To improve the human-physical-virtual coordination and integration of the digital twin workshop,3D visual monitoring and human-computer interaction of the digital twin workshop was studied.First,a novel 6D model of th...To improve the human-physical-virtual coordination and integration of the digital twin workshop,3D visual monitoring and human-computer interaction of the digital twin workshop was studied.First,a novel 6D model of the 3D visualization interactive system for digital twin workshops is proposed.As the traditional 5D digital twin model ignores the importance of human-computer interaction,a new dimension of the user terminal was added.A hierarchical real-time data-driven mapping model for the workshop production process is then proposed.Moreover,a real-time data acquisition method for the industrial Internet of things is proposed based on OPC UA(object linking and embedding for process control unified architecture).Based on the 6D model of the system,the process of creating a 3D visualization virtual environment based on virtual reality is introduced,in addition to a data-driven process based on the data management cloud platform.Finally,the 6D model of the system was confirmed using the blade rotor test workshop as the object,and a 3D visualization interactive system is developed.The results show that the system is more transparent,real-time,data-driven and more efficient,as well as promotes the coordination and integration of human-physical-virtual,which has practical significance for developing digital twin workshops.展开更多
We present an optical encryption method of multiple three-dimensional objects based on multiple interferences and single-pixel digital holography. By modifying the Mach-Zehnder interferometer, the interference of the ...We present an optical encryption method of multiple three-dimensional objects based on multiple interferences and single-pixel digital holography. By modifying the Mach-Zehnder interferometer, the interference of the multiple objects beams and the one reference beam is used to simultaneously encrypt multiple objects into a ciphertext. During decryption, each three-dimensional object can be decrypted independently without having to decrypt other objects. Since the single- pixel digital holography based on compressive sensing theory is introduced, the encrypted data of this method is effectively reduced. In addition, recording fewer encrypted data can greatly reduce the bandwidth of network transmission. Moreover, the compressive sensing essentially serves as a secret key that makes an intruder attack invalid, which means that the system is more secure than the conventional encryption method. Simulation results demonstrate the feasibility of the proposed method and show that the system has good security performance.展开更多
Objective:To evaluate the clinical efficacy of the preoperative digita1 design combined with three dimensional(3D)printing models to assist percutaneous kyphoplasty(PKP)treatment for thoracolumbar compression frac tur...Objective:To evaluate the clinical efficacy of the preoperative digita1 design combined with three dimensional(3D)printing models to assist percutaneous kyphoplasty(PKP)treatment for thoracolumbar compression frac tures.Methods:From January 2018 to August 2020,we obtained data of 99 patients diagnosed thoracolumbar compression fractures.These patients were divided into control group(n=50)underwent traditional PKP surgery,and observation group(n=49)underwent preoperative digital design combined with 3D printing model assisted PKP treatment.The clinical efficacy was evaluated with five parameters,including operation time,number of intraoperative radiographs,visual analogue scale(VAS)score,Cobb Angle change,and high compression rate of injured vertebrae.Results:There were statistically significant differences of operation time and number of intraoperative radio graphs between the two groups(P<0.05).For VAS score,Cobb Angle change and vertebral height compression rate,all of these three parameters were significantly improved when the patients accepted surgery teatment in two groups(P<0.05).However,there were no significant differences between control group and observation group for these three parameters either before or after surgery(P>0.05).Conclusions:Through the design of preoperative surgical guide plate and the application of 3D printing model to guide the operation,the precise design of preoperative surgical puncture site and puncture Angle of the injured vertebra was realized,the number of intraoperative radiographs was reduced,the operation time was shortened and the operation efficiency was improved.展开更多
Aim: Maxillary dental arch widths were evaluated in individuals having unilateral (UCLP) and bilateral (BCLP) cleft lip and palate (CLP) using three-dimensional (3D) digital models. Material and Method: The study had ...Aim: Maxillary dental arch widths were evaluated in individuals having unilateral (UCLP) and bilateral (BCLP) cleft lip and palate (CLP) using three-dimensional (3D) digital models. Material and Method: The study had been conducted on 80 individuals aged between 14 - 17 years having UCLP and BCLP. 40 of the individuals had UCLP, whereas 40 had BCLP. The maxillary dental models taken from patients before the treatment were scanned using Orthomodel Programme (v.1.01, Orthomodel Inc., Istanbul, Turkey) to obtain 3D imagery. Student’s t-test was used in order to assess the data obtained by using SPSS software version 22.0. Results: In BCLP, the average inter-canine distance was 17.44 ± 1.31 mm, the average inter-molar distance was 36.57 ± 1.12 mm, while inter-canine/inter-molar ratio was 0.47. Whereas in UCLP, it was 25.10 ± 0.63 mm, 42.20 ± 0.53 mm and 0.59. The inter-canine distance in UCLP was found to be large enough to be statistically significant (p 0.05), even though there were differences in inter-molar widths. Conclusion: For the stable orthodontic treatment results, one of the most important points is arch form and widths to be coherent with each other. In our study, the increase of inter-canine distance seen in UCLP indicates that in the cleft region, the maxillary arch is inclined over to the back, while the same situation in BCLP suggests that the maxillary segments are collapsed inside. The difference in the arch is highly affected by the primary surgical treatment.展开更多
Objective To discuss the measurement of bone tumor volume on the basis of three dimensional images segmentation technology. Methods Twenty patients with lacunar bone tumor from Tianjin Hospital and Tongji Hospital wer...Objective To discuss the measurement of bone tumor volume on the basis of three dimensional images segmentation technology. Methods Twenty patients with lacunar bone tumor from Tianjin Hospital and Tongji Hospital were included in the展开更多
A series of related electrophysiology phenomena can be caused by the occurrence of interpolated ventricular premature contraction.In our recent three-dimensional Lorenz R-R scatter plot research,we found that atrioven...A series of related electrophysiology phenomena can be caused by the occurrence of interpolated ventricular premature contraction.In our recent three-dimensional Lorenz R-R scatter plot research,we found that atrioventricular node double path caused by interpolated ventricular premature contraction imprints a specifi c pattern on three-dimensional Lorenz plots generated from 24-hour Holter recordings.We found two independent subclusters separated from the interpolated premature beat precluster,the interpolated premature beat cluster,and the interpolated premature beat postcluster,respectively.Combined with use of the trajectory tracking function and the leap phenomenon,our results reveal the presence of the atrioventricular node double conduction path.展开更多
Unlike earlier innovations that focused on manipulation and task precision,the latest surgical advancements emphasize data visualization and the acceleration of surgeons’decision-making.Before entering the operating ...Unlike earlier innovations that focused on manipulation and task precision,the latest surgical advancements emphasize data visualization and the acceleration of surgeons’decision-making.Before entering the operating room,digital tools help surgeons develop patient-specific approaches,outline procedural steps,and prepare strategies for managing potential crises.During the operation,relevant data appear at the right moment to assist decision-making and guide performance in formats tailored to the surgeon’s physical and cognitive state,all without causing distractions.In the future operating room,performance data from surgeons will be gathered,integrated,and analyzed to interpret surgeons’behavior and confidence.Advanced techniques,including artificial intelligence,can be employed to automatically detect moments of performance difficulty or cognitive overload.As a result,digital surgery provides timely,context-specific assistance to surgeons in high-stakes situations.Key components of digital surgery are highlighted in this narrative review.展开更多
It is of great importance to obtain precise trace data,as traces are frequently the sole visible and measurable parameter in most outcrops.The manual recognition and detection of traces on high-resolution three-dimens...It is of great importance to obtain precise trace data,as traces are frequently the sole visible and measurable parameter in most outcrops.The manual recognition and detection of traces on high-resolution three-dimensional(3D)models are relatively straightforward but time-consuming.One potential solution to enhance this process is to use machine learning algorithms to detect the 3D traces.In this study,a unique pixel-wise texture mapper algorithm generates a dense point cloud representation of an outcrop with the precise resolution of the original textured 3D model.A virtual digital image rendering was then employed to capture virtual images of selected regions.This technique helps to overcome limitations caused by the surface morphology of the rock mass,such as restricted access,lighting conditions,and shading effects.After AI-powered trace detection on two-dimensional(2D)images,a 3D data structuring technique was applied to the selected trace pixels.In the 3D data structuring,the trace data were structured through 2D thinning,3D reprojection,clustering,segmentation,and segment linking.Finally,the linked segments were exported as 3D polylines,with each polyline in the output corresponding to a trace.The efficacy of the proposed method was assessed using a 3D model of a real-world case study,which was used to compare the results of artificial intelligence(AI)-aided and human intelligence trace detection.Rosette diagrams,which visualize the distribution of trace orientations,confirmed the high similarity between the automatically and manually generated trace maps.In conclusion,the proposed semi-automatic method was easy to use,fast,and accurate in detecting the dominant jointing system of the rock mass.展开更多
The development of digital twins for geotechnical structures necessitates the real-time updates of threedimensional(3D)virtual models(e.g.numerical finite element method(FEM)model)to accurately predict time-varying ge...The development of digital twins for geotechnical structures necessitates the real-time updates of threedimensional(3D)virtual models(e.g.numerical finite element method(FEM)model)to accurately predict time-varying geotechnical responses(e.g.consolidation settlement)in a 3D spatial domain.However,traditional 3D numerical model updating approaches are computationally prohibitive and therefore difficult to update the 3D responses in real time.To address these challenges,this study proposes a novel machine learning framework called sparse dictionary learning(T-3D-SDL)for real-time updating of time-varying 3D geotechnical responses.In T-3D-SDL,a concerned dataset(e.g.time-varying 3D settlement)is approximated as a linear superposition of dictionary atoms generated from 3D random FEM analyses.Field monitoring data are then used to identify non-trivial atoms and estimate their weights within a Bayesian framework for model updating and prediction.The proposed approach enables the real-time update of temporally varying settlements with a high 3D spatial resolution and quantified uncertainty as field monitoring data evolve.The proposed approach is illustrated using an embankment construction project.The results show that the proposed approach effectively improves settlement predictions along temporal and 3D spatial dimensions,with minimal latency(e.g.within minutes),as monitoring data appear.In addition,the proposed approach requires only a reasonably small number of 3D FEM model evaluations,avoids the use of widely adopted yet often criticized surrogate models,and effectively addresses the limitations(e.g.computational inefficiency)of existing 3D model updating approaches.展开更多
Archaeological excavation involves disintegration, removal, and reassembly of the archaeological record;as such it is considered by many to be an unrepeatable, destructive activity. This perception has contributed to ...Archaeological excavation involves disintegration, removal, and reassembly of the archaeological record;as such it is considered by many to be an unrepeatable, destructive activity. This perception has contributed to an advancement in archaeological practice, namely, the development of computerized recording systems that digitally record archaeological excavations spatially and volumetrically during fieldwork. This paper is concerned with those archaeological sites where digital field recording has not been done. These sites, recorded by traditional methods, should not be excluded from attempts to restructure the spatial, volumetric, and stratigraphic archaeological data. A thorough methodology for the conversion of traditional records into digitized data is presented, including the detailed procedures required for three-dimensional plotting of recorded data—both the excavated material and the drawn site maps and cross-sections. Finally, the use of these methods is demonstrated on a complex Early to Middle Pleistocene site, illustrating the benefits of digitization and three-dimensional reconstruction in resolving stratigraphic and spatial questions.展开更多
The feasibility of three-dimensional (3D) printing technology cgmbined with minimally invasive surgery in the treatment of pubic rami fractures was explored.From August 2015 to October 2017,a series of 30 patients who...The feasibility of three-dimensional (3D) printing technology cgmbined with minimally invasive surgery in the treatment of pubic rami fractures was explored.From August 2015 to October 2017,a series of 30 patients who underwent surgical stabilization of their anterior pelvic ring (all utilizing the 3D printing technology)by one surgeon at a single hospital were studied.The minimally invasive incisions were made through anterior inferior cilia spine and pubic nodule.Data collected included the operative duration,the blood loss,the damage of the important tissue,the biographic union and therecovery of the function after the operation.Measurements on inlet and outlet pelvic cardiograph were made immediately post-operation and at all follow-up clinic visits.The scores of reduction and function were measured during follow-up.Results showed that the wounds of 30 patients were healed in the first stage,and there was no injury of important structures such as blood vessels and nerves.According to the Matta criteria,excellent effectiveness was obtained in 22 cases and good in 8 cases.According to the functional evaluation criteria of Majeed,excellent effectiveness was obtained in 21 cases and good in 9 cases.It was suggested that the 3D printing technology assisted by minimally invasive surgery can better evaluate the pelvic fracture before operation,which was helpful in plate modeling, and can shorten surgery duration and reduce intraoperative blood loss and complications. The positioning accuracy was improved,and better surgical result was finally achieved.展开更多
Objective:This study investigated the effect of proximal contact strength on the three-dimensional displacements of cantilever fixed partial denture(CFPD) under vertically concentrated loading with digital laser speck...Objective:This study investigated the effect of proximal contact strength on the three-dimensional displacements of cantilever fixed partial denture(CFPD) under vertically concentrated loading with digital laser speckle(DLS) technique.Methods:Fresh mandible of beagle dog was used to establish the implant-supported CFPD for specimen.DLS technique was employed for measuring the three-dimensional displacement of the prosthesis under vertically concentrated loading ranging from 200 to 3 000 g.The effect of the contact tightness on the displacement of CFPD was investigated by means of changing the contact tightness.Results:When an axial concentrated loading was exerted on the pontic of the implant-supported CFPD,the displacement of the CFPD was the greatest.The displacement of the prosthesis decreased with the increase of contact strength.When the contact strength was 0,0.95,and 3.25 N,the displacement of the buccolingual direction was smaller than that of the mesiodistal direction but greater than that of the occlusogingival direction.When the force on the contact area was 6.50 N,the mesiodistal displacement of the prosthesis was the biggest while the buccolingual displacement was the smallest.Conclusions:The implant supported CFPD is an effective therapy for fully or partially edentulous patients.The restoration of the contact area and the selection of the appropriate contact strength can reduce the displacement of the CFPD,and get a better stress distribution.The most appropriate force value is 3.25 N in this study.展开更多
Optimal vision and ergonomics are essential factors contributing to the achievement of good results during microsurgery.The three-dimensional(3D)digital image microscope system with a better 3D depth of field can rele...Optimal vision and ergonomics are essential factors contributing to the achievement of good results during microsurgery.The three-dimensional(3D)digital image microscope system with a better 3D depth of field can release strain on the surgeon's neck and back,which can improve outcomes in microsurgery.We report a randomized prospective study of vasoepididymostomy and vasovasostomy using a 3D digital image microscope system(3D-DIM)in rats.A total of 16 adult male rats were randomly divided into two groups of 8 each:the standard operating microscope(SOM)group and the 3D-DIM group.The outcomes measured included the operative time,real-time postoperative mechanical patency,and anastomosis leakage.Furthermore,a user-friendly microscope score was designed to evaluate the ergonomic design and equipment characteristics of the microscope.There were no differences in operative time between the two groups.The real-time postoperative mechanical patency rates were 100.0%for both groups.The percentage of vasoepididymostomy anastomosis leakage was 16.7%in the SOM group and 25.0%in the 3D-DIM group;however,no vasovasostomy anastomosis leakage was found in either group.In terms of the ergonomic design,the 3D-DIM group obtained better scores based on the surgeon's feelings;in terms of the equipment characteristics,the 3D-DIM group had lower scores for clarity and higher scores for flexibility and adaptivity.Based on our randomized prospective study in a rat model,we believe that the 3D-DIM can improve surgeon comfort without compromising outcomes in male infertility reconstructive microsurgery,so the 3D-DIM might be widely used in the future.展开更多
With regard to problems in conventional synthetic aperture radar (SAR), such as imaging distortion, beam limitation and failure in acquiring three-dimensional (3-D) information, a downward-looking 3-D imaging meth...With regard to problems in conventional synthetic aperture radar (SAR), such as imaging distortion, beam limitation and failure in acquiring three-dimensional (3-D) information, a downward-looking 3-D imaging method based on frequency modulated continuous wave (FMCW) and digital beamforming (DBF) technology for airborne SAR is presented in this study. Downward-looking 3-D SAR signal model is established first, followed by introduction of virtual antenna optimization factor and discussion of equivalent-phase-center compensation. Then, compensation method is provided according to reside video phase (RVP) and slope term for FMCW SAR. As multiple receiving antennas are applied to downward-looking 3-D imaging SAR, range cell migration correction (RCMC) turns to be more complex, and corrective measures are proposed. In addition, DBF technology is applied in realizing cross-track resolution. Finally, to validate the proposed method, magnitude of slice, peak sidelobe ratio (PSLR), integrated sidelobe ratio (ISLR) and two-dimensional (2-D) contour plot of impulse response function (IRF) of point target in three dimensions are demonstrated. Satisfactory performances are shown by simulation results.展开更多
Sampling design(SD) plays a crucial role in providing reliable input for digital soil mapping(DSM) and increasing its efficiency.Sampling design, with a predetermined sample size and consideration of budget and spatia...Sampling design(SD) plays a crucial role in providing reliable input for digital soil mapping(DSM) and increasing its efficiency.Sampling design, with a predetermined sample size and consideration of budget and spatial variability, is a selection procedure for identifying a set of sample locations spread over a geographical space or with a good feature space coverage. A good feature space coverage ensures accurate estimation of regression parameters, while spatial coverage contributes to effective spatial interpolation.First, we review several statistical and geometric SDs that mainly optimize the sampling pattern in a geographical space and illustrate the strengths and weaknesses of these SDs by considering spatial coverage, simplicity, accuracy, and efficiency. Furthermore, Latin hypercube sampling, which obtains a full representation of multivariate distribution in geographical space, is described in detail for its development, improvement, and application. In addition, we discuss the fuzzy k-means sampling, response surface sampling, and Kennard-Stone sampling, which optimize sampling patterns in a feature space. We then discuss some practical applications that are mainly addressed by the conditioned Latin hypercube sampling with the flexibility and feasibility of adding multiple optimization criteria. We also discuss different methods of validation, an important stage of DSM, and conclude that an independent dataset selected from the probability sampling is superior for its free model assumptions. For future work, we recommend: 1) exploring SDs with both good spatial coverage and feature space coverage; 2) uncovering the real impacts of an SD on the integral DSM procedure;and 3) testing the feasibility and contribution of SDs in three-dimensional(3 D) DSM with variability for multiple layers.展开更多
Characterizing material 3D deformation and damage is a key challenge in mechanical research. Digital volume correlation (DVC), as a tool for quantifying the internal mechanical response, can comprehensively study th...Characterizing material 3D deformation and damage is a key challenge in mechanical research. Digital volume correlation (DVC), as a tool for quantifying the internal mechanical response, can comprehensively study the extraction of key failure parameters. This review summarizes the recent progresses in the study of the internal movement of granular materials, inhomogeneous deformation of composite materials, and stress intensity factor around a crack front in static and fatigue states using DVC. To elaborate on the technique's potential, we discussed the accuracy and efficiency of the algorithm and the acquisition of real microstructure data within the material under a complex environment.展开更多
In recent years,notable progress has been achieved in both the hardware and algorithms of structured illumination microscopy(SIM).Nevertheless,the advancement of three-dimensional structured illumination microscopy(3D...In recent years,notable progress has been achieved in both the hardware and algorithms of structured illumination microscopy(SIM).Nevertheless,the advancement of three-dimensional structured illumination microscopy(3DSIM)has been impeded by challenges arising from the speed and intricacy of polarization modulation.We introduce a high-speed modulation 3DSIM system,leveraging the polarizationmaintaining and modulation capabilities of a digital micromirror device(DMD)in conjunction with an electrooptic modulator.The DMD-3DSIM system yields a twofold enhancement in both lateral(133 nm)and axial(300 nm)resolution compared to wide-field imaging and can acquire a data set comprising 29 sections of 1024 pixels×1024 pixels,with 15 ms exposure time and 6.75 s per volume.The versatility of the DMD-3DSIM approach was exemplified through the imaging of various specimens,including fluorescent beads,nuclear pores,microtubules,actin filaments,and mitochondria within cells,as well as plant and animal tissues.Notably,polarized 3DSIM elucidated the orientation of actin filaments.Furthermore,the implementation of diverse deconvolution algorithms further enhances 3D resolution.The DMD-based 3DSIM system presents a rapid and reliable methodology for investigating biomedical phenomena,boasting capabilities encompassing 3D superresolution,fast temporal resolution,and polarization imaging.展开更多
Objective: We constructed 3D-model of ONFH in computer according to three-dimensional computerized tomography (3D-CT) data. We determined the location and volume of necrosis to investigate its clinical efficacy. Metho...Objective: We constructed 3D-model of ONFH in computer according to three-dimensional computerized tomography (3D-CT) data. We determined the location and volume of necrosis to investigate its clinical efficacy. Method: Totally 92 hips (59 cases) with ONFH (44 males, 15 females) were included, with mean age of 37.5 years (range from 26 to 58). Totally 20 cases (35 hips) were induced by corticosteroid (CTSs), 31 (49 hips) induced by alcohol, 4 (4 hips) induced by trauma and 4 (4 hips) idiopathic. All the hips were categorized into stage ARCO II. Finally diagnosed by MRI, all hips were scanned by CT to acquire data in DICOM format. The images were imported into software to extract 3D-shape of femoral heads, necrotic foci, their volumes and distribution in each quadrant. Deviation of volumes between digital image and biopsy specimen was analyzed by SAS9.1 package. Correlativity between collapse and volume of necrosis under specific pathogeneses was also analyzed. Among the cases necessitating total hip arthroplasty (THA) due to advancing to ARCO III, we randomly selected 8 of them to perform 3D-CT scanning thrice prior to surgical operation. Total femoral heads harvested were torn asunder. Cubic capacity of femoral heads and necrotic foci were hereby measured and compared with those acquired from digital models. Result: Through the digital model, necrotic foci were found mainly locating within the super lateral portion of femoral head, coinciding with those observed in biopsy specimen. Average volumetric ratio of digitally acquired necrosis focus/femoral head in 58 collapsed hips was 36.8%. The ratio of the 34 hips without collapse was 17.3%. In collapsed femoral heads, the distribution of necrosis focus was 23.4% in quadrant 1 (q1), 23.6% in q2, 12.1% in q3, 14.4% in q4, 9.0% in q5, 11.8% in q6, 1.6% in q7 and 3.9% in q8. In femoral heads without collapse, the distribution was 34.2% in q1, 29.6% in q2, 11.8% in q3, 11.3% in q4, 6.0% in q5, 6.0% in q6, 0.5% in q7 and 0.4% in q8. As for the average cubic capacities of femoral heads and necrotic foci, those acquired from the digital model and biopsy specimen had no significant difference in matched-pairs test (t = -1.49, P = 0.179 for femoral heads and t = -1.52, P = 0.172 for necrotic foci). There was significant difference (F = 2.720, P = 0.035 P was respectively 0.0001 and 0.0005). Decision tree model showed that 94.6% (53/56) hips would progress into collapse if the volumetric ratio of necrotic tissue was over 23.48%. Otherwise, if distribution in q2 was over 45.13%, 83.3% (5/6) hips would progress into collapse. No collapse (0/30) would occur if the distribution of necrotic tissue in q2 was under 45.13%. Conclusion: Digital 3D-model reconstructed from CT scanning can precisely incarnate spatial orientation of necrotic foci in femoral head. Multinomial logistic regression and decision-making tree shows that volumetric ratio of necrotic tissues plays an important role in anticipating collapse of femoral head.展开更多
We compared reconstruction algorithms [filtered back projection (FBP), maximum likelihood expectation maximization (MLEM), and the simultaneous iterative reconstruction technique (SIRT)] in terms of the radiation dose...We compared reconstruction algorithms [filtered back projection (FBP), maximum likelihood expectation maximization (MLEM), and the simultaneous iterative reconstruction technique (SIRT)] in terms of the radiation dose and image quality, for exploring the possibility of decreasing the radiation dose during digital breast tomosynthesis (DBT). The three algorithms were implemented using a DBT system and experimentally evaluated using measurements, such as signal difference-to-noise ratio (SDNR) and intensity profile, on a BR3D phantom (infocus plane image). The possible radiation dose reduction, contrast improvement, and artifact reduction in DBT were evaluated using different exposure levels and the three reconstruction techniques. We performed statistical analysis (one-way analysis of variance) of the SDNR data. The effectiveness of each technique for enhancing the visibility of the BR3D phantom was quantified with regard to SDNR (FBP versus MLEM, P < 0.05;FBP vs. SIRT, P < 0.05;MLEM vs. SIRT, P = 0.945);the artifact reduction was quantified with regard to the intensity profile. MLEM and SIRT produced reconstructed images with SDNR values indicative of low-contrast visibility. The SDNR value for the half-radiation dose MLEM and SIRT images was close to that of the FBP reference radiation dose image. Artifacts were decreased in the MLEM and SIRT images (in the infocus plane) according to the intensity profiles that we obtained. With MLEM and SIRT, the radiation dose may be decreased to half comparison with FBP.展开更多
基金The National Natural Science Foundation of China(No.51875332)the Capacity Building Projects of Some Local Universities of Shanghai Science and Technology Commission(No.18040501600).
文摘To improve the human-physical-virtual coordination and integration of the digital twin workshop,3D visual monitoring and human-computer interaction of the digital twin workshop was studied.First,a novel 6D model of the 3D visualization interactive system for digital twin workshops is proposed.As the traditional 5D digital twin model ignores the importance of human-computer interaction,a new dimension of the user terminal was added.A hierarchical real-time data-driven mapping model for the workshop production process is then proposed.Moreover,a real-time data acquisition method for the industrial Internet of things is proposed based on OPC UA(object linking and embedding for process control unified architecture).Based on the 6D model of the system,the process of creating a 3D visualization virtual environment based on virtual reality is introduced,in addition to a data-driven process based on the data management cloud platform.Finally,the 6D model of the system was confirmed using the blade rotor test workshop as the object,and a 3D visualization interactive system is developed.The results show that the system is more transparent,real-time,data-driven and more efficient,as well as promotes the coordination and integration of human-physical-virtual,which has practical significance for developing digital twin workshops.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61405130 and 61320106015)
文摘We present an optical encryption method of multiple three-dimensional objects based on multiple interferences and single-pixel digital holography. By modifying the Mach-Zehnder interferometer, the interference of the multiple objects beams and the one reference beam is used to simultaneously encrypt multiple objects into a ciphertext. During decryption, each three-dimensional object can be decrypted independently without having to decrypt other objects. Since the single- pixel digital holography based on compressive sensing theory is introduced, the encrypted data of this method is effectively reduced. In addition, recording fewer encrypted data can greatly reduce the bandwidth of network transmission. Moreover, the compressive sensing essentially serves as a secret key that makes an intruder attack invalid, which means that the system is more secure than the conventional encryption method. Simulation results demonstrate the feasibility of the proposed method and show that the system has good security performance.
基金supported in part by the General Program of Natural Science Foundation of Hubei Province,China(Grant No.2020CFB548)a Project in 2021 of Science and Technology Support Plan of Guizhou Province,China(Grant No.202158413293820389).
文摘Objective:To evaluate the clinical efficacy of the preoperative digita1 design combined with three dimensional(3D)printing models to assist percutaneous kyphoplasty(PKP)treatment for thoracolumbar compression frac tures.Methods:From January 2018 to August 2020,we obtained data of 99 patients diagnosed thoracolumbar compression fractures.These patients were divided into control group(n=50)underwent traditional PKP surgery,and observation group(n=49)underwent preoperative digital design combined with 3D printing model assisted PKP treatment.The clinical efficacy was evaluated with five parameters,including operation time,number of intraoperative radiographs,visual analogue scale(VAS)score,Cobb Angle change,and high compression rate of injured vertebrae.Results:There were statistically significant differences of operation time and number of intraoperative radio graphs between the two groups(P<0.05).For VAS score,Cobb Angle change and vertebral height compression rate,all of these three parameters were significantly improved when the patients accepted surgery teatment in two groups(P<0.05).However,there were no significant differences between control group and observation group for these three parameters either before or after surgery(P>0.05).Conclusions:Through the design of preoperative surgical guide plate and the application of 3D printing model to guide the operation,the precise design of preoperative surgical puncture site and puncture Angle of the injured vertebra was realized,the number of intraoperative radiographs was reduced,the operation time was shortened and the operation efficiency was improved.
文摘Aim: Maxillary dental arch widths were evaluated in individuals having unilateral (UCLP) and bilateral (BCLP) cleft lip and palate (CLP) using three-dimensional (3D) digital models. Material and Method: The study had been conducted on 80 individuals aged between 14 - 17 years having UCLP and BCLP. 40 of the individuals had UCLP, whereas 40 had BCLP. The maxillary dental models taken from patients before the treatment were scanned using Orthomodel Programme (v.1.01, Orthomodel Inc., Istanbul, Turkey) to obtain 3D imagery. Student’s t-test was used in order to assess the data obtained by using SPSS software version 22.0. Results: In BCLP, the average inter-canine distance was 17.44 ± 1.31 mm, the average inter-molar distance was 36.57 ± 1.12 mm, while inter-canine/inter-molar ratio was 0.47. Whereas in UCLP, it was 25.10 ± 0.63 mm, 42.20 ± 0.53 mm and 0.59. The inter-canine distance in UCLP was found to be large enough to be statistically significant (p 0.05), even though there were differences in inter-molar widths. Conclusion: For the stable orthodontic treatment results, one of the most important points is arch form and widths to be coherent with each other. In our study, the increase of inter-canine distance seen in UCLP indicates that in the cleft region, the maxillary arch is inclined over to the back, while the same situation in BCLP suggests that the maxillary segments are collapsed inside. The difference in the arch is highly affected by the primary surgical treatment.
文摘Objective To discuss the measurement of bone tumor volume on the basis of three dimensional images segmentation technology. Methods Twenty patients with lacunar bone tumor from Tianjin Hospital and Tongji Hospital were included in the
文摘A series of related electrophysiology phenomena can be caused by the occurrence of interpolated ventricular premature contraction.In our recent three-dimensional Lorenz R-R scatter plot research,we found that atrioventricular node double path caused by interpolated ventricular premature contraction imprints a specifi c pattern on three-dimensional Lorenz plots generated from 24-hour Holter recordings.We found two independent subclusters separated from the interpolated premature beat precluster,the interpolated premature beat cluster,and the interpolated premature beat postcluster,respectively.Combined with use of the trajectory tracking function and the leap phenomenon,our results reveal the presence of the atrioventricular node double conduction path.
文摘Unlike earlier innovations that focused on manipulation and task precision,the latest surgical advancements emphasize data visualization and the acceleration of surgeons’decision-making.Before entering the operating room,digital tools help surgeons develop patient-specific approaches,outline procedural steps,and prepare strategies for managing potential crises.During the operation,relevant data appear at the right moment to assist decision-making and guide performance in formats tailored to the surgeon’s physical and cognitive state,all without causing distractions.In the future operating room,performance data from surgeons will be gathered,integrated,and analyzed to interpret surgeons’behavior and confidence.Advanced techniques,including artificial intelligence,can be employed to automatically detect moments of performance difficulty or cognitive overload.As a result,digital surgery provides timely,context-specific assistance to surgeons in high-stakes situations.Key components of digital surgery are highlighted in this narrative review.
基金supported by grants from the Human Resources Development program (Grant No.20204010600250)the Training Program of CCUS for the Green Growth (Grant No.20214000000500)by the Korea Institute of Energy Technology Evaluation and Planning (KETEP)funded by the Ministry of Trade,Industry,and Energy of the Korean Government (MOTIE).
文摘It is of great importance to obtain precise trace data,as traces are frequently the sole visible and measurable parameter in most outcrops.The manual recognition and detection of traces on high-resolution three-dimensional(3D)models are relatively straightforward but time-consuming.One potential solution to enhance this process is to use machine learning algorithms to detect the 3D traces.In this study,a unique pixel-wise texture mapper algorithm generates a dense point cloud representation of an outcrop with the precise resolution of the original textured 3D model.A virtual digital image rendering was then employed to capture virtual images of selected regions.This technique helps to overcome limitations caused by the surface morphology of the rock mass,such as restricted access,lighting conditions,and shading effects.After AI-powered trace detection on two-dimensional(2D)images,a 3D data structuring technique was applied to the selected trace pixels.In the 3D data structuring,the trace data were structured through 2D thinning,3D reprojection,clustering,segmentation,and segment linking.Finally,the linked segments were exported as 3D polylines,with each polyline in the output corresponding to a trace.The efficacy of the proposed method was assessed using a 3D model of a real-world case study,which was used to compare the results of artificial intelligence(AI)-aided and human intelligence trace detection.Rosette diagrams,which visualize the distribution of trace orientations,confirmed the high similarity between the automatically and manually generated trace maps.In conclusion,the proposed semi-automatic method was easy to use,fast,and accurate in detecting the dominant jointing system of the rock mass.
基金supported by a grant from the Research Grant Council of Hong Kong Special Administrative Region(Project No.11207724).
文摘The development of digital twins for geotechnical structures necessitates the real-time updates of threedimensional(3D)virtual models(e.g.numerical finite element method(FEM)model)to accurately predict time-varying geotechnical responses(e.g.consolidation settlement)in a 3D spatial domain.However,traditional 3D numerical model updating approaches are computationally prohibitive and therefore difficult to update the 3D responses in real time.To address these challenges,this study proposes a novel machine learning framework called sparse dictionary learning(T-3D-SDL)for real-time updating of time-varying 3D geotechnical responses.In T-3D-SDL,a concerned dataset(e.g.time-varying 3D settlement)is approximated as a linear superposition of dictionary atoms generated from 3D random FEM analyses.Field monitoring data are then used to identify non-trivial atoms and estimate their weights within a Bayesian framework for model updating and prediction.The proposed approach enables the real-time update of temporally varying settlements with a high 3D spatial resolution and quantified uncertainty as field monitoring data evolve.The proposed approach is illustrated using an embankment construction project.The results show that the proposed approach effectively improves settlement predictions along temporal and 3D spatial dimensions,with minimal latency(e.g.within minutes),as monitoring data appear.In addition,the proposed approach requires only a reasonably small number of 3D FEM model evaluations,avoids the use of widely adopted yet often criticized surrogate models,and effectively addresses the limitations(e.g.computational inefficiency)of existing 3D model updating approaches.
文摘Archaeological excavation involves disintegration, removal, and reassembly of the archaeological record;as such it is considered by many to be an unrepeatable, destructive activity. This perception has contributed to an advancement in archaeological practice, namely, the development of computerized recording systems that digitally record archaeological excavations spatially and volumetrically during fieldwork. This paper is concerned with those archaeological sites where digital field recording has not been done. These sites, recorded by traditional methods, should not be excluded from attempts to restructure the spatial, volumetric, and stratigraphic archaeological data. A thorough methodology for the conversion of traditional records into digitized data is presented, including the detailed procedures required for three-dimensional plotting of recorded data—both the excavated material and the drawn site maps and cross-sections. Finally, the use of these methods is demonstrated on a complex Early to Middle Pleistocene site, illustrating the benefits of digitization and three-dimensional reconstruction in resolving stratigraphic and spatial questions.
文摘The feasibility of three-dimensional (3D) printing technology cgmbined with minimally invasive surgery in the treatment of pubic rami fractures was explored.From August 2015 to October 2017,a series of 30 patients who underwent surgical stabilization of their anterior pelvic ring (all utilizing the 3D printing technology)by one surgeon at a single hospital were studied.The minimally invasive incisions were made through anterior inferior cilia spine and pubic nodule.Data collected included the operative duration,the blood loss,the damage of the important tissue,the biographic union and therecovery of the function after the operation.Measurements on inlet and outlet pelvic cardiograph were made immediately post-operation and at all follow-up clinic visits.The scores of reduction and function were measured during follow-up.Results showed that the wounds of 30 patients were healed in the first stage,and there was no injury of important structures such as blood vessels and nerves.According to the Matta criteria,excellent effectiveness was obtained in 22 cases and good in 8 cases.According to the functional evaluation criteria of Majeed,excellent effectiveness was obtained in 21 cases and good in 9 cases.It was suggested that the 3D printing technology assisted by minimally invasive surgery can better evaluate the pelvic fracture before operation,which was helpful in plate modeling, and can shorten surgery duration and reduce intraoperative blood loss and complications. The positioning accuracy was improved,and better surgical result was finally achieved.
文摘Objective:This study investigated the effect of proximal contact strength on the three-dimensional displacements of cantilever fixed partial denture(CFPD) under vertically concentrated loading with digital laser speckle(DLS) technique.Methods:Fresh mandible of beagle dog was used to establish the implant-supported CFPD for specimen.DLS technique was employed for measuring the three-dimensional displacement of the prosthesis under vertically concentrated loading ranging from 200 to 3 000 g.The effect of the contact tightness on the displacement of CFPD was investigated by means of changing the contact tightness.Results:When an axial concentrated loading was exerted on the pontic of the implant-supported CFPD,the displacement of the CFPD was the greatest.The displacement of the prosthesis decreased with the increase of contact strength.When the contact strength was 0,0.95,and 3.25 N,the displacement of the buccolingual direction was smaller than that of the mesiodistal direction but greater than that of the occlusogingival direction.When the force on the contact area was 6.50 N,the mesiodistal displacement of the prosthesis was the biggest while the buccolingual displacement was the smallest.Conclusions:The implant supported CFPD is an effective therapy for fully or partially edentulous patients.The restoration of the contact area and the selection of the appropriate contact strength can reduce the displacement of the CFPD,and get a better stress distribution.The most appropriate force value is 3.25 N in this study.
基金This work was supported by grants from the National Nature Science Foundation of China(81701524,81871215)the Strategic Priority Research Program of the Chinese Academy of Sciences(XDA16020701)the National Key R&D Program of China(2017YFC1002003).
文摘Optimal vision and ergonomics are essential factors contributing to the achievement of good results during microsurgery.The three-dimensional(3D)digital image microscope system with a better 3D depth of field can release strain on the surgeon's neck and back,which can improve outcomes in microsurgery.We report a randomized prospective study of vasoepididymostomy and vasovasostomy using a 3D digital image microscope system(3D-DIM)in rats.A total of 16 adult male rats were randomly divided into two groups of 8 each:the standard operating microscope(SOM)group and the 3D-DIM group.The outcomes measured included the operative time,real-time postoperative mechanical patency,and anastomosis leakage.Furthermore,a user-friendly microscope score was designed to evaluate the ergonomic design and equipment characteristics of the microscope.There were no differences in operative time between the two groups.The real-time postoperative mechanical patency rates were 100.0%for both groups.The percentage of vasoepididymostomy anastomosis leakage was 16.7%in the SOM group and 25.0%in the 3D-DIM group;however,no vasovasostomy anastomosis leakage was found in either group.In terms of the ergonomic design,the 3D-DIM group obtained better scores based on the surgeon's feelings;in terms of the equipment characteristics,the 3D-DIM group had lower scores for clarity and higher scores for flexibility and adaptivity.Based on our randomized prospective study in a rat model,we believe that the 3D-DIM can improve surgeon comfort without compromising outcomes in male infertility reconstructive microsurgery,so the 3D-DIM might be widely used in the future.
文摘With regard to problems in conventional synthetic aperture radar (SAR), such as imaging distortion, beam limitation and failure in acquiring three-dimensional (3-D) information, a downward-looking 3-D imaging method based on frequency modulated continuous wave (FMCW) and digital beamforming (DBF) technology for airborne SAR is presented in this study. Downward-looking 3-D SAR signal model is established first, followed by introduction of virtual antenna optimization factor and discussion of equivalent-phase-center compensation. Then, compensation method is provided according to reside video phase (RVP) and slope term for FMCW SAR. As multiple receiving antennas are applied to downward-looking 3-D imaging SAR, range cell migration correction (RCMC) turns to be more complex, and corrective measures are proposed. In addition, DBF technology is applied in realizing cross-track resolution. Finally, to validate the proposed method, magnitude of slice, peak sidelobe ratio (PSLR), integrated sidelobe ratio (ISLR) and two-dimensional (2-D) contour plot of impulse response function (IRF) of point target in three dimensions are demonstrated. Satisfactory performances are shown by simulation results.
基金funded by the Natural Science and Engineering Research Council (NSERC) of Canada (No. RGPIN-2014-04100)
文摘Sampling design(SD) plays a crucial role in providing reliable input for digital soil mapping(DSM) and increasing its efficiency.Sampling design, with a predetermined sample size and consideration of budget and spatial variability, is a selection procedure for identifying a set of sample locations spread over a geographical space or with a good feature space coverage. A good feature space coverage ensures accurate estimation of regression parameters, while spatial coverage contributes to effective spatial interpolation.First, we review several statistical and geometric SDs that mainly optimize the sampling pattern in a geographical space and illustrate the strengths and weaknesses of these SDs by considering spatial coverage, simplicity, accuracy, and efficiency. Furthermore, Latin hypercube sampling, which obtains a full representation of multivariate distribution in geographical space, is described in detail for its development, improvement, and application. In addition, we discuss the fuzzy k-means sampling, response surface sampling, and Kennard-Stone sampling, which optimize sampling patterns in a feature space. We then discuss some practical applications that are mainly addressed by the conditioned Latin hypercube sampling with the flexibility and feasibility of adding multiple optimization criteria. We also discuss different methods of validation, an important stage of DSM, and conclude that an independent dataset selected from the probability sampling is superior for its free model assumptions. For future work, we recommend: 1) exploring SDs with both good spatial coverage and feature space coverage; 2) uncovering the real impacts of an SD on the integral DSM procedure;and 3) testing the feasibility and contribution of SDs in three-dimensional(3 D) DSM with variability for multiple layers.
基金supported by the National Natural Science Foundation of China (11722221, 11272305, and 11472265)the National Key Research and Development Program of China (2017YFA0403800 and 2017YFB0702000)the Anhui Provincial Natural Science Foundation (1508085MA17)
文摘Characterizing material 3D deformation and damage is a key challenge in mechanical research. Digital volume correlation (DVC), as a tool for quantifying the internal mechanical response, can comprehensively study the extraction of key failure parameters. This review summarizes the recent progresses in the study of the internal movement of granular materials, inhomogeneous deformation of composite materials, and stress intensity factor around a crack front in static and fatigue states using DVC. To elaborate on the technique's potential, we discussed the accuracy and efficiency of the algorithm and the acquisition of real microstructure data within the material under a complex environment.
基金supported by the National Key R&D Program of China (Award No.2022YFC3401100)the National Natural Science Foundation of China。
文摘In recent years,notable progress has been achieved in both the hardware and algorithms of structured illumination microscopy(SIM).Nevertheless,the advancement of three-dimensional structured illumination microscopy(3DSIM)has been impeded by challenges arising from the speed and intricacy of polarization modulation.We introduce a high-speed modulation 3DSIM system,leveraging the polarizationmaintaining and modulation capabilities of a digital micromirror device(DMD)in conjunction with an electrooptic modulator.The DMD-3DSIM system yields a twofold enhancement in both lateral(133 nm)and axial(300 nm)resolution compared to wide-field imaging and can acquire a data set comprising 29 sections of 1024 pixels×1024 pixels,with 15 ms exposure time and 6.75 s per volume.The versatility of the DMD-3DSIM approach was exemplified through the imaging of various specimens,including fluorescent beads,nuclear pores,microtubules,actin filaments,and mitochondria within cells,as well as plant and animal tissues.Notably,polarized 3DSIM elucidated the orientation of actin filaments.Furthermore,the implementation of diverse deconvolution algorithms further enhances 3D resolution.The DMD-based 3DSIM system presents a rapid and reliable methodology for investigating biomedical phenomena,boasting capabilities encompassing 3D superresolution,fast temporal resolution,and polarization imaging.
文摘Objective: We constructed 3D-model of ONFH in computer according to three-dimensional computerized tomography (3D-CT) data. We determined the location and volume of necrosis to investigate its clinical efficacy. Method: Totally 92 hips (59 cases) with ONFH (44 males, 15 females) were included, with mean age of 37.5 years (range from 26 to 58). Totally 20 cases (35 hips) were induced by corticosteroid (CTSs), 31 (49 hips) induced by alcohol, 4 (4 hips) induced by trauma and 4 (4 hips) idiopathic. All the hips were categorized into stage ARCO II. Finally diagnosed by MRI, all hips were scanned by CT to acquire data in DICOM format. The images were imported into software to extract 3D-shape of femoral heads, necrotic foci, their volumes and distribution in each quadrant. Deviation of volumes between digital image and biopsy specimen was analyzed by SAS9.1 package. Correlativity between collapse and volume of necrosis under specific pathogeneses was also analyzed. Among the cases necessitating total hip arthroplasty (THA) due to advancing to ARCO III, we randomly selected 8 of them to perform 3D-CT scanning thrice prior to surgical operation. Total femoral heads harvested were torn asunder. Cubic capacity of femoral heads and necrotic foci were hereby measured and compared with those acquired from digital models. Result: Through the digital model, necrotic foci were found mainly locating within the super lateral portion of femoral head, coinciding with those observed in biopsy specimen. Average volumetric ratio of digitally acquired necrosis focus/femoral head in 58 collapsed hips was 36.8%. The ratio of the 34 hips without collapse was 17.3%. In collapsed femoral heads, the distribution of necrosis focus was 23.4% in quadrant 1 (q1), 23.6% in q2, 12.1% in q3, 14.4% in q4, 9.0% in q5, 11.8% in q6, 1.6% in q7 and 3.9% in q8. In femoral heads without collapse, the distribution was 34.2% in q1, 29.6% in q2, 11.8% in q3, 11.3% in q4, 6.0% in q5, 6.0% in q6, 0.5% in q7 and 0.4% in q8. As for the average cubic capacities of femoral heads and necrotic foci, those acquired from the digital model and biopsy specimen had no significant difference in matched-pairs test (t = -1.49, P = 0.179 for femoral heads and t = -1.52, P = 0.172 for necrotic foci). There was significant difference (F = 2.720, P = 0.035 P was respectively 0.0001 and 0.0005). Decision tree model showed that 94.6% (53/56) hips would progress into collapse if the volumetric ratio of necrotic tissue was over 23.48%. Otherwise, if distribution in q2 was over 45.13%, 83.3% (5/6) hips would progress into collapse. No collapse (0/30) would occur if the distribution of necrotic tissue in q2 was under 45.13%. Conclusion: Digital 3D-model reconstructed from CT scanning can precisely incarnate spatial orientation of necrotic foci in femoral head. Multinomial logistic regression and decision-making tree shows that volumetric ratio of necrotic tissues plays an important role in anticipating collapse of femoral head.
文摘We compared reconstruction algorithms [filtered back projection (FBP), maximum likelihood expectation maximization (MLEM), and the simultaneous iterative reconstruction technique (SIRT)] in terms of the radiation dose and image quality, for exploring the possibility of decreasing the radiation dose during digital breast tomosynthesis (DBT). The three algorithms were implemented using a DBT system and experimentally evaluated using measurements, such as signal difference-to-noise ratio (SDNR) and intensity profile, on a BR3D phantom (infocus plane image). The possible radiation dose reduction, contrast improvement, and artifact reduction in DBT were evaluated using different exposure levels and the three reconstruction techniques. We performed statistical analysis (one-way analysis of variance) of the SDNR data. The effectiveness of each technique for enhancing the visibility of the BR3D phantom was quantified with regard to SDNR (FBP versus MLEM, P < 0.05;FBP vs. SIRT, P < 0.05;MLEM vs. SIRT, P = 0.945);the artifact reduction was quantified with regard to the intensity profile. MLEM and SIRT produced reconstructed images with SDNR values indicative of low-contrast visibility. The SDNR value for the half-radiation dose MLEM and SIRT images was close to that of the FBP reference radiation dose image. Artifacts were decreased in the MLEM and SIRT images (in the infocus plane) according to the intensity profiles that we obtained. With MLEM and SIRT, the radiation dose may be decreased to half comparison with FBP.