期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Simulation of double cold cores of the 35°N section in the YellowSea with a wave-tide-circulation coupled model 被引量:7
1
作者 夏长水 乔方利 +2 位作者 张勐宁 杨永增 袁业立 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2004年第3期292-298,共7页
Based on the MASNUM wave-tide-circulation coupled numerical model, the temperature structure along 35°N in the Yellow Sea was simulated and compared with the observations. One of the notable features of the tempe... Based on the MASNUM wave-tide-circulation coupled numerical model, the temperature structure along 35°N in the Yellow Sea was simulated and compared with the observations. One of the notable features of the temperature structure along 35°N section is the double cold cores phenomena during spring and summer. The double cold cores refer to the two cold water centers located near 122°E and 125°E from the depth of 30m to bottom. The formation, maintenance and disappearance of the double cold cores are discussed. At least two reasons make the temperature in the center (near 123°E) of the section higher than that near the west and east shores in winter. One reason is that the water there is deeper than the west and east sides so its heat content is higher. The other is invasion of the warm water brought by the Yellow Sea Warm Current (YSWC) during winter.This temperature pattern of the lower layer (from 30m to bottom) is maintained through spring and summer when the upper layer (0 to 30m) is heated and strong thermocline is formed. Large zonal span of the 35°N section (about 600 km) makes the cold cores have more opportunity to survive. The double cold cores phenomena disappears in early autumn when the west cold core vanishes first with the dropping of the thermocline position. 展开更多
关键词 temperature The Yellow Sea wave-tide-circulation coupled model double cold cores
原文传递
Mechanical performance and texture characteristic of an IF steel containing Nb and Ti by double cold rolling 被引量:4
2
作者 Ling-yun Wang Peng Zhang +1 位作者 Wei Li Guang-jie Huang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2009年第1期51-57,共7页
Single cold rolling and double cold rolling were applied to hot rolled strips with different reduction ratios. The evolutions of { 100}, { 111} and Goss face texture during double rolling were investigated by comparin... Single cold rolling and double cold rolling were applied to hot rolled strips with different reduction ratios. The evolutions of { 100}, { 111} and Goss face texture during double rolling were investigated by comparing the orientation distribution function (ODF) of the double rolled sample with that of the single rolled one. The double cold rolling texture is characterized by a higher γ-texture and a lower α-texture, and the { 111}〈112〉 component is improved remarkably. Based on the TEM observation and mechanical properties test, it is found that the reduction ratio assignment significantly affects the texture variation, as-annealing microstructures, and properties of the double cold rolled samples. These results may provide a theoretical guide for the industrial production of double cold rolled IF steel. 展开更多
关键词 IF steel cold rolling double cold rolling TEXTURE mechanical properties
在线阅读 下载PDF
Structure and Texture Formation During Single and Double Cold Rolling and Annealing Processes for Nb+Ti Added Interstitial-Free Steels
3
作者 FENG Yan-qing WANG Fu-ming +2 位作者 TAO Su-fen ZHAO Dian-qing ZHANG Xiao-yan 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2013年第5期42-49,共8页
The structure and texture formation for single cold rolling (SCR) with annealing and double cold rolling (DCR) with annealing were investigated based on optical microscope and X-ray diffraction (XRD) with a Nb+... The structure and texture formation for single cold rolling (SCR) with annealing and double cold rolling (DCR) with annealing were investigated based on optical microscope and X-ray diffraction (XRD) with a Nb+Ti bearing interstitial free (IF) steel. The results indicated that DCR recrystallization grain was smaller than that of SCR sample and double cold rolling process resulted in better mechanical properties than those resulted from single cold rolling process with the same total reduction conducted. The plastic strain ratio increases from 2.23 for single cold rolling process to 3.2 for double rolling process. The fish-bone structure was observed in all SCR and DCR samples. DCR annealed sample is made up of equiaxed grains of almost uniform size, whereas SCR annealed sample shows a duplex grain structure, consisting of both large and small-sized grains. (Ti+Nb)C and Fe(Ti+Nb)P type precipitates were very rarely observed in SCR annealed and DCR annealed steels. The intensity of {111}∥ND for the DCR annealing was higher than that for SCR annealing. 展开更多
关键词 single cold rolling double cold rolling Nb TI IF steel STRUCTURE texture
原文传递
Design and Engineering Application of Direct Mixing Lubrication System for Emulsion Pipeline in Secondary Cold Rolling Mill
4
作者 Hangzhe DONG Yazhen ZHANG +2 位作者 Wantong HU Zhen-hua BAI Yan-yan ZHANG 《Mechanical Engineering Science》 2020年第1期36-47,共12页
With the benefit fierce competition in the steel industry market in recent years,double cold reduction products have been developed towards strength improvement and thickness reduction.The traditional cold-rolling lub... With the benefit fierce competition in the steel industry market in recent years,double cold reduction products have been developed towards strength improvement and thickness reduction.The traditional cold-rolling lubrication process with a fixed flow rate and concentration cannot solve the problems,which are uncontrollable plate shape and the excessive consumption of lubricating oil.Moreover,based on the analysis of the traditional direct aplication lubrication system of double cold reduction mill,a set of design scheme suitable for the emulsion pipeline direct mixing lubrication system of double cold reduction mill unit was proposed.The design completed the selection of key components,which included the static mixer and atomization nozzle selection,pump and oil pump design selection,pipeline design selection,flow type selection,pressure gauge selection,electronic control cabinet design selection and other eight aspects.Equipment of the emulsion pipeline direct mixing lubrication system of double cold reduction has been developed.Comparing with characteristics of the traditional direct aplication lubrication system,the emulsion pipeline direct mixing lubrication system was better applied to the production practice of a 1220 double cold reduction mill.The consumption of ton of steel was reduced by 9.6%.The rolling energy consumption and fuel consumption comprehensive costs decreased by 10.7%,and the strip steel section thickness difference was reduced by 19.3%.In addition,the plate shape quality defect rate decreased by 25.6%,otherwise creating a large economic benefit for the unit and promoting the application value. 展开更多
关键词 double cold reduction EMULSION direct mixing lubrication system static mixer plate thickness
在线阅读 下载PDF
Statistic characteristics of thermal structure in the southern Yellow Sea in summer 被引量:5
5
作者 白虹 胡敦欣 +1 位作者 陈永利 王庆业 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2004年第3期237-243,共7页
Based on the temperature data along 34°N, 35°N and 36°N sections in August from 1977 to 2003,the structure and formation of the Southern Yellow Sea Cold Water Mass (SYSCWM) and its responses to El Nino ... Based on the temperature data along 34°N, 35°N and 36°N sections in August from 1977 to 2003,the structure and formation of the Southern Yellow Sea Cold Water Mass (SYSCWM) and its responses to El Nino events are analyzed. Results show that: (1) There exist double cold cores under the main thermocline along the 35°N and 36°N sections. Also, double warm cores exist above the main thermocline along the 36°N section.(2) Thermocline dome by upwelling separates the upper warm water into two parts, the eastern and western warm waters. Additionally, the circulation structure caused by upwelling along the cold front and northeastward current along the coast in summer is the main reasons of double warm cores along the 36°N section. The intermediate cold water is formed in early spring and moves eastward slowly, which results in the formation of the western one of double cold cores. (3) Position of the thermocline dome and its intensity vary interannually,which is related to El Nino events. However, the deep cold water temperature is hardly affected by El Nino events. In most El Nino years, position of the thermocline dome shifted eastwards and depth of the dome upper limit decreases. 展开更多
关键词 SYSCWM double warm cores double cold cores thermocline dome intermediate cold water
原文传递
Research on Deformation, Texture and Properties of IF Steel in Multiple Rolling Technology
6
作者 Jinxia LI, Xianghua LIU and Guodong WANGState Key Lab. of Rolling and Automation, Northeastern University, Shenyang 110004, China 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2003年第2期183-184,共2页
The relationships among the deformation, texture and deep drawing properties of IF steel were investigated. By adopting double cold rolling (DCR) technology, the deep drawing property has been developed evidently. Wit... The relationships among the deformation, texture and deep drawing properties of IF steel were investigated. By adopting double cold rolling (DCR) technology, the deep drawing property has been developed evidently. With the aid of orientation distribution function (ODF) analysis, it was found that he main reason for good property is the counterbalance in intensity of the ideal texture component {111} < 011 > and {111} < 112 >. 展开更多
关键词 TEXTURE double cold rolling R-VALUE Deformation.
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部