Effect factors of the absorption of the source,air,entrance window,and dead layer of a detector must be considered in the measurement of monoenergetic alpha particles,along with statistical noise and other factors tha...Effect factors of the absorption of the source,air,entrance window,and dead layer of a detector must be considered in the measurement of monoenergetic alpha particles,along with statistical noise and other factors that collectively cause the alpha spectrum to exhibit a well-known low-energy tail.Therefore,the estabUshment of an alpha spectrum detector response function from the perspective of a signaling system must consider the various factors mentioned above.The detector response function is the convolution of an alphaparticle pulse function,two exponential functions,and a Gaussian function,followed by calculation of the parameters of the detector response function using the weighted leastsquares fitting method as proposed in this paper.In our experiment,^(239)Pu alpha spectra were measured by a highresolution,passivated implanted planar silicon(PIPS)detector at 10 levels of vacuum and 10 source-detector distances.The spectrum-fitting results were excellent as evaluated by reduced Chi-square(x^2) and correlation coefficients.Finally,the variation of parameters with vacuum level and source-detector distance was studied.Results demonstrate that σ,τ_1,and τ_2 exhibit no obvious trend of variation with vacuum in the range 2000-20,000 mTorr,and at a confidence level of 95%,the values of τ_1 and τ_2 decline in a similar fashion with source-detector distance by the power exponential function,while the value of a declines linearly.展开更多
Usually, there are several methods, e.g. experiment, interpolation experiment-based, analytic function, and Monte-Carlo simulation, to calculate the response functions in LaBr3(Ce) detectors. In logging applications...Usually, there are several methods, e.g. experiment, interpolation experiment-based, analytic function, and Monte-Carlo simulation, to calculate the response functions in LaBr3(Ce) detectors. In logging applications, the experiment-based methods cannot be adopted because of their limitations. Analytic function has the advantage of fast calculating speed, but it is very difficult to take into account many effects that occur in practical applications. On the contrary, Monte-Carlo simulation can deal with physical and geometric configurations very tactfully. It has a distinct advantage for calculating the functions with complex configurations in borehole. A new application of LaBr3(Ce) detector is in natural gamma-rays borehole spectrometer for uranium well logging. Calculation of response functions must consider a series of physical and geometric factors under complex logging conditions, including earth formations and its relevant parameters, different energies, material and thickness of the casings, the fluid between the two tubes, and relative position of the LaBr3(Ce) crystal to steel ingot at the front of logging tube. The present work establishes Monte-Carlo simulation models for the above-mentioned situations, and then performs calculations for main gamma-rays from natural radio-elements series. The response functions can offer experimental directions for the design of borehole detection system, and provide technique basis and basic data for spectral analysis of natural gamma-rays, and for sonrceless calibration in uranium quantitative interpretation.展开更多
A semi-empirical detector response function (DRF) model of Si (PIN) detector is proposed to fit element Kα and Kβ X-ray spectra, which is based on statistical distribution analytic (SDA) method. The model for ...A semi-empirical detector response function (DRF) model of Si (PIN) detector is proposed to fit element Kα and Kβ X-ray spectra, which is based on statistical distribution analytic (SDA) method. The model for each single peak contains a step function, a Gaussian function and an exponential tail function. Parameters in the model are obtained by weighted nonlinear least-squares fitting method. In the application, six kinds of elements' characteristic X-ray spectra are obtained by Si (PIN) detector, and fitted out by the established DRF model. Reduced chi-square values are at the interval of 1.11-1.25. Other applications of the method are also discussed.展开更多
A semi-empirical detector response function(DRF)model is established to fit characteristic X-ray peaks recorded in Si-PIN spectra,which is mainly composed of four components:a truncated step function,a Gaussian-shaped...A semi-empirical detector response function(DRF)model is established to fit characteristic X-ray peaks recorded in Si-PIN spectra,which is mainly composed of four components:a truncated step function,a Gaussian-shaped full-energy peak,a Gaussian-shaped Si escape peak and an exponential tail.A simple but useful statistical distribution-based analytic method(SDA)is proposed to achieve accurate values of standard deviation for characteristic X-ray peaks.And the values of the model parameters except for the standard deviation are obtained by weighted least-squares fitting of the pulse-height spectra from a number of pure-element samples.A Monte Carlo model is also established to simulate the X-ray measurement setup.The simulated flux spectrum can be transformed by Si-PIN detector response function to real pulse height spectrum as studied in this work.Finally,the fitting result for a copper alloy sample was compared with experimental spectra,and the validity of the present method was demonstrated.展开更多
基金supported by the National Natural Science Foundation of China(Nos.41374130 and 41604154)Opening Foundation of Sichuan Provincial Key Lab of Applied Nuclear Techniques in Geosciences(No.gnzds2014003)the Open Fund of Robot Technology Used for Special Environment Key Laboratory of Sichuan Province(13zxtk04)
文摘Effect factors of the absorption of the source,air,entrance window,and dead layer of a detector must be considered in the measurement of monoenergetic alpha particles,along with statistical noise and other factors that collectively cause the alpha spectrum to exhibit a well-known low-energy tail.Therefore,the estabUshment of an alpha spectrum detector response function from the perspective of a signaling system must consider the various factors mentioned above.The detector response function is the convolution of an alphaparticle pulse function,two exponential functions,and a Gaussian function,followed by calculation of the parameters of the detector response function using the weighted leastsquares fitting method as proposed in this paper.In our experiment,^(239)Pu alpha spectra were measured by a highresolution,passivated implanted planar silicon(PIPS)detector at 10 levels of vacuum and 10 source-detector distances.The spectrum-fitting results were excellent as evaluated by reduced Chi-square(x^2) and correlation coefficients.Finally,the variation of parameters with vacuum level and source-detector distance was studied.Results demonstrate that σ,τ_1,and τ_2 exhibit no obvious trend of variation with vacuum in the range 2000-20,000 mTorr,and at a confidence level of 95%,the values of τ_1 and τ_2 decline in a similar fashion with source-detector distance by the power exponential function,while the value of a declines linearly.
基金supported by Key Laboratory of Radioactive Geology and Exploration Technology Fundamental Science for National Defense(No. 2011RGET04)East China Institute of Technology, and National Natural Science Foundation of China (No. 41074078)
文摘Usually, there are several methods, e.g. experiment, interpolation experiment-based, analytic function, and Monte-Carlo simulation, to calculate the response functions in LaBr3(Ce) detectors. In logging applications, the experiment-based methods cannot be adopted because of their limitations. Analytic function has the advantage of fast calculating speed, but it is very difficult to take into account many effects that occur in practical applications. On the contrary, Monte-Carlo simulation can deal with physical and geometric configurations very tactfully. It has a distinct advantage for calculating the functions with complex configurations in borehole. A new application of LaBr3(Ce) detector is in natural gamma-rays borehole spectrometer for uranium well logging. Calculation of response functions must consider a series of physical and geometric factors under complex logging conditions, including earth formations and its relevant parameters, different energies, material and thickness of the casings, the fluid between the two tubes, and relative position of the LaBr3(Ce) crystal to steel ingot at the front of logging tube. The present work establishes Monte-Carlo simulation models for the above-mentioned situations, and then performs calculations for main gamma-rays from natural radio-elements series. The response functions can offer experimental directions for the design of borehole detection system, and provide technique basis and basic data for spectral analysis of natural gamma-rays, and for sonrceless calibration in uranium quantitative interpretation.
基金Supported by National Natural Science Foundation of China(40974065, 41025015)Scientific and Technological Innovative Team in Sichuan Province(2011JTD0013)"863" Program of China(2012AA063501)
文摘A semi-empirical detector response function (DRF) model of Si (PIN) detector is proposed to fit element Kα and Kβ X-ray spectra, which is based on statistical distribution analytic (SDA) method. The model for each single peak contains a step function, a Gaussian function and an exponential tail function. Parameters in the model are obtained by weighted nonlinear least-squares fitting method. In the application, six kinds of elements' characteristic X-ray spectra are obtained by Si (PIN) detector, and fitted out by the established DRF model. Reduced chi-square values are at the interval of 1.11-1.25. Other applications of the method are also discussed.
基金Supported by National Natural Science Foundation of China(Nos.40974065 and 41025015)Scientific and Technological Innovative Team in Sichuan Province(No.2011JTD0013)"863"Program of China(No.2012AA063501)
文摘A semi-empirical detector response function(DRF)model is established to fit characteristic X-ray peaks recorded in Si-PIN spectra,which is mainly composed of four components:a truncated step function,a Gaussian-shaped full-energy peak,a Gaussian-shaped Si escape peak and an exponential tail.A simple but useful statistical distribution-based analytic method(SDA)is proposed to achieve accurate values of standard deviation for characteristic X-ray peaks.And the values of the model parameters except for the standard deviation are obtained by weighted least-squares fitting of the pulse-height spectra from a number of pure-element samples.A Monte Carlo model is also established to simulate the X-ray measurement setup.The simulated flux spectrum can be transformed by Si-PIN detector response function to real pulse height spectrum as studied in this work.Finally,the fitting result for a copper alloy sample was compared with experimental spectra,and the validity of the present method was demonstrated.