期刊文献+
共找到92篇文章
< 1 2 5 >
每页显示 20 50 100
Diagnosis of electron temperature of copper foil plasmas produced at the Shenguang-II facility
1
作者 Chenglong Zhang Haochen Gu +4 位作者 Yu Dai Ke Fang Yufeng Dong Peng Zhou Yingjun Li 《Chinese Physics B》 2025年第7期433-437,共5页
Warm dense plasmas are crucial for high-energy-density physics and inertial confinement fusion research.Experiments involving laser-irradiated copper(Cu)foil were performed at the Shenguang-II facility.A highly orient... Warm dense plasmas are crucial for high-energy-density physics and inertial confinement fusion research.Experiments involving laser-irradiated copper(Cu)foil were performed at the Shenguang-II facility.A highly oriented pyrolytic graphite crystal spectrometer measured the time-integrated spectral distribution of Cu under varying laser intensities.Using the two-dimensional radiation-hydrodynamics code FLASH and the spectral analysis code FLYCHK,we simulated the temporal evolution of plasma density and temperature distributions,as well as the emission intensities of spectral lines at different temperatures and densities.The simulation results revealed that the two-electron satellite lines(J)and the resonance line(W)emissions of Cu originate predominantly from the radiation region near the critical density surface,with a density range from approximately 0.5 nc to 1.0 nc,and radiate primarily during the laser irradiation period.By analyzing the J/W intensity ratio of the measured spectral lines,we estimated the electron temperatures near the critical-density surface under different laser intensities. 展开更多
关键词 electron temperature crystal spectrometer x-ray spectroscopy
原文传递
Langmuir probe diagnostics in multi-Maxwellian EEDF plasmas
2
作者 YIP Chi-shung JIN Chenyao +1 位作者 JIANG Di ZHANG Wei 《推进技术》 北大核心 2025年第6期254-274,共21页
This article provides a short review on the importance of the detailed analysis of a Langmuir probe I-V trace in a multi-Maxwellian plasma,and discuss proper procedures analyzing Langmuir probe I-V traces in bi-Maxwel... This article provides a short review on the importance of the detailed analysis of a Langmuir probe I-V trace in a multi-Maxwellian plasma,and discuss proper procedures analyzing Langmuir probe I-V traces in bi-Maxwellian and triple-Maxwellian Electron Energy Distribution Function(EEDF)plasmas.Discus⁃sion and demonstration of procedures include the treatment of the ion saturation current,electron saturation cur⁃rent,space-charge effects on the I-V trace,and most importantly how to properly isolate and fit for each electron group present in an I-V trace reflecting a mult-Maxwellian EEDF,as well as how having a multi-Maxwellian EEDF affects the procedures of treating the ion and electron saturation currents.Shortcomings of common improp⁃er procedures are discussed and demonstrated with simulated I-V traces to show how these procedures gives false measurements. 展开更多
关键词 Plasma diagnostics Langmuir probes EEDFs I-V characteristics Electron temperature
原文传递
Development of double-foil soft X-ray array imaging(DSXAI)diagnostic on HL-2A tokamak
3
作者 Hangqi XU Tao LAN +34 位作者 Min XU Zhanhui WANG Lin NIE Jie WU Sen ZHANG Yiming ZU Yi LIU Yunbo DONG Wenzhe MAO Chen CHEN Jiaren WU Pengcheng LU Tianxiong WANG Qilong DONG Yongkang ZHOU Peng DENG Xingkang WANG Zeqi BAI Yuhua HUANG Zian WEI Hai WANG Xiaohui WEN Haiyang ZHOU Chu ZHOU Ahdi LIU Zhengwei WU Jinlin XIE Hong LI Chijin XIAO Weixing DING Wei CHEN Wulyu ZHONG Xuru DUAN Wandong LIU Ge ZHUANG 《Plasma Science and Technology》 2025年第3期30-35,共6页
A 100-channel double-foil soft X-ray array imaging(DSXAI)diagnostic system has been developed for the HL-2A tokamak to obtain tomographic bremsstrahlung emissivity and electron temperature(T_(e)).This system employs a... A 100-channel double-foil soft X-ray array imaging(DSXAI)diagnostic system has been developed for the HL-2A tokamak to obtain tomographic bremsstrahlung emissivity and electron temperature(T_(e)).This system employs a double-foil technique to determine T_(e) by comparing the soft X-ray(SXR)emissivities from the same plasma location through two beryllium(Be)foils of differing thickness.The DSXAI system comprises five photocameras mounted at two different poloidal cross-sections,separated toroidally by 15°,allowing for three distinct poloidal viewing angles.Each photocamera features 20 channels,offering a temporal resolution of approximately 4μs and a spatial resolution of about 8 cm,with no channel overlap.Each photocamera contains two identical optical systems,each defined by an aperture slit and a photodiode array.The double-foil configuration is realized by placing these two optical systems,each with a different Be foil,in close proximity.Initial experimental results demonstrate that the DSXAI diagnostic system performs well,successfully reconstructing 2-dimensional(2D)tomographic SXR emissivity and T_(e) on the HL-2A tokamak.This study provides valuable insights for the future implementation of similar diagnostic systems on fusion reactors like ITER. 展开更多
关键词 double-foil soft X-ray photocamera bremsstrahlung emissivity electron temperature
在线阅读 下载PDF
A comparison among optical emission spectroscopic methods of determining electron temperature in low pressure argon plasmas 被引量:3
4
作者 牛田野 曹金祥 +4 位作者 刘磊 刘金英 王艳 王亮 吕铀 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第9期2757-2763,共7页
In this article, four kinds of optical emission spectroscopic methods of determining electron temperature are used to investigate the relationship between electron temperature and pressure in the cylindrical plasmas o... In this article, four kinds of optical emission spectroscopic methods of determining electron temperature are used to investigate the relationship between electron temperature and pressure in the cylindrical plasmas of dc glow discharges at low pressures in laboratory by measuring the relative intensities of ArI lines at various pressures. These methods are developed respectively on the basis of the Fermi-Dirac model, corona model, and two kinds of electron collision cross section models according to the kinetic analysis. Their theoretical bases and the conditions to which they are applicable are reviewed, and their calculation results and fitting errors are compared with each other. The investigation has indicated that the electron temperatures obtained by the four methods become consistent with each other when the pressure increases in the low pressure argon plasmas. 展开更多
关键词 plasma diagnostics gas discharge optic emission spectroscopy electron temperature
原文传递
Integrated Operating Scenario to Achieve 100-Second, High Electron Temperature Discharge on EAST 被引量:3
5
作者 钱金平 龚先祖 +21 位作者 万宝年 刘甫坤 王茂 徐旵东 胡纯栋 王亮 李二众 曾龙 提昂 沈飚 林士耀 邵林明 臧庆 刘海庆 张斌 孙有文 徐国盛 梁云峰 肖炳甲 胡立群 李建刚 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第5期457-459,共3页
Stationary long pulse plasma of high electron temperature was produced on EAST for the first time through an integrated control of plasma shape, divertor heat flux, particle exhaust, wall conditioning, impurity manage... Stationary long pulse plasma of high electron temperature was produced on EAST for the first time through an integrated control of plasma shape, divertor heat flux, particle exhaust, wall conditioning, impurity management, and the coupling of multiple heating and current drive power. A discharge with a lower single null divertor configuration was maintained for 103 s at a plasma current of 0.4 MA, q95 ≈7.0, a peak electron temperature of 〉4.5 keV, and a central density ne(0)-2.5×10^19 m^-3. The plasma current was nearly non-inductive (Vloop 〈0.05 V, poloidal beta - 0.9) driven by a combination of 0.6 MW lower hybrid wave at 2.45 GHz, 1.4 MW lower hybrid wave at 4.6 GHz, 0.5 MW electron cyclotron heating at 140 GHz, and 0.4 MW modulated neutral deuterium beam injected at 60 kV. This progress demonstrated strong synergy of electron cyclotron and lower hybrid electron heating, current drive, and energy confinement of stationary plasma on EAST. It further introduced an example of integrated "hybrid" operating scenario of interest to ITER and CFETR. 展开更多
关键词 superconducting tokamak high electron temperature long pulse
在线阅读 下载PDF
Measurement of electron density and electron temperature of a cascaded arc plasma using laser Thomson scattering compared to an optical emission spectroscopic approach 被引量:2
6
作者 Yong WANG Cong LI +2 位作者 Jielin SHI Xingwei WU Hongbin DING 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第11期23-30,共8页
As advanced linear plasma sources, cascaded arc plasma devices have been used to generate steady plasma with high electron density, high particle flux and low electron temperature. To measure electron density and elec... As advanced linear plasma sources, cascaded arc plasma devices have been used to generate steady plasma with high electron density, high particle flux and low electron temperature. To measure electron density and electron temperature of the plasma device accurately, a laser Thomson scattering(LTS) system, which is generally recognized as the most precise plasma diagnostic method, has been established in our lab in Dalian University of Technology. The electron density has been measured successfully in the region of 4.5?×10^19m^-3 to7.1?×10^20m^-3 and electron temperature in the region of 0.18 eV to 0.58 eV. For comparison,an optical emission spectroscopy(OES) system was established as well. The results showed that the electron excitation temperature(configuration temperature) measured by OES is significantly higher than the electron temperature(kinetic electron temperature) measured by LTS by up to 40% in the given discharge conditions. The results indicate that the cascaded arc plasma is recombining plasma and it is not in local thermodynamic equilibrium(LTE). This leads to significant error using OES when characterizing the electron temperature in a non-LTE plasma. 展开更多
关键词 laser Thomson scattering optical emission spectroscopy cascaded arc plasma electron density electron temperature electron excitation temperature
在线阅读 下载PDF
Electron temperature diagnostics of aluminium plasma in a z-pinch experiment at the "QiangGuang-1" facility 被引量:2
7
作者 李沫 吴坚 +4 位作者 王亮平 吴刚 韩娟娟 郭宁 邱孟通 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第12期322-326,共5页
Two curved crystal spectrometers are set up on the "QiangGuang-1" generator to measure the z-pinch plasma spectra emitted from planar aluminum wire array loads. Kodak Biomax-MS film and an IRD AXUVHS5# array are emp... Two curved crystal spectrometers are set up on the "QiangGuang-1" generator to measure the z-pinch plasma spectra emitted from planar aluminum wire array loads. Kodak Biomax-MS film and an IRD AXUVHS5# array are employed to record time-integrated and time-resolved free-bound radiation, respectively. The photon energy recorded by each detector is ascertained by using the L-shell lines of molybdenum plasma. Based on the exponential relation between the continuum power and photon energies, the aluminum plasma electron temperatures are measured. For the time-integrated diagnosis, several "bright spots" indicate electron temperatures between (450 eV- 520 eV) ± 35%. And for the time-resolved ones, the result shows that the electron temperature reaches about 800 eV±30% at peak power. The system satisfies the demand of z-pinch plasma electron temperature diagnosis on a - 1 MA facility. 展开更多
关键词 electron temperature CONTINUUM curved crystal spectrometer Z-PINCH
原文传递
Diagnosis of Electronic Excitation Temperature in Surface Dielectric Barrier Discharge Plasmas at Atmospheric Pressure 被引量:2
8
作者 张颖 李杰 +2 位作者 鲁娜 商克峰 吴彦 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第2期123-127,共5页
The electronic excitation temperature of a surface dielectric barrier discharge (DBD) at atmospheric pressure has been experimentally investigated by optical emission spectroscopic measurements combined with numeric... The electronic excitation temperature of a surface dielectric barrier discharge (DBD) at atmospheric pressure has been experimentally investigated by optical emission spectroscopic measurements combined with numerical simulation. Experiments have been carried out to deter- mine the spatial distribution of electric field by using FEM software and the electronic excitation temperature in discharge by calculating ratio of two relative intensities of atomic spectral lines. In this work, we choose seven Ar atomic emission lines at 415.86 nm [(3s^23p^5)5p →(3s^23p^5)4s] and 706.7 nm, 714.7 nm, 738.4 nm, 751.5 nm, 794.8 nm and 800.6 nm [(3s^23p^5)4p → (3s^23p^5)4s] to estimate the excitation temperature under a Boltzmann approximation. The average electron energy is evaluated in each discharge by using line ratio of 337.1 nm (N2(C^3Пu →B3Пg)) to 391.4 nm (N2^+(B2 ∑u^+→ ∑g^+)). Furthermore, variations of the electronic excitation tempera- ture are presented versus dielectric thickness and dielectric materials. The discharge is stable and uniform along the axial direction, and the electronic excitation temperature at the edge of the copper electrode is the largest. The corresponding average electron energy is in the range of 1.6- 5.1 eV and the electric field is in 1.7-3.2 MV/m, when the distance from copper electrode varies from 0 cm to 6 cm. Moreover, the electronic excitation temperature with a higher permittivity leads to a higher dissipated electrical power. 展开更多
关键词 surface dielectric barrier discharge electronic excitation temperature electric field average electron energy dielectric properties
在线阅读 下载PDF
Heat-induced temperature enhancement in the polar summer ionosphere 被引量:1
9
作者 XU Bin CHENG MuSong +4 位作者 XU ZhengWen WU Jun WANG ZhanGe XUE Kun WU Jian 《Advances in Polar Science》 2011年第2期101-110,共10页
Observation data recorded by the European Incoherent Scatter Scientific Association in TromsФ, Norway in August 2009 were analyzed to determine the heating effects in polar summer ionospheric modification experiments... Observation data recorded by the European Incoherent Scatter Scientific Association in TromsФ, Norway in August 2009 were analyzed to determine the heating effects in polar summer ionospheric modification experiments. There are two types of increases in electron temperature: large relative increases in a narrow range near 150 km and greater absolute increases in a wider range at 150-400 km. The percentage increase in temperature linearly increases with heating power, but the rate of increase decreases with increasing pump frequency. A clear two-dimensional distribution was found for the measurement made on August 15, and the beating effects are greater closer to the direction of the geomagnetic field. The heating effects obviously depend on the angle between the heating beam and geomagnetic field; as the angle increases, the heating effect decreases. 展开更多
关键词 Ionosphere heating European Incoherent Scatter Scientific Association electron temperature enhancement polarionosphere
在线阅读 下载PDF
Calculating the electron temperature in the lightning channel by continuous spectrum 被引量:1
10
作者 董向成 陈建宏 +1 位作者 魏秀芳 袁萍 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第12期57-61,共5页
Based on the theory of plasma continuous radiation, the relationship between the emission intensity of bremsstrahlung and recombination radiation and the plasma electron temperature is obtained. During the development... Based on the theory of plasma continuous radiation, the relationship between the emission intensity of bremsstrahlung and recombination radiation and the plasma electron temperature is obtained. During the development process of a return stroke of ground flash, the intensity of continuous radiation spectrum is separated on the basis of the spectrums with obviously different luminous intensity at two moments. The electron temperature of the lightning discharge channel is obtained through the curve fitting of the continuous spectrum intensity. It is found that electron temperature increases with the increase of wavelength and begins to reduce after the peak. The peak temperature of the two spectra is close to 25 000 K. To be compared with the result of discrete spectrum, the electron temperature is fitted by the O I line and N II line of the spectrum respectively. The comparison shows that the high temperature value is in good agreement with the temperature of the lightning core current channel obtained from the ion line information, and the low temperature at the high band closes to the calculation result of the atomic line, at a low band is lower than the calculation of the atomic line, which reflects the temperature of the luminous channel of the outer corona. 展开更多
关键词 lightning spectrum plasma continuous radiation spectral separation electron temperature
在线阅读 下载PDF
Analysis of electron temperature,impurity transport and MHD activity with multi-energy soft x-ray diagnostic in EAST tokamak 被引量:1
11
作者 兰恒 徐国盛 +20 位作者 Kevin TRITZ 颜宁 石同辉 李永亮 王腾飞 王亮 陈竞博 段艳敏 原毅 孙有文 顾帅 臧庆 陈冉 陈良 郑星炜 陈树亮 刘欢 叶扬 汪惠乾 万宝年 the EAST Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第12期15-25,共11页
A new edge tangential multi-energy soft x-ray(ME-SXR) diagnostic with high temporal(≤ 0.1 ms) and spatial(~1 cm) resolution has been developed for a variety of physics topics studies in the EAST tokamak plasma.... A new edge tangential multi-energy soft x-ray(ME-SXR) diagnostic with high temporal(≤ 0.1 ms) and spatial(~1 cm) resolution has been developed for a variety of physics topics studies in the EAST tokamak plasma. The fast edge electron temperature profile(approximately from r a~ 0.6 to the scrape-off layer) is investigated using ME-SXR diagnostic system. The data process was performed by the ideal ‘multi-foil' technique, with no priori assumptions of plasma profiles. Reconstructed ME-SXR emissivity profiles for a variety of EAST experimental scenarios are presented here for the first time. The applications of the ME-SXR for study of the effects of resonant magnetic perturbation on edge localized modes and the first time neon radiating divertor experiment in EAST are also presented in this work. It has been found that neon impurity can suppress the 2/1 tearing mode and trigger a 3/1 MHD mode. 展开更多
关键词 ME-SXR ‘multi-foil' technique electron temperature estimate RMP ELM impurity
在线阅读 下载PDF
Effect of Sample Temperature on Radiation Characteristics of Nanosecond Laser-Induced Soil Plasma
12
作者 Li Wang Yu Zhou +3 位作者 Yuan-xia Fu Li Xu Hao Gong Rong-long 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2019年第6期760-764,I0003,共6页
An Nd:YAG single pulse nanosecond laser of 532 nm wavelength with an 8 ns pulse width was projected on the soil samples collected from the campus of Bengbu College under 1 standard atmospheric pressure. Laser-induced ... An Nd:YAG single pulse nanosecond laser of 532 nm wavelength with an 8 ns pulse width was projected on the soil samples collected from the campus of Bengbu College under 1 standard atmospheric pressure. Laser-induced breakdown spectroscopy at different sample temperatures was achieved. The intensity and signal-to-noise ratio (SNR) changes of different characteristic spectral lines could be analyzed when the sample temperature changes.The evolution of plasma electron temperature and electron density with the sample temperature was analyzed through Boltzmann oblique line method and Stark broadening method.The cause of the radiation enhancement of laser-induced metal plasma was discussed. Experimental results demonstrated that the spectral intensity, SNR, the electron temperature and electron density of plasma are positively related to the sample temperature, and reach saturation at 100℃. 展开更多
关键词 Sample temperature Spectral intensity Signal-to-noise ratio SOIL Electron temperature Electron density Laser-induced breakdown spectroscopy
在线阅读 下载PDF
Diagnosis of Electron,Vibrational and Rotational Temperatures in an Ar/N2 Shock Plasma Jet Produced by a Low Pressure DC Cascade Arc Discharge
13
作者 李聪 张家良 +3 位作者 姚志 吴兴伟 张辰飞 丁洪斌 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第9期875-880,共6页
In this paper, a low pressure Ar/N2 shock plasma jet with clearly multicycle al- ternating zones produced by a DC cascade arc discharge has been investigated by an emission spectral method combined with Abel inversion... In this paper, a low pressure Ar/N2 shock plasma jet with clearly multicycle al- ternating zones produced by a DC cascade arc discharge has been investigated by an emission spectral method combined with Abel inversion analysis. Plasma emission intensity, electron, vi- brational and rotational temperatures of the shock plasma have been measured in the expansion and compression zones. The results indicate that the ranges of the measured electron temperature, vibrational temperature and rotational temperature are 1.1 eV to 1.6 eV, 0.2 eV to 0.7 eV and 0.19 eV to 0.22 eV, respectively, and it is found for the first time that the vibrational and rota- tional temperatures increase while the electron temperature decreases in the compression zones. The electron temperature departs from the vibrational and the rotational temperatures due to non-equilibrium plasma effects. Electrons and heavy particles could not completely exchange energy via collisions in the shock plasma jet under the low pressure of 620 Pa or so. 展开更多
关键词 DC arc torch plasma jet shock wave electron temperature vibrational tem-perature rotational temperature emission spectral diagnosis
在线阅读 下载PDF
Characteristics of wall sheath and secondary electron emission under different electron temperatures in a Hall thruster
14
作者 段萍 覃海娟 +3 位作者 周新维 曹安宁 陈龙 高宏 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第7期510-515,共6页
In this paper, a two-dimensional physical model is established in a Hall thruster sheath region to investigate the influences of the electron temperature and the propellant on the sheath potential drop and the seconda... In this paper, a two-dimensional physical model is established in a Hall thruster sheath region to investigate the influences of the electron temperature and the propellant on the sheath potential drop and the secondary electron emission in the Hall thruster, by the particle-in-cell (PIC) method. The numerical results show that when the electron temperature is relatively low, the change of sheath potential drop is relatively large, the surface potential maintains a stable value and the stability of the sheath is good. When the electron temperature is relatively high, the surface potential maintains a persistent oscillation, and the stability of the sheath reduces. As the electron temperature increases, the secondary electron emission coefficient on the wall increases. For three kinds of propellants (At, Kr, and Xe), as the ion mass increases the sheath potentials and the secondary electron emission coefficients reduce in sequence. 展开更多
关键词 Hall thruster electron temperature SHEATH secondary electron emission
原文传递
Effects of electron temperature on dielectric function and localization of laser beams in underdense collisional plasma
15
作者 夏雄平 蔡泽彬 易林 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第9期295-301,共7页
Effects of electron temperature on dielectric function and localization of laser beams in underdense collisional plasmas are investigated. Simulation results show that the electron temperature has a strong effect on t... Effects of electron temperature on dielectric function and localization of laser beams in underdense collisional plasmas are investigated. Simulation results show that the electron temperature has a strong effect on the dielectric constant and the laser beam localization. It is observed that due to the influence of the electron temperature, the dielectric function presents some interesting and complicated nonlinear variations, and gives rise to the laser beam lo- calization. Moreover, the amplitudes of the beam width and the beam intensity are subjected to continuously oscillatory variation in the region of localization. In addition, the effects of several parameters on the dielectric function and the beam localization are discussed. 展开更多
关键词 underdense collisional plasmas electron temperature dielectric function laser beamlocalization
原文传递
Frequency dependence of electron temperature in hollow cathode-type discharge as measured by several different floating probe methods
16
作者 Shuichi SATO Hiromu KAWANA +1 位作者 Tatsushi FUJIMINE Mikio OHUCHI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第8期50-57,共8页
We measured electron temperatures through a hollow cathode-type discharge tube using several different floating probe methods. This method detected a shift in the floating potential when an AC voltage was applied to a... We measured electron temperatures through a hollow cathode-type discharge tube using several different floating probe methods. This method detected a shift in the floating potential when an AC voltage was applied to a probe through an intermediary blocking capacitor. The shift in the floating potential is described as a function of the electron temperature and the applied AC voltage. In this study, the effects of the frequency and waveform on the electron temperatures were systematically investigated. The electron temperature measured when using the floating probe method with applied sinusoidal and triangular voltages was lower than that measured with an applied rectangular voltage.The value in the high frequency range was close to that of the tail electron temperature. 展开更多
关键词 electrostatic probe Langmuir probe floating potential electron temperature SHEATH
在线阅读 下载PDF
Machine learning application to predict the electron temperature on the J-TEXT tokamak
17
作者 Jiaolong DONG Jianchao LI +8 位作者 Yonghua DING Xiaoqing ZHANG Nengchao WANG Da LI Wei YAN Chengshuo SHEN Ying HE Xiehang REN Donghui XIA 《Plasma Science and Technology》 SCIE EI CAS CSCD 2021年第8期47-52,共6页
The reliability of diagnostic systems in tokamak plasma is of great significance for physics researches or fusion reactor.When some diagnostics fail to detect information about the plasma status,such as electron tempe... The reliability of diagnostic systems in tokamak plasma is of great significance for physics researches or fusion reactor.When some diagnostics fail to detect information about the plasma status,such as electron temperature,they can also be obtained by another method:fitted by other diagnostic signals through machine learning.The paper herein is based on a machine learning method to predict electron temperature,in case the diagnostic systems fail to detect plasma temperature.The fully-connected neural network,utilizing back propagation with two hidden layers,is utilized to estimate plasma electron temperature approximately on the J-TEXT.The input parameters consist of soft x-ray emission intensity,electron density,plasma current,loop voltage,and toroidal magnetic field,while the targets are signals of electron temperature from electron cyclotron emission and x-ray imaging crystal spectrometer.Therefore,the temperature profile is reconstructed by other diagnostic signals,and the average errors are within 5%.In addition,generalized regression neural network can also achieve this function to estimate the temperature profile with similar accuracy.Predicting electron temperature by neural network reveals that machine learning can be used as backup means for plasma information so as to enhance the reliability of diagnostics. 展开更多
关键词 neural network PLASMA electron temperature J-TEXT tokamak
在线阅读 下载PDF
The Electron Temperature Estimation Using Soft X-Ray Imaging in HT-7 Tokamak
18
作者 甄香君 胡立群 +5 位作者 万宝年 陈忠勇 石跃江 林士耀 丁永华 周立武 《Plasma Science and Technology》 SCIE EI CAS CSCD 2006年第2期147-150,共4页
In order to estimate the electron temperature soft x-ray imaging diagnostics using a double filter technique has been developed in the HT-7 tokamak. The chosen thicknesses of the Be foil are 12.5 μm and 70 μm, respe... In order to estimate the electron temperature soft x-ray imaging diagnostics using a double filter technique has been developed in the HT-7 tokamak. The chosen thicknesses of the Be foil are 12.5 μm and 70 μm, respectively. In this article both the main design of the diagnostic configuration and the method to estimate the electron temperature are presented. The results agree with those estimated from the soft x-ray pulse height analyzer (PHA). The main causes of systematic error have also been investigated. 展开更多
关键词 different foils technique soft x-ray electron temperature tokamak plasma
在线阅读 下载PDF
Electron Temperature Measurement by Floating Probe Method Using AC Voltage
19
作者 Satoshi NODOMI Shuichi SATO Mikio OHUCHI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第11期1089-1094,共6页
This study presents a novel floating probe method to measure electron temperatures using a hollow cathode-type discharge tube. The proposed method detects a shift in the floating potential when an AC voltage is applie... This study presents a novel floating probe method to measure electron temperatures using a hollow cathode-type discharge tube. The proposed method detects a shift in the floating potential when an AC voltage is applied to a probe through an intermediary blocking capacitor. The shift in the floating potential is described as a function of the electron temperature and the applied AC voltage. The floating probe method is simpler than the Langmuir probe method because it does not require the measurement of volt-ampere characteristics. As the input AC voltage increases, the electron temperature converges. The electron temperature measured using the floating probe method with an applied sinusoidal voltage shows a value close to the first (tail) electron temperature in the range of the floating potential. 展开更多
关键词 electrostatic probe Langmuir probe floating potential electron temperature SHEATH
在线阅读 下载PDF
Integrated data analysis on the electron temperature profile of HL-2A with the Bayesian probability inference method
20
作者 Wenan PAN Tianbo WANG +10 位作者 Zhibin WANG Yonghao YANG Hao WU Geert VERDOOLAEGE Zengchen YANG Chunhua LIU Wenping GUO Bingli LI Zijie LIU Wenbin WU Min XU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第5期237-252,共16页
Data analysis on tokamak plasmas is mainly based on various diagnostic systems,which are usually modularized and independent of each other.This leads to a large amount of data not being fully and effectively exploited... Data analysis on tokamak plasmas is mainly based on various diagnostic systems,which are usually modularized and independent of each other.This leads to a large amount of data not being fully and effectively exploited so that it is not conducive to revealing the deep physical mechanism.In this work,Bayesian probability inference with machine learning methods have been applied to the electron cyclotron emission and Thomson scattering diagnostic systems on HL-2A/2M,and the effects of integrated data analysis(IDA)on the electron temperature of HL-2A with Bayesian probability inference are demonstrated.A program is developed to infer the whole electron temperature profile with a confidence interval,and the program can be applied in online analysis.The IDA results show that the full profile of the electron temperature can be obtained and the diagnostic information is more comprehensive and abundant with IDA.The inference models for electron temperature analysis are established and the developed programs will serve as an experimental data analysis tool for HL-2A/2M in the near future. 展开更多
关键词 electron cyclotron emission Thomson scattering electron temperature Bayesian inference
在线阅读 下载PDF
上一页 1 2 5 下一页 到第
使用帮助 返回顶部