期刊文献+
共找到93篇文章
< 1 2 5 >
每页显示 20 50 100
Doubly-Fed Pumped Storage Units Participation in Frequency Regulation Control Strategy for New Energy Power Systems Based on Model Predictive Control 被引量:2
1
作者 Yuanxiang Luo Linshu Cai Nan Zhang 《Energy Engineering》 2025年第2期765-783,共19页
Large-scale new energy grid connection leads to the weakening of the system frequency regulation capability,and the system frequency stability is facing unprecedented challenges.In order to solve rapid frequency fluct... Large-scale new energy grid connection leads to the weakening of the system frequency regulation capability,and the system frequency stability is facing unprecedented challenges.In order to solve rapid frequency fluctuation caused by new energy units,this paper proposes a new energy power system frequency regulation strategy with multiple units including the doubly-fed pumped storage unit(DFPSU).Firstly,based on the model predictive control(MPC)theory,the state space equations are established by considering the operating characteristics of the units and the dynamic behavior of the system;secondly,the proportional-differential control link is introduced to minimize the frequency deviation to further optimize the frequency modulation(FM)output of the DFPSU and inhibit the rapid fluctuation of the frequency;lastly,it is verified on theMatlab/Simulink simulation platform,and the results show that the model predictive control with proportional-differential control link can further release the FM potential of the DFPSU,increase the depth of its FM,effectively reduce the frequency deviation of the system and its rate of change,realize the optimization of the active output of the DFPSU and that of other units,and improve the frequency response capability of the system. 展开更多
关键词 doubly-fed pumped storage unit model predictive control proportional-differential control link frequency regulation
在线阅读 下载PDF
A Low Common-Mode Voltage Virtual Space Vector Modulation of Three-Level Converters for Doubly-Fed Variable-Speed Pumped Storage Systems
2
作者 Ziqiang Man Lei Zhao +6 位作者 Zheng Tao Shiming Cheng Wei Yan Gaoyue Zhong Yu Lu Wenming Zhang Li Zhang 《Energy Engineering》 2025年第9期3555-3572,共18页
With the rapid integration of renewable energy sources,modern power systems are increasingly challenged by heightened volatility and uncertainty.Doubly-fed variable-speed pumped storage units(DFVS-PSUs)have emerged as... With the rapid integration of renewable energy sources,modern power systems are increasingly challenged by heightened volatility and uncertainty.Doubly-fed variable-speed pumped storage units(DFVS-PSUs)have emerged as promising technologies for mitigating grid oscillations and enhancing system flexibility.However,the excitation converters in DFVS-PSUs are prone to significant issues such as elevated common-mode voltage(CMV)and neutral-point voltage(NPV)fluctuations,which can lead to electromagnetic interference and degrade transient performance.To address these challenges,an optimized virtual space vector pulse width modulation(OVSVPWM)strategy is proposed,aiming to suppress CMV and NPV simultaneously through coordinated multi-objective control.Specifically,a dynamic feedback mechanism is introduced to adjust the balancing factor of basic vectors in the synthesized virtual small vector in real-time,achieving autonomous balancing of the NPV.To address the excessive switching actions introduced by the OVSVPWM strategy,a phase duty ratio-based sequence reconstruction method is adopted,which reduces the total number of switching actions to half of the original.A zero-level buffering scheme is employed to reconstruct the single-phase voltage-level output sequence,achieving peak CMV suppression down to udc/6.Simulation results demonstrate that the proposed strategy significantly improves electromagnetic compatibility and operational stability while maintaining high power quality. 展开更多
关键词 doubly-fed variable-speed pumped storage units three-level excitation converter common-mode voltage neutral-point voltage virtual space voltage vector
在线阅读 下载PDF
Modeling and small-signal stability analysis of doubly-fed induction generator integrated system 被引量:4
3
作者 Tianming Gu Puyu Wang +3 位作者 Dingyuan Liu Ao Sun Dejian Yang Gangui Yan 《Global Energy Interconnection》 EI CSCD 2023年第4期438-449,共12页
Owing to their stability,doubly-fed induction generator(DFIG)integrated systems have gained considerable interest and are the most widely implemented type of wind turbines and due to the increasing escalation of the w... Owing to their stability,doubly-fed induction generator(DFIG)integrated systems have gained considerable interest and are the most widely implemented type of wind turbines and due to the increasing escalation of the wind generation penetration rate in power systems.In this study,we investigate a DFIG integrated system comprising four modules:(1)a wind turbine that considers the maximum power point tracking and pitch-angle control,(2)induction generator,(3)rotor/grid-side converter with the corresponding control strategy,and(4)AC power grid.The detailed small-signal modeling of the entire system is performed by linearizing the dynamic characteristic equation at the steady-state value.Furthermore,a dichotomy method is proposed based on the maximum eigenvalue real part function to obtain the critical value of the parameters.Root-locus analysis is employed to analyze the impact of changes in the phase-locked loop,short-circuit ratio,and blade inertia on the system stability.Lastly,the accuracy of the small-signal model and the real and imaginary parts of the calculated dominant poles in the theoretical analysis are verified using PSCAD/EMTDC. 展开更多
关键词 doubly-fed induction generator(DFIG) Maximum power point tracking DICHOTOMY Small-signal stability
在线阅读 下载PDF
Research on Control Strategy of Grid-connected Brushless Doubly-fed Wind Power System Based on Virtual Synchronous Generator Control 被引量:8
4
作者 Shuai Liang Shi Jin Long Shi 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第4期404-412,共9页
The brushless doubly-fed wind power system based on conventional power control strategies lacks ‘inertia’ and the ability to support grid,which leads to the decline of grid stability.Therefore,a control strategy of ... The brushless doubly-fed wind power system based on conventional power control strategies lacks ‘inertia’ and the ability to support grid,which leads to the decline of grid stability.Therefore,a control strategy of brushless doubly-fed reluctance generator(BDFRG) based on virtual synchronous generator(VSG) control is proposed to solve the problem in this paper.The output characteristics of BDFRG based on VSG are similar to a synchronous generator(SG),which can support the grid frequency and increase the system ‘inertia’.According to the mathematical model of BDFRG,the inner loop voltage source control of BDFRG is derived.In addition,the specific structure and parameter selection principle of outer loop VSG control are expounded.The voltage source control inner loop of BDFRG is combined with the VSG control outer loop to establish the overall architecture of BDFRG-VSG control strategy.Finally,the effectiveness and feasibility of the proposed strategy are verified in the simulation. 展开更多
关键词 Virtual synchronous generator Brushless doubly-fed relutance generator Grid support ability Voltage source control
在线阅读 下载PDF
Analytical Model and Topology Optimization of Doubly-fed Induction Generator 被引量:1
5
作者 Lu Sun Haoyu Kang +4 位作者 Jin Wang Zequan Li Jianjun Liu Yiming Ma Libing Zhou 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第2期162-169,共8页
As the core component of energy conversion for large wind turbines,the output performance of doubly-fed induction generators (DFIGs) plays a decisive role in the power quality of wind turbines.To realize the fast and ... As the core component of energy conversion for large wind turbines,the output performance of doubly-fed induction generators (DFIGs) plays a decisive role in the power quality of wind turbines.To realize the fast and accurate design optimization of DFIGs,this paper proposes a novel hybriddriven surrogate-assisted optimization method.It firstly establishes an accurate subdomain model of DFIGs to analytically predict performance indexes.Furthermore,taking the inexpensive analytical dataset produced by the subdomain model as the source domain and the expensive finite element analysis dataset as the target domain,a high-precision surrogate model is trained in a transfer learning way and used for the subsequent multi-objective optimization process.Based on this model,taking the total harmonic distortion of electromotive force,cogging torque,and iron loss as objectives,and the slot and inner/outer diameters as parameters for optimizing the topology,achieve a rapid and accurate electromagnetic design for DFIGs.Finally,experiments are carried out on a 3MW DFIG to validate the effectiveness of the proposed method. 展开更多
关键词 doubly-fed induction generators Accurate subdomain model Surrogate-assisted Transfer learning
在线阅读 下载PDF
Parameter Deviation Effect Study of the Power Generation Unit on a Doubly-Fed Induction Machine-based Shipboard Propulsion System 被引量:2
6
作者 Kai Ni Yihua Hu Chun Gan 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期339-348,共10页
To lower the difficulty of fault protection,a doubly-fed induction machine based shipboard propulsion system(DFIM-SPS)that is partially power decoupled is presented.In such an intrinsically safe SPS architecture,a syn... To lower the difficulty of fault protection,a doubly-fed induction machine based shipboard propulsion system(DFIM-SPS)that is partially power decoupled is presented.In such an intrinsically safe SPS architecture,a synchronous generator(SG)is employed for power generation,and the accuracy of the parameters of power generation unit(PGU)plays an important role in SPS stable operation.In this paper,the PGU parameter deviations are studied to evaluate the effects on system performance.The models of salient-pole SG,type DC1A excitation system(EXS)and DFIM are illustrated first.Besides,the corresponding control scheme is explained.For the 16 important parameters of PGU,up to 40%of parameter deviations are applied to implement parameter sensitivity analysis.Then,simulation studies are carried out to evaluate the parameter deviation effects on system performance in detail.By defining three parameter deviation effect indicators(PDEIs),the effects on the PGU output variables,which are the terminal voltage and output active power,are studied.Moreover,the increasing rates of PDEIs with different degrees of parameter deviations for the key parameters are analyzed.Furthermore,the overall system performance is investigated for the two most influential PGU parameters.This paper provides some vital clues on SG and EXS parameter identification for DFIM-SPS. 展开更多
关键词 shipboard propulsion system partially power decoupled doubly-fed induction machine synchronous generator parameter deviation
在线阅读 下载PDF
Robust Position Observer for Sensorless Direct Voltage Control of Stand-Alone Ship Shaft Brushless Doubly-Fed Induction Generators 被引量:4
7
作者 Mohamed G.Hussien Yi Liu Wei Xu 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第4期363-376,共14页
The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position obser... The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position observer using the space vector flux relations of BDFIG may achieve the desired voltage control of the power winding(PW)in terms of magnitude and frequency,without any speed/position sensors.The proposed algorithm does not require any additional observers for obtaining the generator speed.The proposed technique can directly achieve the desired DVC based on the estimated rotor position,which may reduce the overall system cost.The stability analysis of the proposed observer is investigated and confirmed with the concept of quadratic Lyapunov function and using the multi-model representation.In addition,the sensitivity analysis of the presented method is confirmed under different issues of parameter uncertainties.Comprehensive results from both simulation and experiments are realized with a prototype wound-rotor BDFIG,which demonstrate the capability and efficacy of the proposed sensorless DVC strategy with good transient behavior under different operating conditions.Furthermore,the analysis confirms the robustness of the proposed observer via the machine parameter changes. 展开更多
关键词 Brushless doubly-fed induction generator(BDFIG) direct voltage control(DVC) PW voltage-oriented vector control rotor position observer ship shaft applications.
在线阅读 下载PDF
A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support
8
作者 沈阳武 柯德平 +3 位作者 孙元章 Daniel Kirschen 王轶申 胡元朝 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第7期52-63,共12页
A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient volt... A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter(GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter(RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive(priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method. 展开更多
关键词 doubly-fed induction generator transient rotor current control superconducting magnetic energy storage voltage support
原文传递
Coordinated Rotor-Side Control Strategy for Doubly-FedWind Turbine under Symmetrical and Asymmetrical Grid Faults
9
作者 Quanchun Yan Chao Yuan +2 位作者 WenGu Yanan Liu Yiming Tang 《Energy Engineering》 EI 2023年第1期49-68,共20页
In order to solve the problems of rotor overvoltage,overcurrent and DC side voltage rise caused by grid voltage drops,a coordinated control strategy based on symmetrical and asymmetrical low voltage ride through of ro... In order to solve the problems of rotor overvoltage,overcurrent and DC side voltage rise caused by grid voltage drops,a coordinated control strategy based on symmetrical and asymmetrical low voltage ride through of rotor side converter of the doubly-fed generator is proposed.When the power grid voltage drops symmetrically,the generator approximate equation under steady-state conditions is no longer applicable.Considering the dynamic process of stator current excitation,according to the change of stator flux and the depth of voltage drop,the system can dynamically provide reactive power support for parallel nodes and suppress the rise of DC side voltage and rotor over-current.When the grid voltage drops asymmetrically,the positive and negative sequence components are separated in the rotating coordinate system.The doubly fed generator model is established to suppress the rotor positive sequence current and negative sequence current respectively.At the same time,the output voltage limit of the converter is discussed,and the reference value is adjusted within the allowable output voltage range.In order to adapt to the occurrence of different types of power grid faults and complex operating conditions,a fast switching module of fault type detection and rotor control mode is designed to detect the type of power grid faults and voltage drop depth in real time and switch the rotor side control mode dynamically.Finally,the simulation model of the doubly fed wind turbine is constructed in Matlab/Simulink.The simulation results verify that the proposed control strategy can improve the low-voltage ride through performance of the system when dealing with the symmetrical and asymmetric voltage drop of the power grid and identify the power grid fault type and provide the correct control strategy. 展开更多
关键词 doubly-fed wind turbines symmetrical faults asymmetrical faults low voltage ride through rotor side control fault type detection
在线阅读 下载PDF
Suppression of thrust fluctuation of doubly-fed linear motor
10
作者 Ying WANG Kunlun ZHANG Mi ZHOU 《Journal of Modern Transportation》 2012年第2期103-107,共5页
Because the mover and stator of a doubly-fed linear motor are both equipped with three-phase windings, the motor enables contactless energy to be transferred from the stator to the mover. Thus, when a doubly-fed linea... Because the mover and stator of a doubly-fed linear motor are both equipped with three-phase windings, the motor enables contactless energy to be transferred from the stator to the mover. Thus, when a doubly-fed linear motor is used in the linear driving system of trains, neither an overhead line nor a third rail is needed. However, the doubly- fed motor will lead to more severe thrust fluctuation than the unilateral motors. In order to overcome this shortcoming, the thrust fluctuation of the doubly-fed motor should be analyzed. In this paper, an expression for motor thrust is derived. It points out that the slot effect caused by the slotted structure is the main reason for the increase of thrust fluctuation. The method of adopting unequal pole pitch and unequal slot numbers per pole per phase of stator and mover, is proposed to weaken the slot effect when designing the motor slot parameters. Three different motor models are simulated by ANSOFT. The proposed method results in a motor thrust fluctuation coefficient of 8.4%, compared to 49.4% for the conventional method. Therefore, the motor's thrust fluctuation is effectively suppressed by the proposed method. 展开更多
关键词 doubly-fed linear motor thrust fluctuation slot effect fractional slot
在线阅读 下载PDF
Performance Analysis of Nested-loop Secondary Linear Doubly-fed Machine Considering End Effects
11
作者 Yaping Zhang Jian Ge +4 位作者 Wei Xu Weiye Li Yinglu Luo Shihu Su Yunfeng He 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第3期298-305,共8页
Nested-loop secondary linear doubly-fed machine(NLS-LDFM) is a novel linear machine evolved from rotary brushless doubly-fed induction machine, which has a good application prospect in linear metro. In order to analyz... Nested-loop secondary linear doubly-fed machine(NLS-LDFM) is a novel linear machine evolved from rotary brushless doubly-fed induction machine, which has a good application prospect in linear metro. In order to analyze the performance of NLS-LDFM, the mechanism and action rules of end effects are investigated in this paper. Firstly, the mechanism of static and dynamic end effects is analyzed in aspect of direct coupling, winding asymmetry and transient secondary current. Furthermore, based on the winding theory for short primary linear machines, the machine parameters are established qualitatively considering pulsating magnetic field of NLS-LDFM. Finally, the NLS-LDFM performance analysis is supplemented by the finite element algorithm(FEA) simulation and experiments under different operating conditions. 展开更多
关键词 Linear doubly-fed machine(LDFM) End effect Parameter analysis Finite element algorithm(FEA)
在线阅读 下载PDF
Brushless Doubly-Fed Induction Machine as a Variable Frequency Transformer
12
作者 Ayman Abdel-Khalik Ahmed Elserougi +1 位作者 Ahmed Massoud Shehab Ahmed 《Journal of Energy and Power Engineering》 2013年第1期110-117,共8页
VFT (variable frequency transformer) has been recently used as art alternative to HVDC (high voltage direct current) to control power flow between asynchronous networks. VFT consumes less reactive power than a bac... VFT (variable frequency transformer) has been recently used as art alternative to HVDC (high voltage direct current) to control power flow between asynchronous networks. VFT consumes less reactive power than a back-to-back HVDC system, provides faster initial transient recovery, and has better natural damping capability. VFT is simply a DFIM (doubly-fed induction machine) where the machine torque controls the power flow from stator to rotor and vice versa. The main disadvantage of this VFT is the slip rings and brushes required for the rotor circuit, especially in bulk power transmission. The BDFM (brushless doubly-fed machine) with nested cage rotor machine is proved to be a comparable alternative to conventional DFIM in many applications with the advantage that all windings being in the stator frame with fixed output terminals. In this paper, the BDFM is used as a BVFT (brushless variable frequency transformer). A prototype machine is designed and simulated to verify the system validity. 展开更多
关键词 Variable frequency transformer brushless doubly-fed machines AC machines induction machine.
在线阅读 下载PDF
Step-Loading Characteristics of Gas Engine Cogeneration System Using Doubly-Fed Induction Generator in Stand-Alone Operation
13
作者 Tetsuji Daido Yushi Miura +1 位作者 Toshifumi Ise Yuki Sato 《Journal of Energy and Power Engineering》 2014年第3期530-542,共13页
Application of a DFIG (doubly-fed induction generator), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supp... Application of a DFIG (doubly-fed induction generator), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supply is one of important roles for the gas engine eogeneration system. In the case of conventional constant speed of synchronous generator, the amount of the allowed step load is limited to around 30% of the rated power. On the other hand, DFIG is expected to increase the amount of step load during the stand-alone operation. In this paper, it has been demonstrated that an increase in the gas engine speed resulted in an increase in the maximum amount of step load using experimental equipment with a real gas engine. It has been concluded that the proposed system can improve the performance of an emergency power supply at step-loading. 展开更多
关键词 Step load change doubly-fed induction generator gas engine cogeneration system stand-alone operation.
在线阅读 下载PDF
Transient Stability Analysis and Coordinated Control Strategy of DC-link Voltage for PLL-based Grid-connected DFIG System During Asymmetrical Grid Faults
14
作者 Yi Luo Jun Yao +3 位作者 Dong Yang Hai Xie Linsheng Zhao Rongyu Jin 《Protection and Control of Modern Power Systems》 2026年第1期123-140,共18页
The transient behavior of DC-link voltage(DCV)significantly affects the low-voltage ride-through for phase-locked loop(PLL)-based grid-connected doubly-fed induction generator(DFIG)systems.This study investigates the ... The transient behavior of DC-link voltage(DCV)significantly affects the low-voltage ride-through for phase-locked loop(PLL)-based grid-connected doubly-fed induction generator(DFIG)systems.This study investigates the DCV transient behavior of a PLL-based DFIG system under asymmetrical grid faults.First,by considering the coupling characteristics of positive and negative sequence(PNS)components,a nonlinear largesignal model of DCV is developed.Furthermore,the transient characteristics of DCV under varying parameters are analyzed using phase trajectory diagrams.In addition,the transient stability(TS)mechanism of DCV during asymmetrical faults is examined through an en-ergy function approach.The analysis indicates that the transient instability of DCV is primarily associated with the control characteristics of PNS PLLs,while the TS level of DCV is mainly determined by the power coordination control between the rotor side converter and grid side converter.Moreover,a coordinated control strategy is proposed to enhance the TS of DCV under asymmet-rical grid faults.Finally,both simulation and experimental results are presented to validate the theoretical analysis and the effectiveness of the proposed strategy. 展开更多
关键词 Transient stability DC-link voltage doubly-fed induction generator asymmetrical grid faults stability control strategy
在线阅读 下载PDF
Transient Overcurrent Suppression and Fault Ride-through Strategy for Grid-forming DFIGs Based on Flux Linkage Tracking Control
15
作者 Meng Huang Sirui Shu +3 位作者 Yufei Hu Zhen Tian Xiaoming Zha Wenhe Wang 《CSEE Journal of Power and Energy Systems》 2026年第1期71-83,共13页
Virtor(VSG)technology is widely investigated and applied for dual synchronous generatoubly-fed induction generators(DFIGs)to provide virtual inertia.However,under grid faults,the conventional VSG-based DFIG faces chal... Virtor(VSG)technology is widely investigated and applied for dual synchronous generatoubly-fed induction generators(DFIGs)to provide virtual inertia.However,under grid faults,the conventional VSG-based DFIG faces challenges of transient overcurrent and instability.The critical limitation for grid-forming DFIGs to withstand serious grid faults is the rotor-side converter(RSC)’s inability to quickly generate proper rotor voltage to counteract transient electromotive force(EMF),which results in transient overcurrent and damage to the RSC.To fill this gap,this study introduces a novel low-voltage ride-through(LVRT)control strategy for the grid-forming DFIG under symmetrical grid fault conditions.To mitigate transient overcurrent,the core mechanism is to regulate the rotor flux linkage to align with the stator flux linkage in an optimal proportion.Under the proposed control strategy,both post-fault rotor current and required rotor voltage are constrained within operational limits.Moreover,fluctuations in electromagnetic torque are efficiently suppressed during grid disturbances.Consequently,the dynamic stability and power support capacity of the DFIG system remain intact throughout the transient process.Finally,simulation studies and experimental results are provided to verify the feasibility of the proposed approach. 展开更多
关键词 doubly-fed induction generator(DFIG) grid-forming converter low-voltage ride through(LVRT) transient current virtual synchronous generator(VSG)
原文传递
Converters’Loading Balance and Stability Verification for Doubly-fed Induction Generators
16
作者 Shenghu Li 《CSEE Journal of Power and Energy Systems》 2025年第3期1131-1140,共10页
Back-to-back converters are the main components of a doubly-fed induction generator(DFIG).If the loadings of the rotor-side converter(RSC)and the grid-side converter(GSC)are balanced,the capacity and the cost of the D... Back-to-back converters are the main components of a doubly-fed induction generator(DFIG).If the loadings of the rotor-side converter(RSC)and the grid-side converter(GSC)are balanced,the capacity and the cost of the DFIG will be reduced.This paper balances the converters'loadings by adjusting reactive power of the GSC(Q_(g*)).The steady-state constraints of the DFIG are solved to quantify the imbalance degree.A sensitivity model of the unbalanced loading with respect to Q_(g*)is proposed to balance the loadings.To verify if loading adjustment reduces the stability of the DFIG,the eigen–sensitivity models,with respect to Q_(g*)and stator voltage,are newly proposed with the power flow Jacobian matrix.Numerical results verify the accuracy and efficiency of the proposed model.The loadings of the converters are balanced with a few adjustments.Loading balance has little negative impact on the stability of the DFIG. 展开更多
关键词 CONVERTER doubly-fed induction generator eigen-sensitivity loading balance sensitivity STABILITY
原文传递
Enhancement of Frequency Regulation in AC-Excited Adjustable-Speed Pumped Storage Units during Pumping Operations
17
作者 Shuxin Tan Wei Yan +7 位作者 Lei Zhao Xianglin Zhang Ziqiang Man Yu Lu Teng Liu Gaoyue Zhong Weiqun Liu Linjun Shi 《Energy Engineering》 2025年第12期5175-5197,共23页
The integration of large-scale renewable energy introduces frequency instability challenges due to inherent intermittency.While doubly-fed pumped storage units(DFPSUs)offer frequency regulation potential in pumping mo... The integration of large-scale renewable energy introduces frequency instability challenges due to inherent intermittency.While doubly-fed pumped storage units(DFPSUs)offer frequency regulation potential in pumping mode,conventional strategies fail to address hydraulic-mechanical coupling dynamics and operational constraints,limiting their effectiveness.This paper presents an innovative primary frequency control strategy for double-fed pumped storage units(DFPSUs)operating in pumpingmode,integrating an adaptive parameter calculation method.This method is constrained by operational speed and power limits,addressing key performance factors.A dynamic model that incorporates the reversible pump-turbine characteristics is developed to translate frequency deviations into coordinated adjustments in speed and power during pumping operations.The research thoroughly analyzes the influence of control parameters on the frequency response dynamics.Additionally,the paper introduces a deep reinforcement learning(DRL)-based optimization framework,which enables real-time tuning of control parameters in response to changing rotor speed and frequency states.This method strategicallymanages the utilization of kinetic energy while ensuring compliance with operational safety constraints.The effectiveness of the proposed strategy is validated through simulation studies conducted on a four-machine,two-area DFPSU system.These studies demonstrate the strategy’s potential for improving frequency regulation performance under a variety of operating conditions,highlighting its effectiveness in optimizing energy storage and frequency control in power grids. 展开更多
关键词 doubly-fed pumped storage unit primary frequency control adaptive control variable coefficient deep reinforcement learning smart grid
在线阅读 下载PDF
并网型双馈风电机组动态稳定性仿真 被引量:27
18
作者 闫广新 晁勤 +1 位作者 刘新刚 周伟 《电网技术》 EI CSCD 北大核心 2007年第24期63-65,76,共4页
介绍了变速恒频双馈风电机组的基本结构,建立了双馈风电机组在d-q坐标系下的动态数学模型。应用Matlab/Simulink搭建了系统仿真模块,并对并网型双馈风电机组的动态稳定性做了仿真试验研究,结果表明:在风电系统中利用变速技术后可以提高... 介绍了变速恒频双馈风电机组的基本结构,建立了双馈风电机组在d-q坐标系下的动态数学模型。应用Matlab/Simulink搭建了系统仿真模块,并对并网型双馈风电机组的动态稳定性做了仿真试验研究,结果表明:在风电系统中利用变速技术后可以提高风能的利用率,改善电力系统稳定性;变速双馈风电机组具有低电压穿越功能。 展开更多
关键词 风力发电 变速双馈风电机 动态数学模型 低电 压穿越功能
在线阅读 下载PDF
集群双馈风电场的分次调压控制 被引量:29
19
作者 陈惠粉 张毅威 +2 位作者 闵勇 乔颖 鲁宗相 《电力系统自动化》 EI CSCD 北大核心 2013年第4期7-13,共7页
基于集群风电场间无功电压耦合较强、通信条件较差的特点,提出以双馈风电机组为主、电容器/静止无功补偿器(SVC)为辅,不过分依赖风电机组与风电场自动电压控制系统间通信的集群双馈风电场分次调压控制策略。事先根据电网运行状况计算得... 基于集群风电场间无功电压耦合较强、通信条件较差的特点,提出以双馈风电机组为主、电容器/静止无功补偿器(SVC)为辅,不过分依赖风电机组与风电场自动电压控制系统间通信的集群双馈风电场分次调压控制策略。事先根据电网运行状况计算得到不需实时更新的双馈风电机组的PQ曲线,同步补偿无功功率以应对有功出力的变化,并仅在电网运行状况发生大幅变化时更新PQ曲线;在调节效果不够理想或PQ曲线未更新时,再利用电容器/SVC进行二次调压。通过对中国北方某地区集群风电场的仿真分析,验证了所述控制策略可有效减少风电机组连锁脱网的发生机会,并且其控制效果不受风电机组与风电场自动电压控制系统间通信中断的影响。 展开更多
关键词 集群风电场 双馈感应发电机 电压控制 通信中断 风电机组 连锁脱网
在线阅读 下载PDF
基于九开关变换器的双馈风电系统运行原理与控制研究 被引量:14
20
作者 梁宗泽 陈宇 +3 位作者 邹旭东 黄延润 文刚 康勇 《中国电机工程学报》 EI CSCD 北大核心 2015年第5期1221-1228,共8页
典型的双馈风力发电系统通常采用背靠背双脉宽调制变流器,但该结构共需12个IGBT,所需开关器件多。为减小双馈风电变流器的体积,提高变流器的功率密度,提出利用新型九开关变换器代替背靠背变流器的方案。该方案节省了3个IGBT,通过合适的... 典型的双馈风力发电系统通常采用背靠背双脉宽调制变流器,但该结构共需12个IGBT,所需开关器件多。为减小双馈风电变流器的体积,提高变流器的功率密度,提出利用新型九开关变换器代替背靠背变流器的方案。该方案节省了3个IGBT,通过合适的调制控制策略仍能保证与原系统具有同样的控制性能。结合九开关变换器特有的正弦脉宽调制方式,分析九开关变换器在双馈风力发电系统中的应用特点,把九开关变换器等效为网侧等效变换器和机侧等效变换器,给出系统的控制策略,并通过Matlab/Simulink仿真及实验验证该新型拓扑方案的可行性及控制策略的正确性。理论分析与实验结果均表明,这种新型拓扑结构在双馈风力发电系统中具有较好的应用前景。 展开更多
关键词 九开关变换器 双馈风力发电系统 网侧等效变换器 机侧等效变换器 控制策略
原文传递
上一页 1 2 5 下一页 到第
使用帮助 返回顶部