量:1
10
作者 G.J. Xu, D.H. Li and J.C. HeThe Key Laboratory of National Education Ministry for Electromagnetic Processing of Materials, Northeastern University, Shenyang 110006, China Manuscript received 10 September 2001 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2002年第3期260-266,共7页
In order to know the distribution of magnetic field in a novel flow control of mold (NFC Mold) and to provide the experimental data for the electromagnetic structure design and the analysis of flow control in continuo... In order to know the distribution of magnetic field in a novel flow control of mold (NFC Mold) and to provide the experimental data for the electromagnetic structure design and the analysis of flow control in continuous casting mold, the magnetic field in a NFC Mold were measured by Tesla meter of Model CT-3. The method of vector synthesis was adopted in the measurement of magnetic fields. The results showed that the magnetic field in the NFC Mold was composed of two main magnetic areas that were symmetrical. Although there was leaking magnetic flux between the lower surface of the upper pole and the upper surface of the lower pole on the sides, it was restrained by the main magnetic fields effectively. Therefore the NFC Mold was more preferably satisfied to be used in controlling the molten steel flow in continuous casting mold. 展开更多
关键词 continuous casting mold measurement of magnetic field method of vector synthesis
在线阅读 下载PDF
EXPERIMENTAL INVESTIGATION FOR THE EFFECT OF ROTATION ON THREE-DIMENSIONAL FLOW FIELD IN FILM-COOLED TURBINE 被引量:2
11
作者 YUAN Feng ZHU Xiaocheng DU Zhaohui 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2007年第1期10-15,共6页
An experimental investigation of three-dimensional flow field in a film-cooled turbine model is carried out by using particle image velocimeter (PIV) in a low-speed wind tunnel. The effects of different blowing rati... An experimental investigation of three-dimensional flow field in a film-cooled turbine model is carried out by using particle image velocimeter (PIV) in a low-speed wind tunnel. The effects of different blowing ratios (M=1.5, 2) on the flow field are studied. The experimental results reveal the classical phenomena of the formation of kidney vortex pair and secondary flow in wake region behind the jet hole. And the changes of the kidney vortex pair and the wake at different locations away from the hole on the suction and pressure sides are also studied. Compared with the flow field in stationary cascade, there are centrifugal force and Coriolis force existing in the flow field of rotating turbine, and these forces bring the radial velocity in the jet flow. The effect of rotatien on the flow field of the pressure side is more distinct than that on the suction side from the measured flow fields in Y-Z plane and radial velocity contours. The increase of blowing ratio makes the kidney vortex pair and the secondary flow in the wake region stronger and makes the range of the wake region enlarged. 展开更多
关键词 Film-cooled turbine rotor PIV measurement Blowing ratio Three-dimensional flow field
在线阅读 下载PDF
Estimation of the Lyman-α signal of the EFILE diagnostic under static or radiofrequency electric field in vacuum
12
作者 Carlo POGGI Theo GUILLAUME +1 位作者 Fabrice DOVEIL Laurence CHIERIGIER-KOVACIC 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第7期1-6,共6页
The electric field induced Lyman-a emission diagnostic aims to provide a non intrusive and precise measurement of the electric field in plasma, using a beam of hydrogen atoms prepared in the metastable 2s state. The m... The electric field induced Lyman-a emission diagnostic aims to provide a non intrusive and precise measurement of the electric field in plasma, using a beam of hydrogen atoms prepared in the metastable 2s state. The metastable particles are obtained by means of a proton beam extracted from a hydrogen plasma source, and neutralised by interaction with vaporised caesium. When a 2s atom enters a region where an electric field is present, it undergoes a transition to the 2p state (Stark mixing). It then quickly decays to the ground level, emitting Lyman-a radiation, which is collected by a photomultiplier. The 2s → 2p transition rate is proportional to the square of the magnitude of the electric field, and depends on the field oscillation frequency (with peaks around l GHz). By measuring the intensity of the Lyman-a radiation emitted by the beam it is possible to determine the magnitude of the field in a defined region. In this work, an analysis of the behaviour of the diagnostic under static or radiofrequency electric field is presented. Electric field simulations obtained with a finite element solver of Maxwell equations, combined with theoretical calculations of the Stark mixing transition rate, are used to develop a model for the interpretation of photomultiplier data. This method shows good agreement with experimental results for the static field case, and allows to measure the field magnitude for the oscillating case. 展开更多
关键词 electric field measurement electromagnetic simulations Stark effect plasma diagnostics
在线阅读 下载PDF
Data-model coupling driven stress field measurements
13
作者 Guangbo Wang Jian Zhao +1 位作者 Jiahui Liu Dong Zhao 《Theoretical & Applied Mechanics Letters》 CAS CSCD 2024年第4期280-290,共11页
This paper presents a method for measuring stress fields within the framework of coupled data models,aimed at determining stress fields in isotropic material structures exhibiting localized deterioration behavior with... This paper presents a method for measuring stress fields within the framework of coupled data models,aimed at determining stress fields in isotropic material structures exhibiting localized deterioration behavior without relying on constitutive equations in the deteriorated region.This approach contributes to advancing the field of intrinsic equation-free mechanics.The methodology combines measured strain fields with data-model coupling driven algorithms.The gradient and Canny operators are utilized to process the strain field data,enabling the determination of the deterioration region's location.Meanwhile,an adaptive model building method is proposed for constructing coupling driven models.To address the issue of unknown datasets during computation,a dataset updating strategy based on a differential evolutionary algorithm is introduced.The resulting optimal dataset is then used to generate stress field results.Validation against finite element method calculations demonstrates the accuracy of the proposed method in obtaining full-field stresses in specimens with local degradation behavior. 展开更多
关键词 Stress field measurements Data-model coupling driven Differential evolutionary algorithm Material dataset
在线阅读 下载PDF
Field measurements of absolute gravity in East Antarctica
14
作者 Koichiro Doi Hideaki Hayakawa +6 位作者 Takahito Kazama Toshihiro Higashi Shingo Osono Yoichi Fukuda Jun Nishijima Yuichi Aoyama Junichi Ueda 《Advances in Polar Science》 2013年第4期339-343,共5页
This paper reports the results of field-based absolute gravity measurements aimed at detecting gravity change and crustal displacement caused by glacial isostatic adjustment. The project was initiated within the frame... This paper reports the results of field-based absolute gravity measurements aimed at detecting gravity change and crustal displacement caused by glacial isostatic adjustment. The project was initiated within the framework of the 53rd Japanese Antarctic Research Expedition (JARE53). Absolute gravity measurements, together with GPS measurements, were planned at several outcrops along the Prince Olav Coast and S6ya Coast of East Antarctica, including at Syowa Station. Since the icebreaker Shirase (AGB 5003) was unable to moor alongside Syowa Station, operations were somewhat restricted during JARE53. However, despite this setback, we were able to complete measurements at two sites: Syowa Station and Langhovde. The absolute gravity value at the Syowa Station IAGBN (A) site, observed using an FG-5 absolute gravimeter (serial number 210; FG-5 #210), was 982 524 322.7+0.1 ktGal, and the gravity change rate at the beginning of 2012 was -0.26 gGal.a-1. An absolute gravity value of 982 535 584.2~0.7 ktGal was obtained using a portable A-10 absolute gravimeter (serial number 017; A-10 #017) at the newly located site AGS01 in Langhovde. 展开更多
关键词 absolute gravity field measurement ANTARCTICA A-10 and FG-5 absolute gravimeters GPS JARE
在线阅读 下载PDF
Field Measurements and Pullout Tests of Reinforced Earth Retaining Wall
15
作者 陈群 何昌荣 朱分清 《Journal of Southwest Jiaotong University(English Edition)》 2004年第2期165-172,共8页
In this paper, field measurements and pullout tests of a new type of reinforced earth retaining wall, which is reinforced by trapezoid concrete blocks connected by steel bar, are described. Field measurements included... In this paper, field measurements and pullout tests of a new type of reinforced earth retaining wall, which is reinforced by trapezoid concrete blocks connected by steel bar, are described. Field measurements included settlements of the earth fill, tensile forces in the ties and earth pressures on the facing panels during the construction and at completion. Based on the measurements, the following statements can be made: (1) the tensile forces in the ties increased with the height of backfill above the tie and there is a tensile force crest in most ties; (2) at completion, the measured earth pressures along the wall face were between the values of the active earth pressures and the pressures at rest; (3) larger settlements occurred near the face of the wall where a zone of drainage sand and gravel was not compacted properly and smaller settlements occurred in the well-compacted backfill. The results of field pullout tests indicated that the magnitudes of pullout resistances as well as tensile forces induced in the ties were strongly influenced by the relative displacements between the ties and the backfill, and pullout resistances increased with the height of backfill above the ties and the length of ties. 展开更多
关键词 Reinforced earth retaining wall field measurement Pullout test
在线阅读 下载PDF
Energy-Efficient Approaches for a Machine Tool Building in a University through Field Measurement and Energy Modelling
16
作者 Kusnandar Win-Jet Luo +2 位作者 Indra Permana Fu-Jen Wang Gantulga Bayarkhuu 《Energy Engineering》 EI 2023年第6期1387-1399,共13页
The heating,ventilating,and air conditioning(HVAC)system consumes nearly 50%of the building’s energy,especially in Taiwan with a hot and humid climate.Due to the challenges in obtaining energy sources and the negativ... The heating,ventilating,and air conditioning(HVAC)system consumes nearly 50%of the building’s energy,especially in Taiwan with a hot and humid climate.Due to the challenges in obtaining energy sources and the negative impacts of excessive energy use on the environment,it is essential to employ an energy-efficient HVAC system.This study conducted the machine tools building in a university.The field measurement was carried out,and the data were used to conduct energymodelling with EnergyPlus(EP)in order to discover some improvements in energy-efficient design.The validation between fieldmeasurement and energymodelling was performed,and the error rate was less than 10%.The following strategies were proposed in this study based on several energy-efficient approaches,including room temperature settings,chilled water supply temperature settings,chiller coefficient of performance(COP),shading,and building location.Energy-efficient approaches have been evaluated and could reduce energy consumption annually.The results reveal that the proposed energy-efficient approaches of room temperature settings(3.8%),chilled water supply temperature settings(2.1%),chiller COP(5.9%),using shading(9.1%),and building location(3.0%),respectively,could reduce energy consumption.The analysis discovered that using a well-performing HVAC system and building shading were effective in lowering the amount of energy used,and the energy modelling method could be an effective and satisfactory tool in determining potential energy savings. 展开更多
关键词 ENERGY-EFFICIENT energy modelling field measurement BEMS machine tools building
在线阅读 下载PDF
Magnetic Field Measurement with Heisenberg Limit Based on Solid Spin NOON State
17
作者 周雷鸣 董杨 孙方稳 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第6期164-168,共5页
The maximum entangled number state (NOON state) can improve the sensitivity of physical quantity measure- ment to the Heisenberg limit 1/N. In this work, the magnetic field measurement based on the individual solid ... The maximum entangled number state (NOON state) can improve the sensitivity of physical quantity measure- ment to the Heisenberg limit 1/N. In this work, the magnetic field measurement based on the individual solid spin NOON state is investigated. Based on the tunable effective coupling coefficient, we propose a generation scheme of the three-spin NOON state, i.e, the Creenberger-Horne-Zeilinger (CHZ) state, and discussed the mea- surement resolution reduction due to decoherence. It is unnecessary to entangle spins as many as possible when decoherence exists. In practice, defect spins in diamond and alp donors with long coherence time can be applied with current techniques in the nano-scaled high resolution magnetic measurement. 展开更多
关键词 Magnetic field Measurement with Heisenberg Limit Based on Solid Spin NOON State
原文传递
Measurement of high-dynamic temperature field using high-speed quadriwave lateral shearing interferometer
18
作者 崔博川 王建立 +1 位作者 姚凯男 陈涛 《Optoelectronics Letters》 EI 2018年第2期124-128,共5页
An approach to measure a high-dynamic two-dimensional(2 D) temperature field using a high-speed quadriwave lateral shearing interferometer(QWLSI) is proposed. The detailed theoretical derivation to express the wavefro... An approach to measure a high-dynamic two-dimensional(2 D) temperature field using a high-speed quadriwave lateral shearing interferometer(QWLSI) is proposed. The detailed theoretical derivation to express the wavefront reconstruct principle of the proposed method is presented. The comparison experiment with thermocouples shows that the temperature field measurement using QWLSI has a precision of ±0.5 °C. An experiment for measuring the highdynamic temperature field generated by an electrical heater is carried out. A 200 frame rate temperature field video with 512 × 512 resolution is obtained finally. Experimental results show that the temperature field measurement system using a QWLSI has the advantage of high sensitivity and high resolution. 展开更多
关键词 Measurement of high-dynamic temperature field using high-speed quadriwave lateral shearing interferometer
原文传递
Phase unwrapping based on deep learning in light field fringe projection 3D measurement
19
作者 ZHU Xinjun ZHAO Haichuan +3 位作者 YUAN Mengkai ZHANG Zhizhi WANG Hongyi SONG Limei 《Optoelectronics Letters》 EI 2023年第9期556-562,共7页
Phase unwrapping is one of the key roles in fringe projection three-dimensional(3D)measurement technology.We propose a new method to achieve phase unwrapping in camera array light filed fringe projection 3D measuremen... Phase unwrapping is one of the key roles in fringe projection three-dimensional(3D)measurement technology.We propose a new method to achieve phase unwrapping in camera array light filed fringe projection 3D measurement based on deep learning.A multi-stream convolutional neural network(CNN)is proposed to learn the mapping relationship between camera array light filed wrapped phases and fringe orders of the expected central view,and is used to predict the fringe order to achieve the phase unwrapping.Experiments are performed on the light field fringe projection data generated by the simulated camera array fringe projection measurement system in Blender and by the experimental 3×3 camera array light field fringe projection system.The performance of the proposed network with light field wrapped phases using multiple directions as network input data is studied,and the advantages of phase unwrapping based on deep learning in light filed fringe projection are demonstrated. 展开更多
关键词 Phase unwrapping based on deep learning in light field fringe projection 3D measurement
原文传递
The Magnetic Anisotropy and Complete Phase Diagram of CuFeO2 Measured in a Pulsed High Magnetic Field up to 75 T
20
作者 左华坤 时丽然 +6 位作者 夏正才 黄俊伟 陈柏蓉 金昭 魏蒙 欧阳钟文 成刚 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第4期130-133,共4页
The magnetization behavior of a CuFeO2 single crystal grown by the floating zone technique is investigated with a pulsed high magnetic field. We observe a series of field-induced multi-step-like transitions with hyste... The magnetization behavior of a CuFeO2 single crystal grown by the floating zone technique is investigated with a pulsed high magnetic field. We observe a series of field-induced multi-step-like transitions with hysteresis, of which the critical magnetic fields are temperature-dependent and show anisotropy. By using a pulsed high magnetic field up to 75 T, the magnetization behavior shows that the critical transition magnetic fields of spin- flip/flop shift to lower field regions with an increase in temperature. According to the magnetization curves, a complete magnetic phase diagram is depicted. 展开更多
关键词 The Magnetic Anisotropy and Complete Phase Diagram of CuFeO2 Measured in a Pulsed High Magnetic field up to 75 T AFM
原文传递
上一页 1 2 7 下一页 到第
使用帮助 返回顶部