期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Measurement of Intraocular Pressure after LASIK by Dynamic Contour Tonometry
1
作者 刘磊 雷澄 +1 位作者 李新宇 董洁玉 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第3期372-373,377,共3页
Changes of corneal properties induced by laser in situ keratomileusis (LASIK) results in low inaccurate intraocular pressure (IOP) readings by Goldmann applanation tonometry (GAT). Before and after LASIK, the ap... Changes of corneal properties induced by laser in situ keratomileusis (LASIK) results in low inaccurate intraocular pressure (IOP) readings by Goldmann applanation tonometry (GAT). Before and after LASIK, the applied value of IOP, measured by dynamic contour tonometry (DCT) in comparison to GAT, was evaluated. Before and 1, 4 weeks after LASIK, the IOP in 30 cases (60 eyes) was measured by GAT and DCT respectively. The obtained results were statistically processed by SPSSll. 5 statistical software. The results showed that central corneal thickness (CCT) could affect GAT measurements but not DCT measurements. The comparison of IOP one and 4 weeks after LASIK revealed that the readings from GAT was separately decreased by 5.00±1.12 and 5.45±1.13 mmHg as compared with those before LASIK, while those from DCT had no significant difference. It was concluded that LASIK-induced changes of CCT could influence the accuracy of GAT measurements, but had no influence on those from DCT. DCT was more beneficial to the measurements of IOP in normal eyes and those subject to LASIK surgery. 展开更多
关键词 dynamic contour tonometry Goldmann applanation tonometry intraocular pressure laser in situ keratomileusis
暂未订购
Dependence of dynamic contour and Goldmann applanation tonometries on peripheral corneal thickness
2
作者 Federico Saenz-Frances Claudia Sanz-Pozo +6 位作者 Lara Borrego-Sanz Luis Ja?ez Laura MoralesFernandez Jose Maria Martinez-de-la-Casa Julian Garcia-Sanchez Julian Garcia-Feijoo Enrique Santos-Bueso 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第10期1521-1527,共7页
AIM:To determine the effects of peripheral corneal thickness(PCT)on dynamic contour tonometry(DCT)and Goldmann applanation tonometry(GAT).METHODS:A cross-sectional study.We created a software which calculates ... AIM:To determine the effects of peripheral corneal thickness(PCT)on dynamic contour tonometry(DCT)and Goldmann applanation tonometry(GAT).METHODS:A cross-sectional study.We created a software which calculates the corneal contour(CC)as a function of the radius from the corneal apex to each pixel of the contour.The software generates a central circumference with a radius of 1 mm and the remainder of the cornea is segmented in 5 rings concentric with corneal apex being its diameter not constant around the corneal circumference as a consequence of the irregular CC but keeping constant the diameter of each ring in each direction of the contour.PCT was determined as the mean thickness of the most eccentric ring.Locally weighted scatterplot smoothing(LOWESS)regression was used to determine the pattern of the relationship between PCT and both DCT and GAT respectively.Thereafter,two multivariable linear regression models were constructed.In each of them,the dependant variable was intraocular pressure(IOP)as determined using GAT and DCT respectively.In both of the models the predictive variable was PCT though LOWESS regression pattern was used to model the relationship between the dependant variables and the predictor one.Age and sex were also introduced control variables along with their first-degree interactions with PCT.Main outcome measures include amount of IOP variation explained through regression models(R2)and regression coefficients(B).RESULTS:Subjects included 109 eyes of 109 healthy individuals.LOWESS regression suggested that a 2nd-degree polynomial would be suitable to model the relationshipbetween both DCT and GAT with PCT.Hence PCT was introduced in both models as a linear and quadratic term.Neither age nor sex nor interactions were statistically significant in both models.For GAT model,R2was 17.14%(F=9.02;P=0.0002),PCT linear term B was-1.163(95%CI:-1.163,-0.617).PCT quadratic term B was 0.00081(95%CI:0.00043,0.00118).For DCT model R2was 14.28%(F=9.29;P=0.0002),PCT linear term B was-0.712(95%CI:-1.052,-0.372),PCT quadratic term was B=0.0005(95%CI:0.0003,0.0007).CONCLUSION:DCT and GAT measurements are conditioned by PCT though this effect,rather than linear,follows a2nd-degree polynomial pattern. 展开更多
关键词 Goldmann applanation tonometry dynamic contour tonometry peripheral corneal thickness corneal thickness
原文传递
Dynamic Contour Tonometry,Tono-Pen XL^(■),and Goldmann Applanation Tonometry in Comparison to Intracameral Intraocular Pressure(IOP)Measurements in Patients with Corneal Pathologies
3
作者 Matthias Neuburger Juliane GroBwendt +6 位作者 Sonja Lautebach Philip Maier Florian Birnbaum Daniel Bohringer Jens Funk Jens Friedrich Jordan Thomas Reinhard 《Open Journal of Ophthalmology》 2014年第2期46-55,共10页
Purpose: The accuracy of Goldmann applanation tonometry (GAT) has been shown to depend on several biomechanical properties of the cornea. Newer tonometry devices (e.g., the Dynamic Contour Tonometer PASCAL? [DCT] and ... Purpose: The accuracy of Goldmann applanation tonometry (GAT) has been shown to depend on several biomechanical properties of the cornea. Newer tonometry devices (e.g., the Dynamic Contour Tonometer PASCAL? [DCT] and the Tono-Pen? XL [TP]) have been designed to accurately measure intraocular pressure (IOP) independent of corneal thickness (CCT) and pathology. This study investigates the influence of corneal pathologies on the accuracy of these IOP measuring devices, and compares this accuracy to that of direct intracameral IOP measurement. Methods: 8 eyes of 8 patients suffering from corneal pathologies scheduled for penetrating keratoplasty, and 10 eyes of 10 patients scheduled for cataract surgery (control group) were examined. Before surgery, the anterior chamber was cannulated at the temporal corneal limbus. In a closed system, the intraocular pressure (IOP) was directly set to 10, 20, and 30 mmHg with a manometric water column. Intraocular pressure measurements taken by GAT, DCT, and TP were compared to intracameral measurements obtained by a precision reference pressure sensor. Results: Control group: All three methods showed good agreement with the intracameral readings (mean deviation of all three devices, -0.9 mmHg). Group with corneal pathologies: The TP yielded the most exact IOP values in the group with corneal pathologies when taking all diagnoses into account. The mean deviations from the intracameral IOP measurements were -0.9 mmHg ± 3.2 mmHg (mean ± SD) for TP, -2.9 mmHg ± 3.3 mmHg for GAT, and -5.0 mmHg ± 7.9 mmHg for DCT. For bullous keratopathy, the most exact IOP readings were obtained by the TP (mean deviation -0.2 mmHg ± 3.5 mmHg). The TP and GAT devices underestimated IOP in the patients with Fuchs’ endothelial dystrophy;all 3 devices underestimated adjusted IOP after keratoplasty. DCT showed the greatest deviations from adjusted IOP in the case of non-herpetic scars. In the control group, none of the devices showed a statistically relevant dependency on CCT. Nevertheless, in the group with corneal pathologies, only TP showed no dependency on CCT. Conclusion: Our results suggest that the Tono-Pen XL? is the most accurate measurement device to determine IOP in patients with corneal pathologies, especially in patients suffering from corneal edema (bullous keratopathy). GAT yielded surprisingly exact IOP values in patients suffering from irregular corneal surface. DCT showed a high degree of deviation from the adjusted IOP, and should not be used to determine IOP in corneas with the disorders listed here. 展开更多
关键词 KERATOPLASTY IOP Measurement Goldmann Applanation Tonometry dynamic contour Tonometry Tono-Pen XL^(■)
暂未订购
Medical images application of contour extraction based on Hermite splines contour model 被引量:1
4
作者 陈曾胜 周康源 +1 位作者 胡跃辉 李传富 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2006年第6期702-706,共5页
Active Contour Model or Snake model is an efficient method by which the users can extract the object contour of Region Of Interest (ROI). In this paper, we present an improved method combining Hermite splines curve ... Active Contour Model or Snake model is an efficient method by which the users can extract the object contour of Region Of Interest (ROI). In this paper, we present an improved method combining Hermite splines curve and Snake model that can be used as a tool for fast and intuitive contour extraction. We choose Hermite splines curve as a basic function of Snake contour curve and present its energy function. The optimization of energy minimization is performed hy Dynamic Programming technique. The validation results are presented, comparing the traditional Snake model and the HSCM, showing the similar performance of the latter. We can find that HSCM can overcome the non-convex constraints efficiently. Several medical images applications illustrate that Hermite Splines Contour Model (HSCM) is more efficient than traditional Snake model. 展开更多
关键词 hermite splines contour model HSCM Snake model dynamic programming contour extraction
在线阅读 下载PDF
Impact of corneal parameters on intraocular pressure measurements in different tonometry methods 被引量:6
5
作者 Aleksandra Zakrzewska Marta P.Wi?cek Anna Machalińska 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第12期1853-1858,共6页
AIM: To evaluate the impact of central corneal thickness(CCT) and corneal curvature on intraocular pressure(IOP) measurements performed by three different tonometers. METHODS: IOP in 132 healthy eyes of 66 participant... AIM: To evaluate the impact of central corneal thickness(CCT) and corneal curvature on intraocular pressure(IOP) measurements performed by three different tonometers. METHODS: IOP in 132 healthy eyes of 66 participants was measured using three different tonometry techniques: Goldmann applanation tonometer(GAT), Pascal dynamic contour tonometer(DCT), and ICare rebound tonometer(RT). CCT and corneal curvature were assessed. RESULTS: In healthy eyes, DCT presents significantly higher values of IOP than GAT(17.34±3.69 and 15.27±4.06 mm Hg, P<0.0001). RT measurements are significantly lower than GAT(13.56±4.33 mm Hg, P<0.0001). Compared with GAT, DCT presented on average 2.51 mm Hg higher values in eyes with CCT<600 μm and 0.99 mm Hg higher results in eyes with CCT≥600 μm. The RT results were lower on average by 1.61 and 1.95 mm Hg than those obtained by GAT, respectively. Positive correlations between CCT in eyes with CCT<600 μm were detected for all IOP measurement techniques, whereas a similar relationship was not observed in eyes with thicker corneas. A correlation between IOP values and keratometry in the group with CCT<600 μm was not detected with any of the tonometry methods. In thicker corneas, a positive correlation was found for GAT and mean keratometry values(R=0.369, P=0.005). CONCLUSION: The same method should always be chosen for routine IOP control, and measurements obtained by different methods cannot be compared. All analysed tonometry methods are dependent on CCT;thus, CCT should be taken into consideration for both diagnostics and monitoring. 展开更多
关键词 intraocular pressure Goldmann applanation tonometer Pascal dynamic contour tonometer ICare rebound tonometer central corneal thickness corneal curvature healthy individuals
原文传递
Method for predicting motion artifacts of plasma display panels
6
作者 张宇宁 Teunissen Kees +1 位作者 雷威 张晓兵 《Journal of Southeast University(English Edition)》 EI CAS 2007年第1期43-46,共4页
A simulation method is proposed to predict the motion artifacts of plasma display panels (PDPs). The method simulates the behavior of the human vision system when perceiving moving objects. The simulation is based o... A simulation method is proposed to predict the motion artifacts of plasma display panels (PDPs). The method simulates the behavior of the human vision system when perceiving moving objects. The simulation is based on the measured temporal light properties of the display for each gray level and each phosphor. Both the effect of subfield arrangement and phosphor decay are involved. A novel algorithm is proposed to improve the calculation speed. The simulation model manages to predict the appearance of the motion image perceived by a human with a still image. The results are validated by a set of perceptual evaluation experiments. This rapid and accurate prediction of motion artifacts enables objective characterization of the PDP performance in this aspect. 展开更多
关键词 plasma display panels motion artifacts dynamic false contour motion blur
在线阅读 下载PDF
THE NONLINEAR INTERACTION OF VORTEX RINGS WITH A FREE SURFACE
7
作者 叶取源 C.K.Chu 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 1997年第2期120-129,共10页
Nonlinear interactions of vortex rings with a free surface are considered in an incompressible, ideal fluid using the vortex contour dynamics technique and the boundary integral equation method. The flow is axisymmetr... Nonlinear interactions of vortex rings with a free surface are considered in an incompressible, ideal fluid using the vortex contour dynamics technique and the boundary integral equation method. The flow is axisymmetric and the vorticity is linearly distributed in the vortex. Effects of the gravity and the surface tension as well as the initial geometric parameter of the vortex on the interaction process are investigated in considerable detail. The interaction process may be divided into three major stages: the vortex free-traveling stage, the collision stage, and the vortex stretching and rebounding stage. Time evolutions of both the vortex and free surface under various conditions are provided and analyzed. Two kinds of waves exist on the free surface during interaction. In a special case where the gravity and surface tension are very weak or the vortex is very strong, an electric-bulb-like 'cavity' is formed an the free surface and the vortex is trapped in the 'cavity' for quite a. long time, resulting in a large amount, of fluid above the mean fluid surface. 展开更多
关键词 vortex ring vortex dynamics contour dynamics nonlinear free surface
在线阅读 下载PDF
CONTOUR DYNAMICS FOR VORTEX MOTION INFLUENCED BY THE CORIOLIS FORCE
8
作者 罗哲贤 《Acta meteorologica Sinica》 SCIE 1994年第1期60-71,共12页
The computational formulae are given for single-contour constant-value vortex motion influenced by the Coriolis force in the framework of contour dynamics,by which four numerical computations are performed,the result ... The computational formulae are given for single-contour constant-value vortex motion influenced by the Coriolis force in the framework of contour dynamics,by which four numerical computations are performed,the result exhibiting their validity. 展开更多
关键词 VORTEX NONLINEARITY contour dynamics
在线阅读 下载PDF
CONTOUR DYNAMICS FOR THE MOTION OF MULTIPLE RING VORTICES Luo Zhexian Nanjing Institute of Meteorology,Nanjing 210044
9
作者 罗哲贤 《Acta meteorologica Sinica》 SCIE 1995年第1期69-77,共9页
This paper generalizes the contour dynamics for single ring vortices to that for multiple ring vortices,wherein sixsets of numerical computation are performed.The phenomenon of the counterclockwise loop of a moving vo... This paper generalizes the contour dynamics for single ring vortices to that for multiple ring vortices,wherein sixsets of numerical computation are performed.The phenomenon of the counterclockwise loop of a moving vortex is clearly shown in the computational results and the asymmetric change with time of the vortex structure may serve as a pre-cursor for the phenomenon.Besides,we also discuss the dependence of the motion direction of a vortex upon the degreeof its contour denseness,and the dependence of the westward component of vortex motion upon its asymmetricstructure.The results are fairly consistent with those of previous dynamical analyses and numerical experiments. 展开更多
关键词 contour dynamics multiple ring vortex Coriolis force NONLINEARITY
在线阅读 下载PDF
SIMULATION OF TYPHOON'SANOMALOUS TRACK(Ⅱ)──CD METHOD
10
作者 林缅 李家春 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 1999年第1期43-50,共8页
Contour dynamics (CD) method for the motions of typhoon is presented in this paper. The effect of asymmetric inner structure on the typhoon'sanomalous track has been discussed in different environmental steering. ... Contour dynamics (CD) method for the motions of typhoon is presented in this paper. The effect of asymmetric inner structure on the typhoon'sanomalous track has been discussed in different environmental steering. Todemonstrate the feasibility of the method, the track of Typhoon Yancy(9012) isconcerned with. The numerical results show that the method can describe the tendency of looping qualitatively. 展开更多
关键词 TYPHOON anomalous track contour dynamics (CD) method
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部