期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Diagnostic value of artificial intelligence computer-assisted diagnosis (computer assisted-diagnosis eye function) for colorectal polyps
1
作者 Hendra Asputra Hasan Maulahela +4 位作者 Achmad Fauzi Cleopas M Rumende Amanda Pitarini Nina Kemala Sari Hamzah Shatri 《Artificial Intelligence in Gastroenterology》 2025年第3期1-9,共9页
BACKGROUND The gold standard for colorectal polyp screening is currently colonoscopy,but the miss rate is still high and the adenoma detection rate and polyp detection rate are still low.The risk factors include the p... BACKGROUND The gold standard for colorectal polyp screening is currently colonoscopy,but the miss rate is still high and the adenoma detection rate and polyp detection rate are still low.The risk factors include the patient,operators,and the tools used.The use of artificial intelligence(AI)in colonoscopy has gained popularity by assisting endoscopists in the detection and characterization of polyps.AIM To evaluate the diagnostic performance of AI-assisted colonoscopy[computer assisted diagnosis(CAD)eye function]for colorectal polyp characterization.METHODS This study used a cross-sectional design conducted at the Gastrointestinal Endoscopy Center of Dr.Cipto Mangunkusumo Hospital in January-May 2024 on adult patients with suspected colorectal polyps.RESULTS A total of 60 patients with 100 polyps were involved in this study.Based on the results of the examination,it was found that the AI CAD eye function examination had a sensitivity of 79.17%,specificity of 75.00%,positive predictive value(PPV)of 89.06%,negative predictive value(NPV)of 58.33%,and accuracy of 78.00%.In polyps with diminutive size,sensitivity was 86.27%,specificity was 60.00%,PPV was 95.65%,NPV was 30.00%,and accuracy was 83.93%.Meanwhile,in polyps with non-diminutive size,sensitivity was 61.90%,specificity was 78.26%,PPV was 72.22%,NPV was 69.23%,and accuracy was 70.45%.In polyps on the left side of the colon,sensitivity was 78.85%,specificity was 81.25%,PPV was 93.18%,NPV was 54.17%,and accuracy was 79.41%.Meanwhile,in rightsided polyps the sensitivity was 80.00%,specificity was 66.67%,PPV was 80.00%,NPV was 66.67%,and accuracy was 75.00%.In sessile polyps the sensitivity was 81.54%,specificity was 50.00%,PPV was 91.38%,NPV was 29.41%,and accuracy was 77.33%.Meanwhile,in non-sessile polyps,the sensitivity was 57.14%,specificity was 88.89%,PPV was 66.67%,NPV was 84.21%,and accuracy was 80.00%.CONCLUSION AI CAD eye function examination had a high sensitivity value in diminutive,sessile polyps and right-sided polyps and a high specificity in non-diminutive,non-sessile polyps and left-sided polyps. 展开更多
关键词 Artificial intelligence Computer-assisted diagnosis eye function Colorectal polyps Inflammatory bowel disease Artificial intelligence assisted
在线阅读 下载PDF
Developmental dependence for functional eye regrowth in Xenopus laevis
2
作者 Cindy X.Kha Kelly Ai-Sun Tseng 《Neural Regeneration Research》 SCIE CAS CSCD 2018年第10期1735-1737,共3页
Introduction:A key challenge in designing tissue repair strategies is knowing whether and how developmental mechanisms are used for successful repair of mature/adult tissues.Although it is known that developmental co... Introduction:A key challenge in designing tissue repair strategies is knowing whether and how developmental mechanisms are used for successful repair of mature/adult tissues.Although it is known that developmental components are used in repair,it remains mostly unclear which ones are required and whether they act similarly as during development.This issue is further complicated by the fact that it is difficult. 展开更多
关键词 Developmental dependence for functional eye regrowth in Xenopus laevis FIGURE RI
暂未订购
Visual function and vision-related quality of life after vitrectomy for idiopathic macular hole: a 12mo followup study 被引量:6
3
作者 Hong-Tao Duan Song Chen +2 位作者 Yue-Xin Wang Jia-Hui Kong Meng Dong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第4期764-769,共6页
· AIM: To investigate the visual function and the relationship with vision-related quality of life(VRQOL)after macular hole repair surgery.· METHODS: Prospective case series. Thirty-six consecutive eyes in 3... · AIM: To investigate the visual function and the relationship with vision-related quality of life(VRQOL)after macular hole repair surgery.· METHODS: Prospective case series. Thirty-six consecutive eyes in 36 patients who underwent pars plana vitrectomy(PPV) and internal limiting membrane(ILM) peeling were included. The 25-item National Eye Institute Visual Function Questionnaire(VFQ-25) was answered by the participants before and 3 and 12 mo after operation. Follow-up visits examinations included best-corrected visual acuity(BCVA), clinical examination,and central macular thickness(CMT) measured by optical coherence tomography(OCT).·RESULTS: Macular-hole closure was achieved in 35 of36 eyes(97.2%). At baseline and months 3 and 12, the log MAR BCVAs(mean±SD) were 1.15±0.47, 0.68±0.53(P 【0.0001 versus baseline), and 0.55 ±0.49(P 【0.001 versus baseline, P =0.273 versus month 3), respectively; the CMTs(μm) were 330 ±81, 244 ±62(P 【0.001 versus baseline), and 225±58(P 【0.001 versus baseline, P =0.222 versus month 3), respectively; the median preoperative VFQ-25 composite score of 73.50(63.92-81.13) increased postoperatively to 85.50(80.04-89.63) at 3mo(P 【0.001)and 86.73(82.50-89.63) at 12mo(P 【0.001) respectively.The improved BCVA was correlated with improvements in five subscales(r =-0.605 to-0.336, P 【0.001 to P =0.046) at 12 mo.· CONCLUSION: PPV with ILM peeling improved anatomic outcome, visual function, and VRQOL. Theimproved BCVA was an important factor related to the improved VRQOL. 展开更多
关键词 idiopathic macular hole VITRECTOMY quality of life National eye Institute Visual function Questionnaire
原文传递
AB088.Quality of life and visual function in patients with Boston type I keratoprosthesis
4
作者 Cristina Bostan Marwan Elfekhfakh Mona Harissi-Dagher 《Annals of Eye Science》 2018年第1期494-494,共1页
Background:To determine patient-reported vision-related quality of life(VR-QoL)following Boston type I keratoprosthesis(BI-KPro)surgery and its association with postoperative best-corrected visual acuity(BCVA).Methods... Background:To determine patient-reported vision-related quality of life(VR-QoL)following Boston type I keratoprosthesis(BI-KPro)surgery and its association with postoperative best-corrected visual acuity(BCVA).Methods:Descriptive cross-sectional study.Consecutive consenting patients with BI-KPro were included.The French National Eye Institute Visual Function Questionnaire-25 administered at 51±18 months postoperatively measured VR-QoL.Clinical charts were reviewed for demographics,indications for BI-KPro,baseline and postoperative(at time of interview)BCVA.For patients operated unilaterally,stratification of VR-QoL scores based on BCVA in the non-operated eye was performed.Multivariate linear regression was carried out,using VR-QoL scores as dependent variables,and demographics and postoperative BCVA as covariates.For patients operated bilaterally,Spearman correlation between VR-QoL scores and BCVA was performed.P<0.05 indicated statistical significance.Results:Sixty-four patients,aged 59±14 years,52%male,with a follow-up of 54±19 months,were included.Postoperative BCVA increased from baseline in all operated eyes(P=0.000).In patients with unilateral BI-KPro(n=52),the VR-QoL overall score was 70.7±25.1.Scores on all questionnaire subscales were greater when BCVA in the non-operated eye was>20/200 compared to 20/200(P=0.000).BCVA in the non-operated eye was positively associated with all subscales(P<0.01)independently of age,sex,follow-up duration and postoperative BCVA in the operated eye.In patients with bilateral BI-KPro(n=12)the VR-QoL overall score was 63.0±18.7.BCVA in the best eye positively correlated with Near/Distance activities,and social functioning subscales(P<0.05).There was no significant difference between VR-QoL scores of patients operated unilaterally vs.bilaterally.Conclusions:We describe VR-QoL more than 4 years after BI-KPro surgery.Compared to data at 1 year previously reported,our results suggest that,as vision progressively deteriorates in the operated eye,patients increasingly rely on their non-operated eye.VR-QoL after bilateral BI-KPro is assessed for the first time,and appears comparable to that after unilateral surgery.Larger,prospective,long-term studies,with assessment at baseline,are warranted. 展开更多
关键词 Boston type I keratoprosthesis(BI-KPro) National eye Institute Visual function Questionnaire-25 vision-related quality of life(VR-QoL)
暂未订购
CHARACTERISTICS OF MULTIFOCAL ELECTRORETINOGRAM IN THE FELLOW EYES OF PATIENTS WITH HIGH MYOPIA WITH RETINAL DETACHMENT
5
作者 宋毅 宫媛媛 +1 位作者 解正高 吴星伟 《Journal of Shanghai Second Medical University(Foreign Language Edition)》 2008年第2期109-114,共6页
Objective To observe the changes on multifocal electroretinography (MfERG) in the fellow eyes of patients with high myopia without fundus lesions and rhegmatogenous retinal detachment (RRD). Methods MfERG was perf... Objective To observe the changes on multifocal electroretinography (MfERG) in the fellow eyes of patients with high myopia without fundus lesions and rhegmatogenous retinal detachment (RRD). Methods MfERG was performed in 66 patients ( 66 eyes) which were grouped into : emmetropes ( n = 22 ) as the control eye ; high myopes without fundus lesions ( corrected visual acuity ≥ 1. 0, n = 15 ) ; and fellow eyes of high myopics with RRD (n = 29 ). The first-order kernels N1, P1, N2 response density and latency were analyzed. Results When compared with the emmetropes group, the high myopes group had significantly reduced N1 , PI , and N2 wave response densities in rings 1 to 6 ( P 〈 0. 05 ), delayed N1 wave latency in rings 3 to 6, and P1 wave latency in rings 3 to 5 ( P 〈 0. 05 ). The fellow eyes group had significantly reduced N1, P1, and N2 wave response densities in rings 1 to 6 and significantly delayed N1 and P1 wave latencies in rings 3 to 6 ( P 〈0. 05) compared with the emmetropes group. Compared with the high myopes group, P1 wave response densities in rings 1 to 6, N1 wave response densities in rings 1,3, 4, and 6, and N2 wave response density in ring 1 were significantly decreased in the fellow eyes group ( P 〈 0. 05 ) ; whereas there were no significant differences in latencies between the two groups (P 〉0.05). Conclusion MfERG can sensitively assess the early changes in visual function in fellow eyes in patients with RRD. 展开更多
关键词 fellow eye high myopia multifocal electroretinogram rhegmatogenous retinal detachment visual function
暂未订购
Single-site Baseline and Short-term Outcomes of Clinical Characteristics and Life Quality Evaluation of Chinese Wet Age-related Macular Degeneration Patients in Routine Clinical Practice 被引量:2
6
作者 Li-Li Wang Wen-Jia Liu Hai-Yun Liu Xun Xu 《Chinese Medical Journal》 SCIE CAS CSCD 2015年第9期1154-1159,共6页
Background:Age-related macular degeneration (AMD) is the leading cause of irreversible vision loss among the older population.In China,treatment of age-related ocular diseases is becoming a priority in eye care ser... Background:Age-related macular degeneration (AMD) is the leading cause of irreversible vision loss among the older population.In China,treatment of age-related ocular diseases is becoming a priority in eye care services.This study was to investigate the clinical characteristics and quality of life of Chinese patients with wet AMD and current treatment types,to evaluate short-term gains in different treatments,and to investigate associations between visual function and vision-related quality of life (VRQoL).Methods:A prospective,observational,noninterventional study was conducted.Basic data were collected from patients with clinical diagnoses of wet AMD before clinical assessments at baseline.VRQoL was measured with the Chinese version of the National Eye Institute Visual Function Questionnaire-25 (NEI VFQ-25).Correlations of the NEI VFQ-25 subscale scores with best-corrected visual acuity (BCVA) and between-group differences were analyzed.Results:A total of 80 wet AMD patients were enrolled,with the mean age of 68.40 years.About one-quarter ofwetAMD patients received intravitreal (IVT) ranibizumab treatment,and 67% of them were treated on apro re nata basis.The visual acuity of patients treated with IVT ranibizumab at month 3 after treatment was significantly increased,whereas patients treated with traditional Chinese medicine achieved no significant improvement.Cronbach's α for the NEI VFQ-25 subscales ranged from 0.697 to 0.843.Eight subscale and overall composite scores were moderately correlated with the BCVA of the better-seeing eye.Significant differences in the overall NEI VFQ-25 scores and other subscales were observed between patients with BCVA in the better-seeing eye of less than 50 letters and the others.Conclusions:Patients treated with IVT ranibizumab experienced better vision improvement at short-term follow-up.The Chinese version of the NEI VFQ-25 is a valid and reliable tool for assessing the VRQoL of Chinese wet AMD patients. 展开更多
关键词 Chinese Version of National eye Institute Visual function Questionnaire-25 RANIBIZUMAB Vision-related Quality of Life Wet Age-related Macular Degeneration
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部