期刊文献+
共找到19,469篇文章
< 1 2 250 >
每页显示 20 50 100
Application of Dual-Source CT TurboFlash Coarse Pitch Scanning in Coronary Artery Imaging
1
作者 Shuiqing Zhuo Xiaoling Chen +3 位作者 Jingping Yu Haoqiang He Guixiao Xu Chuanmiao Xie 《Open Journal of Medical Imaging》 2018年第3期64-72,共9页
Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scannin... Objective: To compare and analyze the image quality and radiation dose of three scanning modes of dual-source CT coronary artery retrospectively, and to discuss the application value of TurboFlash coarse pitch scanning mode. Methods: The imaging data of 100 patients who underwent CT coronary angiography (CCTA) using Siemens force CT retrospective gated triggering spiral scan (RES-SPIRAL), adaptive prospective gated triggering sequence scan (SEQ) and prospective coarse pitch scan (TurboFlash) retrospectively was collected. The image quality was evaluated by objective and subjective methods. The effective radiation dose of patients was compared and analyzed, and the indications of the three scanning modes were analyzed. The application value of dual-source CT TurboFlash coarse pitch scanning in coronary artery imaging was evaluated. Results: The results showed that the left main coronary artery, the right coronary artery and their tertiary branches could be clearly displayed in the three groups of images: the left anterior descending branch, the left circumflex branch, and their three-level branches. There was no statistical difference in subjective image quality among the three groups of pictures (P > 0.05). There was no statistical difference in objective evaluation indexes, such as CT value, SNR, CNR and Noise among the three groups (P > 0.05). The patient radiation dose results showed that the effective radiation dose ED of RES-SPIRA scan was (9.22 ± 1.33) mSv. The dose of SEQ was (2.88 ± 2.47) mSv, and the dose of TurboFlash was (0.51 ± 0.16) mSv. There was significant difference in comparison of the three groups (P 0.05). RES-spiral scanning had the highest radiation dose and TurboFlash coarse pitch scanning (TurboFlash) had the lowest radiation dose. Conclusion: TurboFlash coarse pitch scanning is low in dosage, fast in speed and wide in adaptability. It is especially suitable for the elderly, children, coma and other patients who cannot cooperate with breath-holding examination, as well as for the screening and examination of coronary artery diseases in asymptomatic population. Undoubtedly, it is a worthy method of heart coronary artery examination. 展开更多
关键词 dual-source CT CORONARY COMPUTED Tomographic ANGIOGRAPHY Coarse PITCH SPIRAL SCANNING Image Quality Radiation Dose
暂未订购
双源CT Flash扫描联合70 kV在儿童肺炎复查的可行性研究
2
作者 张涛 曹永佩 李正正 《中国医学计算机成像杂志》 北大核心 2025年第5期732-737,共6页
目的:探讨双源CT Flash扫描联合70 kV在儿童肺炎复查中的可行性。方法:前瞻性收集2024年1—7月因肺炎就诊我院,并完成前后两次CT扫描的30例患者,其中男14例,女16例,平均年龄(7.3±3.5)岁(5个月~11.5岁),体重指数(BMI)为(15.45±... 目的:探讨双源CT Flash扫描联合70 kV在儿童肺炎复查中的可行性。方法:前瞻性收集2024年1—7月因肺炎就诊我院,并完成前后两次CT扫描的30例患者,其中男14例,女16例,平均年龄(7.3±3.5)岁(5个月~11.5岁),体重指数(BMI)为(15.45±2.62)kg/m^(2)。根据研究方案,均采用Flash模式扫描,首次检查使用80 kV管电压,复查使用70 kV管电压,其余参数相同。比较前后两次CT扫描图像质量、辐射剂量。结果:与首次检查相比,复查的辐射剂量指标CT剂量指数(CTDIvol)、剂量长度乘积(DLP)和全身有效剂量(ED)分别降低了40.38%[(0.31±0.11)mGy vs(0.52±0.20)mGy]、40.74%[(8.67±3.76)mGy·cm vs(14.63±7.18)mGy·cm]和40.91%[(0.13±0.05)mSv vs(0.22±0.10)mSv],差异有统计学意义(均P<0.001);与首次检查图像质量相比,复查图像的背景噪声值增高,信噪比(SNR)值、对比度噪声比(CNR)值分别下降21.14%、13.42%,差异具有统计学意义(均P<0.05);2名医师对两组图像的主观评分一致性高(Kappa=0.72~0.879),两组图像的肺窗和纵隔窗图像质量评分均存在差异(P<0.001),以肺窗图像为判断标准,首次检查图像质量中位评分为5分(4分,5分),复查图像质量的中位评分为4分(3分,5分),所有图像质量均满足诊断需求。结论:70 kV联合双源CT Flash扫描在儿童肺炎复查中具有很好的可行性,图像质量可以满足临床诊断和评价治疗效果需求,且辐射剂量显著降低,值得临床推广使用。 展开更多
关键词 低管电压 双源CT flash模式 低辐射剂量 儿童肺炎
暂未订购
DSP片上Flash测试系统设计与实现
3
作者 王涛 于鹏 钱昀莹 《电子技术应用》 2025年第2期41-45,共5页
在DSP芯片的可靠性筛选考核试验中,片上Flash擦写耐久和数据保持测试是最重要的试验之一。针对内建自测试和外部自动化机台测试的局限性,提出了一种DSP片上Flash测试系统的设计与实现方法。在分析了Flash故障类型和测试算法的基础上,给... 在DSP芯片的可靠性筛选考核试验中,片上Flash擦写耐久和数据保持测试是最重要的试验之一。针对内建自测试和外部自动化机台测试的局限性,提出了一种DSP片上Flash测试系统的设计与实现方法。在分析了Flash故障类型和测试算法的基础上,给出了硬件原理图和软件实现流程,并搭建了实物平台进行效果评估。测试结果表明:该系统可实现多工位DSP片上Flash自动化测试,无需人工参与。同时工作状态可实时显示,测试过程中的数据和结果自动保存在外部存储器中,便于后期进行测试结果统计分析。 展开更多
关键词 片上flash 擦写耐久 数据保持 测试系统
在线阅读 下载PDF
基于Flash ActionScript语言的凸轮机构运动规律研究
4
作者 刘先梅 张明存 《白城师范学院学报》 2025年第2期51-57,共7页
基于Flash ActionScript语言开发了一套参数驱动的平面凸轮机构运动仿真系统,通过设计不同的虚拟实验让使用者了解平面凸轮机构的组成、工作原理、特点及其运动形式.该系统可实现用户注册、密码登陆、凸轮从动件运动规律的实验设计等不... 基于Flash ActionScript语言开发了一套参数驱动的平面凸轮机构运动仿真系统,通过设计不同的虚拟实验让使用者了解平面凸轮机构的组成、工作原理、特点及其运动形式.该系统可实现用户注册、密码登陆、凸轮从动件运动规律的实验设计等不同功能,通过参数化输入时的运动分析与仿真,自动生成凸轮轮廓及不同运动规律下的升程、速度、位移三个线图.研究结果表明,基于Flash ActionScript的凸轮机构运动规律的系统设计,实现了凸轮从动件运动规律的分析. 展开更多
关键词 flash ActionScript语言 平面凸轮机构 运动分析与仿真 参数化
在线阅读 下载PDF
T-Flash学习软件研发及其在病理学实验课中的U-应用效果研究
5
作者 罗康华 刘昕 +2 位作者 吴亚东 刘嘉琪 蒋催蓉 《黔南民族医专学报》 2025年第2期230-233,共4页
目的:本研究旨在解决基础医学病理学实验课学习效果不佳的问题,通过研发手机端T-Flash学习软件,结合智能手机的自主、交互、便携、实时等特性,创新实验课学习方式,以激发学生的学习兴趣,提高学习效果。方法:本研究以Tips(知识小贴士)、T... 目的:本研究旨在解决基础医学病理学实验课学习效果不佳的问题,通过研发手机端T-Flash学习软件,结合智能手机的自主、交互、便携、实时等特性,创新实验课学习方式,以激发学生的学习兴趣,提高学习效果。方法:本研究以Tips(知识小贴士)、Training(训练)和Test(考核)(简称3T)为设计理念,采用消消乐Flash游戏为载体,建立病理标本图片、知识Tips等素材库;在Unity平台制作试用版软件,选取典型病理器官标本和组织切片标本图片制作游戏图标,在游戏载入、返场及点击图标时设计知识Tips闪现滚动;设置闯关关卡、竞技场及积分榜,对在线学习及互动情况进行实时监控和测评;开发基于AI技术的实验小助手,通过病理实验课考试和问卷调查进行软件应用效果评价。结果:设计并开发了T-Flash学习软件v1.0版申请软件著作权获授权。实验组的标本考试成绩与理论考试成绩较对照组显著提高(P<0.05)。T-Flash v1.0版能有效辅助学习,激发学习兴趣,提高学习成绩。50名学生的问卷调查反馈积极,软件受到学生的欢迎。结论:T-Flash消消乐学习软件在基础医学病理学实验课中的创新应用取得了显著成效,证明了其作为新型学习工具的可行性和有效性。该软件不仅能提升学生的学习效果和兴趣,还具有推广到其他学科领域的潜力。本研究为医学教育领域的学习模式创新提供了有益的探索和借鉴。 展开更多
关键词 T-flash学习软件 病理学 实验课 创新教学 flash游戏
在线阅读 下载PDF
Non-enhanced Low-tube-voltage High-pitch Dual-source Computed Tomography with Sinogram Affirmed Iterative Reconstruction Algorithm of the Abdomen and Pelvis 被引量:3
6
作者 Hao Sun Hua-dan Xue +5 位作者 Zheng-yu Jin Xuan Wang Yu Chen Yong-lan He Da-ming Zhang Liang Zhu 《Chinese Medical Sciences Journal》 CAS CSCD 2014年第4期214-220,共7页
Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-... Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-enhanced abdominal and pelvic scans. Methods This institutional review board-approved prospective study included 64 patients who gave written informed consent for additional abdominal and pelvic scan with DSCT in the period from November to December 2012. The patients underwent standard non-enhanced CT scans(protocol 1) [tube voltage of 120 k Vp/pitch of 0.9/filtered back-projection(FBP) reconstruction] followed by high-pitch non-enhanced CT scans(protocol 2)(100 k Vp/3.0/SAFIRE). The total scan time, mean CT number, signal-to-noise ratio(SNR), image quality, lesion detectability and radiation dose were compared between the two protocols. Results The total scan time of protocol 2 was significantly shorter than that of protocol 1(1.4±0.1 seconds vs. 7.6±0.6 seconds, P<0.001). There was no significant difference between protocol 1 and protocol 2 in mean CT number of all organs(liver, 55.4±6.3 HU vs. 56.1±6.8 HU, P=0.214; pancreas, 43.6±5.9 HU vs. 43.7±5.8 HU, P=0.785; spleen, 47.9±3.9 HU vs. 49.4±4.3 HU, P=0.128; kidney, 32.2±2.3 HU vs. 33.1±2.3 HU, P=0.367; abdominal aorta, 44.8±5.6 HU vs. 45.0±5.5 HU, P=0.499; psoas muscle, 50.7±4.1 HU vs. 50.3±4.5 HU, P=0.279). SNR on images of protocol 2 was higher than that of protocol 1(liver, 5.0±1.2 vs. 4.5±1.1, P<0.001; pancreas, 4.0±1.0 vs. 3.6±0.8, P<0.001; spleen, 4.7±1.0 vs. 4.1±0.9, P<0.001; kidney, 3.1±0.6 vs. 2.8±0.6, P<0.001; abdominal aorta, 4.1±1.0 vs. 3.8±1.0, P<0.001; psoas muscle, 4.5±1.1 vs. 4.3±1.2, P=0.012). The overall image noise of protocol 2 was lower than that of protocol1(9.8±3.1 HU vs. 11.1±3.0 HU, P<0.001). Image quality of protocol 2 was good but lower than that of protocol 1(4.1±0.7 vs. 4.6±0.5, P<0.001). Protocol 2 perceived 229 of 234 lesions(97.9%) that were detected in protocol 1 in the abdomen and pelvis. Radiation dose of protocol 2 was lower than that of protocol 1(4.4±0.4 m Sv vs. 7.3±2.4 m Sv, P<0.001) and the mean dose reduction was 41.4%. Conclusion The high-pitch DSCT with SAFIRE can shorten scan time and reduce radiation dose while preserving image quality in non-enhanced abdominal and pelvic scans. 展开更多
关键词 high PITCH dual-source COMPUTED tomography iterative reconstruction imagequality radiation DOSE
暂未订购
Feasibility and Diagnostic Accuracy for Assessment of Coronary Artery Stenosis of Prospectively Electrocardiogram-gated High-pitch Spiral Acquisition Mode Dual-source CT Coronary Angiography in Patients with Relatively Higher Heart Rates: in Comparison wit 被引量:4
7
作者 Kai Sun Rui-juan Han +5 位作者 Li-fang Cui Rui-ping Zhao Li-jun Ma Li-jun Wang Li-gang Li Chang-yong Li 《Chinese Medical Sciences Journal》 CAS CSCD 2012年第4期213-219,共7页
Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography corona... Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch spiral acquisition mode with image acquired timing set at 20%-30% of the R-R interval provides a high diagnostic accuracy for the assessment of coronary stenoses combined with a 1.5% of non-diagnostic coronary segments and a radiation dose below 1 mSv. 展开更多
关键词 dual-source computed tomography coronary angiography high pitch prospectively electrocardiogram-triggered spiral mode high heart rate diagnostic accuracy
暂未订购
Intravenous Contrast Material Administration at High-pitch Dual-source CT Coronary Angiography: Bolus-tracking Technique with Shortened Time of Respiratory Instruction Versus Test Bolus Technique 被引量:2
8
作者 Kai Sun Guo-rong Liu +5 位作者 Yue-chun Li Rui-juan Han Li-fang Cui Li-jun Ma Li-gang Li Chang-yong Li 《Chinese Medical Sciences Journal》 CAS CSCD 2012年第4期225-231,共7页
Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acqu... Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acquisition mode (Flash mode) coronary computed tomography angiography (CCTA) compared with test bolus technique. Methods One hundred and eighty-four consecutive patients with mean heart rate ≤65 beats per minute undergoing CCTA were prospectively included in this study. The patients were randomly divided into two groups. Patients in the group A (n=92) instructed to shorten respiratory time received CCTA using bolus-tracking technique with high-pitch spiral acquisition mode (Flash mode), while those in the group B (n=92) underwent CCTA with test bolus technique. The attenuation in the ascending aorta, image noise, contrast-to-noise ratio and radiation doses of the two groups were assessed. Results There were no significant differences in the mean attenuation values in the ascending aorta (483.18±59.07 HU vs. 498.7±83.51 HU, P=0.183), image noise (21.4±4.5 HU vs. 20.9±4.3 HU, P=0.414), contrast-to-noise ratio (12.1±4.2 vs. 13.8±5.1, P=0.31) between the groups A and B. There were no significant differences in the radiation dose of dynamic monitoring scans (0.056±0.026 mSv vs. 0.062±0.018 mSv, P=0.068) and radiation dose of angiography (0.94±0.07 mSv vs. 0.96±0.15 mSv,P=0.926) between the two groups, while 15 mL less contrast material volume was administered in the group A than the group B. Conclusion Bolus-tracking technique with shortened time of respiratory in Flash mode of dual-source CT yields the similar homogeneous enhancement with less contrast material in comparison to the test bolus technique. 展开更多
关键词 dual-source computed tomography coronary angiography contrastenhancement test bolus technique bolus-tracking technique
暂未订购
Truncus arteriosus:Diagnosis with dual-source computed tomography angiography and low radiation dose 被引量:2
9
作者 Mustafa Koplay Derya Cimen +4 位作者 Mesut Sivri Osman Güvenc Derya Arslan Alaaddin Nayman Bulent Oran 《World Journal of Radiology》 CAS 2014年第11期886-889,共4页
Truncus arteriosus is an uncommon congenital cardiac abnormality which is characterized by a single arterial trunk origin from the heart that supplies both the systemic,pulmonary and coronary circulation.We present a ... Truncus arteriosus is an uncommon congenital cardiac abnormality which is characterized by a single arterial trunk origin from the heart that supplies both the systemic,pulmonary and coronary circulation.We present a preterm newborn female patient with type 2 truncusarteriosus,left superior vena cava and aberrant subclavian artery diagnosed with low dose dual-source cardiac computed tomography(CT).We discuss that low dose dual-source cardiac CT has more advantages than other imaging methods and it is an important modality for assessment of patients with conotruncal anomalies such as truncusarteriosus. 展开更多
关键词 Truncusarteriosus Type 2 dual-source computed tomography ANGIOGRAPHY Radiation dose
暂未订购
Flash开关单元编程及擦除阈值电压回归模型
10
作者 翟培卓 洪根深 +3 位作者 王印权 郑若成 谢儒彬 张庆东 《半导体技术》 北大核心 2025年第2期154-160,共7页
Flash开关单元是实现Flash型现场可编程门阵列(FPGA)的重要配置单元,具有可重构、集成度高、功耗低的优势。采用正交试验设计方法,进行了n型Flash开关单元编程及擦除试验,获取了Sense管和Switch管编程及擦除阈值电压,构建了Sense管编程... Flash开关单元是实现Flash型现场可编程门阵列(FPGA)的重要配置单元,具有可重构、集成度高、功耗低的优势。采用正交试验设计方法,进行了n型Flash开关单元编程及擦除试验,获取了Sense管和Switch管编程及擦除阈值电压,构建了Sense管编程阈值电压、Sense管擦除阈值电压、Switch管编程阈值电压、Switch管擦除阈值电压共四个回归模型。结果表明:所建立模型预测阈值电压的最大误差均不超过0.15 V,平均误差均不超过0.06 V,均具有较高的显著性,模型可信度高;Sense管和Switch管编程阈值电压与编程时间的对数、编程正压、编程负压分别呈线性关系,Sense管和Switch管擦除阈值电压与擦除时间的对数、擦除正压、擦除负压亦分别呈线性关系。回归模型可为Flash开关单元操作波形的设计和优化提供参考依据。 展开更多
关键词 正交试验 flash 开关单元 阈值电压 回归模型
原文传递
双源CT Turbo-Flash扫描模式CTA评价冠状动脉狭窄的价值分析
11
作者 雷力行 黄小华 +2 位作者 刘念 唐玲玲 马琳竣 《CT理论与应用研究(中英文)》 2025年第6期1128-1135,共8页
目的:分析双源CT Turbo-Flash扫描模式冠状动脉CT血管成像(CCTA)评价冠状动脉狭窄的价值。方法:选取2023年10月至2024年11月我院接受CCTA检查患者150例,依据所采用的扫描模式分为观察组(行双源CT Turbo-Flash扫描模式,n=75)、对照组(采... 目的:分析双源CT Turbo-Flash扫描模式冠状动脉CT血管成像(CCTA)评价冠状动脉狭窄的价值。方法:选取2023年10月至2024年11月我院接受CCTA检查患者150例,依据所采用的扫描模式分为观察组(行双源CT Turbo-Flash扫描模式,n=75)、对照组(采用回顾性心电门控扫描模式,n=75),分析两组扫描参数(CT-血流储备分数(CT-FFR)、管腔内CT强化密度值、Agatston钙化积分、钙化体积)、图像质量(CT值、信噪比(SNR))、辐射剂量(剂量长度乘积(DLP)、容积CT剂量指数(CTDIvol)、有效辐射剂量(ED))。结果:观察组CT-FFR、管腔内CT强化密度值、Agatston钙化积分高于对照组;双源CT Turbo-Flash扫描模式下,随冠状动脉狭窄程度增加,获得的CT-FFR、管腔内CT强化密度值、Agatston钙化积分增加;以数字减影血管造影(DSA)为金标准,观察组诊断冠状动脉中重度狭窄的敏感度、特异度、准确度分别为96.43%、87.23%和90.67%,与对照组差异均无统计学意义;两组CT值、SNR、图像质量比较差异无统计学意义;观察组DLP、CTDIvol、ED均低于对照组。结论:双源CT Turbo-Flash扫描模式下行CCTA检查,评估冠状动脉狭窄的准确性、图像质量较好,可通过定量参数对狭窄程度予以评估,同时其DLP、CTDIvol、ED均较少,值得在临床推广实践。 展开更多
关键词 双源CT Turbo-flash扫描模式 冠状动脉CT成像 冠状动脉狭窄 图像质量 有效辐射剂量
原文传递
应用于Flash型FPGA的正高压电荷泵 被引量:1
12
作者 江少祥 禹胜林 +1 位作者 马金龙 吴楚彬 《电子科技》 2025年第3期75-81,共7页
Flash型FPGA(Filed Programmable Gate Array)在进行编程操作时,电荷泵为编程管栅端提供正高压。为满足Flash型FPGA的上电及时运行性和编程稳定性,要求电荷泵不仅能输出高压,还应具有较快的启动速度和较小的输出电压纹波。文中基于传统... Flash型FPGA(Filed Programmable Gate Array)在进行编程操作时,电荷泵为编程管栅端提供正高压。为满足Flash型FPGA的上电及时运行性和编程稳定性,要求电荷泵不仅能输出高压,还应具有较快的启动速度和较小的输出电压纹波。文中基于传统交叉耦合电荷泵提出一种正高压电荷泵。电荷泵的主体采取并联双支路结构,降低了输出电压纹波,采用六相不交叠时钟和新增时钟升压模块对电荷泵进行时序控制,在消除了反向电流影响的同时提高了电荷泵启动速度。在输出端设置稳压模块进行稳压调节,保证编程稳定性。仿真结果表明,在电源电压为3.3 V、时钟频率为20 MHz、负载电容为50 pF的条件下,电荷泵启动时间为6.6μs,输出电压稳定到15 V,输出纹波仅有23 mV。采用0.18μm CMOS(Complementary Metal Oxide Semiconductor)工艺流片后,测试结果满足Flash型FPGA的编程需求。 展开更多
关键词 flash型FPGA 编程 高压 交叉耦合 并联双支路 六相不交叠时钟 纹波 电荷泵
在线阅读 下载PDF
大规模Flash型FPGA整体功能仿真验证方法研究
13
作者 蔺旭辉 马金龙 +3 位作者 曹杨 熊永生 曹靓 赵桂林 《电子与封装》 2025年第1期71-76,共6页
提出了一种大规模Flash型FPGA整体电路编程后功能仿真验证的方法。通过对核心Flash单元建立数字Verilog等效模型,采用整体数字仿真验证和模拟仿真验证的方法,结合编程功能案例,对器件内部所有的资源模块进行功能仿真验证,并且提出了加... 提出了一种大规模Flash型FPGA整体电路编程后功能仿真验证的方法。通过对核心Flash单元建立数字Verilog等效模型,采用整体数字仿真验证和模拟仿真验证的方法,结合编程功能案例,对器件内部所有的资源模块进行功能仿真验证,并且提出了加快整体电路数字仿真速度的方法。将提出的仿真验证方法成功应用于大规模Flash型FPGA芯片设计验证,得到了正确的验证结果,整体电路仿真验证速度得到了显著提升。 展开更多
关键词 flash FPGA VERILOG 验证
在线阅读 下载PDF
Assessment of Intracardiac and Extracardiac Deformities in Patients with Various Types of Pulmonary Atresia by Dual-Source Computed Tomography
14
作者 Wenlei Qian Xinzhu Zhou +4 位作者 Ke Shi Li Jiang Xi Liu Liting Shen Zhigang Yang 《Congenital Heart Disease》 SCIE 2023年第1期113-125,共13页
Background:Pulmonary atresia(PA)is a group of heterogeneous complex congenital heart disease.Only one study modality might not get a correct diagnosis.This study aims to investigate the diagnostic power of dualsource ... Background:Pulmonary atresia(PA)is a group of heterogeneous complex congenital heart disease.Only one study modality might not get a correct diagnosis.This study aims to investigate the diagnostic power of dualsource computed tomography(DSCT)for all intracardiac and extracardiac deformities in patients with PA compared with transthoracic echocardiography(TTE).Materials and Methods:This retrospective study enrolled 79 patients and divided them into three groups according to their main diagnosis.All associated malformations and clinical information,including treatments,were recorded and compared among the three groups.The diagnostic power of DSCT and TTE on all associated malformations were compared.The surgical index(McGoon ratio,pulmonary arterials index(PAI),and total neopulmonary arterial index)and radiation dose were calculated on the basis of DSCT.Results:Of the patients,32,30,and 17 were divided into the groups of PA with ventricular septal defect(VSD),PA with VSD and major aortopulmonary collateral arteries,and PA with other major malformations,respectively.Consequently,182,162,and 13 intracardiac,extracardiac,and other major malformations were diagnosed,respectively.Moreover,DSCT showed a better diagnostic performance in extracardiac deformities(154 vs.117,p<0.001),whereas TTE could diagnose intracardiac deformities better(159 vs.139,p=0.001).The McGoon ratio,PAI,and treatment methods were significantly different among the three groups(p=0.014,p=0.008,and p=0.018,respectively).Conclusion:More than one imaging modality should be used to make a correct diagnosis when clinically suspecting PA.DSCT is superior to TTE in diagnosing extracardiac deformities and could be used to roughly calculate surgical indices to optimize treatment strategy. 展开更多
关键词 Pulmonary atresia complex congenital heart diseases dual-source computed tomography transthoracic echocardiography
暂未订购
Exploration the Method of Low Dose Coronary Artery Imaging with Dual-Source CT
15
作者 Zhiwei Huang Bo Xiao Lisha Zhong 《Journal of Biosciences and Medicines》 2013年第1期6-10,共5页
Objective: On the premise that the image quality meets the requirements of clinical diagnosis, we explored the methods to reduce the radiation dose of coronary artery imaging with Dual-Source CT (DSCT). Methods: We ra... Objective: On the premise that the image quality meets the requirements of clinical diagnosis, we explored the methods to reduce the radiation dose of coronary artery imaging with Dual-Source CT (DSCT). Methods: We randomly selected 200 patients with coronary heat disease (BIM 0.05). The average image noise in group A is (41.76 ± 7.98) HU, in group B the average image noise is (43.97 ± 3.88) HU, the dif- ference between the two groups was not statistically significant (P>0.05). The average CTDIvol of group A and B were (20.63 ± 2.24) mGy, (38.11 ± 10.69) mGy, respectively, then P <0.01. The average DLP of group A and B are (235.75 ± 28.64) mGycm and (492.59 ± 125.49) mGycm respectively, then P <0.01, the dif- ference of radiation dose had statistical significance (P<0.05). Conclusions: For coronary artery imaging with DSCT the heart electric pulse (AUTO) regulation technology can meet the diagnostic requirements and effectively reduce the radiation dose. 展开更多
关键词 dual-source CT(DSCT) CORONARY CT ANGIOGRAPHY Low DOSE Noise
暂未订购
3D NAND FLASH存储器辐射效应研究进展及展望
16
作者 向爽 张国和 +2 位作者 李洋 白豪杰 贺朝会 《微电子学与计算机》 2025年第10期85-100,共16页
相较于传统平面FLASH架构,引入垂直结构的3D NAND FLASH存储器显著提升了存储密度,有效缓解了工艺尺寸持续微缩的物理限制,在航天电子领域展现出广阔应用前景。然而,三维结构也带来了新的空间可靠性问题,使得三维堆叠器件表现出区别于... 相较于传统平面FLASH架构,引入垂直结构的3D NAND FLASH存储器显著提升了存储密度,有效缓解了工艺尺寸持续微缩的物理限制,在航天电子领域展现出广阔应用前景。然而,三维结构也带来了新的空间可靠性问题,使得三维堆叠器件表现出区别于平面器件的辐射响应机制。综述了3D NAND FLASH存储器辐射效应的研究现状,介绍了空间辐射环境下3D NAND FLASH的总剂量效应与单粒子效应(重离子、质子、中子)的研究进展,分析了涉及的辐射损伤机理和性能退化规律。结果表明,三维结构设计在一定程度上提高了器件的抗总剂量效应和单粒子效应能力。重点探讨了三维结构特有的辐射响应现象,包括总剂量辐射响应在垂直堆叠层结构中的“U”型非均匀变化、重离子效应中阈值电压的双次级峰分布等。最后,基于3D NAND FLASH的发展趋势,对先进NAND FLASH(尤其是面向超高堆叠层数和三维封装微模组方向发展的器件)辐射效应未来的研究方向和抗辐射加固思路进行了展望。 展开更多
关键词 3D NAND flash存储器 总剂量效应 单粒子效应 损伤机理
在线阅读 下载PDF
基于NAND Flash的ECC校验
17
作者 朱振麟 焦新泉 《电子器件》 2025年第5期1008-1012,共5页
针对NAND Flash在数据存储过程中出现的小几率“位错误”,对数据存储的可靠性带来很大影响的问题,提出基于汉明码的ECC数据检测及纠正算法,可以检测2 bit错误且检测并纠正1 bit错误。选用三星生产的K9WAG08U1A,该芯片一页容量为2 kbyte... 针对NAND Flash在数据存储过程中出现的小几率“位错误”,对数据存储的可靠性带来很大影响的问题,提出基于汉明码的ECC数据检测及纠正算法,可以检测2 bit错误且检测并纠正1 bit错误。选用三星生产的K9WAG08U1A,该芯片一页容量为2 kbyte,以一页为单位生成ECC校验码,增强可行性的同时可以实现1 bit/2 kbyte的纠错及2 bit/2 kbyte的检错能力。针对传统校验码生成速度慢,影响数据传输速率,提出校验码的预生成机制。测试结果表明,该算法可行性强,提高了数据传输的速率及可靠性。 展开更多
关键词 NAND flash 小几率 ECC校验码 可靠性
在线阅读 下载PDF
Value of Brand A Dual-source CT Scanning in the Differential Diagnosis of Lung Cancer
18
作者 HUANGYinyin ZHUYuli WUYi 《外文科技期刊数据库(文摘版)医药卫生》 2022年第10期216-219,共4页
Objective: to analyze the value of brand A dual-source CT scan in the differential diagnosis of lung cancer. Methods: 40 suspected cases of lung cancer admitted to our hospital from July 2021 to January 2022 were all ... Objective: to analyze the value of brand A dual-source CT scan in the differential diagnosis of lung cancer. Methods: 40 suspected cases of lung cancer admitted to our hospital from July 2021 to January 2022 were all examined by brand A dual-source CT scan. At the same time, the results of surgical pathological biopsy were analyzed to evaluate the value of the former in the differential diagnosis of lung cancer. Results: the 40 cases of suspected lung cancer were confirmed by surgical biopsy, and the remaining 10 cases were benign lesions, including 25 of 30 were adenocarcinoma and 5 squamous carcinoma. The diagnosis of the cases in this group of bisource CT suggested that 28 patients had lung cancer, and the remaining 12 patients were benign lesions, of which 25 patients had confirmed adenocarcinoma and 5 patients had squamous carcinoma. Using surgical pathological biopsy results as the reference standard, dual-source CT was 90.00% specific, 96.67% sensitive and 95.00% accurate;Overlay arterial and standardized iodine venous phase were lower than benign patients (P < 0.05), including Overlay venous, aortic iodine and benign patients (P> 0.05). Conclusion: the accuracy, specificity and sensitivity of brand A dual-source CT scan applied in the differential diagnosis of lung cancer are relatively high, among which Overlay arterial stage and standardized iodine concentration venous stage can be used as practical indicators of disease identification. 展开更多
关键词 lung cancer IDENTIFICATION dual-source CT benign lesions
暂未订购
一种非接触式FPGA配置Flash快速烧写方法
19
作者 王博 张瑜莹 +1 位作者 高鹏 李飞飞 《信息技术与信息化》 2025年第3期71-74,共4页
文章使用Xilinx公司Artix-7 XC7A100T FPGA与Micro公司28F00AP30T BPI配置Flash构成FPGA配置逻辑,并由2片ESP8266通讯芯片构建上位机与FPGA间的双向无线通信链路,共同组建Flash快速烧写实验平台。通过对Flash编程特性和无线通讯芯片工... 文章使用Xilinx公司Artix-7 XC7A100T FPGA与Micro公司28F00AP30T BPI配置Flash构成FPGA配置逻辑,并由2片ESP8266通讯芯片构建上位机与FPGA间的双向无线通信链路,共同组建Flash快速烧写实验平台。通过对Flash编程特性和无线通讯芯片工作方式的研究,编写基于FPGA的Flash快速烧写逻辑,设计了一种使用Wi-Fi传输的基于FPGA的非接触式配置Flash快速烧写方法,实现了非接触式更新FPGA配置Flash中的加载文件,为精简外部接口、提升产品气密性设计提供了一种可借鉴的思路。通过在Flash快速烧写实验平台中的验证,文章介绍的非接触式Flash快速烧写方法可以高效可靠的完成存储器件中FPGA配置文件的更新。 展开更多
关键词 FPGA 配置flash 非接触式 快速烧写
在线阅读 下载PDF
中国FLASH放射疗法快速发展的机遇和挑战
20
作者 罗辉 杨成梁 葛红 《中国肿瘤》 北大核心 2025年第4期326-330,共5页
近年来,FLASH放射疗法(FLASH radiotherapy,FLASH-RT)作为国际上一种尖端放疗技术,理论研究和临床试验发展迅速。FLASH-RT能够在极短时间(通常≤500 ms)内实施超高剂量率(平均剂量率≥40 Gy/s,瞬时剂量率≥100 Gy/s)照射,在保持相同肿... 近年来,FLASH放射疗法(FLASH radiotherapy,FLASH-RT)作为国际上一种尖端放疗技术,理论研究和临床试验发展迅速。FLASH-RT能够在极短时间(通常≤500 ms)内实施超高剂量率(平均剂量率≥40 Gy/s,瞬时剂量率≥100 Gy/s)照射,在保持相同肿瘤控制率的前提下,正常组织损伤小于同剂量的常规剂量率照射,即FLASH效应。FLASH-RT具有独特的放射生物学优势,是目前国际放射肿瘤学界的前沿领域。中国在FLASH-RT的研发和临床试验方面取得了飞跃式的进展,成为重要的参与者。全文对中国FLASH-RT面临的新挑战和机遇进行了全面的阐述。 展开更多
关键词 flash放疗 临床研究 机遇 挑战 中国
原文传递
上一页 1 2 250 下一页 到第
使用帮助 返回顶部