期刊文献+
共找到537篇文章
< 1 2 27 >
每页显示 20 50 100
Dispersive liquid-liquid microextraction combined with capillary electrophoresis for simultaneous determination of five fluoroquinolone antibiotics in marine crude drugs,seawater,and seafood samples
1
作者 Yingying LOU Guangli ZHAO +6 位作者 Jingyi YAN Dani SUN Jinmao YOU Huiquan XIAO Huitao LIU Guisheng LI Jinhua LI 《Journal of Oceanology and Limnology》 2026年第1期137-149,共13页
To simultaneously enrich,separate,and determine five fluoroquinolone antibiotics(FQs)in marine crude drugs(MCDs),seawater and seafood,we conducted this study using vortex assisted dispersed liquid-liquid microextracti... To simultaneously enrich,separate,and determine five fluoroquinolone antibiotics(FQs)in marine crude drugs(MCDs),seawater and seafood,we conducted this study using vortex assisted dispersed liquid-liquid microextraction(DLLME),followed by capillary electrophoresis(CE)-UV.A single-variable optimization was employed to examine the factors influencing the separation effect of CE and the extraction efficiency of DLLME,including buffer solution,organic solvent,separation voltage,extractant,dispersant,and sample solution pH.Under the optimal conditions,the baseline separation of the five FQs was achieved within 6 min.The analytical performance of the method was assessed using six types of actual samples,including three MCDs of hippocampus,clam,and kelp,seawater,and two seafood of prawn and pomfret,demonstrating good linearity ranging from 0.1-5 or 0.01-5μg/mL.The limits of detection(LODs)and limits of quantification(LOQs)for the five FQs in MCDs were 0.0022-0.0292 and 0.0066-0.0973μg/mL,respectively.The LODs and LOQs in seawater and seafood were 0.0009-0.0262 and 0.0029-0.0874μg/mL,respectively.The matrix effects of this method were evaluated in the hippocampus,seawater,and prawn,and the results show that DLLME could effectively eliminate matrix interference.Satisfactory recovery rates were achieved in all the six tested actual samples.This developed DLLME-CE method was proven simple to operate,accurate and reliable,with high sensitivity,making it suitable for the analysis of multiple antibiotic residues in complex matrices. 展开更多
关键词 fluoroquinolone antibiotic(FQ) dispersive liquid-liquid microextraction(DLLME) capillary electrophoresis(CE) marine crude drug(MCD) SEAFOOD seawater
在线阅读 下载PDF
Novel method for the determination of five carbamate pesticides in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography 被引量:10
2
作者 Zhi Mei Liu Xiao Huan Zang Wei Hua Liu Chun Wang Zhi Wang 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第2期213-216,共4页
A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) ... A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-diode array detector (HPLC-DAD). Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results. Under the optimum conditions for the method, the calibration curve was linear in the concentration range from 5 to 1000 ng mL^-1 for all the five carbamate pesticides, with the correlation coefficients (r^2) varying from 0.9984 to 0.9994. Good enrichment factors were achieved ranging from 80 to 177- fold, depending on the compound. The limits of detection (LODs) (S/N = 3) were ranged from 0.1 to 0.5 ng mL^-1. The method has been successfully applied to the analysis of the pesticide residues in environmental water samples. 展开更多
关键词 Carbamate pesticides High performance liquid chromatography Diode array detection dispersive liquid-liquid microextraction Water samples
在线阅读 下载PDF
Ionic liquid based dispersive liquid-liquid microextraction of aromatic amines in water samples 被引量:13
3
作者 Yun Chang Fan Zheng Liang Hu +2 位作者 Mei Lan Chen Chao Shen Tu Yan Zhu 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第8期985-987,共3页
In this work, a new microextraction method termed ionic liquid based dispersive liquid-liquid microextraction (IL-DLLME) was demonstrated for the extraction of 2-methylaniline, 4-chloroaniline, 1-naphthylamine and 4... In this work, a new microextraction method termed ionic liquid based dispersive liquid-liquid microextraction (IL-DLLME) was demonstrated for the extraction of 2-methylaniline, 4-chloroaniline, 1-naphthylamine and 4-aminobiphenyl in aqueous matrices. After extraction the ionic liquid (IL) phase was injected directly into the high performance liquid chromatography (HPLC) system for determination. Some parameters that might affect the extraction efficiency were optimized. Under the optimum conditions, good linear relationship, sensitivity and reproducibility were obtained. The limits of detection (LOD, S/N = 3) for the four analytes were in the range of 0.45-2.6 μg L^-1. The relative standard deviations (R.S.D., n = 6) were in the range of 6.2-9.8%. This method was applied for the analysis of the real water samples. The recoveries ranged from 93.4 to 106.4%. The main advantages of the method are high speed, high recovery, good repeatability and volatile organic solvent-free. 展开更多
关键词 Ionic liquid (IL) dispersive liquid-liquid microextraction (DLLME) High performance liquid chromatography (HPLC) Aromatic amines
在线阅读 下载PDF
Dispersive liquid-liquid microextraction,an effective tool for the determination of synthetic cannabinoids in oral fluid by liquid chromatography-tandem mass spectrometry 被引量:5
4
作者 Pierpaolo Tomai Alessandra Gentili +3 位作者 Roberta Curini Rossella Gottardo Franco Tagliaro Salvatore Fanali 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2021年第3期292-298,共7页
In the present work,dispersive liquid-liquid microextraction(DLLME)was used to extract six synthetic cannabinoids(JWH-018,JWH-019,JWH-073,JWH-200,or WIN 55,225,JWH-250,and AM-694)from oral fluids.A rapid baseline sepa... In the present work,dispersive liquid-liquid microextraction(DLLME)was used to extract six synthetic cannabinoids(JWH-018,JWH-019,JWH-073,JWH-200,or WIN 55,225,JWH-250,and AM-694)from oral fluids.A rapid baseline separation of the analytes was achieved on a bidentate octadecyl silica hydride phase(Cogent Bidentate C18;4.6 mm×250 mm,4μm)maintained at 37℃,by eluting in isocratic conditions(water:acetonitrile(25:75,V/V)).Detection was performed using positive electrospray ionization-tandem mass spectrometry.The parameters affecting DLLME(pH and ionic strength of the aqueous phase,type and volume of the extractant and dispersive solvent,vortex and centrifugation time)were optimized for maximizing yields.In particular,using 0.5 mL of oral fluid,acetonitrile(1 mL),was identified as the best option,both as a solvent to precipitate proteins and as a dispersing solvent in the DLLME procedure.To select an extraction solvent,a low transition temperature mixture(LTTM;composed of sesamol and chlorine chloride with a molar ratio of 1:3)and dichloromethane were compared;the latter(100μL)was proved to be a better extractant,with recoveries ranging from 73%to 101%by vortexing for 2 min.The method was validated according to the guidelines of Food and Drug Administration bioanalytical methods:intra-day and inter-day precisions ranged between 4%and 18%depending on the spike level and analyte;limits of detection spanned from 2 to 18 ng/mL;matrixmatched calibration curves were characterized by determination coefficients greater than 0.9914.Finally,the extraction procedure was compared with previous methods and with innovative techniques,presenting superior reliability,rapidity,simplicity,inexpensiveness,and efficiency. 展开更多
关键词 microextraction techniques dispersive liquid-liquid microextraction Illicit drugs Synthetic cannabinoids Silica C-based column
暂未订购
A novel method for the determination of trace copper in cereals by dispersive liquid-liquid microextraction based on solidification of floating organic drop coupled with flame atomic absorption spectrometry 被引量:5
5
作者 Chun Xia Wu Qiu Hua Wu Chun Wang Zhi Wang 《Chinese Chemical Letters》 SCIE CAS CSCD 2011年第4期473-476,共4页
A novel,simple,rapid,efficient and environment-friendly method for the determination of trace copper in cereal samples was developed by using dispersive liquid-liquid microextraction based on solidification of floatin... A novel,simple,rapid,efficient and environment-friendly method for the determination of trace copper in cereal samples was developed by using dispersive liquid-liquid microextraction based on solidification of floating organic drop(DLLME-SFO) followed by flame atomic absorption spectrometry.In the DLLME-SFO,copper was complexed with 8-hydroxy quinoline and extracted into a small volume of 1-dodecanol,which is of low density,low toxicity and proper melting point near room temperature. The experimental parameters affecting the extraction efficiency were investigated and optimized.Under the optimum conditions, the calibration graph exhibited linearity over the range of 0.5—500 ng/mL with the correlation coefficient(r) of 0.9996.The enrichment factor was 122 and the limit of detection was 0.1 ng/mL.The method was applied to the determination of copper in the complex matrix samples such as rice and millet with the recoveries for the spiked samples at 5.0 and 10.0 u,g/g falling in the range of 92.0-98.0%and the relative standard deviation of 3.9-5.7%. 展开更多
关键词 dispersive liquid-liquid microextraction based on solidification of floating organic droplet Flame atomic absorption spectrometry Copper Cereal samples
原文传递
Dispersive Liquid-liquid Microextraction Combined with High-performance Liquid Chromatography for the Determination of Clozapine and Chlorpromazine in Urine 被引量:3
6
作者 陈静 熊朝梅 +1 位作者 阮金兰 苏邹 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2011年第2期277-284,共8页
A simple method has been proposed for the determination of clozapine (CLZ) and chlorpromazine (CPZ) in human urine by dispersive liquid-liquid microextraction (DLLME) in combination with high-performance liquid ... A simple method has been proposed for the determination of clozapine (CLZ) and chlorpromazine (CPZ) in human urine by dispersive liquid-liquid microextraction (DLLME) in combination with high-performance liquid chromatography-ultraviolet detector (HPLC-UV). All important variables influencing the extraction efficiency, such as pH, types of the extraction solvent and the disperser solvent and their volume, ionic strength and centrifugation time were investigated and optimized. Under the optimal conditions, the limit of detection (LODs) and quantification (LOQs) of the method were 13 and 39 ng/mL for CLZ, and 2 and 6 ng/mL for CPZ, respectively. The relative standard deviations (RSDs) of the targets were less than 5.1% (C=0.100 μg/mL, n=9). Good linear behaviors over the tested concentration ranges were obtained with the values of R20.999 for the targets. The absolute extraction efficiencies of CLZ and CPZ from the spiked blank urine samples were 98.3% and 97.8%, respectively. The applicability of the technique was validated by analyzing urine samples and the mean recoveries for spiked urine samples ranged from 93.3% to 105.0%. The method was successfully applied for the determination of CLZ and CPZ in real human urine. 展开更多
关键词 dispersive liquid-liquid microextraction CLOZAPINE CHLORPROMAZINE high-performance liquid chromatography human urine
暂未订购
Determination of Amitraz in the Honey Samples by Dispersive Liquid-Liquid Microextraction Followed by Gas Chromatography—Flame Ionization Detection 被引量:4
7
作者 Mostafa Bashiri-Juybari Ali Mehdinia +1 位作者 Ali Jabbari Yadollah Yamini 《American Journal of Analytical Chemistry》 2011年第5期632-637,共6页
Dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography–flame ionization detection (GC-FID), as a simple, rapid and efficient method, was developed for the determination of amitraz in honey sa... Dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography–flame ionization detection (GC-FID), as a simple, rapid and efficient method, was developed for the determination of amitraz in honey samples. This method involves the use of an appropriate mixture of the extraction and disperser solvents for the formation of a cloudy solution in 5.0 mL aqueous sample containing amitraz. After extraction, phase separation was performed by centrifugation and the concentrated amitraz in the sedimented phase was determined by gas chromatography—flame ionization detection (GC-FID). Some important parameters such as the type and volume of extraction and disperser solvents, and the effect of pH and salt on the extraction recovery of amitraz were investigated. Under the optimum conditions (13 μL of carbon tetrachloride as an extraction solvent, 1 mL of acetonitrile as a disperser solvent, no salt addition and pH 6) preconcentration factor and the extraction recovery were 955 and 95.5%, respectively. The linear range was 0.01 - 1.0 mg?kg–1 and the limit of detection was 0.0015 mg?kg–1. The relative standard deviation (RSD, n = 4) for 0.1 mg?kg–1 of amitraz was 3.2%. The recoveries of amitraz from honey samples at the spiking levels of 0.1 mg?kg-1 were 78.8 and 98.2%. The results indicated that DLLME is an efficient technique for the extraction of amitraz in honey samples. 展开更多
关键词 dispersIVE Liquid–Liquid microextraction AMITRAZ HONEY Sample
在线阅读 下载PDF
Utilization of Dispersive Liquid-Liquid Microextraction Coupled with HPLC-UV as a Sensitive and Efficient Method for the Extraction and Determination of Oleanolic Acid and Ursolic Acid in Chinese Medicinal Herbs 被引量:2
8
作者 Yaomei Hao Xuan Chen +2 位作者 Shuang Hu Xiaohong Bai Deshuang Gu 《American Journal of Analytical Chemistry》 2012年第10期675-682,共8页
Isomeric triterpenic acids of oleanolic acid (OA) and ursolic acid (UA) both have very low ultraviolet absorption and always exist in the same plant, so the separation and simultaneous determination of them have been ... Isomeric triterpenic acids of oleanolic acid (OA) and ursolic acid (UA) both have very low ultraviolet absorption and always exist in the same plant, so the separation and simultaneous determination of them have been a difficult task. In this study, a sensitive method combining dispersive liquid-liquid microextraction (DLLME) with HPLC-UV was developed for the extraction and determination of OA and UA in traditional Chinese medicinal herbs (CMHs). Variables influencing DLLME such as type and volume of extraction solvent, volume of dispersive solvent, ionic strength, aqueous phase pH, extraction time, centrifugation speed and time, and sample volume were investigated and optimized. Under the optimum conditions, both OA and UA attained favorable extraction efficiencies with enrichment factors 1378 and 933, respectively. The linear dynamic ranges of 0.07 - 30.4 μg?mL–1 for OA and 0.08 - 33.6 μg?mL–1 for UA were obtained with square correlation coefficients of 0.9963. The detection limits of OA and UA were both 0.02 μg?mL–1. The method recoveries ranged between 88.2% - 116.2% for OA and 85.7% - 108.2% for UA with the RSDs (n = 5) lower than 8.6%. The proposed method was successfully applied to concentrate and simultaneously determine these two triterpenic acids in Hedyotis diffusa and Eriobotrya japonica samples. 展开更多
关键词 dispersive liquid-liquid microextraction High Performance Liquid Chromatography Enrichment Factor Triterpenic ACIDS Chinese MEDICINAL HERBS
在线阅读 下载PDF
Determination of Cobalt in Food, Environmental and Water Samples with Preconcentration by Dispersive Liquid-Liquid Microextraction 被引量:1
9
作者 Catalina Bosch Ojeda Fuensanta Sánchez Rojas José Manuel Cano Pavón 《American Journal of Analytical Chemistry》 2012年第2期125-130,共6页
A new method for the determination of cobalt was developed by dispersive liquid-liquid microextraction preconcentra-tion and flame atomic absorption spectrometry. In the proposed approach, 1,5-bis(di-2-pyridyl) methyl... A new method for the determination of cobalt was developed by dispersive liquid-liquid microextraction preconcentra-tion and flame atomic absorption spectrometry. In the proposed approach, 1,5-bis(di-2-pyridyl) methylene thiocarbohydrazide (DPTH) was used as a chelating agent, and chloroform and ethanol were selected as extraction and dispersive solvents. Some factors influencing the extraction efficiency of cobalt and its subsequent determination, including extraction and dispersive solvent type and volume, pH of sample solution, concentration of the chelating agent, and extraction time, were studied and optimized. Under the optimum conditions, a preconcentration factor of 8 was reached. The detection limit for cobalt was 12.4 ng?mL–1, and the relative standard deviation (RSD) was 3.42% (n = 7, c = 100 ng?mL–1). The method was successfully applied to the determination of cobalt in food, environmental and water samples. 展开更多
关键词 COBALT dispersive liquid-liquid microextraction Flame Atomic Absorption Spectrometry Water ENVIRONMENTAL and FOOD Samples
在线阅读 下载PDF
Evaluation of Response Surface Methodology in Dispersive Liquid-Liquid Microextraction for Lead Determination Using Ionic Liquids
10
作者 Behrooz Majidi Farzaneh Shemirani Rouhollah Khani 《American Journal of Analytical Chemistry》 2011年第8期892-901,共10页
This paper describes a dispersive liquid–liquid microextraction (DLLME) procedure using room temperature ionic liquids (RTILs) coupled with flame atomic absorption spectrometry detection with microsample intro-ductio... This paper describes a dispersive liquid–liquid microextraction (DLLME) procedure using room temperature ionic liquids (RTILs) coupled with flame atomic absorption spectrometry detection with microsample intro-duction system capable of quantifying trace amounts of lead. In the proposed approach, ammonium pyr-rolidine dithiocarbamate (APDC) was used as a chelating agent and 1-hexyl-3-methylimmidazolium bis (trifluormethylsulfonyl)imid as an extraction solvent was dissolved in acetone as the disperser solvent. The binary solution was then rapidly injected by a syringe into the water sample containing Pb2+ complex. Some factors influencing the extraction efficiency of Pb2+ and its subsequent determination, including extraction and dispersive solvent type, pH of sample solution, concentration of the chelating agent and salt effect were inspected by a full factorial design to identify important parameters and their interactions. Next, a central composite design was applied to obtain the optimum points of the important parameters. Under the optimum conditions, the limit of detection (LOD) was 0.2 μg/L. The relative standard deviation (R.S.D) was 1.4% for 5 μg/L of Pb2+ (n = 7). The relative recovery of lead in seawater, blood, tomato and black tea samples was measured. 展开更多
关键词 IONIC Liquid dispersIVE liquid-liquid microextraction Microsample INJECTION Experimental Design
在线阅读 下载PDF
Trace determination of hexabromocyclododecane diastereomers in water samples with temperature controlled ionic liquid dispersive liquid phase microextraction 被引量:3
11
作者 Ru Song Zhao Xia Wang Jin Peng Yuan Shan Shan Wang Chuan Ge Cheng 《Chinese Chemical Letters》 SCIE CAS CSCD 2011年第1期97-100,共4页
A novel temperature controlled ionic liquid dispersive liquid phase microextracfion (TCIL-DLPME) coupled with rapid resolution liquid chromatography-electrospray tandem mass spectrometry (RRLC-ESI-MS-MS) has been ... A novel temperature controlled ionic liquid dispersive liquid phase microextracfion (TCIL-DLPME) coupled with rapid resolution liquid chromatography-electrospray tandem mass spectrometry (RRLC-ESI-MS-MS) has been developed for the enrichment and determination of three hexabromocyclododecane diastereomers (HBCDs) in water samples. Green solvent ionic liquid (IL) was used as extraction solvent instead of toxic organic solvents. This technique also avoided the usage of dispersive solvent. Some important parameters that might affect the extraction efficiency were optimized. Under the optimum conditions, good linear relationship, sensitivity and reproducibility were obtained. All the limits of detection for the three diastereomers were 0.1 ng/ mL. The linear range was obtained in the range of 1-100 ng/mL for the total amount of three HBCD diastereomers. It was satisfactory to analyze real environmental water samples with the recoveries ranging from 77.2% to 99.3%. The main advantage of the method is toxic organic solvent-free. 展开更多
关键词 HEXABROMOCYCLODODECANE Temperature controlled ionic liquid dispersive liquid phase microextraction Rapid resolution liquidchromatography-electrospray tandem mass spectrometry
原文传递
Combination of ionic liquid dispersive liquid-phase microextraction and high performance liquid chromatography for the determination of triazine herbicides in water samples 被引量:4
12
作者 Qing-Xiang Zhou Yuan-Yuan Gao 《Chinese Chemical Letters》 SCIE CAS CSCD 2014年第5期745-748,共4页
A temperature-controlled ionic liquid dispersive liquid-phase microextraction in combination with high performance liquid chromatography was developed for the enrichment and determination of triazine herbicides such a... A temperature-controlled ionic liquid dispersive liquid-phase microextraction in combination with high performance liquid chromatography was developed for the enrichment and determination of triazine herbicides such as cyanazine,simazine,and atrazine in water samples.1-Octyl-3-methylimidazolium hexafluorophosphate([C8MIM][PF6]) was selected as the extraction solvent.Several experimental parameters were optimized.Under the optimal conditions,the linear range for cyanazine was in the concentration range of 0.5–80 mg/L and the linear range for simazine and atrazine was in the range of1.0–100 mg/L.The limit of detection(LOD,S/N = 3) was in the ranges of 0.05–0.06 mg/L,and the intra day and inter day precision(RSDs,n = 6) was in the ranges of 3.2%–6.6% and 4.8%–8.9%,respectively.Four real water samples were analyzed with the developed method,and the experimental results showed that the spiked recoveries were satisfactory.All these exhibited that the developed method was a valuable tool for monitoring such pollutants. 展开更多
关键词 Temperature-controlled ionic liquid dispersive liquid-phase microextraction Ionic liquid Triazine herbicides High performance liquid chromatography
原文传递
Dispersive liquid–liquid microextraction of silver nanoparticles in water using ionic liquid1-octyl-3-methylimidazolium hexafluorophosphate 被引量:2
13
作者 Sha Chen Yuanjing Sun +3 位作者 Jingbo Chao Liping Cheng Yun Chen Jingfu Liu 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2016年第3期211-217,共7页
Using the ionic liquid(IL)1-octyl-3-methylimidazolium hexafluorophosphate as the extractant and methanol as the dispersion solvent,a dispersive liquid–liquid microextraction method was developed to extract silver n... Using the ionic liquid(IL)1-octyl-3-methylimidazolium hexafluorophosphate as the extractant and methanol as the dispersion solvent,a dispersive liquid–liquid microextraction method was developed to extract silver nanoparticles(AgN Ps)from environmental water samples.Parameters that influenced the extraction efficiency such as IL concentration,pH and extraction time were optimized.Under the optimized conditions,the highest extraction efficiency for AgN Ps was above 90% with an enrichment factor of 〉90.The extracted AgN Ps in the IL phase were identified by transmission electron microscopy and ultraviolet–visible spectroscopy,and quantified by inductively coupled plasma mass spectrometry after microwave digestion,with a detection limit of 0.01 μg/L.The spiked recovery of AgN Ps was 84.4% with a relative standard deviation(RSD)of 3.8%(n = 6)at a spiked level of 5 μg/L,and 89.7% with a RSD of 2.2%(n = 6)at a spiked level of 300 μg/L,respectively.Commonly existed environmental ions had a very limited influence on the extraction efficiency.The developed method was successfully applied to the analysis of Ag NPs in river water,lake water,and the influent and effluent of a wastewater treatment plant,with recoveries in the range of 71.0%–90.9% at spiking levels of 0.11–4.7 μg/L. 展开更多
关键词 Silver nanoparticle 1-Octyl-3-methylimidazolium hexafluorophosphate Ionic liquid dispersive liquid–liquid microextraction
原文传递
Determination of Vanadyl Porphyrins by Liquid-liquid Microextraction and Nano-baskets of p-tert-Calix[4]arene Bearing Di-[N-(X)sulfonye Carboxamide] and Di-(1-propoxy) in Ortho-cone Conformation
14
作者 MOKHTARI Bahram POURABDOLLAH Kobra 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2012年第5期807-813,共7页
Dispersive liquid-liquid microextraction technique was introducd to remove the centrifuging step and conduct inclusion microextraction of charged porphyrins by nano-baskets. For nano-baskets of p-tert-calix[4]arene be... Dispersive liquid-liquid microextraction technique was introducd to remove the centrifuging step and conduct inclusion microextraction of charged porphyrins by nano-baskets. For nano-baskets of p-tert-calix[4]arene bearing di-[N-(X)sulfonyl carboxamide] and di-(1-propoxy) in ortho-cone conformation was synthesized and used. The related parameters including ligand concentration, the volume of water disperser, salt effect, and extraction time were optimized. The linear range, detection limit(S/N=3) and precision(RSD, n=6) were determined to be 0.2―50, 0.07 μg/L and 5.3%, respectively. The results reveal that the new approach is competitive analytical tool and an alternative of the traditional methods in the crude oil and related systems. 展开更多
关键词 NANO-BASKET dispersive liquid-liquid microextraction Vanadyl porphyrin CALIX[4]ARENE
在线阅读 下载PDF
Eulerian-Lagrangian simulation of dispersed liquid flow in turbulent stirred tanks
15
作者 Jingchang Zhang Xiaoping Guan +1 位作者 Ning Yang Maximilian Lackner 《Chinese Journal of Chemical Engineering》 2025年第7期182-190,共9页
Liquid-liquid dispersion is often performed in stirred tanks,which are valued for their ease of operation,high droplet generation rate and effective droplet dispersion.Many relevant simulations use the Eulerian-Euleri... Liquid-liquid dispersion is often performed in stirred tanks,which are valued for their ease of operation,high droplet generation rate and effective droplet dispersion.Many relevant simulations use the Eulerian-Eulerian method,combining population balance equations with statistical models to forecast droplet breakage.Conversely,the Eulerian-Lagrangian(E-L)method provides precise tracking of individual droplets,which is crucial for simulating dispersion processes.However,E-L simulation faces challenges in integrating droplet breakage effectively.To address this issue,our research introduces a probabilistic approach for droplet breakages.It assumes that a longer time increases the likelihood of breakup;a droplet breaks if the calculated probability exceeds a random value from 0 to 1.Consequently,the simulated breakage frequency becomes independent of the Lagrangian time step.The Sauter mean diameter and droplet size distribution can be accurately predicted by this probabilistic approach.By closely monitoring droplet motion,we reveal the complexity of droplet trajectories and the detailed patterns of circulation in stirred tanks.These insights contribute to a deeper understanding of liquidliquid dispersion dynamics. 展开更多
关键词 Eulerian-Lagrangian method liquid-liquid dispersion Droplet breakage Stirred vessel Turbulent flow Computational fluid dynamics
在线阅读 下载PDF
Liquid-liquid Microextraction Based on Solidification of Floating Organic Drops Coupled with Gas Chromatography for Analyzing Trace Benzene, Toluene and Xylene in Water Samples
16
作者 ZHANG Mao-sheng HUANG Jia-rong +1 位作者 ZHENG Xiang-hua XIE Qiong-fang 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第6期939-943,共5页
A new liquid-liquid microextraction method based on the solidification of floating organic drops coupled with gas chromatography was developed for the determination of trace benzene, toluene and xylene(BTX) in water... A new liquid-liquid microextraction method based on the solidification of floating organic drops coupled with gas chromatography was developed for the determination of trace benzene, toluene and xylene(BTX) in water samples. In the microextraction procedure, a microdrop of n-decanol was delivered to the surface of the analytes’ solution, and stirred for a desired time. Following the absolute extraction, the sample vial was cooled in an ice bath for 10 min. The solidified n-decanol was then transferred into a plastic tube and melted naturally; and 1 μL of it was injected into gas chromatography for analysis. Factors relevant to the extraction efficiency were studied and optimized. The optimal experimental conditions were: 15 μL of n-decanol as extractive solvent, 30 mL of solution containing analytes, no salt, the stirring rate 400 r/min, the extraction temperature 30 °C, and the extraction time 30 min. Under those optimized conditions, the detection limit(LOD) of analytes was in a range of 0.05―0.10 ng/mL by the developed method. A good linearity(r0.99) in a calibration range of 0.01―100 μg/mL was obtained. The recoveries of the real samples at different spiked levels of BTX were in the range from 92.2% to 103.4%. 展开更多
关键词 Gas chromatography liquid-liquid microextraction Solidified floating organic drop n-Decanol
在线阅读 下载PDF
CFD-PBM coupled modeling of the liquid-liquid dispersion characteristics and structure optimization for Kenics static mixer 被引量:2
17
作者 Junhai Deng Shilin Lan +4 位作者 Juchang Wu Shenghua Du Weidong Liu Luchang Han Yefeng Zhou 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第6期173-188,共16页
Kenics static mixers(KSM)are extensively used in industrial mixing-reaction processes by virtue of high mixing efficiency,low power homogenization and easy continuous production.Resolving liquid droplet size and its d... Kenics static mixers(KSM)are extensively used in industrial mixing-reaction processes by virtue of high mixing efficiency,low power homogenization and easy continuous production.Resolving liquid droplet size and its distribution and thus revealing the dispersion characteristics are of great significance for structural optimization and process intensification in the KSM.In this work,a computational fluid dynamics-population balance model(CFD-PBM)coupled method is employed to systematically investigate the effects of operating conditions and structural parameters of KSM on droplet size and its distribution,to further reveal the liquid-liquid dispersion characteristics.Results indicate that higher Reynolds numbers or higher dispersed phase volume fractions increase energy dissipation,reducing Sauter mean diameter(SMD)of dispersed phase droplets and with a shift in droplet size distribution(DSD)towards smaller size.Smaller aspect ratios,greater blade twist and assembly angles amplify shear rate,leading to smaller droplet size and a narrower DSD in the smaller range.The degree of impact exerted by the aspect ratio is notably greater.Notably,mixing elements with different spin enhance shear and stretching efficiency.Compared to the same spin,SMD becomes 3.7-5.8 times smaller in the smaller size range with a significantly narrower distribution.Taking into account the pressure drop and efficiency in a comprehensive manner,optimized structural parameters for the mixing element encompass an aspect ratio of 1-1.5,a blade twist angle of 180°,an assembly angle of 90°,and interlaced assembly of adjacent elements with different spin.This work provides vital theoretical underpinning and future reference for enhancing KSM performance. 展开更多
关键词 CFD Population balance liquid-liquid dispersion Kenics static mixer
在线阅读 下载PDF
Hydrophobic Deep Eutectic Solvent Based Dispersive Liquid-Liquid Microextraction for a Green and Efficient Triclosan Determination:Critical Study of Extraction Variables
18
作者 Carla Toledo-Neira Francisco Garrido-Morales Samuel Piña 《Journal of Analysis and Testing》 2025年第2期279-282,共4页
A rapid and effective analytical method was developed for the detection of triclosan in wastewater samples using a hydrophobic deep eutectic solvent thymol-lidocaine(Thy-Lid,molar ratio of 1:1)and dispersive liquid-li... A rapid and effective analytical method was developed for the detection of triclosan in wastewater samples using a hydrophobic deep eutectic solvent thymol-lidocaine(Thy-Lid,molar ratio of 1:1)and dispersive liquid-liquid microextraction(DLLME).The analyte was determined by high-performance liquid chromatography with a photodiode array detector(HPLC-PDA),obtaining a detection limit of 0.38μg/L,a recovery rate of 99%,and an enrichment factor of the analyte in the water of 80.A factorial design was used to optimize the analytical signal to improve the time and reduce the cost of the method.Combining this chemometric optimization tool with a green solvent and DLLME allows for obtaining an analytical methodology aligned with the principles of green analytical chemistry,enabling the inexpensive,selective,and rapid analysis of triclosan in real wastewater. 展开更多
关键词 detection analytical method factorial design hydrophobic deep eutectic solvent TRICLOSAN photodiode array detector hplc pda obtaining wastewater samples dispersive liquid liquid microextraction
原文传递
超声辅助分散液液微萃取-气相色谱法测定水样中15种硝基苯类化合物
19
作者 周旭平 李双双 董晓健 《化学研究与应用》 北大核心 2026年第1期30-39,共10页
本研究建立了超声辅助分散液液微萃取(UA-DLLME)与双电子捕获检测器(ECD)气相色谱联用技术同时测定环境水体中15种硝基苯类化合物的方法。对色谱柱的选择、萃取溶剂种类及用量、分散剂种类及用量等条件进行了优化。15种硝基苯类化合物在... 本研究建立了超声辅助分散液液微萃取(UA-DLLME)与双电子捕获检测器(ECD)气相色谱联用技术同时测定环境水体中15种硝基苯类化合物的方法。对色谱柱的选择、萃取溶剂种类及用量、分散剂种类及用量等条件进行了优化。15种硝基苯类化合物在0.2~20μg·L^(-1)质量浓度范围内线性良好,线性相关系数为0.9985~0.9998,方法检出限为0.017~0.052μg·L^(-1),空白加标回收率为84.6~98.1%,相对标准偏差为3.3~9.7%。通过对地表水、地下水和污染源废水等实际样品的测定,能够准确定性定量环境水体中硝基苯类化合物浓度水平,地表水、地下水和污染源废水中15种硝基苯类化合物的加标回收率分别为81.0~92.0%、82.0~92.5%和72.7~91.1%,相对标准偏差分别为3.3~10.2%、3.3~10.9%和2.9~9.5%。该方法具有操作简单、环境友好和检出限低等优点,适合于各种环境水体硝基苯类化合物的快速测定。 展开更多
关键词 超声辅助分散液液萃取 硝基苯类化合物 气相色谱
在线阅读 下载PDF
分散液液微萃取法测定党参煎煮液中24种农药残留
20
作者 闫君 王行智 +2 位作者 张菁菁 张婕 吴福祥 《农药科学与管理》 2026年第3期36-43,共8页
建立滤纸过滤,分散液液微萃取结合气相色谱-串联质谱法(GC-MS/MS)测定党参煎煮液中的24种农药残留。以党参煎煮液为基质,考察了党参煎煮液的预处理条件、分散剂和萃取剂的种类和体积、萃取时间及萃取方式对回收率的影响,确定最优萃取条... 建立滤纸过滤,分散液液微萃取结合气相色谱-串联质谱法(GC-MS/MS)测定党参煎煮液中的24种农药残留。以党参煎煮液为基质,考察了党参煎煮液的预处理条件、分散剂和萃取剂的种类和体积、萃取时间及萃取方式对回收率的影响,确定最优萃取条件为滤纸过滤后取20 g的党参煎煮液,加入0.5 mL丙酮和1.0 mL三氯甲烷,1000 r/min提取5 min,3900 r/min离心5 min后取三氯甲烷层上机测定。24种农药在0.5~10μg/kg浓度范围内线性关系良好,相关系数为0.9936~0.9999。检出限和定量限为0.05~0.15μg/kg和0.15~0.50μg/kg,低、中、高3浓度回收率为75.2%~110.5%,相对标准偏差为2.0%~9.5%,24种农药富集倍数为15~22。分散固相萃取净化后基质效应下降明显,滤纸过滤后采用基质匹配标准工作曲线校正也可满足检测需求。对市售20批党参进行农药残留检测,检出农药残留有毒死蜱、氯氟氰菊酯和甲拌磷。该方法操作简便,可为其他中药煎煮液中农残检测提供方法参考。 展开更多
关键词 党参 液液微萃取 气相色谱-串联质谱 煎煮
在线阅读 下载PDF
上一页 1 2 27 下一页 到第
使用帮助 返回顶部