Water equivalence of some 3D dosimeters:a theoretical study based on the effective atomic number and effective fast neutron removal cross section
1
作者 A.M.El-Khayatt 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第12期170-181,共12页
Effective atomic numbers for photon energy absorption(ZPEA_(eff)) and their corresponding electron numbers (NPEA_(eff)), and effective macroscopic removal cross sections of fast neutrons(RR) were calculated for 27 dif... Effective atomic numbers for photon energy absorption(ZPEA_(eff)) and their corresponding electron numbers (NPEA_(eff)), and effective macroscopic removal cross sections of fast neutrons(RR) were calculated for 27 different types of three-dimensional dosimeters, four types of phantom materials, and water. The values of ZPEA_(eff) and NPEA_(eff) were obtained using the direct method for energies ranging from 10 keV to 20 MeV. Results are presented relative to water, for direct comparison over the range of examined energies. The effect of monomers that are used in polymer gel dosimeters on the water equivalence is discussed. The relation between Σ_R and hydrogen content was studied. Micelle gel dosimeters are highly promising because our results demonstrate perfect matching between the effective atomic number, electron density number, and fast neutron attenuation coefficient of water. 展开更多
关键词 3D dosimeters WATER EQUIVALENCE EFFECTIVE atomic number Photon energy absorption REMOVAL cross section Fast neutrons
暂未订购
Intercomparison of Environmental Gamma doses Measured with A NaI(Tl) Survey Meter and Thermoluminescent Dosimeters(TLDs) in the Poonch Division of Azad Kashmir, Pakistan
2
作者 Muhammad Rafique Kimberlee J Kearfott +6 位作者 Khalil Ahmad Jabeen Akhter Abdul Razzaq Khan Raja Azhar Saeed Saeed Ur Rahman Matiullah Muhammad Usman Rajput 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第12期969-972,共4页
This study presents the intercomparison of the outdoor environmental gamma dose rates measured using a Nal (TI) based survey meter along with thermoluminescent dosimeters (TLDs) and estimation of excess lifetime c... This study presents the intercomparison of the outdoor environmental gamma dose rates measured using a Nal (TI) based survey meter along with thermoluminescent dosimeters (TLDs) and estimation of excess lifetime cancer risk (ELCR), for the inhabitants of Poonch division of the Azad Kashmir, Pakistan. CaF2: Dy (TLD-200) card dosimeters were installed at height of 1 m from ground at fifteen different locations covering the entire Poonch division comprising of three districts. 展开更多
关键词 in the Poonch Division of Azad Kashmir Survey Meter and Thermoluminescent dosimeters TL TLDs NAI
暂未订购
NONLINEAR RESPONSES OF GAMMA-RAY DOSIMETERS
3
作者 罗达玲 杨健明 张纯祥 《Nuclear Science and Techniques》 SCIE CAS CSCD 1994年第1期58-64,共7页
Either sublinear or supralinear responses of dosimeters to y-ray can be described by a response function derived from statistical Poisson distribution.The characteristic parameters of the function determine linearity,... Either sublinear or supralinear responses of dosimeters to y-ray can be described by a response function derived from statistical Poisson distribution.The characteristic parameters of the function determine linearity, sublinearity and supralinearity in their responses. The experimental data of gamma dose-responses of alanine ESR dosimeters,film dosimeters, LiF(Mg, Cu, P) and LiF(Mg, Ti) thermoluminescence dosimeters are used to test the response function. 展开更多
关键词 dosimeters Nonlinear responses y-ray
在线阅读 下载PDF
RESEARCH ON FADING CHARACTERISTICS OF ALANINE/ESR DOSIMETERS IN HIGH DOSE RANGE
4
作者 陈丽姝 H.Tachibana Y.Haruyama 《Nuclear Science and Techniques》 SCIE CAS CSCD 1993年第1期4-10,共7页
The present work has dealt extensively and systematically with the fading characteristics of polystyrene-alanine dosimeters irradiated at different dose rates and total doses under various temperatures (10-70 ℃) and ... The present work has dealt extensively and systematically with the fading characteristics of polystyrene-alanine dosimeters irradiated at different dose rates and total doses under various temperatures (10-70 ℃) and stored a period of time in different conditions (5, 25, room temperature, 40 ℃). Detail investigation on this effect in practical irradiation condition is very important. Because it is difficult to correct this effect using correction coefficients so far. So the temperature coefficients and fading rates have been given along with a lot of experimental data to try to make approximation of radical formation or decay behavior. 展开更多
关键词 Radiation processing dosimetry PS-alanine DOSIMETER ESR Transfer DOSIMETER Temperature coefficients FADING behaviour
在线阅读 下载PDF
Enhanced Sensitivity and Stability in Gelatin-Based Fricke gel Dosimeters:Impact of Benzoic Acid on Low-Dose Radiation Measurements
5
作者 Seyed Amir Saeedi-Sini Sedigheh Sina +1 位作者 Mohammad Hossein Sadeghi Ebrahim Farajzadeh 《Instrumentation》 2024年第3期23-29,共7页
Fricke gel dosimetry is a critical technique for accurate radiation dose measurement, leveraging the radiation-induced oxidation of ferrous to ferric ions within a hydrogel matrix. This study aimed to advance the fiel... Fricke gel dosimetry is a critical technique for accurate radiation dose measurement, leveraging the radiation-induced oxidation of ferrous to ferric ions within a hydrogel matrix. This study aimed to advance the field by preparing and evaluating seventy-one Fricke gel dosimeter(FGD) samples with varying chemical compositions, focusing on the incorporation of benzoic acid. Two gelatin-based samples demonstrated superior sensitivity, particularly for low-dose measurements. Our findings indicated that the sample without benzoic acid exhibited a 1.75 times higher sensitivity compared to the sample containing benzoic acid, with lower limits of detection at 0.04 Gy and 0.1 Gy, respectively. Stability tests revealed temperature-dependent responses, with better performance observed under refrigerated conditions. Reproducibility was confirmed through consistent calibration curves across multiple trials. Additionally, the dosimeters' responses varied with different radiation types, underscoring the need for specific calibrations. The study concludes that while benzoic acid slightly reduces sensitivity, it provides consistent responses across various radiation energies, suggesting its potential as a beneficial additive in diverse clinical scenarios. This research contributes to the ongoing optimization of FGDs for precise radiation dose assessment. 展开更多
关键词 chemical dosimeter freak dosimeter benzoic acid
原文传递
Online measurement of the BEPCⅡ background using RadFET dosimeters
6
作者 宫辉 李金 +3 位作者 龚光华 李裕熊 侯磊 邵贝贝 《Chinese Physics C》 SCIE CAS CSCD 2009年第9期774-776,共3页
To monitor the integral dose deposited in the BESⅢ electromagnetic calorimeter whose performance degrades due to exposure to the BEPC Ⅱ background, a 400 nm IMPL RadFET dosimeter-based integral dose online monitor s... To monitor the integral dose deposited in the BESⅢ electromagnetic calorimeter whose performance degrades due to exposure to the BEPC Ⅱ background, a 400 nm IMPL RadFET dosimeter-based integral dose online monitor system is built, After calibration with the ^60Co source and verification with TLD in the pulse radiation fields, an experiment was arranged to measure the BEPC Ⅱ background online. The results are presented. 展开更多
关键词 BEPC background BESⅢ EMC 400 nm IMPL RadFET dosimeter TLD
原文传递
Health Phys. Abstracts,Volume 128,Number 5
7
《辐射防护》 北大核心 2025年第4期440-444,共5页
Evaluation of a Commercially Available Radiochromic Film for Use as a Complementary Dosimeter for Rapid In-field Low Photon Equivalent Radiation Dose (≤50 mSv) Monitoring Nicky Nivi1, Helen Moise1,2, Ana Pejovic'... Evaluation of a Commercially Available Radiochromic Film for Use as a Complementary Dosimeter for Rapid In-field Low Photon Equivalent Radiation Dose (≤50 mSv) Monitoring Nicky Nivi1, Helen Moise1,2, Ana Pejovic'-Milic'1(1. Department of Physics, Toronto Metropolitan University, 350 Victoria Street, Toronto, Ontario, M5B 2K3;2. Autonomous and Radiological Technologies Section, Defense Research and Development Canada, PO Box 4000 Stn Main,Medicine Hat, Alberta, T1A 8K6). 展开更多
关键词 low photon equivalent radiation dose autonomous radiological technologies complementary dosimeter DOSIMETER field monitoring radiochromic film
暂未订购
Analysis of occupational noise for the healthy life according to the job characteristics 被引量:1
8
作者 Lim-Kyu Lee Ju-Hyun Kim +1 位作者 Bokyung Kim Junghwan Kim 《Health》 2012年第10期897-903,共7页
Noise is known that the physical risk factors defined as any unwanted sound. It can induce the health problems such as hearing loss or annoyance. The objective of this study was to assess the occupational noise exposu... Noise is known that the physical risk factors defined as any unwanted sound. It can induce the health problems such as hearing loss or annoyance. The objective of this study was to assess the occupational noise exposure of nine groups for twenty peoples according to job characteristics and to compare the noise level by different variables. Personal noise levels were measured for three times using by dosimeters for each participant in Korea. The mean time weighted average noise level (TWA) of total was 73.2 ± 11.5 dBA by American conference of governmental industrial hygienists (ACGIH) standard. Especially, Korean classical music students were highly exposed to 93.2 ± 6.2 dBA but, office workers were 63.2 ± 6.6 dBA. In case of peak sound pressure level (Lpeak), Korean classical music students and firefighters were exposed to the highest level of 151.8 dBC and 145.8 dBC during playing and dispatching, respectively. The analysis of noise level showed that Leq had positive correlations between TWA by ministry of employment and labour (MOEL) (r = 0.98, p < 0.01) and TWA by ACGIH (r = 0.98, p < 0.01). Unlikely other groups, the noise exposure level of the Korean classical music students were exceeded the ACGIH standard. These results suggest that Korean classical music students were exposed high noise level and some solutions are need to reduce the noise exposure level such as using hearing protect device. 展开更多
关键词 OCCUPATIONAL Noise EXPOSURE JOB Characteristics dosimeters Noise LEVEL
暂未订购
Fetal radiation exposure: Is monitoring really needed?
9
作者 Milena Di Leo Paolo Giorgio Arcidiacono 《World Journal of Gastrointestinal Endoscopy》 CAS 2013年第8期366-368,共3页
The effect of fetal radiation during endoscopic retro-grade cholangiopancreatography (ERCP) on pregnant women is a very interesting topic. Smith et al recently estimated the fetal radiation exposure in pregnant women ... The effect of fetal radiation during endoscopic retro-grade cholangiopancreatography (ERCP) on pregnant women is a very interesting topic. Smith et al recently estimated the fetal radiation exposure in pregnant women undergoing ERCPs using thermoluminescent dosimeters (TLDs). The authors concluded that TLDs are unnecessary during ERCP with modified techniques. We believe that an extreme caution is needed in clinical practice before drawing such conclusions when they are not strongly supported by enough experimental evidence. Therefore, we recommend that fetal radiation exposure be monitored in clinical practice by using dosimeters, bearing in mind that all relevant techniques to control and minimize the exposure must be applied. 展开更多
关键词 ENDOSCOPIC RETROGRADE cholangiopancrea-tography Pregnancy FETAL radiation exposure Ther-moluminescent dosimeters Post-endoscopic RETROGRADE cholangio-pancreatography PANCREATITIS
暂未订购
IMPROVEMENT IN PREPARATION OF LiF TLD AND OPTIMIZATION OF MEASUREMENT PARAMETERS
10
作者 张建 郭勇 +3 位作者 王兴功 杨甲祥 朱云平 李成林 《Nuclear Science and Techniques》 SCIE CAS CSCD 1994年第3期170-173,共4页
The technological process for prepaxation of LiF TLD is reported. Sixteen types of TLD of LiF:Mg,Ti and LiF:Mg,Cu,P series are produced for dosimetry of X, γradiations and in neutron-γmixed radiation field. The meas... The technological process for prepaxation of LiF TLD is reported. Sixteen types of TLD of LiF:Mg,Ti and LiF:Mg,Cu,P series are produced for dosimetry of X, γradiations and in neutron-γmixed radiation field. The measurement parameters have been optimizationally selected by factors of parameter evaluation (P) and orthogonal method, and the procedure of quality control is recommended. 展开更多
关键词 Thermoluminescent dosimeters LiF X-radiation Gamma radiation Quality assurance
在线阅读 下载PDF
Sm-doped CsBr crystal as a new radio-photoluminescence (RPL) material 被引量:4
11
作者 Go Okada Yutaka Fujimoto +2 位作者 Hironori Tanaka Safa Kasap Takayuki Yanagida 《Journal of Rare Earths》 SCIE EI CAS CSCD 2016年第8期769-773,共5页
Radio-photoluminescence (RPL) is a phenomenon seen in luminescent materials in which the appearance of new photolu- minescence (PL) emission is induced by an incident ionizing radiation such as X-rays; and the sig... Radio-photoluminescence (RPL) is a phenomenon seen in luminescent materials in which the appearance of new photolu- minescence (PL) emission is induced by an incident ionizing radiation such as X-rays; and the signal is stable even after the irradia- tion and during the PL measurement. Since the induced PL intensity is proportional to the irradiation dose, the RPL can be used in ra- diation measurements. The distinct advantage of RPL over the conventional thermally- or photo-stimulated luminescence (abbrevi- ated as TSL or PSL) dosimeters is the stability of response signal. With an RPL detector, it allows us to readout the signal multiple time without signal fading. In this work, we discovered that CsBr:Sm showed an RPL phenomenon by X-ray irradiation, and we characterized this new material as an RPL detector. While the sample showed PL emissions mainly in the visible range, after an X-ray irradiation additional emissions could be observed in the red to near-infrared range around 650-850 nm and 900-1000 nm and longer. The RPL response was fairly stable overall, but very interestingly the 650-850 nm signal slightly increased while the 900-1000 nm decreased during PL readout. The dynamic range was confirmed over 1-104 mGy with linear response. 展开更多
关键词 radio-photoluminescence RPL CsBr Sm DOSIMETER X-rays rare earths
原文传递
The study on optically stimulated luminescence dosimeter based on the SrS:Eu,Sm and CaS:Eu,Sm 被引量:3
12
作者 刘艳平 陈朝阳 +5 位作者 范艳伟 巴维真 郭旗 陆妩 汤新强 杜彦召 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第8期3156-3162,共7页
With the increasing use of nuclear energy, there is a need for a wider range of efficient dosimeters for radiation detection and assessment. There has been a tremendous growth in the development of radiation detectors... With the increasing use of nuclear energy, there is a need for a wider range of efficient dosimeters for radiation detection and assessment. There has been a tremendous growth in the development of radiation detectors and devices in the past few decades. In recent years, the development of new materials for radiation dosimetry has progressed significantly. Alkaline earth sulfides (AES) have been known for a long time as excellent and versatile phosphor materials. In the present investigation, a number of phosphor samples such as mono-, binary and ternary sulfides of alkaline earths (II^a-VI^b) have been prepared and their TL properties have been studied with respect to exposure (x-ray) response and fading. In this paper, some results on SrS:Eu, Sm and CaS:Eu, Sm phosphors are presented. A type of novel OSL dosimeter is described. The dosimeter takes advantage of the characteristics of charge trapping materials SrS:Eu, Sm and CaS:Eu, Sm that exhibit optically stimulated luminescence (OSL). The measuring range of the dosimeter is from 0.01 to 1000 Gy. The OSL dosimeters provide capability for remote monitoring radiation locations which are difficult to access and hazardous. This equipment is relatively simple, small in size and has low power consumption. The device is suitable for space radiation dose exploration. In addition, it also can be used in IC and other radiation occasions and has good prospects. 展开更多
关键词 optically stimulated luminescence RADIATION DOSIMETER
原文传递
Performance of a plastic scintillation fiber dosimeter based on different photoelectric devices 被引量:3
13
作者 Yue Yang Cui-Ping Yang +6 位作者 Jie Xin Hai-Feng Chen Zhong-Xu Xing Wei-Wei Qu Liang Hu Xin-Jian Chen Ren-Sheng Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第11期25-31,共7页
The photoelectric device of a scintillation dosimeter converts photons produced by radiation into an electrical signal.Its features directly determine the overall performance of the dosimeter.For a plastic scintillati... The photoelectric device of a scintillation dosimeter converts photons produced by radiation into an electrical signal.Its features directly determine the overall performance of the dosimeter.For a plastic scintillation fiber dosimeter(PSFD)with a current readout mode,systematic studies of the stability and light-dose response were performed for the photomultiplier tube(PMT),silicon photomultiplier(SiPM),avalanche photodiode(APD),and photodiode(PD).The temperature stability,long-term stability,repeatability,signal-to-noise ratio(SNR),and current dose response of the PSFD with the abovementioned photoelectric devices were studied using a pulsed LED light source and the Small Animal Radiation Therapy platform.An exponential relationship between the dark/ne current and temperature was obtained for all the devices.I is shown that the APD is the most sensitive device to temperature,with a current dependence on temperature reaching 6.5%C^(-1)at room temperature,whereas for the other devices this dependence is always<0:6%C^(-1).In terms of long-term stability,the net current of PD can change by up to 4%when working continuously for 8 h and 2%when working intermittently for 32 h,whereas for the other devices,the changes are all<1%.For the dose response,the PMT and SiPM exhibit excellent linear responses and SNRs within the range of 0.1-60 Gy/min For the PSFD with a current readout mode,the performance of the PMT and SiPM is concluded to be better than that of the other devices in the study.In particular,the SiPM,which has a compact size,low bias voltage,and antimagnetic interference,has great advantages for further applications. 展开更多
关键词 Photoelectric device Plastic scintillation fiber dosimeter(PSFD) Current readout Dose response
在线阅读 下载PDF
ALPHA THERMOLUMINESCENCE DOSIMETRY IN DATING OF POTTERY 被引量:2
14
作者 王维达 夏君定 《Nuclear Science and Techniques》 SCIE CAS CSCD 1994年第2期79-86,共8页
This article describes the measurement of internal alpha dose-rate in pottery using ultrathin CaSO4: Tin thermoluminescence dosimeter. Among the advantages ofthe techllique are not only convenience, accuracy, lowcost,... This article describes the measurement of internal alpha dose-rate in pottery using ultrathin CaSO4: Tin thermoluminescence dosimeter. Among the advantages ofthe techllique are not only convenience, accuracy, lowcost, but also the beta dose--ratefrom pottery can be obtained at the same time. 展开更多
关键词 POTTERY Thermoluminescence dating Annual alpha dose Ultrathinthermoluminescence dosimeter
在线阅读 下载PDF
Photon energy response optimization using few-channel spectroscopy dose method for Si-PIN photodetector applied in personal dose equivalent measurements 被引量:1
15
作者 Ping Huang Shu-Qiong Li +3 位作者 Run-Dong Yang Yun-Tian Sun Yong Yang Wu Gao 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第4期37-46,共10页
Si-PIN photodetectors having features such as low cost,small size,low weight,low voltage,and low power consumption are widely used as radiation detectors in electronic personal dosimeters(EPDs).The technical parameter... Si-PIN photodetectors having features such as low cost,small size,low weight,low voltage,and low power consumption are widely used as radiation detectors in electronic personal dosimeters(EPDs).The technical parameters of EPDs based on the Si-PIN photodetectors include photon energy response(PER),angular response,inherent error,and dose rate linearity.Among them,PER is a key parameter for evaluation of EPD measurement accuracy.At present,owing to the limitations of volume,power consumption,and EPD cost,the PER is usually corrected by a combination of single-channel counting techniques and filtering material methods.However,the above-mentioned methods have problems such as poor PER and low measurement accuracy.To solve such problems,in this study,a 1024-channel spectrometry system using a Si-PIN photodetector was developed and fullspectrum measurement in the reference radiation fields was conducted for radiation protection.The measurement results using the few-channel spectroscopy dose method showed that the PER could be controlled within±14%and±2%under the conditions of two and three energy intervals,respectively,with different channel numbers.The PER measured at 0°angle of radiation incidence meets the-29%to+67%requirements of IEC 61526:2010.Meanwhile,the channel number and counts-to-dose conversion factors formed in the experiment can be integrated into an EPD. 展开更多
关键词 Electronic PERSONAL dosimeter Si-PIN PHOTODETECTOR PERSONAL DOSE equivalent Photon energy response Few-channel SPECTROSCOPY DOSE method
在线阅读 下载PDF
Peripheral dose measurement in high-energy photon radiotherapy with the implementation of MOSFET 被引量:1
16
作者 Vassiliki Vlachopoulou Georgia Malatara +3 位作者 Harry Delis Kiki Theodorou Dimitrios Kardamakis George Panayiotakis 《World Journal of Radiology》 CAS 2010年第11期434-439,共6页
AIM:To study the peripheral dose(PD) from highenergy photon beams in radiotherapy using the metal oxide semiconductor field effect transistor(MOSFET) dose verification system.METHODS:The radiation dose absorbed by the... AIM:To study the peripheral dose(PD) from highenergy photon beams in radiotherapy using the metal oxide semiconductor field effect transistor(MOSFET) dose verification system.METHODS:The radiation dose absorbed by the MOSFET detector was calculated taking into account the manufacturer's Correction Factor,the Calibration Factor and the threshold voltage shift.PD measurements were carried out for three different field sizes(5 cm×5 cm,10 cm×10 cm and 15 cm×15 cm) and for various depths with the source to surface distance set at 100 cm.Dose measurements were realized on the central axis and then at distances(1 to 18 cm) parallel to the edge of the field,and were expressed as the percentage PD(% PD) with respect to the maximum dose(dmax).The accuracy of the results was evaluated with respect to a calibrated 0.3 cm3 ionization chamber.The reproducibility was expressed in terms of standard deviation(s) and coefficient of variation.RESULTS:% PD is higher near the phantom surface and drops to a minimum at the depth of dmax,and then tends to become constant with depth.Internal scatter radiation is the predominant source of PD and the depth dependence is determined by the attenuation of the primary photons.Closer to the field edge,where internal scatter from the phantom dominates,the % PD increases with depth because the ratio of the scatter to primary increases with depth.A few centimeters away from the field,where collimator scatter and leakage dominate,the % PD decreases with depth,due to attenuation by the water.The % PD decreases almost exponentially with the increase of distance from the field edge.The decrease of the % PD is more than 60% and can reach up to 90% as the measurement point departs from the edge of the field.For a given distance,the % PD is significantly higher for larger field sizes,due to the increase of the scattering volume.Finally,the measured PD obtained with MOSFET is higher than that obtained with an ionization chamber with percentage differences being from 0.6% to 34.0%.However,when normalized to the central dmax this difference is less than 1%.The MOSFET system,in the early stage of its life,has a dose measurement reproducibility of within 1.8%,2.7%,8.9% and 13.6% for 22.8,11.3,3.5 and 1.3 cGy dose assessments,respectively.In the late stage of MOSFET life the corresponding values change to 1.5%,4.8%,11.1% and 29.9% for 21.8,2.9,1.6 and 1.0 cGy,respectively.CONCLUSION: Comparative results acquired with the MOSFET and with an ionization chamber show fair agreement, supporting the suitability of this measurement for clinical in vivo dosimetry. 展开更多
关键词 RADIOTHERAPY PERIPHERAL DOSE Metal OXIDE semiconductor field effect TRANSISTOR DOSIMETER
暂未订购
KCl:Eu^(2+) as a solar UV-C radiation dosimeter. Optically stimulated luminescence and thermoluminescence analyses 被引量:1
17
作者 I.Aguirre de Cárcer H.L.D'Antoni +2 位作者 M.Barboza-Flores V.Correcher F.Jaque 《Journal of Rare Earths》 SCIE EI CAS CSCD 2009年第4期579-583,共5页
The KCI:Eu2+ system response to UV-C was investigated by analyzing the optically stimulated luminescence (OSL) and ther- mo-luminescence (TL) signal produced by ultraviolet light exposure at room temperature. It... The KCI:Eu2+ system response to UV-C was investigated by analyzing the optically stimulated luminescence (OSL) and ther- mo-luminescence (TL) signal produced by ultraviolet light exposure at room temperature. It was found that after UV-C irra.diation, OSL was produced on a wide band of visible wavelengths with decay time that varied by several orders of magnitude depending on the Eu2+ aggregation state. In spite of the low intensity of solar UV-C reaching the Earth's surface in Madrid (40° N, 700 m a.s.1.), it was possible to measure the UV-C radiation dose at 6:48 solar time by using the TL response of the KCI:Eu2+ system and differentiate it from the ambient beta radiation dose. 展开更多
关键词 THERMO-LUMINESCENCE rare-earth-doped alkali halides solar ultraviolet dosimeter environmental radiation
在线阅读 下载PDF
Simulation of gamma minitype reference radiation for calibration of personal dosimeter 被引量:1
18
作者 Yi-Xin Liu Yi-Kun Qian +3 位作者 Zhi-Qiang Chen Biao Wei Peng Feng Ben-Jiang Mao 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第1期112-122,共11页
An investigation using Monte Carlo simulation on a minitype reference radiation(MRR) for the calibration of gamma personal dosimeters is reported. The distributions of dose rate and scattering gamma spectrum are the m... An investigation using Monte Carlo simulation on a minitype reference radiation(MRR) for the calibration of gamma personal dosimeters is reported. The distributions of dose rate and scattering gamma spectrum are the main simulation objects with the variable physical structures of MRR and the dosimeters as parameters that are to be calibrated. Further, the influences on the reference radiation caused by these parameters are analyzed in detail.This work provides a theoretical basis for better understanding of MRR used for calibration of gamma personal dosimeters. This analysis can help in the development of a calibration technology for such tools based on MRR. 展开更多
关键词 Gamma personal dosimeter Minitype reference radiation Monte Carlo simulation CALIBRATION
暂未订购
WDVE—6/100医用电子直线加速器DOSIMETER报警故障一例
19
作者 张秀文 李文立 王功明 《医疗装备》 1999年第11期45-45,共1页
关键词 WDVE-6/100型 医用电子直线加速器 DOSIMETER灯 故障检修 机械计数器
在线阅读 下载PDF
GENERAL PROPERTIES OF DOMESTIC RADIOCHROMIC FILM ELECTRON DOSIMETER
20
作者 陈丽姝 闻友勤 孙存普 《Nuclear Science and Techniques》 SCIE CAS CSCD 1991年第4期193-198,共6页
The project established a system for routine measurement of electron dose and brought about a complete experimental approach for high-dose dosimetry. The paper reports some general properties of domestic radiochromic ... The project established a system for routine measurement of electron dose and brought about a complete experimental approach for high-dose dosimetry. The paper reports some general properties of domestic radiochromic pararosaniline cyanide (PR-CN) dye with polyvinyl butyral (PVB)-based film used for measuring electron dose. The optical absorption spectrum, the change in optical density as a function of thickness, distribution of the background optical density and spread of response, long-term stability, linear relationship between the change in optical density per unit thickness and absorbed dose, the minimum detectable limit, effect of environmental factors on background and response after irradiation, effect of light-exposition and the time of establishing complete response have been experimentally investigated. 展开更多
关键词 ELECTRON DOSIMETER High DOSE DOSIMETRY Film DOSIMETER RADIATION processing