Outcomes of a non-diffractive extended depth of focus intraocular lens in patients with well-controlled glaucoma and ocular hypertension
1
作者 Jia-Ru Liu Andrei-Alexandru Szigiato Paul Harasymowycz 《International Journal of Ophthalmology(English edition)》 2025年第1期79-85,共7页
AIM:To assess visual outcomes and satisfaction of a non-diffractive extended depth of focus(EDOF)intraocular lens(IOL)in individuals with ocular hypertension(OHT)and well-controlled mild glaucoma undergoing cataract s... AIM:To assess visual outcomes and satisfaction of a non-diffractive extended depth of focus(EDOF)intraocular lens(IOL)in individuals with ocular hypertension(OHT)and well-controlled mild glaucoma undergoing cataract surgery.METHODS:An investigator-initiated,single-center,prospective,interventional,noncomparative study conducted in Montreal,Canada.The study enrolled 31 patients(55 eyes)with OHT or mild glaucoma who received a non-diffractive EDOF IOL(Acrysof IQ Vivity).Participants underwent sequential cataract surgery with the Vivity IOL.Follow-up evaluations occurred at 1d,1,and 3mo postoperatively,assessing uncorrected distance,intermediate,and near visual acuity.Questionnaires(QUVID:Questionnaire for visual disturbances and IOLSAT:Intraocular lens satisfaction)were administered pre and post-operatively to measure visual disturbances and spectacle independence in various lighting.Safety parameters included intraocular pressure(IOP),glaucoma medications,spherical equivalence,mean deviation and pattern standard deviation or square root of lost variance on Octopus visual field.RESULTS:At 1 and 3mo postoperatively,significant improvements were observed in uncorrected distance and intermediate visual acuity.Spectacle independence was enhanced for distance and intermediate vision,especially in bright light settings.Spectacle-free intermediate vision was improved even in dim lighting.Visual disturbances,particularly glare symptoms,were reduced,and there was a notable decrease in IOP and glaucoma medication burden at 3mo.There was more hazy vision postoperatively with no impact on visual acuity and visual satisfaction.CONCLUSION:The non-diffractive EDOF lens improves distance and intermediate spectacle-free visual function in patients with OHT and well-controlled glaucoma.The findings highlight significant improvements in visual acuity,reduced glare,enhanced spectacle independence,and improved visual performance in different lighting conditions. 展开更多
关键词 extended depth of focus refractive GLAUCOMA ocular hypertension CATARACT intraocular lens
原文传递
Visual Performance of a Polynomial Extended Depth of Focus Intraocular Lens 被引量:1
2
作者 Pavel Stodulka Martin Slovak 《Open Journal of Ophthalmology》 2021年第3期214-228,共15页
<strong>Purpose:</strong> To clinically evaluate a new extended depth of focus intraocular lens (ISOPURE, PhysIOL) with optic design modification based on a unique polynomial concept to improve intermediat... <strong>Purpose:</strong> To clinically evaluate a new extended depth of focus intraocular lens (ISOPURE, PhysIOL) with optic design modification based on a unique polynomial concept to improve intermediate vision while keeping the quality of distance vision equal to a monofocal lens. <strong>Methods:</strong> 18 patients (11 female, 7 male, mean age of 69.4 years) with bilateral cataract and regular corneal astigmatism ≤ 1.0 D underwent bilateral cataract surgery with ISOPURE implantation. Patients were followed for up to 6 months. Measured parameters were uncorrected (UDVA) and corrected distance visual acuity (CDVA), uncorrected (UIVA) and distance-corrected intermediate visual acuity at 80 cm and 66 cm (DCI80VA, DCI66VA) subjective refraction, defocus curve, tolerance of cylinder induction, and contrast sensitivity. The data from all implanted eyes (all-eyes) and a subset only including the first eye implanted for each patient were analysed. <strong>Results:</strong> The mean manifest refraction spherical equivalent (MRSE) decreased from 1.05 D pre-operatively to ?0.15 D at the 4 - 6 month assessment, with 80.6% of eyes within ±0.50 D of emmetropia. At the final follow-up, mean (SD) monocular CDVA was ?0.06 (0.04) logMAR, DCI80VA was 0.18 (0.08) logMAR and DCI66VA was 0.27 (0.13) logMAR. Despite a cylinder induction of ?0.50 D, uncorrected distance visual acuity of 0.02 logMAR was still achieved. <strong>Conclusion:</strong> The ISOPURE intraocular lens provides excellent distance corrected visual acuity for far and intermediate distances along with high contrast sensitivity and good tolerance of residual refractive cylinder. 展开更多
关键词 Intraocular Lens Extended depth of Focus EDOF IOL
在线阅读 下载PDF
Dual-mode liquid-crystal element for polarization imaging with an extended depth of field
3
作者 Xuanyu Wu Xuanguang Wu +6 位作者 Xiaofeng Xu Weiqi Chen Bingyan Wei Sheng Liu Xuetao Gan Jianlin Zhao Peng Li 《Chinese Optics Letters》 2025年第10期26-31,共6页
Extended depth-of-field(DoF)imaging enhances longitudinal clarity but traditionally fails to record polarization information.Here,we propose a liquid-crystal Pancharatnam-Berry(PB)phase element that extends DoF while ... Extended depth-of-field(DoF)imaging enhances longitudinal clarity but traditionally fails to record polarization information.Here,we propose a liquid-crystal Pancharatnam-Berry(PB)phase element that extends DoF while sensing polarization ellipticity.Leveraging cubic-phase-induced defocus-insensitive point spread functions,a 10 cm DoF is achieved in a 10-cm-focal-length 4f system.Linear PB phases enable spin-orbit interactions to detect polarization states,overcoming irreversible polarization loss in conventional methods.This dual-functionality system integrates DoF extension with polarization sensing,enhancing multidimensional imaging capabilities and holding promise for advancing machine vision,microscopic imaging,and optical detection by merging depth clarity with polarization-based object differentiation. 展开更多
关键词 liquid-crystal element polarization imaging extended depth of field multidimensional imaging
原文传递
Combined application of extended depth of field imaging, image stitching and polarized microscopy techniques in identification of Spatholobus suberectus 被引量:9
4
作者 Ying-xian Ma Chayanis Sutcharitchan +4 位作者 Xiao-die Li Qian Meng Xin Wang Shen Ji Ya-jun Cui 《Chinese Herbal Medicines》 CAS 2020年第4期367-374,共8页
Objective:As traditional techniques for microscopic identification of Chinese medicines currently lack objective and high-quality reference images,here we developed a systemic procedure to be used in microscopic ident... Objective:As traditional techniques for microscopic identification of Chinese medicines currently lack objective and high-quality reference images,here we developed a systemic procedure to be used in microscopic identification of Chinese medicines,which would lead to more objective,effective and accurate identification process.Methods:Spatholobi Caulis(Jixueteng in Chinese)was used as the specimen in the development of such procedure.Jixueteng samples were microscopically examined in bright-and dark-field microscopy.Microscopic images were obtained by regular,EDF,and image stitching techniques.Results:The microscopic images of the characteristics in pulverized Jixueteng were captured,thanks to EDF imaging and image stitching techniques which allowed the detailed and full sighting of each characteristic to be obtained simultaneously.Different layers in anatomical transverse section,including cork,phelloderm,cortex,phloem,cambium,xylem and pith,were distinctively observed.Moreover,by comparing images of bright-and dark-field microscopy,birefringent and non-birefringent components could readily be distinguished.Conclusion:With application of the developed procedure,high-definition,panoramic and microscopic images were acquired,which could be used as the reference images for microscopic identification of Chinese medicines. 展开更多
关键词 extended depth of field imaging image stitching microscopic identification polarized light PHARMACOGNOSY spatholobus suberectus Dunn
原文传递
Design of double-zone aspheric diffractive intraocular lens with extended depth of focus 被引量:1
5
作者 Yayan Bian Yongji Liu and Lai Jiang 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第9期77-84,共8页
A double-zone aspheric diffractive intraocular lens (IOL) was designed and manufactured aiming to regain a continuous range of clear vision for pseudophakic presbyopia. After obtaining the IOL structure parameters t... A double-zone aspheric diffractive intraocular lens (IOL) was designed and manufactured aiming to regain a continuous range of clear vision for pseudophakic presbyopia. After obtaining the IOL structure parameters through optimization based on an aphakic model eye, its imaging performances were analyzed in the model eye. The modulation transfer function at 50 cycles/mm remained above 0.29 within ±5° field of view for object distance ranging from 6 to 0.66 m. In addition, the imaging qualities are robust for pupil changes, polychromatic light, and different corneal asphericities. The manufactured IOL exhibits the abilitv to extend depth of focus. 展开更多
关键词 IOL Design of double-zone aspheric diffractive intraocular lens with extended depth of focus
原文传递
Chromatic optical coherence tomography for high-resolution deep tissue imaging
6
作者 SEUNG EON LEE HYEONG SOO NAM +5 位作者 RYEONG HYEON KIM HYUN JUNG KIM JAE YEON SEOK JIN WON KIM YOUNG-JIN KIM HONGKI YOO 《Photonics Research》 2025年第10期2888-2902,共15页
Achieving clear and deep tissue imaging with optical coherence tomography(OCT)necessitates the simultaneous optimization of three critical factors:high resolution,extended depth of focus(DOF),and high signal-tonoise r... Achieving clear and deep tissue imaging with optical coherence tomography(OCT)necessitates the simultaneous optimization of three critical factors:high resolution,extended depth of focus(DOF),and high signal-tonoise ratio(SNR).Conventional OCT systems often compromise one or more of these factors,due to inherent trade-offs in optical design and noise management.To address these limitations,we present a chromatic OCT system that simultaneously optimizes all three parameters.The system achieves an isotropic spatial resolution of 2 to 3μm by leveraging a broad bandwidth light source and high-numerical-aperture optics with a pronounced chromatic focal shift,which enables up to a sevenfold DOF extension.Additionally,a novel noise-gating algorithm suppresses system-inherent noise,sidelobe artifacts,and multiple scattering effects,significantly enhancing the SNR.Comparative simulations and experiments demonstrate that the proposed chromatic OCT outperforms conventional high-resolution systems by maintaining superior resolution and SNR over an extended imaging range.These advancements establish chromatic OCT as a powerful tool for high-resolution,deep tissue imaging in biomedical applications,offering improved diagnostic capabilities. 展开更多
关键词 high resolution imaging isotropic spa noise gating algorithm optical coherence tomography oct necessitates deep tissue imaging extended depth focus chromatic oct system chromatic optical coherence tomography
原文传递
Retinal image quality with multifocal,EDoF,and accommodative intraocular lenses as studied by pyramidal aberrometry 被引量:6
7
作者 Jorge L.Alio Francesco D’Oria +4 位作者 Francesca Toto Joan Balgos Antonio Palazon Francesco Versaci Jorge L.Alio del Barrio 《Eye and Vision》 SCIE CSCD 2021年第1期374-384,共11页
Background:To study and compare the clinical optical image quality following implantation with different premium IOLs by analysing the point spread function(PSF)Strehl ratio using a pyramidal wavefront sensor(PWS)-bas... Background:To study and compare the clinical optical image quality following implantation with different premium IOLs by analysing the point spread function(PSF)Strehl ratio using a pyramidal wavefront sensor(PWS)-based aberrometer.Methods:This study included 194 eyes implanted with:(a)19 AcrySof SA60AT(control group);(b)19 Miniwell;(c)24 LENTIS Mplus LS-313 MF30;(d)33 LENTIS Mplus LS-313 MF15;(e)17 AkkoLens Lumina;(f)31 AT LISA Tri 839MP;(g)20 Precizon Presbyopic;(h)20 AcrySof IQ PanOptix;(i)11 Tecnis Eyhance.Main outcome measures were PSF Strehl ratio,PSF Strehl ratio excluding second-order aberrations(PSFw2),total root mean square(RMS),low-order aberration(LOA)and high-order aberration(HOA)RMS measured by PWS aberrometer.Results:AT LISA Tri had the highest PSFw2 Strehl ratio at both 3.0-and 4.0-mm pupil size(0.52±0.14 and 0.31±0.10;P<0.05),followed by SA60AT(0.41±0.11 and 0.28±0.07)and PanOptix(0.4±0.07 and 0.26±0.04).AT LISA Tri was found to provide a significantly better retinal image quality than PanOptix at both 3.0 mm(P<0.0001)and 4.0 mm(P=0.004).Mplus MF15 was found to be significantly better than Mplus MF30 at both 3.0 mm(P<0.0001)and 4.0 mm(P=0.002).Total RMS,LOA RMS,HOA RMS,PSF Strehl ratio and PSFw2 varied significantly between the studied groups(P<0.001).Conclusions:Far distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens.AT LISA Tri,SA60AT and PanOptix showed the highest values of far distance retinal image quality,while the lowest PSFw2 Strehl ratios were displayed by Miniwell,Mplus MF30 and Precizon Presbyopic. 展开更多
关键词 Cataract surgery Pyramidal aberrometry Multifocal IOL Extended depth of focus Accommodative IOL
原文传递
The effects of premium intraocular lenses on presbyopia treatments 被引量:2
8
作者 Yanan Zhu Yueyang Zhong Yanyan Fu 《Advances in Ophthalmology Practice and Research》 2022年第1期18-27,共10页
Background:Presbyopia has become a global disease affecting the world's aging population.Among various treatments,cataract extraction and intraocular lens(IOL)implantation have become the most popular and common m... Background:Presbyopia has become a global disease affecting the world's aging population.Among various treatments,cataract extraction and intraocular lens(IOL)implantation have become the most popular and common methods of presbyopia correction.During the twentieth century,IOLs have underwent significant innovation and advancements to meet the patients'high demands for functional vision at all distances.Main Text:To meet the increasing needs for excellent near and intermediate vision for daily activities,some premium IOLs with more than one focus have been developed,for example,the refractive MfIOLs,diffractive MfIOLs,extended depth of field(EDOF)IOLs,and accommodating IOLs(AIOLs)were introduced to meet this need.In addition,the add-on MfIOLs have been explored as promising supplementary IOLs for pseudophakic presbyopia.When selecting the MfIOLs,the IOLs'features,patients’characteristics,preoperative eye conditions,and treatment expectations should be considered.Conclusions:In this review,we focus on the multifocal IOLs(MfIOLs)commonly used for presbyopia correction and systematically summarized their optical designs and clinical outcomes.More evidence-based studies are required to provide guidelines for MfIOL selection,provide maximum visual benefits,and develop personalized visual solutions in the future. 展开更多
关键词 PRESBYOPIA Intraocular lens Monofocal intraocular lens Multifocal intraocular lens Extended depth of field intraocular lens Accommodating intraocular lens Clinical outcomes
原文传递
Retinal image quality with multifocal, EDoF, and accommodative intraocular lenses as studied by pyramidal aberrometry
9
作者 Jorge L.Alio Francesco D’Oria +4 位作者 Francesca Toto Joan Balgos Antonio Palazon Francesco Versaci Jorge L.Alio del Barrio 《Eye and Vision》 SCIE CSCD 2023年第6期23-32,共10页
BackgroundTo study and compare the clinical optical image quality following implantation with different premium IOLs by analysing the point spread function (PSF) Strehl ratio using a pyramidal wavefront sensor (PWS)-b... BackgroundTo study and compare the clinical optical image quality following implantation with different premium IOLs by analysing the point spread function (PSF) Strehl ratio using a pyramidal wavefront sensor (PWS)-based aberrometer.MethodsThis study included 194 eyes implanted with: (a) 19 AcrySof SA60AT (control group);(b) 19 Miniwell;(c) 24 LENTIS Mplus LS-313 MF30;(d) 33 LENTIS Mplus LS-313 MF15;(e) 17 AkkoLens Lumina;(f) 31 AT LISA Tri 839MP;(g) 20 Precizon Presbyopic;(h) 20 AcrySof IQ PanOptix;(i) 11 Tecnis Eyhance. Main outcome measures were PSF Strehl ratio, PSF Strehl ratio excluding second-order aberrations (PSFw2), total root mean square (RMS), low-order aberration (LOA) and high-order aberration (HOA) RMS measured by PWS aberrometer.ResultsAT LISA Tri had the highest PSFw2 Strehl ratio at both 3.0- and 4.0-mm pupil size (0.52 ± 0.14 and 0.31 ± 0.10;P < 0.05), followed by SA60AT (0.41 ± 0.11 and 0.28 ± 0.07) and PanOptix (0.4 ± 0.07 and 0.26 ± 0.04). AT LISA Tri was found to provide a significantly better retinal image quality than PanOptix at both 3.0 mm (P < 0.0001) and 4.0 mm (P = 0.004). Mplus MF15 was found to be significantly better than Mplus MF30 at both 3.0 mm (P < 0.0001) and 4.0 mm (P = 0.002). Total RMS, LOA RMS, HOA RMS, PSF Strehl ratio and PSFw2 varied significantly between the studied groups (P < 0.001).ConclusionsFar distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens. AT LISA Tri, SA60AT and PanOptix showed the highest values of far distance retinal image quality, while the lowest PSFw2 Strehl ratios were displayed by Miniwell, Mplus MF30 and Precizon Presbyopic. 展开更多
关键词 Cataract surgery Pyramidal aberrometry Multifocal IOL Extended depth of focus Accommodative IOL