期刊文献+
共找到11篇文章
< 1 >
每页显示 20 50 100
A new method of electric energy metering considering harmonic responsibility 被引量:1
1
作者 ZHU Si-wei TIAN Ming-xing +1 位作者 LI Jun GAO Yun-bo 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2020年第3期244-250,共7页
Aiming at the shortcomings of the existing electric energy metering method,combining with the harmonic responsibility analysis model based on the reference impedance method and the idea of apparent power decomposition... Aiming at the shortcomings of the existing electric energy metering method,combining with the harmonic responsibility analysis model based on the reference impedance method and the idea of apparent power decomposition in IEEE Std 1459-2010 standard,two new metering indicators—billing active power and billing power factor are defined.A new electric energy metering method is proposed and its specific implementation steps are given.The simulation model is built in Matlab/Simulink,and three different examples are set up.Using the simulation data,the various metering indicators need to be examined by the existing electric energy metering method and the new electric energy metering method are calculated.The calculation results show that the new electric energy metering method not only overcomes the shortcomings of the existing electric energy metering method,but also is very easy to be popularized and applied. 展开更多
关键词 electric energy metering harmonic responsibility billing active power billing power factor
在线阅读 下载PDF
Use of online electrical conductivity meter to monitor cold decomposition of carnallite 被引量:1
2
作者 王晓波 侯元昇 李辉林 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2015年第2期185-189,共5页
Online control of the ratio of carnallite to water is a key to achieve a fully continuous and automatic potash produc tion. By monitoring carnallite cold decomposition process using online conductivity meter, the rela... Online control of the ratio of carnallite to water is a key to achieve a fully continuous and automatic potash produc tion. By monitoring carnallite cold decomposition process using online conductivity meter, the relationship between the conduc tivity and the control parameters was analyzed based on the data collected online. The results show that the conductivity regu larly varies with a general trend of decrease after an initial increase when the ratio of mineral to water is adjusted. There are certain rules satisfying cubic polynomial regression equation. When the ratio of mineral to water is larger than 0. 6, with the a mount of carnallite increased by 10%, the conductivity decreases by 0. 28%-0. 45% accordingly and the relative deviation is less than 0. 5%. The value of electrical conductivity has stabilized when the density of liquid increased to 1.27 g/cm3, namely, the solution reaches saturation. It has proved that the methods can be employed for online monitoring the ratio of carnallite to water during carnallite cold decomposition and the precise control has an important value for reference and application. 展开更多
关键词 electrical conductivity meter CARNALLITE cold decomposition
在线阅读 下载PDF
Research on the Recognition Method of Electric Energy Meter Lead Title based on the Fuzzy Image Processing 被引量:1
3
作者 WeiCun FAN Yujie LI 《International Journal of Technology Management》 2015年第6期125-127,共3页
This article puts forward an automatic recognition algorithm of electric energy meter lead seals: firstly, the image will be histogram equalization, smoothing, binaryzation pretreatment, then according to the image c... This article puts forward an automatic recognition algorithm of electric energy meter lead seals: firstly, the image will be histogram equalization, smoothing, binaryzation pretreatment, then according to the image characteristics of text changes, the system can quickly and accurately segment image from complex background, finally the system extract different dimension and the feature of English and Arabia using digital projection transform coefficient method and to identify the corresponding number by BP neural network, solves the problem of automatic recognition of electric energy meter lead sealing. 展开更多
关键词 Fuzzy recognition Lead Sealing BP neural network electric Energy meter
在线阅读 下载PDF
Design of PLC Centralized Meter Reading System
4
作者 Yu Tian 《International Journal of Technology Management》 2013年第4期17-19,共3页
With the increasing development of urban housing construction and the rapid expansion of the number of inhabitants and independent electric energy meter, a variety of tariff systems are launched, meter reading meterin... With the increasing development of urban housing construction and the rapid expansion of the number of inhabitants and independent electric energy meter, a variety of tariff systems are launched, meter reading metering becomes increasingly complex, and the traditional manual meter reading is already hard to adapt to new changes. This thesis studies the design of a centralized meter reading system. This program applies PLC technology for information transfer, which guarantees the stability of system carrier communication. This system is composed of electric energy meter, collector, concentrator and other hardware, as well as communication and management software of collection copies system. It is characterized by functions of power data collection, centralization, remote transmission, distance control, electricity analysis, line loss calculation, integrated query, and time-sharing billing. Its promotion and application will necessarily provide important technical means for power supply, property and urban utilities to improve their modernized and automatic management level. 展开更多
关键词 PLC RS485 electric energy meter Centralized meter reading system.
在线阅读 下载PDF
Function and Function of Uplink Communication Port Expansion Device of Metering Automation Terminal
5
作者 LIZhaoxi YANGMing LUGuocai 《外文科技期刊数据库(文摘版)工程技术》 2022年第3期169-173,共5页
The automation technology of electric energy measurement covers all levels of electric energy measurement points. The electric energy data acquisition of power users has realized remote automatic acquisition. The tool... The automation technology of electric energy measurement covers all levels of electric energy measurement points. The electric energy data acquisition of power users has realized remote automatic acquisition. The tool for remote automatic collection of electric energy data is various metering automation terminals installed on the site. The data transmission of the automation terminal depends on various communication channels. When the field signal strength is insufficient and the communication module of the metering automation terminal cannot work normally, the terminal is offline and the data collection fails. At this time, it is necessary to solve the problem of insufficient signal through other methods, ensure the real-time communication of the terminal. This paper will introduce a technology to enhance the communication ability of terminal communication module, and illustrate the whole picture of the device through practical cases. 展开更多
关键词 electric energy metering automation technology metering automation terminal uplink communication expansion device
原文传递
How to Do Well in Power Metering Management in Power Supply Station
6
作者 XU Xiaran XU Xiayang 《外文科技期刊数据库(文摘版)经济管理》 2021年第8期023-026,共6页
In recent years, in order to achieve further development, the State Grid has further increased the intelligent management of measurement assets with the construction of electric energy information collection as the co... In recent years, in order to achieve further development, the State Grid has further increased the intelligent management of measurement assets with the construction of electric energy information collection as the core and the construction of intelligent warehouse as the pillar, and taken active measures to further increase the application of the monitoring system in daily life, work and operation. In this way, the internal assets of the power enterprise are effectively controlled in an all-round way during the actual operation process, so as to further enable the related work of measurement management to be more healthy and orderly and develop continuously. 展开更多
关键词 power supply station electric energy metering ADMINISTRATION
原文传递
Training Load Monitoring Algorithms on Highly Sub-Metered Home Electricity Consumption Data 被引量:3
7
作者 Mario Berges Ethan Goldman +1 位作者 H. Scott Matthews Lucio Soibelman 《Tsinghua Science and Technology》 SCIE EI CAS 2008年第S1期406-411,共6页
The growing interest in energy-efficient buildings is driving changes in investment, design, and occupant behavior. To better focus cost and resource conservation efforts, electricity consumption feedback can be used ... The growing interest in energy-efficient buildings is driving changes in investment, design, and occupant behavior. To better focus cost and resource conservation efforts, electricity consumption feedback can be used to provide motivation, guidance, and verification. Disaggregating by end-use helps both consumers and producers to identify targets for conservation. While hardware-based sub-metering is costly and labor-intensive, non-intrusive load monitoring (NILM) is capable of gathering detailed energy-use data with minimal equipment cost and installation time. However, variations in measurements between metering devices complicate the process of compiling the necessary appliance profiles. Future work involves the devel-opment of NILM algorithms using sensor fusion and detailed appliance-level data gathered from a highly-sensed house currently being constructed near Pittsburgh, Pennsylvania. 展开更多
关键词 electricity metering FEEDBACK energy conservation non-intrusive load monitoring
原文传递
Costs and Benefits of Smart Grids on Liberalized Markets 被引量:3
8
作者 Marek Adamec Pavel Pavlatka Oldrich Stary 《Journal of Electronic Science and Technology》 CAS 2012年第1期22-28,共7页
The discussion about smart grid (SG) implementation is mostly focused on pilot projects. These projects are necessary for mapping of particular technical devices of advanced metering management (AMM) which is need... The discussion about smart grid (SG) implementation is mostly focused on pilot projects. These projects are necessary for mapping of particular technical devices of advanced metering management (AMM) which is needed for successful SG and whole functional SG system operation. According to our opinion, for the next step of SG implementation, the participation of effective market design would be quite necessary. In other words, pilot project which is operated regardless to the market conditions and special SG tariff is incomplete and could be irrelevant for further evaluation of feasibility. With regard to above mentioned facts, the detailed cost-benefit-analysis (CBA) is needed to establish the correct methodology for evaluation of SG implementation effectiveness. Related aspects are mentioned and discussed in this paper, in which the particular cost and benefits as well as feedback that occurs as the reaction on implementation are summarized and quantified. 展开更多
关键词 Advanced metering management electricity market REGULATION smart grid system approach.
在线阅读 下载PDF
Consistency analysis of accelerated degradation mechanism based on gray theory
9
作者 Yunxia Chen Hongxia Chen +2 位作者 Zhou Yang Rui Kang Yi Yang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2014年第2期322-331,共10页
A fundamental premise of an accelerated testing is that the failure mechanism under elevated and normal stress levels should remain the same. Thus, verification of the consistency of failure mechanisms is essential du... A fundamental premise of an accelerated testing is that the failure mechanism under elevated and normal stress levels should remain the same. Thus, verification of the consistency of failure mechanisms is essential during an accelerated testing. A new consistency analysis method based on the gray theory is pro- posed for complex products. First of all, existing consistency ana- lysis methods are reviewed with a focus on the comparison of the differences among them. Then, the proposed consistency ana- lysis method is introduced. Two effective gray prediction models, gray dynamic model and new information and equal dimensional (NIED) model, are adapted in the proposed method. The process to determine the dimension of NIED model is also discussed, and a decision rule is expanded. Based on that, the procedure of ap- plying the new consistent analysis method is developed. Finally, a case study of the consistency analysis of a reliability enhancement testing is conducted to demonstrate and validate the proposed method. 展开更多
关键词 enhancement test mechanism consistency gray the-ory smart electricity meter.
在线阅读 下载PDF
Research on Intelligent Power Management System for Student Dormitory based on CAN Bus
10
作者 Xie Hong 《International Journal of Technology Management》 2013年第2期110-112,共3页
This paper analyzes the actual situation of the electricity management about student apartments, and design intelligent energy student housing management system based on CAN bus. The system uses the field level, the u... This paper analyzes the actual situation of the electricity management about student apartments, and design intelligent energy student housing management system based on CAN bus. The system uses the field level, the underlying management level and upper management level three management system. Field level with a dedicated energy metering chip AD7755 and STM32F103 microcontroller with A/D conversion function as the core, to achieve real-time power measurement; via CAN bus timing or random read live energy data for monitoring electricity consumption of the apartment, investigate abnormal electricity, thus effectively limiting the students to use electrical power to achieve the modernization and automation of power management solutions student apartments. 展开更多
关键词 CAN bus electric energy metering student apartments
在线阅读 下载PDF
Planting uniformity performance of motor-driven maize precision seeding systems
11
作者 Shuo Yang Changyuan Zhai +4 位作者 Yuanyuan Gao Hanjie Dou Xueguan Zhao Yakai He Xiu Wang 《International Journal of Agricultural and Biological Engineering》 SCIE CAS 2022年第5期101-108,共8页
Low accuracy planting uniformity affects yield.Seed meter type and forward speed typically interfere with the planting uniformity accuracy of motor-driven seeding systems.Two types of maize precision planters equipped... Low accuracy planting uniformity affects yield.Seed meter type and forward speed typically interfere with the planting uniformity accuracy of motor-driven seeding systems.Two types of maize precision planters equipped with motor-driven planting systems are investigated in this study to ascertain the rule of planting uniformity in both simulated and field speeds.The simulated speed increases from 5 to 12 km/h at a 1 km/h interval in a laboratory environment.The test results show that the quality of feed index(QTFI)of the two planters decreased by 16.79%and 9.88%.This is primarily attributed to the increase in the miss index(MISS)by 11.62%and 9.70%,respectively.The field speed was set to four levels from 5 to 12 km/h in a field environment.The plant spacing scatter distribution results were analyzed,and the results of the two planters indicated that the average positive difference of the two planters linearly increased with the forward speed,and the negative difference of the two planters did not exhibit a linear correlation.The number of positive moving average points was 2.49 times greater than that of the negative moving average points of the finger pick-up maize precision planter,and 4.49 times in the air-suction maize precision planter.The results indicated that the increase of the positive difference of plant spacing is the major effect factor in the field planting uniformity of the two motor-driven maize precision planters.In addition,the plant spacing corresponded to the distribution frequency of the two planters in field was close to the target seed spacing of 25 cm with a max coefficient of variation(CV)of 21.55%and 20.66%,respectively,and those plant spacing values corresponded to max distribution frequency of the two planters at the four level field speeds were(24.69±0.63)cm and(25.63±0.32)cm,respectively.However,the multiples index(MUL)changed randomly affected by the increasing speed.The research results provide a direction for the optimization design of motor-driven maize precision planters. 展开更多
关键词 electric drive metering planting uniformity maize precision planting quality evaluation
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部