期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
THEORETICAL INVESTIGATION ON STATE OF LOAD DISTRIBUTION AMONG CONTACT BEARINGS OF DOUBLE CIRCULAR ARC HELICAL GEARS 被引量:3
1
作者 Wu Baolin (Gear Research Institute, Taiyuan University of Technology) 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2000年第2期108-113,共6页
A dynamic analysis approcach to investigate the state of load distribution among contact bearings of double circular are belical gears is proposed and a computer program is developed for calculating the factor of iced... A dynamic analysis approcach to investigate the state of load distribution among contact bearings of double circular are belical gears is proposed and a computer program is developed for calculating the factor of iced distribution based on the theory of W-N gears. The changing situations of load distribution among contact bearings of the gears influenced by main issues are analyzed by a series of parametric studies. 展开更多
关键词 double circular are belical gears State of load distribution Factor of load distribution Dynamic analysis
在线阅读 下载PDF
Crack spacing threshold of double cracks propagation for large-module rack
2
作者 赵铁柱 石端伟 +3 位作者 姚哲皓 毛宏勇 程术潇 彭惠 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第7期2533-2539,共7页
Large-module rack of the Three Gorges shiplift is manufactured by casting and machining, which is unable to avoid slag inclusions and surface cracks. To ensure its safety in the future service, studying on crack propa... Large-module rack of the Three Gorges shiplift is manufactured by casting and machining, which is unable to avoid slag inclusions and surface cracks. To ensure its safety in the future service, studying on crack propagation rule and the residual life estimation method of large-module rack is of great significance. The possible crack distribution forms of the rack in the Three Gorges shiplift were studied. By applying moving load on the model in FRANC3 D and ANSYS, quantitative analyses of interference effects on double cracks in both collinear and offset conditions were conducted. The variation rule of the stress intensity factor(SIF) influence factor, RK, of double collinear cracks changing with crack spacing ratio, RS, was researched. The horizontal and vertical crack spacing threshold of double cracks within the design life of the shiplift were obtained, which are 24 and 4 times as large as half of initial crack length, c0, respectively. The crack growth rates along the length and depth directions in the process of coalescence on double collinear cracks were also studied. 展开更多
关键词 large-module rack double cracks fatigue crack propagation crack spacing threshold moving load
在线阅读 下载PDF
A Scheme of Dynamic Voltage Restorer to Improve Power Quality in Large Scale Industrial Enterprises
3
作者 Shan Shi Jun Xiao +5 位作者 Shu Liu Liming Tu Qin Cao Yu Liang Gaoyan Zhang Chengxiong Mao 《Journal of Power and Energy Engineering》 2016年第2期19-26,共8页
Loads in large scale industrial enterprises are always various and complex, causing insecure power quality. Meanwhile, some sensitive loads or precise instruments demand for high power quality. When voltage flicker or... Loads in large scale industrial enterprises are always various and complex, causing insecure power quality. Meanwhile, some sensitive loads or precise instruments demand for high power quality. When voltage flicker or harmonics occurs, dynamic voltage restorer (DVR) can be used to stabilize the load-side voltage, which is a good manner of improving power quality. The paper explains the load demand in large scale industrial enterprises, analyzes several common voltage compensation scheme of DVR, and comes up with another voltage compensation scheme of DVR applied for double power supply with double load. A Simulink model according to the new scheme is also built in MATLAB/Simulink to test its performance. Simulation results show that the proposed scheme can guarantee the load-side voltage stability, which is an effective scheme for managing power quality. 展开更多
关键词 Power Quality Large Scale Enterprises double Power Supply with double load DVR Compensation Scheme
在线阅读 下载PDF