期刊文献+
共找到36篇文章
< 1 2 >
每页显示 20 50 100
蓝光对豚鼠屈光系统发育的影响 被引量:1
1
作者 王宵 栾长霖 +4 位作者 孙一帆 杨诗巧 王凯磊 郝瑞 张伟 《眼科新进展》 CAS 北大核心 2024年第1期18-23,共6页
目的研究蓝光对镜片诱导近视(LIM)豚鼠的眼屈光发育的影响。方法将3周龄的三色豚鼠随机分为3组:对照组、白光LIM组、蓝光LIM组(420 nm LED灯,照度700 lx),后两组豚鼠右眼配戴-10.00 D镜片诱导近视。所有豚鼠均处于12 h光照/12 h黑暗周... 目的研究蓝光对镜片诱导近视(LIM)豚鼠的眼屈光发育的影响。方法将3周龄的三色豚鼠随机分为3组:对照组、白光LIM组、蓝光LIM组(420 nm LED灯,照度700 lx),后两组豚鼠右眼配戴-10.00 D镜片诱导近视。所有豚鼠均处于12 h光照/12 h黑暗周期。在干预前及干预后2周、4周测量所有豚鼠屈光度、眼轴长度、视网膜厚度、脉络膜厚度,干预4周时对豚鼠行角膜荧光染色以及视网膜HE染色。结果与对照组相比,在干预前至干预2周时(0-2周变化量),白光LIM组豚鼠向近视漂移(-2.22±1.28)D,眼轴延长(0.40±0.05)mm,视网膜厚度和脉络膜厚度变薄,分别变化(-7.42±7.04)μm和(-6.29±4.66)μm;与白光LIM组相比,蓝光LIM组豚鼠向远视漂移(0.48±1.16)D,眼轴长度延长(0.20±0.10)mm(均为P<0.05),视网膜增厚(1.36±7.46)μm,脉络膜增厚(8.05±8.08)μm(均为P<0.05)。在干预2周至干预4周时(2-4周变化量),与对照组相比,白光LIM组和蓝光LIM组豚鼠屈光度均向近视发展,分别变化(-4.64±0.50)D和(-2.11±2.02)D(均为P<0.05),白光LIM组豚鼠的眼轴长度延长,视网膜和脉络膜厚度仍变薄,分别变化(0.44±0.06)mm、(-7.35±5.87)μm、(-4.84±2.61)μm;但此时蓝光LIM组豚鼠的脉络膜厚度停止增加并变薄,并且视网膜厚度减少,分别变化(-0.33±5.95)μm、(-4.78±4.96)μm。角膜荧光染色和视网膜HE染色结果表明,长时间蓝光照射可导致角膜和视网膜细胞的损伤。结论蓝光可能通过脉络膜相关机制影响近视的发展,但其抑制效果并不与时间呈单纯的正相关,长期的蓝光照射会损伤角膜和视网膜,从而降低抑制效果。 展开更多
关键词 近视 蓝光 屈光发育 豚鼠
暂未订购
人眼光学模型的研究与发展 被引量:12
2
作者 孔梅梅 高志山 +1 位作者 陈磊 李新华 《激光技术》 CAS CSCD 北大核心 2008年第4期370-373,共4页
以适宜光刺激为主的人眼是人类获取外界信息最多的重要感觉器官。从光学角度而言,人眼是一个有多个界面的复杂光学系统,每一个界面都具有复杂的几何特征和光学特性。结合光学测量,对人眼建立光学模型,研究每个界面的光学特征,在视光学... 以适宜光刺激为主的人眼是人类获取外界信息最多的重要感觉器官。从光学角度而言,人眼是一个有多个界面的复杂光学系统,每一个界面都具有复杂的几何特征和光学特性。结合光学测量,对人眼建立光学模型,研究每个界面的光学特征,在视光学和眼科学领域都有着重要的实际应用意义。通过对国内外模型眼的研究与发展的介绍,总结了各种典型人眼模型的光学结构与特性,并给出了人眼光学模型的研究发展趋势———个性化与精密性。 展开更多
关键词 医用光学与生物技术 眼屈光学 模型眼 综述
暂未订购
人眼角膜曲率参数亚像素测量系统的设计 被引量:5
3
作者 赵俊奇 段培华 +1 位作者 郭智勇 刘海峰 《中北大学学报(自然科学版)》 CAS 北大核心 2011年第3期362-366,共5页
为了提高人眼角膜曲率参数的测量精度,设计了一套角膜测量系统.利用红外光将标准的靶环投影到人眼角膜上,反射后形成带有眼角膜参数特性的虚物,该物再经光学系统成像在CCD图像传感器上.然后通过高速DSP TMS320F2812进行图像二值化处理,... 为了提高人眼角膜曲率参数的测量精度,设计了一套角膜测量系统.利用红外光将标准的靶环投影到人眼角膜上,反射后形成带有眼角膜参数特性的虚物,该物再经光学系统成像在CCD图像传感器上.然后通过高速DSP TMS320F2812进行图像二值化处理,最后采用插值方法计算角膜曲率参数.实验用标准角膜模拟眼进行了测试,结果同日本TPCON KR-8100角膜/验光仪比对,结果表明:计算结果达到亚像素精度,二者测量误差小于国家计量规定的检查最小误差±0.02 mm. 展开更多
关键词 角膜曲率参数测量 插值方法 亚像素测量
暂未订购
非正常眼的模拟与矫正的实验方法研究 被引量:4
4
作者 吕磊 张正厚 +3 位作者 李田勋 苑连美 李凤英 郭顺生 《中国医学物理学杂志》 CSCD 2004年第6期348-350,共3页
本文通过三个薄透镜和像屏组成的共轴球面系统,演示了眼睛成像的光学原理,以及屈光不正的矫正,并比较准确地测定了薄透镜的焦距(光焦度)。
关键词 非正常眼 模拟与矫正 折射系统 光焦度
暂未订购
正视眼人群角膜不同范围的非球面性评价 被引量:11
5
作者 沈媛 李伟力 《眼科新进展》 CAS 2007年第6期443-445,共3页
目的初步探索正视眼人群角膜Q值的分布。方法对来我院健康体检的正视眼192人(384眼)进行裸眼远视力、电脑验光、裂隙灯、直接检眼镜和角膜地形图检测,并对结果进行统计学分析。结果本组人群角膜前表面曲率半径R为(7.80±0.23)mm。Q1... 目的初步探索正视眼人群角膜Q值的分布。方法对来我院健康体检的正视眼192人(384眼)进行裸眼远视力、电脑验光、裂隙灯、直接检眼镜和角膜地形图检测,并对结果进行统计学分析。结果本组人群角膜前表面曲率半径R为(7.80±0.23)mm。Q10值为-0.083±0.098,Q15值为-0.119±0.097,Q20值为-0.149±0.104,Q25值为-0.200±0.107,Q30值为-0.262±0.104;角膜前表面Q值越近中央部越接近0,越靠近周边越向负值增加的方向变化。不同性别角膜不同范围平均Q值无明显差异性(P>0.05)。Q25与Q30在不同年龄组之间差异有显著性(P<0.05),45岁以上组的Q25和Q30值与其他年龄组相比偏大,差别有显著性(P<0.05)。Q30与角膜前表面曲率半径呈负相关(r=-0.115,P<0.05)。各范围Q值均与年龄无明显相关性(P>0.05)。结论正视眼人群角膜前表面中央接近于球形,越到周边越趋于平坦。 展开更多
关键词 Q值 e值/偏心率 非球面性 角膜地形图 角膜 屈光手术
暂未订购
光折射法对牛乳乳糖的快速精确测量 被引量:2
6
作者 靳添博 姬广举 +1 位作者 侯庆春 王晓钰 《哈尔滨理工大学学报》 CAS 2002年第3期32-34,共3页
针对我国乳制品中乳糖质量含量的测量准确度偏低、操作复杂的情况,依据光折射理论,提出了牛乳乳糖质量含量的快速高准确度测量方法.实际测量和定标实验表明,本方法测量牛乳乳糖的质量分数可达到0.1%的准确度.
关键词 快速精确测量 牛乳乳糖 光折射法 定标 乳制品 含糖量 质量分数
在线阅读 下载PDF
基于统一球面投影机理的全景相机标定方法 被引量:2
7
作者 王珂 李瑞峰 赵立军 《华中科技大学学报(自然科学版)》 EI CAS CSCD 北大核心 2013年第S1期99-102,共4页
研究折光鱼眼全景相机的标定方法,采用统一球面映射原理构建相机成像模型;采用FAST算法提取棋盘格标定图像的畸变角点特征.以由粗到精的方式标定全景相机,具体分为两步:用线性矩阵的奇异值分解方法初始估计全景相机的内、外参数;并在此... 研究折光鱼眼全景相机的标定方法,采用统一球面映射原理构建相机成像模型;采用FAST算法提取棋盘格标定图像的畸变角点特征.以由粗到精的方式标定全景相机,具体分为两步:用线性矩阵的奇异值分解方法初始估计全景相机的内、外参数;并在此基础上采用非线性盒约束优化方法实现对内、外参数的精细化估计.实验结果验证了方法的有效性. 展开更多
关键词 机器人视觉 相机标定 统一球面投影模型 折光鱼眼全景视觉 角点提取 盒约束优化
原文传递
光折射法快速测量牛乳乳糖质量分数研究 被引量:3
8
作者 田晓华 常彦琴 +2 位作者 于助 沈涛 姬广举 《黑龙江八一农垦大学学报》 2011年第5期60-63,共4页
针对我国牛乳乳糖质量分数测量存在精度偏低、测量速度慢的情况,依据光折射理论,提出了一种快速精确测量牛乳乳糖质量分数的新方法:光折射法,并构建了稳定可靠的测试系统。理论研究和实际测量结果表明,试样盒的形状对测试结果有重要影响... 针对我国牛乳乳糖质量分数测量存在精度偏低、测量速度慢的情况,依据光折射理论,提出了一种快速精确测量牛乳乳糖质量分数的新方法:光折射法,并构建了稳定可靠的测试系统。理论研究和实际测量结果表明,试样盒的形状对测试结果有重要影响,采用双三角形试样盒,利用光折射法测量牛乳乳糖的质量分数可达到0.1%的精度。 展开更多
关键词 牛乳乳糖 光折射法 定标
在线阅读 下载PDF
Artificial intelligence improves accuracy, efficiency, and reliability of a handheld infrared eccentric autorefractor for adult refractometry 被引量:3
9
作者 Yi-Ting Cao Dan-Yang Che +6 位作者 Yi-Lei Pan Yun-Li Lu Chong-Yang Wang Xiao-Li Zhang Yun-Fei Yang Ke-Ke Zhao Ji-Bo Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第4期628-634,共7页
AIM: To evaluate the accuracy, efficiency, and reliability of a handheld infrared eccentric autorefractor(h ICA) with artificial intelligence(AI) by comparing its refraction measurements to those recorded using h ICA ... AIM: To evaluate the accuracy, efficiency, and reliability of a handheld infrared eccentric autorefractor(h ICA) with artificial intelligence(AI) by comparing its refraction measurements to those recorded using h ICA and a clinical table-mounted automatic refractor(TAR).METHODS: A cross-sectional study using three optometers, including h ICA with or without AI and TAR, for refractometry of adults(aged 19-49 years old) with no signs of ocular disease or trauma in the absence of cycloplegia. Right and left eye refraction data were recorded, including the spherical equivalent(SE), diopter of spherical power(DS), diopter of cylindrical power(DC) decomposed into vectors J0 and J45, and measurement times. To avoid analytical difficulties associated with the interdependence of observations between eyes from the same individual, the Generalized Estimation Equation was used to compare the SE, DS, J0 and J45 measurements, and the times thereof, among the different groups. The intraclass correlation coef f icient(ICC) and Spearman’s rank correlation coefficient were used to evaluate correlations among the measurements recorded by the three different instruments. Bland-Altman were used to analyze the precision of the equipment by the agreement. RESULTS: A total of 70 patients(140 eyes;mean age: 31.37 y;range: 19-49 y) were assessed using refractometry. In a brightly lit environment, there was no significant difference between the mean SE recorded using TAR and that recorded using h ICA with AI or without AI(both P>0.05). In an intense-light environment, h ICA equipped with AI showed a better detection rate than without AI. Light intensity had a greater effect on dioptric measurements recorded using h ICA without AI(P<0.001) than on those recorded using the one equipped with AI(P<0.05). Measurement times varied significantly between the different light intensities and instruments(P<0.05).CONCLUSION: For the normal human eyes, AI may improve the accuracy, efficiency, and reliability of measurements recorded using h ICA in various light environments. 展开更多
关键词 dioptric measurement artificial intelligence equipment design infrared eccentric autorefractor
原文传递
患者年龄与人工晶状体屈光度预测误差的关系 被引量:2
10
作者 李俊逸 许韫 +2 位作者 范彦岩 闫春慧 李斌 《中华眼外伤职业眼病杂志》 2018年第4期273-276,共4页
目的探讨白内障患者年龄与人工晶状体(IOL)屈光度预测误差的关系。方法前瞻性非随机队列研究。对拟行晶状体超声乳化术并植入单片式丙烯酸IOL的连续病例525例(525眼)的资料进行分析。按照年龄进行分组,其中≤59岁组75例(75眼),6... 目的探讨白内障患者年龄与人工晶状体(IOL)屈光度预测误差的关系。方法前瞻性非随机队列研究。对拟行晶状体超声乳化术并植入单片式丙烯酸IOL的连续病例525例(525眼)的资料进行分析。按照年龄进行分组,其中≤59岁组75例(75眼),60~69岁组、70~79岁组和80—89岁组各150例(150眼)。利用优化的SRK/T公式测算所需IOL的屈光度。于术后3个月用自动验光仪进行客观验光。比较各年龄组间平均预测误差和绝对预测误差。结果各年龄组间,SRK/T公式预测的平均术前屈光度的误差差异无统计学意义(P=0.418)。≤59岁年龄组,平均预测误差是-0.24D。60~69岁年龄组为-0.17D,70—79岁年龄组为-0.11D,80~89岁年龄组为-0.11D。各组间平均绝对预测误差差异无统计学意义(P=0.619)。平均预测误差与年龄呈正相关(P=0.000)。多元回归分析显示,在预测误差方面,眼轴长度、平均角膜曲率以及前房深度与年龄差异的预测因子无关。结论年龄每增加10岁,预测误差减少约0.06D的近视。提示在选择人工晶体屈光度时,应该考虑到患者的年龄。 展开更多
关键词 白内障 晶状体超声乳化术 晶状体 人工 预测误差 屈光度
原文传递
基于光折射法的牛乳乳糖测试技术研究 被引量:1
11
作者 田晓华 常彦琴 +2 位作者 沈涛 姬广举 于助 《科技信息》 2011年第5期46-47,共2页
依据光折射原理,建立了利用光折射法测量牛乳乳糖质量含量的理论模型,提出了牛乳乳糖质量含量的快速高准确度测量方法。实验结果表明,本方法能准确、快速的测量牛乳中乳糖质量含量。
关键词 牛乳 乳糖 光折射法
在线阅读 下载PDF
人眼屈光度客觉式测量研究
12
作者 赵剡 朱林泉 +2 位作者 刘增录 赵俊奇 阎洁 《兵工学报》 EI CAS CSCD 北大核心 1997年第1期93-96,共4页
介绍了一种客觉式人眼屈光度测量系统,包括光学设计原理、控制电路组成和数据处理的方法等内容,是国内在这一领域的最新研究成果。利用该系统可以实现人眼的球镜度数、散光度数和散光轴的测量。该系统结构合理,检测精度较好,达到相... 介绍了一种客觉式人眼屈光度测量系统,包括光学设计原理、控制电路组成和数据处理的方法等内容,是国内在这一领域的最新研究成果。利用该系统可以实现人眼的球镜度数、散光度数和散光轴的测量。该系统结构合理,检测精度较好,达到相应的国际水平。 展开更多
关键词 屈光度 散度 散光轴 测量 验光技术
暂未订购
连续Nd:YAG激光器输出功率曲线双峰结构的理论与实验研究
13
作者 徐荣青 常春耘 +1 位作者 兰信钜 陈培锋 《激光杂志》 EI CAS CSCD 北大核心 2000年第6期12-14,共3页
本文分析了内含热透镜平行平凹谐振腔的性质在运行中的变化 ,以屈光度划分了稳区及非稳区 ,并根据稳区分布的对称性及稳腔和非稳腔的性质 ,分析了腔的损耗随泵浦功率的变化关系 ,进而对连续平行平凹腔的Nd :YAG激光器的输出功率特性作... 本文分析了内含热透镜平行平凹谐振腔的性质在运行中的变化 ,以屈光度划分了稳区及非稳区 ,并根据稳区分布的对称性及稳腔和非稳腔的性质 ,分析了腔的损耗随泵浦功率的变化关系 ,进而对连续平行平凹腔的Nd :YAG激光器的输出功率特性作了详细分析。实验观测到了输出功率曲线的双峰结构 ,且测得的实验结果与我们的理论分析相一致。 展开更多
关键词 ND:YAG激光器 双峰结构 输出功率 曲线 实验
在线阅读 下载PDF
老年性白内障屈光状态与矫正视力临床分析 被引量:2
14
作者 陈吉超 陈丹 《实用医技杂志》 2008年第17期2197-2198,共2页
目的:探讨老年性白内障的屈光状态。方法:对159例(294眼)老年性白内障应用自动验光仪、小瞳检影验光,主觉试镜,散瞳后裂隙灯观察晶状体混浊状况,并对矫正前后视力及屈光状态进行比较。结果:老年性白内障患者多有程度不等的屈光改变,白... 目的:探讨老年性白内障的屈光状态。方法:对159例(294眼)老年性白内障应用自动验光仪、小瞳检影验光,主觉试镜,散瞳后裂隙灯观察晶状体混浊状况,并对矫正前后视力及屈光状态进行比较。结果:老年性白内障患者多有程度不等的屈光改变,白内障类型与屈光不正种类有显著关系(P<0.01)。皮质性多为远视及远视散光,核性以近视及近视散光为主,初中期白内障患者矫正视力有明显提高。结论:老年性白内障其晶状体混浊引起的屈光状态是导致初中期白内障患者视力下降的主要原因,早期患者矫正视力可明显提高。 展开更多
关键词 老年性白内障 屈光状态 矫正视力
暂未订购
长焦距宽波段光学系统二级光谱及畸变——波差法参数求解(续)
15
作者 李春霞 付苓 +1 位作者 董慧莲 左保军 《光学技术》 CAS CSCD 1999年第2期30-32,共3页
本文论述了用波差法求解星模拟器上的光学系统各透镜光焦度和曲率半径的方法。为了校正长焦距、宽谱段光学系统二级光谱与畸变,系统的前后组分别在正逆光路下,各自保留约同值反号的位置色差及球差,用波像差法能较准确的解出其解。
关键词 波像差 星模拟器 光学系统 二级光谱 畸变
原文传递
老年性白内障屈光状态临床分析
16
作者 张福民 李波 林呈飞 《中国眼耳鼻喉科杂志》 2005年第4期230-231,共2页
目的探讨老年性白内障类型与其屈光状态关系。方法对102例(204眼)老年性白内障以裂隙灯检查散瞳后晶状体混浊状况,应用自动验光仪对小瞳孔及散瞳眼行电脑验光,并对矫正前后视力及屈光状态进行比较。结果老年性白内障类型与屈光不正种类... 目的探讨老年性白内障类型与其屈光状态关系。方法对102例(204眼)老年性白内障以裂隙灯检查散瞳后晶状体混浊状况,应用自动验光仪对小瞳孔及散瞳眼行电脑验光,并对矫正前后视力及屈光状态进行比较。结果老年性白内障类型与屈光不正种类有着显著的关系(P<0.001),皮质性和混合性多为远视及远视散光,核性以近视及近视散光为主,初中期白内障矫正视力有明显提高。结论老年性白内障其晶状体混浊引起的屈光状态改变是导致初中期白内障患者视力下降的主要原因,早期患者矫正视力可明显提高。 展开更多
关键词 老年性白内障 屈光状态 临床分析 晶状体混浊 矫正视力 裂隙灯检查 自动验光仪 白内障患者 电脑验光 屈光不正 远视散光 近视散光 视力下降 早期患者 小瞳孔 混合性 皮质性 散瞳 中期
暂未订购
B超在视网膜脱离诊断中的应用价值
17
作者 金敏 高宗银 曾绮玲 《广州医药》 2002年第2期53-54,共2页
目的 :探讨B超检查方法对视网膜脱离诊断的应用价值。方法 :通过对 10 4例经手术证实的视网膜脱离B超检查图像分析 ,总结出视网膜脱离的B超特征。结果 :视网脱离的B超图像特征为“—”字形、弧形、V型、Y型、T型、人字型。对屈光间质不... 目的 :探讨B超检查方法对视网膜脱离诊断的应用价值。方法 :通过对 10 4例经手术证实的视网膜脱离B超检查图像分析 ,总结出视网膜脱离的B超特征。结果 :视网脱离的B超图像特征为“—”字形、弧形、V型、Y型、T型、人字型。对屈光间质不清 ,眼底窥不清的视网膜脱离诊断符合率为 94 %。结论 :B超检查对视网膜脱离是一种简便有效、准确的诊断方法 ,对屈光质不清者B超为首选的检查方法。 展开更多
关键词 B超 视网膜脱离 屈光系统 诊断
暂未订购
内含热透镜谐振腔的动态工作特性
18
作者 徐荣青 王建 《华东船舶工业学院学报》 1999年第5期13-16,共4页
分析了内含热透镜平行平凹谐振腔的性质在运行中的变化,按屈光度划分了稳区及非稳区,并根据稳腔和非稳腔的性质,详细分析了连续平行平凹腔Nd :YAG 激光器的输出功率特性。实验中观测到了输出功率曲线的双峰结构。
关键词 钇铝石榴石 激光器 屈光度 双峰结构 热透镜
在线阅读 下载PDF
提高近视眼手术导医质量的方法与体会
19
作者 曾登芬 刘晓红 +1 位作者 李珊 喻红 《南方护理学报》 2002年第5期49-50,共2页
为了提高近视眼手术患者的就医质量,为患者提供良好导医服务,笔者严格执行规章制度和制定导医台的特殊工作规程;确定职责范围;抓好护士素质教育;改进导医台工作模式;从抓细小环节规范服务形象;用心理学观点指导科学导医,培养沉着应战的... 为了提高近视眼手术患者的就医质量,为患者提供良好导医服务,笔者严格执行规章制度和制定导医台的特殊工作规程;确定职责范围;抓好护士素质教育;改进导医台工作模式;从抓细小环节规范服务形象;用心理学观点指导科学导医,培养沉着应战的工作作风;发挥主观能动性和发扬奉献精神,为患者解决实际困难,取得了较高的服务满意率和技术满意率。 展开更多
关键词 近视 屈光手术 导医 质量
暂未订购
透明角膜切口白内障术后角膜曲率的临床观察 被引量:4
20
作者 刘妍 苏胜 +2 位作者 孙红 高宁宁 刘平 《现代生物医学进展》 CAS 2019年第1期95-98,共4页
目的:观察年龄相关性白内障行透明角膜切口超声乳化吸除及人工晶体植入术后角膜曲率的变化及相对稳定的时间。方法:收集2016年6月-8月在哈尔滨医科大学附属第一医院伍连德纪念医院进行的3.0 mm透明角膜切口白内障超声乳化吸除及人工晶... 目的:观察年龄相关性白内障行透明角膜切口超声乳化吸除及人工晶体植入术后角膜曲率的变化及相对稳定的时间。方法:收集2016年6月-8月在哈尔滨医科大学附属第一医院伍连德纪念医院进行的3.0 mm透明角膜切口白内障超声乳化吸除及人工晶体植入术的患者200例216眼,其中男88例、女128例,平均年龄71.2岁,进行相应的术前检查,并检查术前、术后第一天、一周、一个月、和三个月时的角膜曲率、视力、眼压并行相应的统计学分析。结果:术后不同时间点视力>0.5的恢复情况:第一天为147眼(68.05%)、一周为175眼(81.02%)、一个月为193眼(89.35%)、三个月为197眼(91.20%);术前角膜曲率为43.94±1.35、术后第一天、术后一周的角膜曲率分别为44.98±1.06、44.45±1.18,与术前相比有显著性差异(p<0.05),术后一个月、三个月的角膜曲率分别为44.13±1.27、44.02±1.24,与术前相比无显著性差异(p>0.05);术源性散光于术后一天达到最大,随后逐渐减小,术后一个月、三个月与术后一天比较有显著性差异(p<0.05),术后三个月与一个月比较无显著性差异(p>0.05),术源性散光术后逐渐下降,并于一个月时趋于稳定。结论:3.0 mm透明角膜切口白内障超声乳化吸除及人工晶体植入术患者在术后一个月的角膜曲率基本稳定,恢复至术前状态,屈光状态趋于稳定,术源性角膜散光较小,术后视力恢复至较好状态。 展开更多
关键词 白内障 角膜曲率 屈光 散光
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部