The pivotal role microchannels play in the thermal management of electronic components has,in recent decades,prompted extensive research into methods for enhancing their heat transfer performance.Among these methods,s...The pivotal role microchannels play in the thermal management of electronic components has,in recent decades,prompted extensive research into methods for enhancing their heat transfer performance.Among these methods,surface wettability modification was found to be highly effective owing to its significant influence on boiling dynamics and heat transfer mechanisms.In this study,we modified surface wettability using a nanocomposite coating composed of graphene nano plate(GNPs)and multi-walled carbon nanotubes(MWCNT)and then examined how the modification affected the transfer of boiling heat in microchannels.The resultant heat transfer coefficients for hydrophilic and hydrophilic composite(GNPs+MWCNT)microchannels were,respectively,42.8%and 33.95%higher compared with that of the uncoated surface.These results verify that hydrophilic GNP-based coating significantly improves boiling heat transfer performance.It was observed that a minor increase in contact angle,θfrom 73.142°to 75.73°,resulted in a noticeable decrease in thermal performance.This is attributed to diminished liquid film stability,reduced nucleation site activity,and weakened capillary-driven liquid replenishment.These findings underscore the crucial role of optimized surface wettability in maintaining efficient microchannel boiling.At high mass flux,the GNPS microchannels exhibited maximum pressure drop values,with a pressure drop ratio as high as 36%compared to 29%for the GNPs+MWCNT composite samples.Nevertheless,when a composite hydrophilic–hydrophobic coating was deposited through electrodeposition,the enhancement in heat transfer was less significant.This was probably due to decreased surface uniformity,diminished liquid film stability,and the disruption of effective nucleation behavior,all associated with the slight increase in surface contact angle.The obtained results can be used as guidance for designing advanced cooling surfaces in high-performance microelectronic and energy systems,where precise control of surface characteristics is critical.展开更多
The design and manufacturing of microchannels are crucial aspects of modern micro/nanomanufacturing processes,offering a versatile platform for manipulating and driving micro/nanoparticles or cells.In this study,we pr...The design and manufacturing of microchannels are crucial aspects of modern micro/nanomanufacturing processes,offering a versatile platform for manipulating and driving micro/nanoparticles or cells.In this study,we propose a method for manufacturing microchannels using optically induced dielectrophoresis technology to induce the polymerization of polyethylene glycol diacrylate solution.To overcome limitations related to the light intensity energy and the size of intact microchannels,we design and manufacture microstructures of various shapes with a height of 4µm.Additionally,we simulate and analyze the movement of and forces acting on polystyrene(PS)microspheres at different spatial positions within the microchannels.Finally,we successfully demonstrate applications involving the transport of PS microspheres in custom-fabricated microchannels.This novel biocompatible microchannel manufacturing method is simple and non-biotoxic.It provides a new approach for simulating physiological environments in vitro and cultivating and manipulating cells.展开更多
Integrating Bayesian Optimization with Volume of Fluid (VOF) simulations, this work aims to optimize the operational conditions and geometric parameters of T-junction microchannels for target droplet sizes. Bayesian O...Integrating Bayesian Optimization with Volume of Fluid (VOF) simulations, this work aims to optimize the operational conditions and geometric parameters of T-junction microchannels for target droplet sizes. Bayesian Optimization utilizes Gaussian Process (GP) as its core model and employs an adaptive search strategy to efficiently explore and identify optimal combinations of operational parameters within a limited parameter space, thereby enabling rapid optimization of the required parameters to achieve the target droplet size. Traditional methods typically rely on manually selecting a series of operational parameters and conducting multiple simulations to gradually approach the target droplet size. This process is time-consuming and prone to getting trapped in local optima. In contrast, Bayesian Optimization adaptively adjusts its search strategy, significantly reducing computational costs and effectively exploring global optima, thus greatly improving optimization efficiency. Additionally, the study investigates the impact of rectangular rib structures within the T-junction microchannel on droplet generation, revealing how the channel geometry influences droplet formation and size. After determining the target droplet size, we further applied Bayesian Optimization to refine the rib geometry. The integration of Bayesian Optimization with computational fluid dynamics (CFD) offers a promising tool and provides new insights into the optimal design of microfluidic devices.展开更多
Two-dimensional double-layer honeycomb(DLHC)materials are known for their diverse physical properties,but superconductivity has been a notably absent characteristic in this structure.We address this gap by investigati...Two-dimensional double-layer honeycomb(DLHC)materials are known for their diverse physical properties,but superconductivity has been a notably absent characteristic in this structure.We address this gap by investigating M_(2)N_(2)(M=Nb,Ta)with DLHC structure using first-principles calculations.Our results show that M_(2)N_(2)are stable and metallic,exhibiting superconducting behavior.Specifically,Nb_(2)N_(2)and Ta_(2)N_(2)display superconducting transition temperatures of 6.8 K and 8.8 K,respectively.Their electron-phonon coupling is predominantly driven by the coupling between metal d-orbitals and low-frequency metal-dominated vibration modes.Interestingly,two compounds also exhibit non-trivial band topology.Thus,M_(2)N_(2)are promising platforms for studying the interplay between topology and superconductivity and fill the gap in superconductivity research for DLHC materials.展开更多
With the increasing miniaturization of systems and surging demand for power density,accurate prediction and control of two-phase flow pressure drop have become a core challenge restricting the performance of microchan...With the increasing miniaturization of systems and surging demand for power density,accurate prediction and control of two-phase flow pressure drop have become a core challenge restricting the performance of microchannel heat exchangers.Pressure drop,a critical hydraulic characteristic,serves as both a natural constraint for cooling systems and determines the power required to pump the working fluid through microchannels.This paper reviews the characteristics,prediction models,and optimization measures of two-phase flow pressure drop for low-boiling-point working fluids in microchannels.It systematically analyzes key influencing factors such as fluid physical properties,operating conditions,channel geometry,and flow patterns,and discusses the complex mechanisms of pressure drop under the coupling effect of multi-physical fields.Mainstream prediction models are reviewed:the homogeneous flow model simplifies calculations but shows large deviations at low quality;the separated flow model considers interphase interactions and can be applied to micro-scales after modification;the flow-pattern-based model performs zoned modeling but relies on subjective classification;machine learning improves prediction accuracy but faces the“black-box”problem.In terms of optimization,channel designs are improved through porous structures and micro-rib arrays,and flow rate distribution is optimized using splitters to balance pressure drop and heat transfer performance.This study provides theoretical support for microchannel thermal management in high-power-density devices.展开更多
In this study,the flow boiling characteristics of R1234yf in parallel microchannels were experimentally investigated.The experiments were conducted with heat flux from 0 to 550 kW/m^(2),mass flux of 434,727,and 1015 k...In this study,the flow boiling characteristics of R1234yf in parallel microchannels were experimentally investigated.The experiments were conducted with heat flux from 0 to 550 kW/m^(2),mass flux of 434,727,and 1015 kg/(m2 s),saturation temperatures of 293,298,and 303 K,and inlet sub-cooling of 5,10,and 15 K.The analysis of the experimental results provides the following conclusions:a reduced mass flux and lower subcooling correspond to a diminished degree of superheat at the boiling inception wall;conversely,an elevated saturation temperature results in a reduced amount of superheat at the boiling inception wall.Furthermore,an increase in sub-cooling and saturation temperature will enhance heat transfer efficiency.The wall temperature is mostly influenced by variations in saturation temperature and is minimally related to changes in mass flux and subcooling degree.An increase in mass flux results in a greater pressure drop attributed to heightened frictional pressure loss.The variation in pressure drop with respect to sub-cooling is minimal,while an increased saturation temperature correlates with a reduced pressure drop due to the formation of smaller bubbles and lowered frictional pressure loss at high saturation pressures.This study thoroughly examines and summarizes the effects of mass flow rate,saturation temperature,and subcooling on the flow-boiling heat transfer and pressure drop characteristics of R1234yf.Furthermore,the new correlation has 93.42%of the predicted values fall within a 15%mean absolute error,exhibiting a mean absolute error of 5.75%.It provides a superior method for predicting the flow-boiling heat transfer coefficients of R1234yf in the heat sink of parallel microchannels compared to existing correlations.展开更多
Flow boiling in open microchannels offers highly efficient heat transfer performance and has attracted increasing attention in the fields of heat transfer and thermalmanagement of electronic devices in recent years.Ho...Flow boiling in open microchannels offers highly efficient heat transfer performance and has attracted increasing attention in the fields of heat transfer and thermalmanagement of electronic devices in recent years.However,the continuous rise in power density of electronic components imposesmore stringent requirements on the heat transfer capability of microchannel flow boiling.HFE-7100,a dielectric coolant with favorable thermophysical properties,has become a focal point of research for enhancing flow boiling performance in open microchannels.The flow boiling heat transfer performance ofHFE-7100 was investigated in this study by fabricating micro-nano composite structures on the bottom surface of open microchannels using laser ablation technology.Based on visualization results,a comparative analysis was conducted on the bubble dynamics and flow pattern characteristics of HFE-7100 flow boiling in micronano structured open microchannels(MNSOMC)and smooth-surface open microchannels(SSOMC),to elucidate the enhancement mechanism of micro-nano structures on flow boiling heat transfer in open microchannels.The results indicate that the surface structures and strong wettability of MNSOMC accelerated bubble nucleation and departure.Moreover,bubbles in the channel tended to coalesce along the flow direction,forming elongated slug bubbles with high aspect ratios,which enabled efficient thin film evaporation in conjunction with intense nucleate boiling,thereby significantly enhancing flow boiling heat transfer.Under the experimental conditions of this study,the maximum enhancements in the heat transfer coefficient(HTC)and critical heat flux(CHF)of HFE-7100 inMNSOMC were 33.4%and 133.1%,respectively,with the CHF reaching up to 1542.3 kW⋅m^(−2).Furthermore,due to the superior wettability and capillary wicking capability of the micro-nano composite structures,the significant enhancement in flow boiling heat transfer was achieved without incurring a noticeable pressure drop penalty.展开更多
This experimental investigation was conducted on the flow boiling performance of refrigerant R134a in two types of parallel microchannels:sintered porous microchannels(PP-MCs)and smooth parallel microchannels(SP-MCs)....This experimental investigation was conducted on the flow boiling performance of refrigerant R134a in two types of parallel microchannels:sintered porous microchannels(PP-MCs)and smooth parallel microchannels(SP-MCs).The tests were performed under controlled conditions including an inlet subcooling of 5±0.2℃,saturation temperature of 33℃,mass fluxes of 346 and 485 kg/m2·s,and a range of heat fluxes.Key findings reveal that the sintered porous microstructure significantly enhances bubble nucleation,reducing the wall superheat required for the onset of nucleate boiling(ONB)to only 0.13℃ compared to 2.2℃ in smooth channels.The porous structure also improves heat transfer coefficients at low and medium heat fluxes(<20–30 W/cm^(2))and low vapor quality(x<0.2–0.4)due to augmented thin-film evaporation and intensified nucleate boiling.However,smooth microchannels exhibit superior performance under high heat flux and high vapor quality conditions,as the porous structure is prone to early dry-out and flow blockage.Notably,the porous microchannels demonstrate lower flow resistance and enhanced stability,with pressure drop fluctuations reduced by up to 46.4%in amplitude and 44.8%in standard deviation,attributed to improved capillary-assisted liquid replenishment and suppressed flow oscillations.The results underscore the potential of PP-MCs as a high-performance cooling solution for high-heat-flux applications.展开更多
Understanding the complex interaction between heat and mass transfer in non-Newtonian microflows is essential for the development and optimization of efficient microfluidic and thermal management systems.This study in...Understanding the complex interaction between heat and mass transfer in non-Newtonian microflows is essential for the development and optimization of efficient microfluidic and thermal management systems.This study investigates the magnetohydrodynamic(MHD)thermosolutal convection of a Casson fluid within an inclined,porous microchannel subjected to convective boundary conditions.The nonlinear,coupled equations governing momentum,energy,and species transport are solved numerically using the MATLAB bvp4c solver,ensuring high numerical accuracy and stability.To identify the dominant parameters influencing flow behavior and to optimize transport performance,a comprehensive hybrid optimization framework—combining a modified Taguchi design,Grey Relational Analysis(GRA),and Principal Component Analysis(PCA)—is proposed.This integrated strategy enables the simultaneous assessment of skin friction,Nusselt number,and Sherwood number,providing a rigorous multi-objective evaluation of system performance.Comparative validation with benchmark results from the literature confirms the accuracy and reliability of the present formulation and its numerical implementation.The results highlight the intricate coupling among flow slip,buoyancy effects,and convective transport mechanisms.Increased slip flow enhances axial velocity,while a higher solutal Biot number intensifies concentration gradients near the channel walls.Conversely,a lower thermal Biot number diminishes the temperature field,indicating weaker heat transfer across the boundaries.PCA results reveal that the first principal component(PC1)accounts for most of the system variance,demonstrating the dominant influence of coupled flow and transport parameters on overall system performance.展开更多
Deposition of diamond inside the trenches or microchannels by chemical vapor deposition (CVD) is limited by the diffusion efficiency of important radical species for diamond growth (H, CH3) and the pore depth of t...Deposition of diamond inside the trenches or microchannels by chemical vapor deposition (CVD) is limited by the diffusion efficiency of important radical species for diamond growth (H, CH3) and the pore depth of the substrate template. By ultrasonic seeding with nanodiamond suspension, three-dimensional (3D) penetration structure diamond was successfully deposited in cylindrical microchannels of Cu template by hot-filament chemical vapor deposition. Micro-Raman spectroscopy and scanning electron microscopy (SEM) were used to characterize diamond film and the effects of microchannel depth on the morphology, grain size and growth rate of diamond film were comprehensively investigated. The results show that diamond quality and growth rate sharply decrease with the increase of the depth of cylindrical microchannel. Individual diamond grain develops gradually from faceted crystals into micrometer cluster, and finally to ballas-type nanocrystalline one. In order to modify the rapid decrease of diamond quality and growth rate, a new hot filament apparatus with a forced gas flow through Cu microchannels was designed. Furthermore, the growth of diamond film by new apparatus was compared with that without a forced gas flow, and the enhancement mechanism was discussed.展开更多
In order to establish the relationship between the measured dynamic response and the health status of long-span bridges, a double-layer model updating method for steel-concrete composite beam cable-stayed bridges is p...In order to establish the relationship between the measured dynamic response and the health status of long-span bridges, a double-layer model updating method for steel-concrete composite beam cable-stayed bridges is proposed. Measured frequencies are selected as the first-layer reference data, and the mass of the bridge deck, the grid density, the modulus of concrete and the ballast on the side span are modified by using a manual tuning technique. Measured global positioning system (GPS) data is selected as the second-layer reference data, and the degradation of the integral structure stiffness EI of the whole bridge is taken into account for the second-layer model updating by using the finite element iteration algorithm. The Nanpu Bridge in Shanghai is taken as a case to verify the applicability of the proposed model updating method. After the first-layer model updating, the standard deviation of modal frequencies is smaller than 7%. After the second-layer model updating, the error of the deflection of the mid-span is smaller than 10%. The integral structure stiffness of the whole bridge decreases about 20%. The research results show a good agreement between the calculated response and the measured response.展开更多
In order to increase the fatigue life (FL) of road wheels (RW), a kind of double layer rubber flange (DLRF) is put forward. It consists of two layers of rubber, where metal wires are laid in the inner layer and the ou...In order to increase the fatigue life (FL) of road wheels (RW), a kind of double layer rubber flange (DLRF) is put forward. It consists of two layers of rubber, where metal wires are laid in the inner layer and the outer layer has no inlaid metal wires. Stress, strain and temperature field of DLRF were calculated with ANSYS finite element analysis (FEA) software, FL of DLRF RW was also computed with fracture mechanics fatigue theory. The results of computation indicate that the heat generated in RW's rubber flange (RF) can be reduced by the use of DLRF, and the FL of RW can be increased without affecting the mechanical intensity of RW.展开更多
Compared with the classic flow on macroscale, flows in microchannels have some new phenomena such as the friction increase and the flow rate reduction. Papautsky and co-workers explained these phenomena by using a mic...Compared with the classic flow on macroscale, flows in microchannels have some new phenomena such as the friction increase and the flow rate reduction. Papautsky and co-workers explained these phenomena by using a micropolar fluid model where the effects of micro-rotation of fluid molecules were taken into account. But both the curl of velocity vector and the curl of micro-rotation gyration vector were given incorrectly in the Cartesian coordinates and then the micro-rotation gyration vector had only one component in the z-direction. Besides, the gradient term of the divergence of micro-rotation gyration vector was missed improperly in the angular moment equation. In this paper, the governing equations for laminar flows of micropolar fluid in rectangular microchannels are reconstructed. The numerical results of velocity profiles and micro-rotation gyrations are obtained by a procedure based on the Chebyshev collocation method. The micropolar effects on velocity and micro-rotation gyration are discussed in detail.展开更多
This paper experimentally investigates the effect of surface roughness on flow and heat transfer characteristics in circular microchannels. All test pieces include 44 identical, parallel circular microchannels with di...This paper experimentally investigates the effect of surface roughness on flow and heat transfer characteristics in circular microchannels. All test pieces include 44 identical, parallel circular microchannels with diameters of 0.4 mm and 10 mm in length. The surface roughness of the microchannels is R= 0.86, 0.92, 1.02 lm, and the Reynolds number ranges from 150 to 2800.Results show that the surface roughness of the circular microchannels has remarkable effects on the performance of flow behavior and heat transfer. It is found that the Poiseuille and Nusselt numbers are higher when the relative surface roughness is larger. For flow behavior, the friction factor increases consistently with the increasing Reynolds number, and it is larger than the constant theoretical value for macrochannels. The Reynolds number for the transition from laminar to turbulent flow is about 1500, which is lower than the value for macrochannels. For the heat transfer property, Nusselt number also increases with increasing Reynolds number, and larger roughness contributes to higher Nusselt number.展开更多
Experiments were carried out to investigate the boiling heat transfer characteristics of Al_2O_3-water nanofluids in swirl microchannels under terrestrial gravity and acceleration fields. A centrifuge with a two-meter...Experiments were carried out to investigate the boiling heat transfer characteristics of Al_2O_3-water nanofluids in swirl microchannels under terrestrial gravity and acceleration fields. A centrifuge with a two-meter long rotational arm was used to simulate the acceleration magnitude up to 9 g and three various acceleration directions. Three test sections with different geometric parameters were applied. The volume concentration of Al_2O_3 nanoparticles with an average diameter of 13 nm was varied from 0.07% to 0.1%. The mass flow rate and vapor quality were in ranges of 3–6 kg/h and 0.4–1.0%, respectively. The effects of the mass flow rate, microchannel aspect ratio,vapor quality, nanoparticle volume concentration, and acceleration direction and magnitude were analyzed in a systematic manner. Experimental results showed that the acceleration direction and magnitude had significant influences on the boiling heat transfer. The heat transfer under configuration C was found to be superior to that under configurations A and B. Moreover, the heat transfer coefficient increased with increases of the mass flow rate and the volume concentration and decreased with the aspect ratio.展开更多
The aim of the study was to develop actarit double-layered osmotic pump tablets to overcome the weak points of actarit common tablets, such as short half-life and large plasma concentration fluctuations. Single factor...The aim of the study was to develop actarit double-layered osmotic pump tablets to overcome the weak points of actarit common tablets, such as short half-life and large plasma concentration fluctuations. Single factor experiment and orthogonal test were applied to optimize the formulation;the pharmacokinetic study was performed in beagle dogs adopting actarit common tablets as reference tablets. The optimal formulation was as follows: drug layer: 150 mg actarit, 240 mg PEO-N80, 50 mg NaCl;push layer: 140 mg PEO-WSR303, 20 mg NaCl;coating solution: 30 g cellulose acetate and 6 g PEG 4000 in 1000 ml 94% acetone solution, 60 mg coating weight gain. The pharmacokinetic study showed that T max was prolonged by the contrast of commercial common tablets with constant drug release rate, but the bioavailability was equivalent. And a good in vivo –in vitro correlation of the actarit osmotic pump tablets was also established. The designed actarit osmotic pump tablets can be applied for rheumatoid arthritis, proposing a promising replacement for the marked common products.展开更多
The pressure drop of gas-liquid two-phase flow in microchannel is of fundamental importance in heat and mass transfer processes. In this work,the pressure drop of gas-liquid two-phase flow in horizontal rectangular cr...The pressure drop of gas-liquid two-phase flow in microchannel is of fundamental importance in heat and mass transfer processes. In this work,the pressure drop of gas-liquid two-phase flow in horizontal rectangular cross-section microchannels was measured by a pressure differential transducer system. Water,ethanol and n-propanol were used as liquid phase to study the effects of capillary number on pressure drop;air was used as the gas phase. Four microchannels with various dimensions of 100 μm× 200 μm,100 μm× 400 μm,100 μm× 800 μm and 100 μm× 2000 μm(depth × width) were used for determining the influence of configuration on the pressure drop. Experimental results showed that in micro-scale,the capillary number also affected the pressure drop remarkably,and in spite of only one-fold difference in aspect ratio,the variation of pressure drop reached up to near three times under the same experimental conditions. Taking the effects of aspect ratio and surface tension into account,a modi-fied correlation for Chisholm parameter C in the Chisholm model was proposed for predicting the frictional multi-plier,and the predicted values by the proposed correlation showed a satisfactory agreement with experimental data.展开更多
AIM To investigate the efficacy of double-layered covered stent in the treatment of malignant oesophageal obstructions.METHODS A systematic review and meta-analysis was performed following the PRISMA process. Pub Med(...AIM To investigate the efficacy of double-layered covered stent in the treatment of malignant oesophageal obstructions.METHODS A systematic review and meta-analysis was performed following the PRISMA process. Pub Med(Medline),EMBASE(Excerpta Medical Database),AMED(Allied and Complementary medicine Database),Scopus and online content,were searched for studies reporting on the Ni Ti-S polyurethane-covered double oesophageal stent for the treatment of malignant dysphagia. Weighted pooled outcomes were synthesized with a random effects model to account for clinical heterogeneity. All studies reporting the outcome of palliative management of dysphagia due to histologically confirmed malignant oesophageal obstruction using double-layered covered nitinol stent were included. The level of statistical significance was set at α = 0.05.RESULTS Six clinical studies comprising 250 patients in total were identified. Pooled technical success of stent insertion was 97.2%(95%CI: 94.8%-98.9%; I2 = 5.8%). Pooled complication rate was 27.6%(95%CI: 20.7%-35.2%; I2 = 41.9%). Weighted improvement of dysphagia on a scale of 0-5 scoring system was-2.00 [95%CI:-2.29%-(-1.72%); I2 = 87%]. Distal stent migration was documented in 10 out of the 250 cases examined.Pooled stent migration rate was 4.7%(95%CI: 2.5%-7.7%; I2 = 0%). Finally,tumour overgrowth was reported in 34 out of the 250 cases with pooled rate of tumour overgrowth of 11.2%(95%CI: 3.7%-22.1%; I2 = 82.2%). No funnel plot asymmetry to suggest publication bias(bias = 0.39,P = 0.78). In the sensitivity analysis all results were largely similar between the fixed and random effects models.CONCLUSION The double-layered nitinol stent provides immediate relief of malignant dysphagia with low rates of stent migration and tumour展开更多
In this paper the mixing of a sample in the curved microchannel with heterogeneous surface potentials is analysed numerically by using the control-volume-based finite difference method. The rigorous models for describ...In this paper the mixing of a sample in the curved microchannel with heterogeneous surface potentials is analysed numerically by using the control-volume-based finite difference method. The rigorous models for describing the wall potential and external potential are solved to get the distribution of wall potential and external potential, then momentum equation is solved to get the fully developed flow field. Finally the mass transport equation is solved to get the concentration field. The results show that the curved microchannel has an optimized capability of sample mixing and transport when the heterogeneous surface is located at the left conjunction between the curved part and straight part. The variation of heterogeneous surface potential ψn has more influence on the capability of sample mixing than on that of sample transport. The ratio of the curved microchanners radius to width has a comparable effect on the capability of sample mixing and transport. The conclusions above are helpful to the optimization of the design of microfluidic devices for the improvement of the efficiency of sample mixing.展开更多
Based on non-Darcian flow law described by exponent and threshold gradient within a double-layered soil, the classic theory of one-dimensional consolidation of double-layered soil was modified to consider the change o...Based on non-Darcian flow law described by exponent and threshold gradient within a double-layered soil, the classic theory of one-dimensional consolidation of double-layered soil was modified to consider the change of vertical total stress with depth and time together. Because of the complexity of governing equations, the numerical solutions were obtained in detail by finite difference method. Then, the numerical solutions were compared with the analytical solutions in condition that non-Darcian flow law was degenerated to Dary's law, and the comparison results show that numerical solutions are reliable. Finally, consolidation behavior of double-layered soil with different parameters was analyzed, and the results show that the consolidation rate of double-layered soil decreases with increasing the value of exponent and threshold of non-Darcian flow, and the exponent and threshold gradient of the first soil layer greatly influence the consolidation rate of double-layered soil. The larger the ratio of the equivalent water head of external load to the total thickness of double-layered soil, the larger the rate of the consolidation, and the similitude relationship in classical consolidation theory of double-layered soil is not satisfied. The other consolidation behavior of double-layered soil with non-Darcian flow is the same as that with Darcy's law.展开更多
文摘The pivotal role microchannels play in the thermal management of electronic components has,in recent decades,prompted extensive research into methods for enhancing their heat transfer performance.Among these methods,surface wettability modification was found to be highly effective owing to its significant influence on boiling dynamics and heat transfer mechanisms.In this study,we modified surface wettability using a nanocomposite coating composed of graphene nano plate(GNPs)and multi-walled carbon nanotubes(MWCNT)and then examined how the modification affected the transfer of boiling heat in microchannels.The resultant heat transfer coefficients for hydrophilic and hydrophilic composite(GNPs+MWCNT)microchannels were,respectively,42.8%and 33.95%higher compared with that of the uncoated surface.These results verify that hydrophilic GNP-based coating significantly improves boiling heat transfer performance.It was observed that a minor increase in contact angle,θfrom 73.142°to 75.73°,resulted in a noticeable decrease in thermal performance.This is attributed to diminished liquid film stability,reduced nucleation site activity,and weakened capillary-driven liquid replenishment.These findings underscore the crucial role of optimized surface wettability in maintaining efficient microchannel boiling.At high mass flux,the GNPS microchannels exhibited maximum pressure drop values,with a pressure drop ratio as high as 36%compared to 29%for the GNPs+MWCNT composite samples.Nevertheless,when a composite hydrophilic–hydrophobic coating was deposited through electrodeposition,the enhancement in heat transfer was less significant.This was probably due to decreased surface uniformity,diminished liquid film stability,and the disruption of effective nucleation behavior,all associated with the slight increase in surface contact angle.The obtained results can be used as guidance for designing advanced cooling surfaces in high-performance microelectronic and energy systems,where precise control of surface characteristics is critical.
基金funded by the National Natural Science Foundation of China(Project No.62273289)The Youth Innovation Science and Technology Support Program of Shandong Province(Project No.2022KJ274)+1 种基金Natural Science Foundation of Shandong Province(Grant No.ZR2024MF007)Graduate Innovation Foundation of Yantai University,GIFYTU.
文摘The design and manufacturing of microchannels are crucial aspects of modern micro/nanomanufacturing processes,offering a versatile platform for manipulating and driving micro/nanoparticles or cells.In this study,we propose a method for manufacturing microchannels using optically induced dielectrophoresis technology to induce the polymerization of polyethylene glycol diacrylate solution.To overcome limitations related to the light intensity energy and the size of intact microchannels,we design and manufacture microstructures of various shapes with a height of 4µm.Additionally,we simulate and analyze the movement of and forces acting on polystyrene(PS)microspheres at different spatial positions within the microchannels.Finally,we successfully demonstrate applications involving the transport of PS microspheres in custom-fabricated microchannels.This novel biocompatible microchannel manufacturing method is simple and non-biotoxic.It provides a new approach for simulating physiological environments in vitro and cultivating and manipulating cells.
基金support from National Key Research and Development Program of China(2023YFC3905400)the Strategic Priority Research Program of the Chinese Academy of Sciences(XDA0490102)National Natural Science Foundation of China(22178354,2242100322408374).
文摘Integrating Bayesian Optimization with Volume of Fluid (VOF) simulations, this work aims to optimize the operational conditions and geometric parameters of T-junction microchannels for target droplet sizes. Bayesian Optimization utilizes Gaussian Process (GP) as its core model and employs an adaptive search strategy to efficiently explore and identify optimal combinations of operational parameters within a limited parameter space, thereby enabling rapid optimization of the required parameters to achieve the target droplet size. Traditional methods typically rely on manually selecting a series of operational parameters and conducting multiple simulations to gradually approach the target droplet size. This process is time-consuming and prone to getting trapped in local optima. In contrast, Bayesian Optimization adaptively adjusts its search strategy, significantly reducing computational costs and effectively exploring global optima, thus greatly improving optimization efficiency. Additionally, the study investigates the impact of rectangular rib structures within the T-junction microchannel on droplet generation, revealing how the channel geometry influences droplet formation and size. After determining the target droplet size, we further applied Bayesian Optimization to refine the rib geometry. The integration of Bayesian Optimization with computational fluid dynamics (CFD) offers a promising tool and provides new insights into the optimal design of microfluidic devices.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.12074213 and 11574108)the National Key R&D Program of China(Grant No.2022YFA1403103)+2 种基金the Major Basic Program of Natural Science Foundation of Shandong Province(Grant No.ZR2021ZD01)the Natural Science Foundation of Shandong Province(Grant No.ZR2023MA082)the Project of Introduction and Cultivation for Young Innovative Talents in Colleges and Universities of Shandong Province。
文摘Two-dimensional double-layer honeycomb(DLHC)materials are known for their diverse physical properties,but superconductivity has been a notably absent characteristic in this structure.We address this gap by investigating M_(2)N_(2)(M=Nb,Ta)with DLHC structure using first-principles calculations.Our results show that M_(2)N_(2)are stable and metallic,exhibiting superconducting behavior.Specifically,Nb_(2)N_(2)and Ta_(2)N_(2)display superconducting transition temperatures of 6.8 K and 8.8 K,respectively.Their electron-phonon coupling is predominantly driven by the coupling between metal d-orbitals and low-frequency metal-dominated vibration modes.Interestingly,two compounds also exhibit non-trivial band topology.Thus,M_(2)N_(2)are promising platforms for studying the interplay between topology and superconductivity and fill the gap in superconductivity research for DLHC materials.
基金supported by the Beijing Municipal Science&Technology Commission(Z231100006123010).
文摘With the increasing miniaturization of systems and surging demand for power density,accurate prediction and control of two-phase flow pressure drop have become a core challenge restricting the performance of microchannel heat exchangers.Pressure drop,a critical hydraulic characteristic,serves as both a natural constraint for cooling systems and determines the power required to pump the working fluid through microchannels.This paper reviews the characteristics,prediction models,and optimization measures of two-phase flow pressure drop for low-boiling-point working fluids in microchannels.It systematically analyzes key influencing factors such as fluid physical properties,operating conditions,channel geometry,and flow patterns,and discusses the complex mechanisms of pressure drop under the coupling effect of multi-physical fields.Mainstream prediction models are reviewed:the homogeneous flow model simplifies calculations but shows large deviations at low quality;the separated flow model considers interphase interactions and can be applied to micro-scales after modification;the flow-pattern-based model performs zoned modeling but relies on subjective classification;machine learning improves prediction accuracy but faces the“black-box”problem.In terms of optimization,channel designs are improved through porous structures and micro-rib arrays,and flow rate distribution is optimized using splitters to balance pressure drop and heat transfer performance.This study provides theoretical support for microchannel thermal management in high-power-density devices.
基金supported by the Beijing Municipal Science&Technology Commission(Z231100006123010).
文摘In this study,the flow boiling characteristics of R1234yf in parallel microchannels were experimentally investigated.The experiments were conducted with heat flux from 0 to 550 kW/m^(2),mass flux of 434,727,and 1015 kg/(m2 s),saturation temperatures of 293,298,and 303 K,and inlet sub-cooling of 5,10,and 15 K.The analysis of the experimental results provides the following conclusions:a reduced mass flux and lower subcooling correspond to a diminished degree of superheat at the boiling inception wall;conversely,an elevated saturation temperature results in a reduced amount of superheat at the boiling inception wall.Furthermore,an increase in sub-cooling and saturation temperature will enhance heat transfer efficiency.The wall temperature is mostly influenced by variations in saturation temperature and is minimally related to changes in mass flux and subcooling degree.An increase in mass flux results in a greater pressure drop attributed to heightened frictional pressure loss.The variation in pressure drop with respect to sub-cooling is minimal,while an increased saturation temperature correlates with a reduced pressure drop due to the formation of smaller bubbles and lowered frictional pressure loss at high saturation pressures.This study thoroughly examines and summarizes the effects of mass flow rate,saturation temperature,and subcooling on the flow-boiling heat transfer and pressure drop characteristics of R1234yf.Furthermore,the new correlation has 93.42%of the predicted values fall within a 15%mean absolute error,exhibiting a mean absolute error of 5.75%.It provides a superior method for predicting the flow-boiling heat transfer coefficients of R1234yf in the heat sink of parallel microchannels compared to existing correlations.
基金funded by the National Natural Science Foundation of China(Grant No.52276047)the Open Fund of NationalKey Laboratory of SpacecraftThermal Control(Grant No.NKLST-JJ-202401011)the Beijing Municipal Science&Technology Commission(Grant No.Z231100006123010).
文摘Flow boiling in open microchannels offers highly efficient heat transfer performance and has attracted increasing attention in the fields of heat transfer and thermalmanagement of electronic devices in recent years.However,the continuous rise in power density of electronic components imposesmore stringent requirements on the heat transfer capability of microchannel flow boiling.HFE-7100,a dielectric coolant with favorable thermophysical properties,has become a focal point of research for enhancing flow boiling performance in open microchannels.The flow boiling heat transfer performance ofHFE-7100 was investigated in this study by fabricating micro-nano composite structures on the bottom surface of open microchannels using laser ablation technology.Based on visualization results,a comparative analysis was conducted on the bubble dynamics and flow pattern characteristics of HFE-7100 flow boiling in micronano structured open microchannels(MNSOMC)and smooth-surface open microchannels(SSOMC),to elucidate the enhancement mechanism of micro-nano structures on flow boiling heat transfer in open microchannels.The results indicate that the surface structures and strong wettability of MNSOMC accelerated bubble nucleation and departure.Moreover,bubbles in the channel tended to coalesce along the flow direction,forming elongated slug bubbles with high aspect ratios,which enabled efficient thin film evaporation in conjunction with intense nucleate boiling,thereby significantly enhancing flow boiling heat transfer.Under the experimental conditions of this study,the maximum enhancements in the heat transfer coefficient(HTC)and critical heat flux(CHF)of HFE-7100 inMNSOMC were 33.4%and 133.1%,respectively,with the CHF reaching up to 1542.3 kW⋅m^(−2).Furthermore,due to the superior wettability and capillary wicking capability of the micro-nano composite structures,the significant enhancement in flow boiling heat transfer was achieved without incurring a noticeable pressure drop penalty.
基金ported by the Beijing Municipal Science&Technology Commission(Z231100006123010)Guizhou Provincial Major Scientific and Technological Program(XKBF(2025)031)a grant from Tianjin Key Laboratory of Refrigeration Technology(2025TKLRT002).
文摘This experimental investigation was conducted on the flow boiling performance of refrigerant R134a in two types of parallel microchannels:sintered porous microchannels(PP-MCs)and smooth parallel microchannels(SP-MCs).The tests were performed under controlled conditions including an inlet subcooling of 5±0.2℃,saturation temperature of 33℃,mass fluxes of 346 and 485 kg/m2·s,and a range of heat fluxes.Key findings reveal that the sintered porous microstructure significantly enhances bubble nucleation,reducing the wall superheat required for the onset of nucleate boiling(ONB)to only 0.13℃ compared to 2.2℃ in smooth channels.The porous structure also improves heat transfer coefficients at low and medium heat fluxes(<20–30 W/cm^(2))and low vapor quality(x<0.2–0.4)due to augmented thin-film evaporation and intensified nucleate boiling.However,smooth microchannels exhibit superior performance under high heat flux and high vapor quality conditions,as the porous structure is prone to early dry-out and flow blockage.Notably,the porous microchannels demonstrate lower flow resistance and enhanced stability,with pressure drop fluctuations reduced by up to 46.4%in amplitude and 44.8%in standard deviation,attributed to improved capillary-assisted liquid replenishment and suppressed flow oscillations.The results underscore the potential of PP-MCs as a high-performance cooling solution for high-heat-flux applications.
文摘Understanding the complex interaction between heat and mass transfer in non-Newtonian microflows is essential for the development and optimization of efficient microfluidic and thermal management systems.This study investigates the magnetohydrodynamic(MHD)thermosolutal convection of a Casson fluid within an inclined,porous microchannel subjected to convective boundary conditions.The nonlinear,coupled equations governing momentum,energy,and species transport are solved numerically using the MATLAB bvp4c solver,ensuring high numerical accuracy and stability.To identify the dominant parameters influencing flow behavior and to optimize transport performance,a comprehensive hybrid optimization framework—combining a modified Taguchi design,Grey Relational Analysis(GRA),and Principal Component Analysis(PCA)—is proposed.This integrated strategy enables the simultaneous assessment of skin friction,Nusselt number,and Sherwood number,providing a rigorous multi-objective evaluation of system performance.Comparative validation with benchmark results from the literature confirms the accuracy and reliability of the present formulation and its numerical implementation.The results highlight the intricate coupling among flow slip,buoyancy effects,and convective transport mechanisms.Increased slip flow enhances axial velocity,while a higher solutal Biot number intensifies concentration gradients near the channel walls.Conversely,a lower thermal Biot number diminishes the temperature field,indicating weaker heat transfer across the boundaries.PCA results reveal that the first principal component(PC1)accounts for most of the system variance,demonstrating the dominant influence of coupled flow and transport parameters on overall system performance.
基金Project(21271188) supported by the Nature Science Foundation of China
文摘Deposition of diamond inside the trenches or microchannels by chemical vapor deposition (CVD) is limited by the diffusion efficiency of important radical species for diamond growth (H, CH3) and the pore depth of the substrate template. By ultrasonic seeding with nanodiamond suspension, three-dimensional (3D) penetration structure diamond was successfully deposited in cylindrical microchannels of Cu template by hot-filament chemical vapor deposition. Micro-Raman spectroscopy and scanning electron microscopy (SEM) were used to characterize diamond film and the effects of microchannel depth on the morphology, grain size and growth rate of diamond film were comprehensively investigated. The results show that diamond quality and growth rate sharply decrease with the increase of the depth of cylindrical microchannel. Individual diamond grain develops gradually from faceted crystals into micrometer cluster, and finally to ballas-type nanocrystalline one. In order to modify the rapid decrease of diamond quality and growth rate, a new hot filament apparatus with a forced gas flow through Cu microchannels was designed. Furthermore, the growth of diamond film by new apparatus was compared with that without a forced gas flow, and the enhancement mechanism was discussed.
基金The Special Project of the Ministry of Construction ofChina (No.20060909).
文摘In order to establish the relationship between the measured dynamic response and the health status of long-span bridges, a double-layer model updating method for steel-concrete composite beam cable-stayed bridges is proposed. Measured frequencies are selected as the first-layer reference data, and the mass of the bridge deck, the grid density, the modulus of concrete and the ballast on the side span are modified by using a manual tuning technique. Measured global positioning system (GPS) data is selected as the second-layer reference data, and the degradation of the integral structure stiffness EI of the whole bridge is taken into account for the second-layer model updating by using the finite element iteration algorithm. The Nanpu Bridge in Shanghai is taken as a case to verify the applicability of the proposed model updating method. After the first-layer model updating, the standard deviation of modal frequencies is smaller than 7%. After the second-layer model updating, the error of the deflection of the mid-span is smaller than 10%. The integral structure stiffness of the whole bridge decreases about 20%. The research results show a good agreement between the calculated response and the measured response.
文摘In order to increase the fatigue life (FL) of road wheels (RW), a kind of double layer rubber flange (DLRF) is put forward. It consists of two layers of rubber, where metal wires are laid in the inner layer and the outer layer has no inlaid metal wires. Stress, strain and temperature field of DLRF were calculated with ANSYS finite element analysis (FEA) software, FL of DLRF RW was also computed with fracture mechanics fatigue theory. The results of computation indicate that the heat generated in RW's rubber flange (RF) can be reduced by the use of DLRF, and the FL of RW can be increased without affecting the mechanical intensity of RW.
基金The project was supported by the National Natural Science Foundation of China (10472054). The English text was polished by Boyi Wang
文摘Compared with the classic flow on macroscale, flows in microchannels have some new phenomena such as the friction increase and the flow rate reduction. Papautsky and co-workers explained these phenomena by using a micropolar fluid model where the effects of micro-rotation of fluid molecules were taken into account. But both the curl of velocity vector and the curl of micro-rotation gyration vector were given incorrectly in the Cartesian coordinates and then the micro-rotation gyration vector had only one component in the z-direction. Besides, the gradient term of the divergence of micro-rotation gyration vector was missed improperly in the angular moment equation. In this paper, the governing equations for laminar flows of micropolar fluid in rectangular microchannels are reconstructed. The numerical results of velocity profiles and micro-rotation gyrations are obtained by a procedure based on the Chebyshev collocation method. The micropolar effects on velocity and micro-rotation gyration are discussed in detail.
文摘This paper experimentally investigates the effect of surface roughness on flow and heat transfer characteristics in circular microchannels. All test pieces include 44 identical, parallel circular microchannels with diameters of 0.4 mm and 10 mm in length. The surface roughness of the microchannels is R= 0.86, 0.92, 1.02 lm, and the Reynolds number ranges from 150 to 2800.Results show that the surface roughness of the circular microchannels has remarkable effects on the performance of flow behavior and heat transfer. It is found that the Poiseuille and Nusselt numbers are higher when the relative surface roughness is larger. For flow behavior, the friction factor increases consistently with the increasing Reynolds number, and it is larger than the constant theoretical value for macrochannels. The Reynolds number for the transition from laminar to turbulent flow is about 1500, which is lower than the value for macrochannels. For the heat transfer property, Nusselt number also increases with increasing Reynolds number, and larger roughness contributes to higher Nusselt number.
基金the financial support from the Youth Talent Plan of Beijing of China (No. YETP 1087)
文摘Experiments were carried out to investigate the boiling heat transfer characteristics of Al_2O_3-water nanofluids in swirl microchannels under terrestrial gravity and acceleration fields. A centrifuge with a two-meter long rotational arm was used to simulate the acceleration magnitude up to 9 g and three various acceleration directions. Three test sections with different geometric parameters were applied. The volume concentration of Al_2O_3 nanoparticles with an average diameter of 13 nm was varied from 0.07% to 0.1%. The mass flow rate and vapor quality were in ranges of 3–6 kg/h and 0.4–1.0%, respectively. The effects of the mass flow rate, microchannel aspect ratio,vapor quality, nanoparticle volume concentration, and acceleration direction and magnitude were analyzed in a systematic manner. Experimental results showed that the acceleration direction and magnitude had significant influences on the boiling heat transfer. The heat transfer under configuration C was found to be superior to that under configurations A and B. Moreover, the heat transfer coefficient increased with increases of the mass flow rate and the volume concentration and decreased with the aspect ratio.
文摘The aim of the study was to develop actarit double-layered osmotic pump tablets to overcome the weak points of actarit common tablets, such as short half-life and large plasma concentration fluctuations. Single factor experiment and orthogonal test were applied to optimize the formulation;the pharmacokinetic study was performed in beagle dogs adopting actarit common tablets as reference tablets. The optimal formulation was as follows: drug layer: 150 mg actarit, 240 mg PEO-N80, 50 mg NaCl;push layer: 140 mg PEO-WSR303, 20 mg NaCl;coating solution: 30 g cellulose acetate and 6 g PEG 4000 in 1000 ml 94% acetone solution, 60 mg coating weight gain. The pharmacokinetic study showed that T max was prolonged by the contrast of commercial common tablets with constant drug release rate, but the bioavailability was equivalent. And a good in vivo –in vitro correlation of the actarit osmotic pump tablets was also established. The designed actarit osmotic pump tablets can be applied for rheumatoid arthritis, proposing a promising replacement for the marked common products.
基金Supported by the National Natural Science Foundation of China (20876107) the Opening Project of State Key Laboratory of Chemical Engineering (SKL-ChE-08B06)
文摘The pressure drop of gas-liquid two-phase flow in microchannel is of fundamental importance in heat and mass transfer processes. In this work,the pressure drop of gas-liquid two-phase flow in horizontal rectangular cross-section microchannels was measured by a pressure differential transducer system. Water,ethanol and n-propanol were used as liquid phase to study the effects of capillary number on pressure drop;air was used as the gas phase. Four microchannels with various dimensions of 100 μm× 200 μm,100 μm× 400 μm,100 μm× 800 μm and 100 μm× 2000 μm(depth × width) were used for determining the influence of configuration on the pressure drop. Experimental results showed that in micro-scale,the capillary number also affected the pressure drop remarkably,and in spite of only one-fold difference in aspect ratio,the variation of pressure drop reached up to near three times under the same experimental conditions. Taking the effects of aspect ratio and surface tension into account,a modi-fied correlation for Chisholm parameter C in the Chisholm model was proposed for predicting the frictional multi-plier,and the predicted values by the proposed correlation showed a satisfactory agreement with experimental data.
文摘AIM To investigate the efficacy of double-layered covered stent in the treatment of malignant oesophageal obstructions.METHODS A systematic review and meta-analysis was performed following the PRISMA process. Pub Med(Medline),EMBASE(Excerpta Medical Database),AMED(Allied and Complementary medicine Database),Scopus and online content,were searched for studies reporting on the Ni Ti-S polyurethane-covered double oesophageal stent for the treatment of malignant dysphagia. Weighted pooled outcomes were synthesized with a random effects model to account for clinical heterogeneity. All studies reporting the outcome of palliative management of dysphagia due to histologically confirmed malignant oesophageal obstruction using double-layered covered nitinol stent were included. The level of statistical significance was set at α = 0.05.RESULTS Six clinical studies comprising 250 patients in total were identified. Pooled technical success of stent insertion was 97.2%(95%CI: 94.8%-98.9%; I2 = 5.8%). Pooled complication rate was 27.6%(95%CI: 20.7%-35.2%; I2 = 41.9%). Weighted improvement of dysphagia on a scale of 0-5 scoring system was-2.00 [95%CI:-2.29%-(-1.72%); I2 = 87%]. Distal stent migration was documented in 10 out of the 250 cases examined.Pooled stent migration rate was 4.7%(95%CI: 2.5%-7.7%; I2 = 0%). Finally,tumour overgrowth was reported in 34 out of the 250 cases with pooled rate of tumour overgrowth of 11.2%(95%CI: 3.7%-22.1%; I2 = 82.2%). No funnel plot asymmetry to suggest publication bias(bias = 0.39,P = 0.78). In the sensitivity analysis all results were largely similar between the fixed and random effects models.CONCLUSION The double-layered nitinol stent provides immediate relief of malignant dysphagia with low rates of stent migration and tumour
基金Project supported by the National Natural Science Foundation (Grant No 10372090) and the Doctoral Program of Higher Education of China (Grant No 20030335001).
文摘In this paper the mixing of a sample in the curved microchannel with heterogeneous surface potentials is analysed numerically by using the control-volume-based finite difference method. The rigorous models for describing the wall potential and external potential are solved to get the distribution of wall potential and external potential, then momentum equation is solved to get the fully developed flow field. Finally the mass transport equation is solved to get the concentration field. The results show that the curved microchannel has an optimized capability of sample mixing and transport when the heterogeneous surface is located at the left conjunction between the curved part and straight part. The variation of heterogeneous surface potential ψn has more influence on the capability of sample mixing than on that of sample transport. The ratio of the curved microchanners radius to width has a comparable effect on the capability of sample mixing and transport. The conclusions above are helpful to the optimization of the design of microfluidic devices for the improvement of the efficiency of sample mixing.
基金Projects(50878191,51109092)supported by the National Natural Science Foundation of China
文摘Based on non-Darcian flow law described by exponent and threshold gradient within a double-layered soil, the classic theory of one-dimensional consolidation of double-layered soil was modified to consider the change of vertical total stress with depth and time together. Because of the complexity of governing equations, the numerical solutions were obtained in detail by finite difference method. Then, the numerical solutions were compared with the analytical solutions in condition that non-Darcian flow law was degenerated to Dary's law, and the comparison results show that numerical solutions are reliable. Finally, consolidation behavior of double-layered soil with different parameters was analyzed, and the results show that the consolidation rate of double-layered soil decreases with increasing the value of exponent and threshold of non-Darcian flow, and the exponent and threshold gradient of the first soil layer greatly influence the consolidation rate of double-layered soil. The larger the ratio of the equivalent water head of external load to the total thickness of double-layered soil, the larger the rate of the consolidation, and the similitude relationship in classical consolidation theory of double-layered soil is not satisfied. The other consolidation behavior of double-layered soil with non-Darcian flow is the same as that with Darcy's law.