A series of laboratory pull-out tests was conducted to study the effects of temperature on the performance and behaviours of fully grouted rock bolt specimens cured within a specific temperature range,as well as for d...A series of laboratory pull-out tests was conducted to study the effects of temperature on the performance and behaviours of fully grouted rock bolt specimens cured within a specific temperature range,as well as for different durations.Each specimen consisted of a 20M rebar bolt at 1300 mm embedment length grouted inside a Schedule 80 steel pipe using Portland cement grout at a 0.4 water-to-cement ratio.Two temperatures(20℃and 45℃)were explored to investigate the effects of geothermally active temperature conditions on fully grouted rock bolts.Distributed fiber optic sensors were employed to provide continuous strain profiles along the entire embedment length to observe micro-mechanisms and monitor internal specimen temperature change during testing.The specimens cured at 45℃generally resulted in higher grout UCS(in certain cases 25%e50%higher)compared to those at 20℃;the ultimate capacity was not significantly impacted as the specimens'embedment length allowed full development of the rock bolt's capacity.The resulting strain profile trends showed generally higher strains experienced by the shorter(i.e.3-d)curing duration specimens under both curing temperatures compared to long-term curing.The 45℃specimens generally experienced lower strains and faster strain profile attenuation compared to specimens cured at 20℃.Understanding these effects and further analysis of FGRB specimen behaviours over time provide insights for mobilized and critical embedment lengths,capacity development,and support system stabilization.This paper highlights the results of this study and aims to bridge selected gaps in existing literature with a view to aid practitioners.展开更多
The principle of optical time-domain reflection localization limits the sensing spatial resolution of Raman distributed optical fiber sensing.We provide a solution for a Raman distributed optical fiber sensing system ...The principle of optical time-domain reflection localization limits the sensing spatial resolution of Raman distributed optical fiber sensing.We provide a solution for a Raman distributed optical fiber sensing system with kilometer-level sensing distance and submeter spatial resolution.Based on this,we propose a Raman distributed optical fiber sensing scheme based on chaotic pulse cluster demodulation.Chaotic pulse clusters are used as the probe signal,in preference to conventional pulsed or chaotic single-pulse lasers.Furthermore,the accurate positioning of the temperature variety region along the sensing fiber can be realized using chaotic pulse clusters.The proposed demodulation scheme can enhance the signal-to-noise ratio by improving the correlation between the chaotic reference and the chaotic Raman anti-Stokes scattering signals.The experiment achieved a sensing spatial resolution of 30 cm at a distributed temperature-sensing distance of∼6.0 km.Furthermore,we explored the influence of chaotic pulse width and detector bandwidth on the sensing spatial resolution.In addition,the theoretical experiments proved that the sensing spatial resolution in the proposed scheme was independent of the pulse width and sensing distance.展开更多
The integration of distributed optical fiber temperature sensor with supervisory control and data acquisition (SCADA) system is proposed and implemented. In the implementation of the integration, both the compatibil...The integration of distributed optical fiber temperature sensor with supervisory control and data acquisition (SCADA) system is proposed and implemented. In the implementation of the integration, both the compatibility with traditional system and the characteristics of distributed optical fiber temperature sensor is considered before Modbus TCP/IP protocol is chosen. The protocol is implemented with open source component Indy. The Modbus TCP/IP protocol used in the system is proved to be fast and robust.展开更多
Distributed temperature sensing(DTS)using heated cables has been recently developed for distributed monitoring of in-situ soil moisture content.In this method,the thermal and electrical properties of heated cables hav...Distributed temperature sensing(DTS)using heated cables has been recently developed for distributed monitoring of in-situ soil moisture content.In this method,the thermal and electrical properties of heated cables have a significant influence on the measurement accuracy of soil moisture content.In this paper,the performances of two heated cables,i.e.the carbon-fiber heated cable(CFHC)and the metalnet heated cable(MNHC),are studied in the laboratory.Their structures,uniformity in the axial direction,measurement accuracy and suitability are evaluated.The test results indicate that the MNHC has a better uniformity in the axial direction than CFHC.Both CFHC and MNHC have high measurement accuracy.The CFHC is more suitable for short-distance measurement(500 m),while the MNHC can be used for longdistance measurement(>500 m).展开更多
An optical fiber sensor for strain and temperature measurement based on long period fiber grating(LPFG) cascaded with fiber Bragg grating(FBG) structure has been proposed and realized both theoretically and experiment...An optical fiber sensor for strain and temperature measurement based on long period fiber grating(LPFG) cascaded with fiber Bragg grating(FBG) structure has been proposed and realized both theoretically and experimentally. Theoretical analysis shows that two microstructures with similar sensitivities cannot be used for double parameters measurement. The LPFG is micromachined by the CO_2 laser, and the FBG is micromachined by the excimer laser. For the validation and comparison, two FBGs and one LPFG are cascaded with three transmission valleys, namely FBG1 valley at 1 536.3 nm, LPFG valley at 1 551.2 nm, and FBG2 valley at 1 577.3 nm. The temperature and strain characteristics of the proposed sensor are measured at 45—70 °C and 250—500 με, respectively. The sensitivity matrix is determined by analyzing wavelength shifts and parameter response characterization of three different dips. The proposed optical fiber sensor based on LPFG cascaded with FBG structure can be efficiently used for double parameters measurement with promising application prospect and great research reference value.展开更多
A temperature and acoustic impedance simultaneous sensor based on forward stimulated Brillouin scattering(FSBS)in highly nonlinear fiber(HNLF)with high sensitivity and high accuracy is proposed and demonstrated in thi...A temperature and acoustic impedance simultaneous sensor based on forward stimulated Brillouin scattering(FSBS)in highly nonlinear fiber(HNLF)with high sensitivity and high accuracy is proposed and demonstrated in this paper.High-order acoustic modes(HOAMs)are used to achieve individual or simultaneous measurement of the two parameters.Transverse acoustic waves(TAWs)involved in the FSBS process can efficiently sense the mechanical or environmental changes outside the fiber cladding,which will be reflected in a linear shift of the acoustic resonance frequency.By analyzing the frequencies of specific scattering peaks,the temperature and acoustic impedance outside the fiber cladding can be obtained simultaneously.The highest measured temperature and acoustic impedance sensitivities are 184.93 k Hz/℃and444.56 k Hz/MRayl,and the measurement accuracies are 0.09℃and 0.009 MRayl,respectively,which are both at desirable levels.We believe this work can provide potential application solutions for sensing fields involving temperature or acoustic impedance measurements.展开更多
Moisture content is a fundamental physical index that quantifies soil property and is closely associatedwith the hydrological, ecological and engineering behaviors of soil. To measure in-situ soil moisturecontents, a ...Moisture content is a fundamental physical index that quantifies soil property and is closely associatedwith the hydrological, ecological and engineering behaviors of soil. To measure in-situ soil moisturecontents, a distributed measurement system for in-situ soil moisture content (SM-DTS) is introduced.The system is based on carbon-fiber heated cable (CFHC) technology that has been developed to enhancethe measuring accuracy of in-situ soil moisture content. Using CFHC technique, a temperature characteristicvalue (Tt) can be defined from temperatureetime curves. A relationship among Tt, soil thermalimpedance coefficient and soil moisture content is then established in laboratory. The feasibility of theSM-DTS technology to provide distributed measurements of in-situ soil moisture content is verifiedthrough field tests. The research reported herein indicates that the proposed SM-DTS is capable ofmeasuring in-situ soil moisture content over long distances and large areas.展开更多
The paper made a research on the fiber Bragg grating sensor demodulation system, which was based on virtual instrument labview and it developed a friendly upper monitor software. Based on the LM algorithm, the softwar...The paper made a research on the fiber Bragg grating sensor demodulation system, which was based on virtual instrument labview and it developed a friendly upper monitor software. Based on the LM algorithm, the software realized rapid and accurate spectral data fitting, improving dynamic characteristics and measuring precision of the system. Depending on different fiber Bragg grating sensors, it can realize flexible calibration. It has the functions of collection, display and data storage, which can flexibly design alarm threshold according to the practical application. The fiber Bragg grating sensors can be identified by the software so that the distributed network, with large capacity optical fiber sensing, can be achieved.展开更多
A distributed optical fiber disturbance detection system consisted of a Sagnac interferometer and a Mach-Zehnder interferometer is demonstrated. Two interferometers outputs are connected to an electric band-pass filte...A distributed optical fiber disturbance detection system consisted of a Sagnac interferometer and a Mach-Zehnder interferometer is demonstrated. Two interferometers outputs are connected to an electric band-pass filter via a detector respectively. The central frequencies of the two filters are selected adaptively according to the disturbance frequency. The disturbance frequency is obtained by either frequency spectrum of the two interferometers outputs. An alarm is given out only when the Sagnac interferometer output is changed. A disturbance position is determined by calculating a time difference with a cross-correlation method between the filter output connected to the Sagnac interferometer and derivative of the filter output connected to the Mach-Zehnder interferometer. The frequency spectrum, derivative and cross-correlation are obtained by a signal processing system. Theory analysis and simulation results are presented. They show that the system structure and location method are effective, accurate, and immune to environmental variations.展开更多
A highly sensitive optical fiber temperature sensor based on a section of liquid-filled silica capillary tube(SCT)between single mode fibers is proposed. Two micro-holes are drilled on two sides of SCT directly by usi...A highly sensitive optical fiber temperature sensor based on a section of liquid-filled silica capillary tube(SCT)between single mode fibers is proposed. Two micro-holes are drilled on two sides of SCT directly by using femtosecond laser micromachining, and liquid polymer is filled into the SCT through the micro-holes without any air bubbles and then sealed by using ultra-violet(UV) cure adhesive. The sidewall of the SCT forms a Fabry–Perot resonator, and loss peaks are achieved in the transmission spectrum of the SCT at the resonant wavelength. The resonance condition can be influenced by the refractive index variation of the liquid polymer filled in SCT, which is sensitive to temperature due to its high thermooptical coefficient(-2.98 × 10^-4℃^-1). The experimental result shows that the temperature sensitivity of the proposed fiber structure reaches 5.09 nm/℃ with a perfect linearity of 99.8%. In addition, it exhibits good repeatability and reliability in temperature sensing application.展开更多
A novel system configuration of fiber optic sensor based on optical abso rption is proposed. Several compensation measures are discussed. A simulated exp eriment is designed and the output curve of system is given. Th...A novel system configuration of fiber optic sensor based on optical abso rption is proposed. Several compensation measures are discussed. A simulated exp eriment is designed and the output curve of system is given. The experiment al result shows that these compensation measures are effective on dynamic distu rbances which are caused by background light and optical fiber bend. In addition , the drifts in the light source intensity, fiber losses, and photodetector effi ciency are also compensated.展开更多
The distributed strain sensor has significant application in real time measurement of strain status for large and important engineering structures such as aircraft, bridge and dam. In this paper, a quasi distributed...The distributed strain sensor has significant application in real time measurement of strain status for large and important engineering structures such as aircraft, bridge and dam. In this paper, a quasi distributed optical fiber strain sensor system is set up using optical time domain reflect technique. The local strain sensors based on a novel microbend configuration are designed and applied to measure local strains along the optical fiber. As the result of the experimental research, the microbend sensors show high sensitivity, good linearity and repeatability in certain operation range.展开更多
A novel method to measure the temperature on the surface of micro-hotplate was presented. The tiny fiber probe and the optical power meter were employed to measure the sample radialization power. By means of comparing...A novel method to measure the temperature on the surface of micro-hotplate was presented. The tiny fiber probe and the optical power meter were employed to measure the sample radialization power. By means of comparing the relationship between the radialization power and the temperature, sample surface temperature can be discerned accurately. Such an approach has provided more accuracy than traditional temperature measurements. The experimental result based on this method is quite similar to that of simulation by the finite element analysis (FEA) software of Ansys in theory. This measurement is very useful for measuring temperature for these micro samples prone to be untouchable.展开更多
Based on advantages of technology of distributive fiber-optic temperature sensing and specific to its applications in monitoring mine conflagration, the corresponding Processes such as connection arrangement, signal t...Based on advantages of technology of distributive fiber-optic temperature sensing and specific to its applications in monitoring mine conflagration, the corresponding Processes such as connection arrangement, signal transmission and monitoring were illustrated. As applied in Sitai Coal Mine of Datong Coal Mine Group Co., this method is effective and accurate and could provide reliable gist for monitoring spontaneous combustion in gob area of mines.展开更多
Abstract: A new setup of measuring temperature is developed, which the probe is a micro- power consumptive one with CMOS circuit and is driven by optical power. For transmitting the measured signal and optical power s...Abstract: A new setup of measuring temperature is developed, which the probe is a micro- power consumptive one with CMOS circuit and is driven by optical power. For transmitting the measured signal and optical power signal in a long distance, the fiber technology is applied in this setup.展开更多
Due to the increasing demand of replacing large capacity overhead lines with underground cables in Korea, KEPCO (Korea Electric Power Corporation) and LS Cable (LS Cable & System) have developed 345 kV optical fi...Due to the increasing demand of replacing large capacity overhead lines with underground cables in Korea, KEPCO (Korea Electric Power Corporation) and LS Cable (LS Cable & System) have developed 345 kV optical fiber composite XLPE (cross-linked polyethylene) 2,500 mm2 cable system. This system has been installed in Cheongna district of Incheon city. KEPCO and LS Cable are also planning to build the cooling system in a tunnel in order to reduce the ambient temperature caused by currents. In this paper, the process of development, field installation, and final inspection test of the complete system will be described.展开更多
A landslide monitoring application is presented by using a high-resolution distributed fiber optic stress sensor. The sensor is used to monitor the intra-stress distribution and variations in landslide bodies, and can...A landslide monitoring application is presented by using a high-resolution distributed fiber optic stress sensor. The sensor is used to monitor the intra-stress distribution and variations in landslide bodies, and can be used for the early warning of the occurrence of the landslides. The principle of distributed fiber optic stress sensing and the intra-stress monitoring method for landslides are described in detail. By measuring the distributed polarization mode coupling in the polarization-maintaining fiber, the distributed fiber stress sensor with stress measuring range 0 to 15 MPa, spatial resolution 10 cm and measuring range 0.5 km, is designed. The warning system is also investigated experimentally in the field trial.展开更多
We have numerically and experimentally investigated the flow rate measurement of the pipeline based on the optical fiber.Employing the large eddy simulation(LES)model,we have quantitatively analyzed the pressure fluct...We have numerically and experimentally investigated the flow rate measurement of the pipeline based on the optical fiber.Employing the large eddy simulation(LES)model,we have quantitatively analyzed the pressure fluctuation of the pipe wall caused by the turbulent flow in the pipeline.The simulation results have shown that the standard deviation of pressure fluctuation was quadratic with the flow rate.We have verified the theoretical model by using a distributed optical fiber acoustic sensing(DAS)system in the flow rate range from 0.61 m/s to 2.42 m/s.The experimental results were consistent with the simulation results very well.Furthermore,to improve the measuring error at the low flow rate,we have employed the composite adaptive denoising algorithm to eliminate the background noise and system noise.The final results have shown that the minimum goodness of fit was improved from 0.962 to 0.997,and the variation of the quadratic coefficient significantly decreased by 93.25%.The measured flow rate difference was only 0.84%between different sensing points in repeated experiments.展开更多
为了实现对城市地下综合管廊全域温度精准、高效、低成本的在线监测,解决分布式光纤温度传感(RDTS,raman distributed temperature sensor)面临的信噪比低、空间分辨率有限、小尺度异常不敏感、数据存储成本高及无法二维监测等技术瓶颈...为了实现对城市地下综合管廊全域温度精准、高效、低成本的在线监测,解决分布式光纤温度传感(RDTS,raman distributed temperature sensor)面临的信噪比低、空间分辨率有限、小尺度异常不敏感、数据存储成本高及无法二维监测等技术瓶颈。本文提出一套RDTS性能提升方法:包括采用GraphSAGE图神经网络的信号降噪方法;结合全变差反卷积与全连接神经网络的空间分辨率提升方法;利用注意力机制与K-Means聚类检测的小尺度异常检测方法;通过隐式神经表示的数据压缩方法;最终基于处理后的一维温度信号,通过特殊布线策略的二维温度场构建方法。该套方法能有效提升RDTS在测量精度、异常检测灵敏度和覆盖维度上的性能,为管廊全域温度监测提供了高准确度、小尺度、低成本的解决方案。展开更多
基金funded by the Canadian Department of National Defence(DND),the RMC Green Team Military GeoWorks Lab,and the National Sciences and Engineering Research Council(NSERC)of Canada.
文摘A series of laboratory pull-out tests was conducted to study the effects of temperature on the performance and behaviours of fully grouted rock bolt specimens cured within a specific temperature range,as well as for different durations.Each specimen consisted of a 20M rebar bolt at 1300 mm embedment length grouted inside a Schedule 80 steel pipe using Portland cement grout at a 0.4 water-to-cement ratio.Two temperatures(20℃and 45℃)were explored to investigate the effects of geothermally active temperature conditions on fully grouted rock bolts.Distributed fiber optic sensors were employed to provide continuous strain profiles along the entire embedment length to observe micro-mechanisms and monitor internal specimen temperature change during testing.The specimens cured at 45℃generally resulted in higher grout UCS(in certain cases 25%e50%higher)compared to those at 20℃;the ultimate capacity was not significantly impacted as the specimens'embedment length allowed full development of the rock bolt's capacity.The resulting strain profile trends showed generally higher strains experienced by the shorter(i.e.3-d)curing duration specimens under both curing temperatures compared to long-term curing.The 45℃specimens generally experienced lower strains and faster strain profile attenuation compared to specimens cured at 20℃.Understanding these effects and further analysis of FGRB specimen behaviours over time provide insights for mobilized and critical embedment lengths,capacity development,and support system stabilization.This paper highlights the results of this study and aims to bridge selected gaps in existing literature with a view to aid practitioners.
基金supported by the National Natural Science Foundation of China(Grant Nos.U23A20375 and 62075151)the National Key Research and Development Program of China(Grant No.202103021223042).
文摘The principle of optical time-domain reflection localization limits the sensing spatial resolution of Raman distributed optical fiber sensing.We provide a solution for a Raman distributed optical fiber sensing system with kilometer-level sensing distance and submeter spatial resolution.Based on this,we propose a Raman distributed optical fiber sensing scheme based on chaotic pulse cluster demodulation.Chaotic pulse clusters are used as the probe signal,in preference to conventional pulsed or chaotic single-pulse lasers.Furthermore,the accurate positioning of the temperature variety region along the sensing fiber can be realized using chaotic pulse clusters.The proposed demodulation scheme can enhance the signal-to-noise ratio by improving the correlation between the chaotic reference and the chaotic Raman anti-Stokes scattering signals.The experiment achieved a sensing spatial resolution of 30 cm at a distributed temperature-sensing distance of∼6.0 km.Furthermore,we explored the influence of chaotic pulse width and detector bandwidth on the sensing spatial resolution.In addition,the theoretical experiments proved that the sensing spatial resolution in the proposed scheme was independent of the pulse width and sensing distance.
基金supported by the National Natural Science Foundation of China under Grant No. 60608009Science Foundation of Zhejiang Province under Grant No. Y107091 and ScienceTechnology Department of Zhejiang Province under Grant No. 2008C21172.
文摘The integration of distributed optical fiber temperature sensor with supervisory control and data acquisition (SCADA) system is proposed and implemented. In the implementation of the integration, both the compatibility with traditional system and the characteristics of distributed optical fiber temperature sensor is considered before Modbus TCP/IP protocol is chosen. The protocol is implemented with open source component Indy. The Modbus TCP/IP protocol used in the system is proved to be fast and robust.
基金The financial supports provided by the National Natural Science Foundation of China(Grant Nos.41230636,41372265,41427801)National Basic Research Program of China(973 Project)(Grant No.2011CB710605)
文摘Distributed temperature sensing(DTS)using heated cables has been recently developed for distributed monitoring of in-situ soil moisture content.In this method,the thermal and electrical properties of heated cables have a significant influence on the measurement accuracy of soil moisture content.In this paper,the performances of two heated cables,i.e.the carbon-fiber heated cable(CFHC)and the metalnet heated cable(MNHC),are studied in the laboratory.Their structures,uniformity in the axial direction,measurement accuracy and suitability are evaluated.The test results indicate that the MNHC has a better uniformity in the axial direction than CFHC.Both CFHC and MNHC have high measurement accuracy.The CFHC is more suitable for short-distance measurement(500 m),while the MNHC can be used for longdistance measurement(>500 m).
基金supported by the Program for Changjiang Scholars and Innovative Research Team in University(No.IRT_16R07)the Project Plan of Beijing Municipal Education Commission for Enhancing the Innovation Capability in 2015(No.TJSHG201510772016)the Open Project of Beijing Engineering Research Center of Optoelectronic Information and Instruments(No.GD2016008)
文摘An optical fiber sensor for strain and temperature measurement based on long period fiber grating(LPFG) cascaded with fiber Bragg grating(FBG) structure has been proposed and realized both theoretically and experimentally. Theoretical analysis shows that two microstructures with similar sensitivities cannot be used for double parameters measurement. The LPFG is micromachined by the CO_2 laser, and the FBG is micromachined by the excimer laser. For the validation and comparison, two FBGs and one LPFG are cascaded with three transmission valleys, namely FBG1 valley at 1 536.3 nm, LPFG valley at 1 551.2 nm, and FBG2 valley at 1 577.3 nm. The temperature and strain characteristics of the proposed sensor are measured at 45—70 °C and 250—500 με, respectively. The sensitivity matrix is determined by analyzing wavelength shifts and parameter response characterization of three different dips. The proposed optical fiber sensor based on LPFG cascaded with FBG structure can be efficiently used for double parameters measurement with promising application prospect and great research reference value.
文摘A temperature and acoustic impedance simultaneous sensor based on forward stimulated Brillouin scattering(FSBS)in highly nonlinear fiber(HNLF)with high sensitivity and high accuracy is proposed and demonstrated in this paper.High-order acoustic modes(HOAMs)are used to achieve individual or simultaneous measurement of the two parameters.Transverse acoustic waves(TAWs)involved in the FSBS process can efficiently sense the mechanical or environmental changes outside the fiber cladding,which will be reflected in a linear shift of the acoustic resonance frequency.By analyzing the frequencies of specific scattering peaks,the temperature and acoustic impedance outside the fiber cladding can be obtained simultaneously.The highest measured temperature and acoustic impedance sensitivities are 184.93 k Hz/℃and444.56 k Hz/MRayl,and the measurement accuracies are 0.09℃and 0.009 MRayl,respectively,which are both at desirable levels.We believe this work can provide potential application solutions for sensing fields involving temperature or acoustic impedance measurements.
基金The financial supports provided by the National Natural Science Foundation of China(Grant Nos.41230636,41372265,41427801)National Basic Research Program of China(973 Project)(Grant No.2011CB710605)
文摘Moisture content is a fundamental physical index that quantifies soil property and is closely associatedwith the hydrological, ecological and engineering behaviors of soil. To measure in-situ soil moisturecontents, a distributed measurement system for in-situ soil moisture content (SM-DTS) is introduced.The system is based on carbon-fiber heated cable (CFHC) technology that has been developed to enhancethe measuring accuracy of in-situ soil moisture content. Using CFHC technique, a temperature characteristicvalue (Tt) can be defined from temperatureetime curves. A relationship among Tt, soil thermalimpedance coefficient and soil moisture content is then established in laboratory. The feasibility of theSM-DTS technology to provide distributed measurements of in-situ soil moisture content is verifiedthrough field tests. The research reported herein indicates that the proposed SM-DTS is capable ofmeasuring in-situ soil moisture content over long distances and large areas.
文摘The paper made a research on the fiber Bragg grating sensor demodulation system, which was based on virtual instrument labview and it developed a friendly upper monitor software. Based on the LM algorithm, the software realized rapid and accurate spectral data fitting, improving dynamic characteristics and measuring precision of the system. Depending on different fiber Bragg grating sensors, it can realize flexible calibration. It has the functions of collection, display and data storage, which can flexibly design alarm threshold according to the practical application. The fiber Bragg grating sensors can be identified by the software so that the distributed network, with large capacity optical fiber sensing, can be achieved.
基金Project supported by the Innovation Program of Education Commission of Shanghai Municipality (Grant No.10YZ19)the Shanghai Leading Academic Discipline Project (Grant No.S30108)the Shanghai Key Laboratory of Specialty Fiber Optics and Optical Access Networks (Grant No.SKLSFO200903)
文摘A distributed optical fiber disturbance detection system consisted of a Sagnac interferometer and a Mach-Zehnder interferometer is demonstrated. Two interferometers outputs are connected to an electric band-pass filter via a detector respectively. The central frequencies of the two filters are selected adaptively according to the disturbance frequency. The disturbance frequency is obtained by either frequency spectrum of the two interferometers outputs. An alarm is given out only when the Sagnac interferometer output is changed. A disturbance position is determined by calculating a time difference with a cross-correlation method between the filter output connected to the Sagnac interferometer and derivative of the filter output connected to the Mach-Zehnder interferometer. The frequency spectrum, derivative and cross-correlation are obtained by a signal processing system. Theory analysis and simulation results are presented. They show that the system structure and location method are effective, accurate, and immune to environmental variations.
基金Project supported by the Scientific Research Project of Institutions of Higher Learning in Inner Mongolia Autonomous Region,China(Grant No.NJZY19214)
文摘A highly sensitive optical fiber temperature sensor based on a section of liquid-filled silica capillary tube(SCT)between single mode fibers is proposed. Two micro-holes are drilled on two sides of SCT directly by using femtosecond laser micromachining, and liquid polymer is filled into the SCT through the micro-holes without any air bubbles and then sealed by using ultra-violet(UV) cure adhesive. The sidewall of the SCT forms a Fabry–Perot resonator, and loss peaks are achieved in the transmission spectrum of the SCT at the resonant wavelength. The resonance condition can be influenced by the refractive index variation of the liquid polymer filled in SCT, which is sensitive to temperature due to its high thermooptical coefficient(-2.98 × 10^-4℃^-1). The experimental result shows that the temperature sensitivity of the proposed fiber structure reaches 5.09 nm/℃ with a perfect linearity of 99.8%. In addition, it exhibits good repeatability and reliability in temperature sensing application.
文摘A novel system configuration of fiber optic sensor based on optical abso rption is proposed. Several compensation measures are discussed. A simulated exp eriment is designed and the output curve of system is given. The experiment al result shows that these compensation measures are effective on dynamic distu rbances which are caused by background light and optical fiber bend. In addition , the drifts in the light source intensity, fiber losses, and photodetector effi ciency are also compensated.
文摘The distributed strain sensor has significant application in real time measurement of strain status for large and important engineering structures such as aircraft, bridge and dam. In this paper, a quasi distributed optical fiber strain sensor system is set up using optical time domain reflect technique. The local strain sensors based on a novel microbend configuration are designed and applied to measure local strains along the optical fiber. As the result of the experimental research, the microbend sensors show high sensitivity, good linearity and repeatability in certain operation range.
基金Project (60104006) supported by the National Natural Science Foundation of China Project(20030322) supported by the Science Technology Office of Jilin Province
文摘A novel method to measure the temperature on the surface of micro-hotplate was presented. The tiny fiber probe and the optical power meter were employed to measure the sample radialization power. By means of comparing the relationship between the radialization power and the temperature, sample surface temperature can be discerned accurately. Such an approach has provided more accuracy than traditional temperature measurements. The experimental result based on this method is quite similar to that of simulation by the finite element analysis (FEA) software of Ansys in theory. This measurement is very useful for measuring temperature for these micro samples prone to be untouchable.
基金Supported by the National Natural Science Foundation of China (50375026,50375028)
文摘Based on advantages of technology of distributive fiber-optic temperature sensing and specific to its applications in monitoring mine conflagration, the corresponding Processes such as connection arrangement, signal transmission and monitoring were illustrated. As applied in Sitai Coal Mine of Datong Coal Mine Group Co., this method is effective and accurate and could provide reliable gist for monitoring spontaneous combustion in gob area of mines.
文摘Abstract: A new setup of measuring temperature is developed, which the probe is a micro- power consumptive one with CMOS circuit and is driven by optical power. For transmitting the measured signal and optical power signal in a long distance, the fiber technology is applied in this setup.
文摘Due to the increasing demand of replacing large capacity overhead lines with underground cables in Korea, KEPCO (Korea Electric Power Corporation) and LS Cable (LS Cable & System) have developed 345 kV optical fiber composite XLPE (cross-linked polyethylene) 2,500 mm2 cable system. This system has been installed in Cheongna district of Incheon city. KEPCO and LS Cable are also planning to build the cooling system in a tunnel in order to reduce the ambient temperature caused by currents. In this paper, the process of development, field installation, and final inspection test of the complete system will be described.
基金supported by the National Natural Science Foundation of China under Grant No. 60377021partially supported by Program for New Century Excellent Talents in University under Grant. No. NCET-07-0152Sichuan Scientific Funds for Young Researchers under Grant No. 08ZQ026-012.
文摘A landslide monitoring application is presented by using a high-resolution distributed fiber optic stress sensor. The sensor is used to monitor the intra-stress distribution and variations in landslide bodies, and can be used for the early warning of the occurrence of the landslides. The principle of distributed fiber optic stress sensing and the intra-stress monitoring method for landslides are described in detail. By measuring the distributed polarization mode coupling in the polarization-maintaining fiber, the distributed fiber stress sensor with stress measuring range 0 to 15 MPa, spatial resolution 10 cm and measuring range 0.5 km, is designed. The warning system is also investigated experimentally in the field trial.
基金supported in part by the National Natural Science Foundation of China(Grant No.U22A20206)the Key Research and Development Plan Project of Hubei Province,China(Grant No.2022BAA004)Zhejiang Provincial Market Supervision Bureau Young Eagle Plan Project,China(Grant No.CY2022228).
文摘We have numerically and experimentally investigated the flow rate measurement of the pipeline based on the optical fiber.Employing the large eddy simulation(LES)model,we have quantitatively analyzed the pressure fluctuation of the pipe wall caused by the turbulent flow in the pipeline.The simulation results have shown that the standard deviation of pressure fluctuation was quadratic with the flow rate.We have verified the theoretical model by using a distributed optical fiber acoustic sensing(DAS)system in the flow rate range from 0.61 m/s to 2.42 m/s.The experimental results were consistent with the simulation results very well.Furthermore,to improve the measuring error at the low flow rate,we have employed the composite adaptive denoising algorithm to eliminate the background noise and system noise.The final results have shown that the minimum goodness of fit was improved from 0.962 to 0.997,and the variation of the quadratic coefficient significantly decreased by 93.25%.The measured flow rate difference was only 0.84%between different sensing points in repeated experiments.
文摘为了实现对城市地下综合管廊全域温度精准、高效、低成本的在线监测,解决分布式光纤温度传感(RDTS,raman distributed temperature sensor)面临的信噪比低、空间分辨率有限、小尺度异常不敏感、数据存储成本高及无法二维监测等技术瓶颈。本文提出一套RDTS性能提升方法:包括采用GraphSAGE图神经网络的信号降噪方法;结合全变差反卷积与全连接神经网络的空间分辨率提升方法;利用注意力机制与K-Means聚类检测的小尺度异常检测方法;通过隐式神经表示的数据压缩方法;最终基于处理后的一维温度信号,通过特殊布线策略的二维温度场构建方法。该套方法能有效提升RDTS在测量精度、异常检测灵敏度和覆盖维度上的性能,为管廊全域温度监测提供了高准确度、小尺度、低成本的解决方案。