期刊文献+
共找到116篇文章
< 1 2 6 >
每页显示 20 50 100
Therapeutic effects of low-intensity transcranial focused ultrasound stimulation on ischemic stroke in rats:An in vivo evaluation using electrical impedance tomography
1
作者 Jiecheng Guo Sixuan He +4 位作者 Li Yan Lei Wang Xuetao Shi Huijing Hu Le Li 《Neural Regeneration Research》 2026年第3期1183-1190,共8页
Although previous studies have demonstrated that transcranial focused ultrasound stimulation protects the ischemic brain,clear criteria for the stimulation time window and intensity are lacking.Electrical impedance to... Although previous studies have demonstrated that transcranial focused ultrasound stimulation protects the ischemic brain,clear criteria for the stimulation time window and intensity are lacking.Electrical impedance tomography enables real-time monitoring of changes in cerebral blood perfusion within the ischemic brain,but investigating the feasibility of using this method to assess post-stroke rehabilitation in vivo remains critical.In this study,ischemic stroke was induced in rats through middle cerebral artery occlusion surgery.Transcranial focused ultrasound stimulation was used to treat the rat model of ischemia,and electrical impedance tomography was used to measure impedance during both the acute stage of ischemia and the rehabilitation stage following the stimulation.Electrical impedance tomography results indicated that cerebral impedance increased after the onset of ischemia and decreased following transcranial focused ultrasound stimulation.Furthermore,the stimulation promoted motor function recovery,reduced cerebral infarction volume in the rat model of ischemic stroke,and induced the expression of brain-derived neurotrophic factor in the ischemic brain.Our results also revealed a significant correlation between the impedance of the ischemic brain post-intervention and improvements in behavioral scores and infarct volume.This study shows that daily administration of transcranial focused ultrasound stimulation for 20 minutes to the ischemic hemisphere 24 hours after cerebral ischemia enhanced motor recovery in a rat model of ischemia.Additionally,our findings indicate that electrical impedance tomography can serve as a valuable tool for quantitatively evaluating rehabilitation after ischemic stroke in vivo.These findings suggest the feasibility of using impedance data collected via electrical impedance tomography to clinically assess the effects of rehabilitatory interventions for patients with ischemic stroke. 展开更多
关键词 animal model brain stimulation electrical impedance tomography evaluation impedance noninvasive treatment real-time monitoring REHABILITATION STROKE transcranial focused ultrasound stimulation
暂未订购
Application of electrical impedance tomographyguided PEEP titration in acute respiratory distress syndrome patients with intra-abdominal hypertension
2
作者 Hui Wen Maiying Fan +5 位作者 Junliang Xiao Zhiqun Liu Xiaohua Liu Shuzhen Mao Xiaotong Han Fengling Ning 《World Journal of Emergency Medicine》 2026年第1期70-75,共6页
BACKGROUND:Individualized positive end-expiratory pressure(PEEP)titration is a crucial technique in mechanical ventilation therapy for acute respiratory distress syndrome(ARDS)patients with intra-abdominal hypertensio... BACKGROUND:Individualized positive end-expiratory pressure(PEEP)titration is a crucial technique in mechanical ventilation therapy for acute respiratory distress syndrome(ARDS)patients with intra-abdominal hypertension(IAH).This study aimed to evaluate the eff ectiveness of electrical impedance tomography(EIT)-guided PEEP titration in this population.METHODS:This prospective study enrolled 36 ARDS patients,including 22 patients with IAH and 14 without IAH.All the patients underwent EIT-guided PEEP titration at the intersection point between alveolar overdistension and collapse during a decremental PEEP trial.The changes in pulmonary ventilation distribution,respiratory mechanics and hemodynamics during the titration process were observed.RESULTS:After EIT-guided PEEP titration was performed,the PEEP,peak inspiratory pressure and plateau pressure increased significantly(P<0.05).Furthermore,no significant differences were observed in respiratory system compliance,tidal volume,driving pressure,or the 4*DP+RR index between the two groups(P>0.05).The mechanical power increased in the non-IAH(NIAH)group after PEEP titration(P<0.05).Ventilation in gravity-dependent lung regions significantly increased(P<0.05),and the oxygenation index(PaO2/FiO2)improved signifi cantly(P<0.05)in both groups.However,blood pressure,heart rate,respiratory rate,central venous pressure,and lactate levels did not signifi cantly change.In the IAH group,the PaO2/FiO2 ratio improved less than that in the NIAH group did(P<0.05).CONCLUSION:In our study,individualized PEEP titration guided by EIT improved oxygenation in ARDS patients with concomitant IAH without signifi cantly aff ecting hemodynamics.The presence of IAH may limit the improvement of oxygenation during EIT-guided PEEP titration. 展开更多
关键词 Acute respiratory distress syndrome Positive end-expiratory pressure electrical impedance tomography Intra-abdominal pressure
暂未订购
Electrical impedance tomography: from technical innovations to bedside clinical solutions
3
作者 Nanxia Xuan Baoping Tian +3 位作者 Lan Ying Xiajing Cao Danqiong Wang Gensheng Zhang 《World Journal of Emergency Medicine》 2025年第5期497-502,共6页
Electrical impedance tomography(EIT)is a non-invasive imaging modality that generates real-time images by measuring tissue bioimpedance.It works by applying current and collecting voltage data to reconstruct images of... Electrical impedance tomography(EIT)is a non-invasive imaging modality that generates real-time images by measuring tissue bioimpedance.It works by applying current and collecting voltage data to reconstruct images of electrical conductivity,refl ecting tissue properties.[1]We aim to off er a comprehensive guide to the fundamental technology behind EIT and to explore its clinical applications across both pulmonary and extrapulmonary domains. 展开更多
关键词 tissue bioimpedance current application electrical conductivityrefl voltage data electrical impedance tomography electrical impedance tomography eit real time images non invasive imaging
暂未订购
Effects of noise on fluidized bed characteristics measurements by electrical capacitance tomography
4
作者 Kai Huang Chunlei Pei +4 位作者 Shuanghe Meng Wuqiang Yang Hua Li Mao Ye Jinlong Gong 《Chinese Journal of Chemical Engineering》 2025年第3期219-233,共15页
Noise is inevitable in electrical capacitance tomography(ECT)measurements.This paper describes the influence of noise on ECT performance for measuring gas-solids fluidized bed characteristics.The noise distribution is... Noise is inevitable in electrical capacitance tomography(ECT)measurements.This paper describes the influence of noise on ECT performance for measuring gas-solids fluidized bed characteristics.The noise distribution is approximated by the Gaussian distribution and added to experimental capacitance data with various intensities.The equivalent signal strength(Ф)that equals the signal-to-noise ratio of packed beds is used to evaluate noise levels.Results show that the Pearson correlation coefficient,which indicates the similarity of solids fraction distributions over pixels,increases with Ф,and reconstructed images are more deteriorated at lower Ф.Nevertheless,relative errors for average solids fraction and bubble size in each frame are less sensitive to noise,attributed to noise compromise caused by the process of pixel values.These findings provide useful guidance for assessing the accuracy of ECT measurements of multiphase flows. 展开更多
关键词 Noise electrical capacitance tomography Fluidized bed Signal-to-noise ratio MEASUREMENT
在线阅读 下载PDF
Application of high-density electrical resistivity tomography in backfilling effectiveness of quarries:A case study of Liuyao Village quarry in Huaibei City,Anhui Province
5
作者 XU Guangrui LIU Lijia HAN Jiangtao 《Global Geology》 2025年第4期231-239,共9页
Evaluation of backfilling effectiveness plays a crucial role in the geological environment management and restoration of abandoned open-pit quarries,providing a scientific basis for subsequent greening efforts.Backfil... Evaluation of backfilling effectiveness plays a crucial role in the geological environment management and restoration of abandoned open-pit quarries,providing a scientific basis for subsequent greening efforts.Backfill soil,predominantly composed of silty clay,demonstrates high water retention capacity and elevated moisture content,leading to a pronounced resistivity contrast with the bedrock exposed by quarrying activities.To investigate the distribution of backfill soil subsurface and assess backfilling effectiveness in the study area,this study conducted a comprehensive geophysical investigation utilizing the high-density electrical resistivity tomography(ERT).A total of 19 ERT survey lines were deployed across three distinct areas in Liuyao Village,Huaibei City,Anhui Province,China.The inversion results,derived from both two-dimensional(2D)and three-dimensional(3D),reveal distinct electrical properties of the subsurface materials:the backfill soil layer shows low resistivity features,the fill stone layer exhibits medium to high resistivity,and the bedrock shows the highest resistivity.The 2D inversion results,from the data measured using the Wenner array effectively capture the spatial distribution and structural features of the backfill soil layer.The findings indicate a gradual east-west thinning of the clay layer within the quarry.Furthermore,the northern pit area exhibits a uniform distribution of backfill soil layer,indicative of effective backfilling operations.In contrast,the southern pit area lacks a well-defined clay layer,suggesting suboptimal backfilling effectiveness. 展开更多
关键词 high-density electrical resistivity tomography Wenner array backfilling effectiveness backfill soil
在线阅读 下载PDF
Advances in electrical impedance tomography-based brain imaging 被引量:16
6
作者 Xi-Yang Ke Wei Hou +7 位作者 Qi Huang Xue Hou Xue-Ying Bao Wei-Xuan Kong Cheng-Xiang Li Yu-Qi Qiu Si-Yi Hu Li-Hua Dong 《Military Medical Research》 SCIE CAS CSCD 2022年第6期705-726,共22页
Novel advances in the field of brain imaging have enabled the unprecedented clinical application of various imaging modalities to facilitate disease diagnosis and treatment. Electrical impedance tomography(EIT) is a f... Novel advances in the field of brain imaging have enabled the unprecedented clinical application of various imaging modalities to facilitate disease diagnosis and treatment. Electrical impedance tomography(EIT) is a functional imaging technique that measures the transfer impedances between electrodes on the body surface to estimate the spatial distribution of electrical properties of tissues. EIT offers many advantages over other neuroimaging technologies,which has led to its potential clinical use. This qualitative review provides an overview of the basic principles,algorithms, and system composition of EIT. Recent advances in the field of EIT are discussed in the context of epilepsy,stroke, brain injuries and edema, and other brain diseases. Further, we summarize factors limiting the development of brain EIT and highlight prospects for the field. In epilepsy imaging, there have been advances in EIT imaging depth,from cortical to subcortical regions. In stroke research, a bedside EIT stroke monitoring system has been developed for clinical practice, and data support the role of EIT in multi-modal imaging for diagnosing stroke. Additionally, EIT has been applied to monitor the changes in brain water content associated with cerebral edema, enabling the early identification of brain edema and the evaluation of mannitol dehydration. However, anatomically realistic geometry,inhomogeneity, cranium completeness, anisotropy and skull type, etc., must be considered to improve the accuracy of EIT modeling. Thus, the further establishment of EIT as a mature and routine diagnostic technique will necessitate the accumulation of more supporting evidence. 展开更多
关键词 electrical impedance tomography(EIT) Brain diseases Tissue impedance Microelectrode array
原文传递
The Effect of Sparger Geometry on Gas Bubble Flow Behaviors Using Electrical Resistance Tomography 被引量:13
7
作者 靳海波 M. Wang R. A. Williams 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2006年第1期127-131,共5页
By electrical resistance tomography (ERT) the cross sectional profiles of gas hold-up in a φ56mm bubble column are obtained with four designs of gas sparger. The effect of sparger geometry on the bubble distribution ... By electrical resistance tomography (ERT) the cross sectional profiles of gas hold-up in a φ56mm bubble column are obtained with four designs of gas sparger. The effect of sparger geometry on the bubble distribution is re-vealed by applying a sensitivity conjugated gradients reconstruction method (SCG). Experimental results show that over-all hold-up obtained by ERT is generally in good agreement with those measured with the pressure transducer and the ERT system produces informative evidence that the radial profiles of hold-up is very similar to the sparger design in the lower section of bubble column. Meanwhile, the rise velocity of bubble swarm and the Sauter mean bubble size are evaluated using ERT based on dynamic gas disengagement theory. The experimental results are in good agreement with correlations and conventional estimation obtained using pressure transmitter methods. 展开更多
关键词 bubble column flow behavior electrical resistance tomography
在线阅读 下载PDF
Lung Ventilation Functional Monitoring Based on Electrical Impedance Tomography 被引量:9
8
作者 陈晓艳 王化祥 +1 位作者 赵波 石小累 《Transactions of Tianjin University》 EI CAS 2009年第1期7-12,共6页
Medically, electrical impedance tomography (EIT) is a relatively inexpensive, safe, non-invasive and portable technique compared with computerized tomography (CT) and magnetic resonance imaging (MRI). In this pa... Medically, electrical impedance tomography (EIT) is a relatively inexpensive, safe, non-invasive and portable technique compared with computerized tomography (CT) and magnetic resonance imaging (MRI). In this paper, EIT_TJU_ II system is developed including both the data collection system and image reconstruction algo- rithm. The testing approach of the system performance, including spatial resolution and sensitivity, is described through brine tank experiments. The images of the thorax physical model verify that the system can reconstruct the interior resistivity distribution. Finally, the lung ventilation functional monitoring in vivo is realized by EIT, and the visualized images indicate that the configuration and performance of EIT_TJU_ II system are feasible and EIT is a promising technique in clinical monitoring application. 展开更多
关键词 electrical impedance tomography (EIT) lung ventilation image reconstruction spatial resolution sensitivity
暂未订购
Application of Electrical Capacitance Tomography to the Concentration Measurement in a Cyclone Dipleg 被引量:5
9
作者 孙猛 刘石 +1 位作者 李志宏 雷兢 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2008年第4期635-639,共5页
Accurate solid concentration measurement plays a key role in the process industry. Measurements analyzed offline can be used to estimate process efficiencies, to identify problems in a flow, and to validate computatio... Accurate solid concentration measurement plays a key role in the process industry. Measurements analyzed offline can be used to estimate process efficiencies, to identify problems in a flow, and to validate computational models. Online measurements can be used for active control. Electrical capacitance tomography (ECT) is a unique measuring technique with great potential in multiphase flow measurement. Experimental studies are carried out on a solid concentration measurement in a cyclone separator dipleg, using ECT. In this experiment eight electrodes are selected for the ECT sensor that is placed on the straight tube of the dipleg. The fluctuating characteristics according to the screw feeder and the effect of the airflow rate from the top of the cyclone are analyzed. The feasibility andreliability of the method are verified by the experimental results. 展开更多
关键词 electrical capacitance tomography concentration measurement cyclone separator dipleg gas-solid two-phase flow
在线阅读 下载PDF
Void Fraction Measurement in Oil-Gas Transportation Pipeline Using an Improved Electrical Capacitance Tomography System 被引量:5
10
作者 牛刚 贾志海 王经 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2004年第4期476-481,共6页
To measure the void fraction online in oil-gas pipeline, an improved electrical capacitance tomography (ECT) system has been designed. The capacitance sensor with new structure has twelve internal electrodes and overc... To measure the void fraction online in oil-gas pipeline, an improved electrical capacitance tomography (ECT) system has been designed. The capacitance sensor with new structure has twelve internal electrodes and overcomes the influence of the pipe wall. The data collection system is improved by using high performance IC (integrated circuit). Static tests of bubble flow, stratified flow and annular flow regime are carried out. Measurements are taken on bubble flow, stratified flow and slug flow. Results show that the new ECT system performs well on void fraction measurement of bubble flow and stratified flow, but the error of measurement for slug flow is more than 10%. 展开更多
关键词 electrical capacitance tomography void fraction MEASUREMENT oil-gas transportation
在线阅读 下载PDF
Nonlinear inversion for electrical resistivity tomography based on chaotic DE-BP algorithm 被引量:5
11
作者 戴前伟 江沸菠 董莉 《Journal of Central South University》 SCIE EI CAS 2014年第5期2018-2025,共8页
Nonlinear resistivity inversion requires efficient artificial neural network(ANN)model for better inversion results.An evolutionary BP neural network(BPNN)approach based on differential evolution(DE)algorithm was pres... Nonlinear resistivity inversion requires efficient artificial neural network(ANN)model for better inversion results.An evolutionary BP neural network(BPNN)approach based on differential evolution(DE)algorithm was presented,which was able to improve global search ability for resistivity tomography 2-D nonlinear inversion.In the proposed method,Tent equation was applied to obtain automatic parameter settings in DE and the restricted parameter Fcrit was used to enhance the ability of converging to global optimum.An implementation of proposed DE-BPNN was given,the network had one hidden layer with 52 nodes and it was trained on 36 datasets and tested on another 4 synthetic datasets.Two abnormity models were used to verify the feasibility and effectiveness of the proposed method,the results show that the proposed DE-BP algorithm has better performance than BP,conventional DE-BP and other chaotic DE-BP methods in stability and accuracy,and higher imaging quality than least square inversion. 展开更多
关键词 electrical resistivity tomography nonlinear inversion differential evolution back propagation network Tent map
在线阅读 下载PDF
Reconstruction of electrical capacitance tomography images based on fast linearized alternating direction method of multipliers for two-phase flow system 被引量:4
12
作者 Chongkun Xia Chengli Su +1 位作者 Jiangtao Cao Ping Li 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2016年第5期597-605,共9页
Electrical capacitance tomography(ECT)has been applied to two-phase flow measurement in recent years.Image reconstruction algorithms play an important role in the successful applications of ECT.To solve the ill-posed ... Electrical capacitance tomography(ECT)has been applied to two-phase flow measurement in recent years.Image reconstruction algorithms play an important role in the successful applications of ECT.To solve the ill-posed and nonlinear inverse problem of ECT image reconstruction,a new ECT image reconstruction method based on fast linearized alternating direction method of multipliers(FLADMM)is proposed in this paper.On the basis of theoretical analysis of compressed sensing(CS),the data acquisition of ECT is regarded as a linear measurement process of permittivity distribution signal of pipe section.A new measurement matrix is designed and L1 regularization method is used to convert ECT inverse problem to a convex relaxation problem which contains prior knowledge.A new fast alternating direction method of multipliers which contained linearized idea is employed to minimize the objective function.Simulation data and experimental results indicate that compared with other methods,the quality and speed of reconstructed images are markedly improved.Also,the dynamic experimental results indicate that the proposed algorithm can ful fill the real-time requirement of ECT systems in the application. 展开更多
关键词 electrical capacitance tomography Image reconstruction Compressed sensing Alternating direction method of multipliers Two-phase flow
在线阅读 下载PDF
An adaptive electrical resistance tomography sensor with flow pattern recognition capability 被引量:4
13
作者 WANG Pai LI Yang-bo +2 位作者 WANG Mei QIN Xue-bin LIU Lang 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第3期612-622,共11页
The all traditional electrical resistance tomography (ERT) sensors have a static structure, which cannot satisfy the intelligent requirements for adaptive optimization to ERT sensors that is subject to flow pattern ch... The all traditional electrical resistance tomography (ERT) sensors have a static structure, which cannot satisfy the intelligent requirements for adaptive optimization to ERT sensors that is subject to flow pattern changes during the real-time detection of two-phase flow. In view of this problem, an adaptive ERT sensor with a dynamic structure is proposed. The electrodes of the ERT sensor are arranged in an array structure, the flow pattern recognition technique is introduced into the ERT sensor design and accordingly an ERT flow pattern recognition method based on signal sparsity is proposed. This method uses the sparse representation of the signal to express the sampling voltage of the ERT system as a sparse combination and find its sparse solution to achieve the classification of different flow patterns. With the introduction of flow identification information, the sensor has an intelligent function of adaptively and dynamically adapting the sensor structure according to the real-time flow pattern change. The experimental results show that the sensor can automatically identify four typical flow patterns: core flow, bubble flow, laminar flow and circulation flow with recognition rates of 91%, 93%, 90% and 88% respectively. For different flow patterns, the dynamically optimized sensor can significantly improve the quality of ERT image reconstruction. 展开更多
关键词 electrical resistance tomography adaptive sensor sparse representation flow pattern identification
在线阅读 下载PDF
Design of Parallel Electrical Resistance Tomography System for Measuring Multiphase Flow 被引量:3
14
作者 董峰 许聪 +1 位作者 张志强 任尚杰 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2012年第2期368-379,共12页
ERT(electrical resistance tomography) is effective method for visualization of multiphase flows,offering some advantages of rapid response and low cost,so as to explore the transient hydrodynamics.Aiming at this targe... ERT(electrical resistance tomography) is effective method for visualization of multiphase flows,offering some advantages of rapid response and low cost,so as to explore the transient hydrodynamics.Aiming at this target,a fully programmable and reconfigurable FPGA(field programmable gate array)-based Compact PCI(peripheral component interconnect) bus linked sixteen-channel ERT system has been presented.The data acquisition system is carefully designed with function modules of signal generator module;Compact PCI transmission module and data processing module(including data sampling,filtering and demodulating).The processing module incorporates a powerful FPGA with Compact PCI bus for communication,and the measurement process management is conducted in FPGA.Image reconstruction algorithms with different speed and accuracy are also coded for this system.The system has been demonstrated in real time(1400 frames per second for 50 kHz excitation) with signal-noise-ratio above 62 dB and repeatability error below 0.7%.Static experiments have been conducted and the images manifested good resolution relative to the actual object distribution.The parallel ERT system has provided alternative experimental platform for the multiphase flow measurements by the dynamic experiments in terms of concentration and velocity. 展开更多
关键词 electrical resistance tomography data acquisition compact peripheral component interconnect field programmable gate array digital filter digital demodulation
在线阅读 下载PDF
Flame Imaging in Meso-scale Porous Media Burner Using Electrical Capacitance Tomography 被引量:5
15
作者 陈琪 刘石 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2012年第2期329-336,共8页
This study was conducted to investigate the characteristics of meso-scale combustion.The technique of electrical capacitance tomography(ECT) was used to locate flame position and monitor the effect corresponding to va... This study was conducted to investigate the characteristics of meso-scale combustion.The technique of electrical capacitance tomography(ECT) was used to locate flame position and monitor the effect corresponding to varied air/fuel ratio in a meso-scale combustor.Combustion phenomena including igniting,quenching and unsteady combustion have been visualized using ECT.The method of metallization protecting ECT sensor from high temperature damage and the novel calibration method adapted to ECT monitoring of unknown permittivity flame have been shown to be successful.At the same time,electrical nature of combustion and dielectric characteristics of hy-drocarbon flame were studied.The relationship between flame permittivity and state parameters of combustion gas was demonstrated preliminarily. 展开更多
关键词 electr:ical capacitance tomography meso-scale burner COMBUSTION flame permittivity
在线阅读 下载PDF
Use of 3-D magnetic resonance electrical impedance tomography in detecting human cerebral stroke: a simulation study 被引量:2
16
作者 高诺 朱善安 贺斌 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE EI CAS CSCD 2005年第5期438-445,共8页
We have developed a new three dimensional (3-D) conductivity imaging approach and have used it to detect human brain conductivity changes corresponding to acute cerebral stroke. The proposed Magnetic Resonance Electri... We have developed a new three dimensional (3-D) conductivity imaging approach and have used it to detect human brain conductivity changes corresponding to acute cerebral stroke. The proposed Magnetic Resonance Electrical Impedance Tomography (MREIT) approach is based on the J-Substitution algorithm and is expanded to imaging 3-D subject conductivity distribution changes. Computer simulation studies have been conducted to evaluate the present MREIT imaging approach. Simulations of both types of cerebral stroke, hemorrhagic stroke and ischemic stroke, were performed on a four-sphere head model. Simulation results showed that the correlation coefficient (CC) and relative error (RE) between target and estimated conductivity distributions were 0.9245±0.0068 and 8.9997%±0.0084%, for hemorrhagic stroke, and 0.6748±0.0197 and 8.8986%±0.0089%, for ischemic stroke, when the SNR (signal-to-noise radio) of added GWN (Gaussian White Noise) was 40. The convergence characteristic was also evaluated according to the changes of CC and RE with different iteration numbers. The CC increases and RE decreases monotonously with the increasing number of iterations. The present simulation results show the feasibility of the proposed 3-D MREIT approach in hemorrhagic and ischemic stroke detection and suggest that the method may become a useful alternative in clinical diagnosis of acute cerebral stroke in humans. 展开更多
关键词 Magnetic Resonance electrical Impedance tomography CONDUCTIVITY Acute cerebral stroke Hemorrhagic stroke Ischemic stroke Current density imaging
暂未订购
Dynamic Visualization Approach of the Multiphase Flow Using Electrical Capacitance Tomography 被引量:1
17
作者 王泽璞 陈琪 +2 位作者 王雪瑶 李志宏 韩振兴 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2012年第2期380-388,共9页
Identifying the flow patterns is vital for understanding the complicated physical mechanisms in multiphase flows.For this purpose,electrical capacitance tomography(ECT) technique is considered as a promising visualiza... Identifying the flow patterns is vital for understanding the complicated physical mechanisms in multiphase flows.For this purpose,electrical capacitance tomography(ECT) technique is considered as a promising visualization method for the flow pattern identification,in which image reconstruction algorithms play an important role.In this paper,a generalized dynamic reconstruction model,which integrates ECT measurement information and physical evolution information of the objects of interest,was presented.A generalized objective functional that simultaneously considers the spatial constraints,temporal constraints and dynamic evolution information of the objects of interest was proposed.Numerical simulations and experiments were implemented to evaluate the feasibility and efficiency of the proposed algorithm.For the cases considered in this paper,the proposed algorithm can well reconstruct the flow patterns,and the quality of the reconstructed images is improved,which indicates that the proposed algorithm is competent to reconstruct the flow patterns in the visualization of multiphase flows. 展开更多
关键词 electrical capacitance tomography VISUALIZATION flow pattern identification dynamic reconstruction algorithm
在线阅读 下载PDF
Voidage measurement based on genetic algorithm and electrical capacitance tomography 被引量:1
18
作者 王微微 王保良 +1 位作者 黄志尧 李海青 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第12期1441-1445,共5页
A new voidage measurement method based on electrical capacitance tomography (ECT) technique, Genetic Algo- rithm (GA) and Partial Least Square (PLS) method was proposed. The voidage measurement model, linear capacitan... A new voidage measurement method based on electrical capacitance tomography (ECT) technique, Genetic Algo- rithm (GA) and Partial Least Square (PLS) method was proposed. The voidage measurement model, linear capacitance combi- nation, was developed to measure on-line voidage. GA and PLS method were used to determine the coefficients of the voidage measurement model. GA was used to explore the optimal capacitance combination which gave significant contribution to the voidage measurement. PLS method was applied to determine the weight coefficient of the contribution of each capacitance to the voidage measurement. Flow pattern identification result was introduced to improve the voidage measurement accuracy. Experi- mental results showed that the proposed voidage measurement method is effective and that the measurement accuracy is satis- factory. 展开更多
关键词 VOIDAGE Two-phase flow Genetic Algorithm (GA) electrical capacitance tomography (ECT)
在线阅读 下载PDF
Visualization Detection of Solid-Liquid Two-Phase Flow in Filling Pipeline by Electrical Capacitance Tomography Technology 被引量:1
19
作者 Ningbo Jing Mingqiao Li +3 位作者 Lang Liu Yutong Shen Peijiao Yang Xuebin Qin 《Computer Modeling in Engineering & Sciences》 SCIE EI 2022年第4期465-476,共12页
During mine filling,the caking in the pipeline and the waste rock in the filling slurry may cause serious safety accidents such as pipe blocking or explosion.Therefore,the visualization of the innermine filling of the... During mine filling,the caking in the pipeline and the waste rock in the filling slurry may cause serious safety accidents such as pipe blocking or explosion.Therefore,the visualization of the innermine filling of the solid-liquid two-phase flow in the pipeline is important.This paper proposes a method based on capacitance tomography for the visualization of the solid-liquid distribution on the section of a filling pipe.A feedback network is used for electrical capacitance tomography reconstruction.This reconstruction method uses radial basis function neural network fitting to determine the relationship between the capacitance vector and medium distribution error.In the reconstruction process,the error in the linear back projection is removed;thus,the reconstruction problem becomes an accurate linear problem.The simulation results showthat the reconstruction accuracy of this algorithm is better than that of many traditional algorithms;furthermore,the reconstructed image artifacts are fewer,and the phase distribution boundary is clearer.This method can help determine the location and size of the caking and waste rock in the cross section of the pipeline more accurately and has great application prospects in the visualization of filling pipelines in mines. 展开更多
关键词 electrical capacitance tomography mine backfilling visualization detection image reconstruction radial basis function neural network
在线阅读 下载PDF
Electrode models in electrical impedance tomography 被引量:1
20
作者 WANG M. 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第12期1386-1393,共8页
This paper presents different views on electrode modelling, which include electrode electrochemistry models for modelling the effects of electrode-electrolyte interface, electric field electrode models for modelling e... This paper presents different views on electrode modelling, which include electrode electrochemistry models for modelling the effects of electrode-electrolyte interface, electric field electrode models for modelling electrode geometry, and electrode models for modelling the effects of electrode common mode voltage and double layer capacitance. Taking the full electrode models into consideration in electrical impedance tomography (EIT) will greatly help the optimised approach to a good solution and further understanding of the measurement principle. 展开更多
关键词 electrical impedance tomography (EIT) ELECTROCHEMISTRY Electrode modelling
在线阅读 下载PDF
上一页 1 2 6 下一页 到第
使用帮助 返回顶部