期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Prediction of dispersed phase holdup in pulsed disc and doughnut solvent extraction columns under different mass transfer conditions 被引量:3
1
作者 Yong Wang Kathryn H.Smith +3 位作者 Kathryn Mumford Teobaldo F.Grabin Zheng Li Geoffrey W.Stevens 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2016年第2期226-231,共6页
Using experimental data from a number of pulsed disc and doughnut solvent extraction columns, a unified correla- tion for the prediction of dispersed phase holdup that considers the effects of mass transfer is present... Using experimental data from a number of pulsed disc and doughnut solvent extraction columns, a unified correla- tion for the prediction of dispersed phase holdup that considers the effects of mass transfer is presented. Pulsed disc and doughnut solvent extraction columns (PDDC) have been used for a range of important applications such as ura- nium extraction and nuclear fuel recycling. Although the dispersed phase holdup in a PDDC has been presented by some researchers, there is still the need to develop a robust correlation that can predict the experimental dispersed phase holdup over a range of operating conditions including the effects of mass transfer direction. In this study, dis- persed phase holdup data from different literature sources for a PDDC were used to refit constants for the correlation presented by Kumar and Hartland lind. Eng. Chem. Res.,27 (1988),131-138] which did not consider the effect of col- umn geometry. In order to incorporate the characteristic length of the PDDC (i.e. the plate spacing), the unified cor- relation for holdup proposed by Kumar and Hartland based on data from eight different types of columns [Ind. Eng. Chem. Res.,34 (1995) 3925-3940] was refitted to the PDDC data. New constants have been presented for each hold- up correlation for a PDDC based on regression analysis using published holdup data from PDDCs that cover a range of onerating conditions and nhwical nronerties and consider the direction of mass transfer. 展开更多
关键词 Solvent extraction Liquid extraction Pulsed disc and doughnut columns Solvent extraction column design Holdup Dispersed phase holdup Hydrodynamics of extraction columns
在线阅读 下载PDF
Comparison of the Reynolds-averaged Turbulence Models on Single Phase Flow Simulation in Agitated Extraction Columns 被引量:4
2
作者 尤学一 H.J.Bart 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2003年第3期362-366,共5页
The flow field of liquid phase (water) of agitated extraction columns is simulated with the help of computational fluid dynamics (CFD). Four kinds of Reynolds-averaged turbulence models, i.e. the standard k-ε model, ... The flow field of liquid phase (water) of agitated extraction columns is simulated with the help of computational fluid dynamics (CFD). Four kinds of Reynolds-averaged turbulence models, i.e. the standard k-ε model, the RNG (renormalization group) k-s model, the realizable k-ε model and the Reynolds stress model, are compared in detail in order to judge which is the best model in terms of the accuracy, less CPU time and memory required. The performance of the realizable k-s model is obviously improved by reducing the model constant from C2 = 1.90 to C2 = 1.61. It is concluded that the improved realizable k-e model is the optimal model. 展开更多
关键词 agitated extraction column turbulence models computational fluid dynamics
在线阅读 下载PDF
The Resident Time Distribution of Injected Dispersed Drops in Stirred Extraction Columns 被引量:2
3
作者 尤学一 李丹 李胜华 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2005年第6期726-731,共6页
A resident time model is proposed to evaluate the performance of agitated extraction columns. In this model, the resident time of dispersed drops is simulated with the discrete phase modeling, where the continuous pha... A resident time model is proposed to evaluate the performance of agitated extraction columns. In this model, the resident time of dispersed drops is simulated with the discrete phase modeling, where the continuous phase and the dispersed phase (drops) are described by the single-phase Navier-Stokes (turbulence) model and Lagrangian model, respectively. The interaction of dispersed phase and continuous phase is neglected for the low concentration of drop in the cases studied. The statistical parameters of drops (the average resident time and standard deviation) under different operation conditions are computed for four columns. The relation of the above statistical parameters with the performance of columns is discussed and the criterions for an optimal compartment are outlined. Our results indicate that the resident time model is useful to evaluate the performance and optimize the design of extraction columns. 展开更多
关键词 resident time stirred extraction column discrete phase modeling computational fluid dynamics
在线阅读 下载PDF
Mass Transfer and Axial Mixing Characteristics in a Coalescence-Dispersion Pulsed-Sieve-Plate Extraction Column 被引量:2
4
作者 唐晓津 骆广生 汪家鼎 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2004年第6期857-861,共5页
A new configuration of coalescence-dispersed pulsed-sieve-plate extraction column (CDPSEC) was developed, and the mass transfer and axial mixing characteristics were evaluated with the two-point dynamic method.The inf... A new configuration of coalescence-dispersed pulsed-sieve-plate extraction column (CDPSEC) was developed, and the mass transfer and axial mixing characteristics were evaluated with the two-point dynamic method.The influence of operation conditions was discussed with experimental results, showing that the mass transfer performance of CDPSEC mainly depends on the energy input and the holdup of dispersed phase. Higher energy input results in higher holdup of the dispersed phase, the axial mixing of the continuous phase is suppressed, and the true height of mass transfer unit decreases markedly. On the other hand, higher energy input leads to more serious forward mixing of the dispersed phase, so the energy input should be limited. Accordingly the operation conditions were divided into two regions, and empirical correlations for predicting the mass transfer and axial mixing characteristics in different regions with a satisfactory accuracy were suggested. 展开更多
关键词 mass transfer axial mixing extraction column
在线阅读 下载PDF
Rapid, simple and selective determination of 2,4-dinitrophenol by molecularly imprinted spin column extraction coupled with fluorescence detection 被引量:4
5
作者 Min Fang Fang Lei +2 位作者 Jia Zhou Yong-Ning Wu Zhi-Yong Gong 《Chinese Chemical Letters》 SCIE CAS CSCD 2014年第11期1492-1494,共3页
A rapid, simple and selective method based on molecularly imprinted, spin column extraction coupled with fluorescence detection was successfully established for the determination of 2,4-dinitrophenol in serum samples.... A rapid, simple and selective method based on molecularly imprinted, spin column extraction coupled with fluorescence detection was successfully established for the determination of 2,4-dinitrophenol in serum samples. The 2,4-dinitrophenol imprinted polymers exhibited highly selective recognition for the template molecule and the maximum adsorption capacity was 138.9 mg/g. The results indicated that when water is used as the loading solution, only 2,4-dinitrophenol could be adsorbed on the spin column without the remaining structural analogs(2-nitrophenol, 4-nitrophenol and phenol). After eluting with acetonitrile/acetic acid(9/1, v/v), 2,4-dinitrophenol in serum samples could be determined by using the fluorescence spectrometer, based on the fluorescence enhancement of fluorescein by the template molecule. Under the optimal conditions, the spiked recovery ranged from 95.8% to 103.4% and the detection limit was 1 nmol/L. The results confirmed the reliability and practicality of the protocol and revealed a good perspective of this method for biological sample analysis. 展开更多
关键词 Molecularly imprinted solid phase extraction Indirect fluorescence detection Spin column 2 4-Dinitrophenol
原文传递
Design aspect of a novel L-shaped pulsed column for liquid–liquid extraction applications: Energy consumption and the characteristics velocity concept 被引量:3
6
作者 Pouria Amani Elham Mohammadi Sahar Akhgar 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2018年第4期723-730,共8页
This article deals with the evaluation of the consumption of energy for a steady state solvent extraction in a novel L-shaped pulsed sieve-plate column, which is highly required for design and optimization of the peri... This article deals with the evaluation of the consumption of energy for a steady state solvent extraction in a novel L-shaped pulsed sieve-plate column, which is highly required for design and optimization of the periodic flow processes for industrial applications. In this regard, a comprehensive evaluation on the energy consumption in case of a pulsed flow for three different chemical systems is conducted and besides the influence of pulsation intensity, the effect of geometrical parameters including the plate spacing and the plate free area is investigated as well. Moreover, the concept of characteristic velocity models at flooding points is evaluated with respect to the variation of pressure drop along the column at different operational conditions. 展开更多
关键词 Solvent extraction Pulsed plate column Pressure drop Energy consumption Pulsed flow Characteristic velocity
在线阅读 下载PDF
基于增大截面法的框架结构抽柱改造工程技术研究
7
作者 边兆伟 毛冬旭 +3 位作者 张风亮 员作义 成浩 易术春 《陕西建筑》 2024年第3期6-20,共15页
为满足既有建筑物使用功能的要求,需要对改造区域进行抽柱托换加固。本文结合工程实例,分析了采用增大截面法托梁抽柱中所面临的关键技术问题,并提出了相应的解决方案;根据验算结果制定了钢架支撑、梁增大截面和碳纤维片材加固梁板等详... 为满足既有建筑物使用功能的要求,需要对改造区域进行抽柱托换加固。本文结合工程实例,分析了采用增大截面法托梁抽柱中所面临的关键技术问题,并提出了相应的解决方案;根据验算结果制定了钢架支撑、梁增大截面和碳纤维片材加固梁板等详细的加固设计方案,对施工流程和施工技术要点进行了分析,同时为了防止施工过程中钢架支撑不发生屈曲变形和倾覆,保证混凝土结构的安全性,对钢架支撑、框架梁混凝土和钢筋的应变进行了实时监测,监测结果远小于规范限值要求,验证了本次抽柱托换加固方案的合理性和有效性,为类似的托换工程提供了良好的指导作用。 展开更多
关键词 column extraction Support system Construction Technology Strain Monitoring
在线阅读 下载PDF
Optimal design of extractive dividing-wall column using an efficient equation-oriented approach 被引量:1
8
作者 Yingjie Ma Nan Zhang +1 位作者 Jie Li Cuiwen Cao 《Frontiers of Chemical Science and Engineering》 SCIE EI CAS CSCD 2021年第1期72-89,共18页
The extractive dividing-wall column(EDWC)is one of the most efficient technologies for separation of azeotropic or close boiling-point mixtures,but its design is fairly challenging.In this paper we extend the hybrid f... The extractive dividing-wall column(EDWC)is one of the most efficient technologies for separation of azeotropic or close boiling-point mixtures,but its design is fairly challenging.In this paper we extend the hybrid feasible path optimisation algorithm(Ma Y,McLaughlan M,Zhang N,Li J.Computers&Chemical Engineering,2020,143:107058)for such optimal design.The tolerances-relaxation integration method is refined to allow for long enough integration time that can ensure the solution of the pseudo-transient continuation simulation close to the steady state before the required tolerance is used.To ensure the gradient and Jacobian information available for optimisation,we allow a relaxed tolerance for the simulation in the sensitivity analysis mode when the simulation diverges under small tolerance.In addition,valid lower bounds on purity of the recycled entrainer and the vapour flow rate in column sections are imposed to improve computational efficiency.The computational results demonstrate that the extended hybrid algorithm can achieve better design of the EDWC compared to those in literature.The energy consumption can be reduced by more than 20%compared with existing literature report.In addition,the optimal design of the heat pump assisted EDWC is achieved using the improved hybrid algorithm for the first time. 展开更多
关键词 design extractive dividing-wall column equation-oriented optimisation pseudo-transient continuation model hybrid algorithm
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部