期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Perceptions of Digital Monitoring Technology for Activities of Daily Living(ADLs):A Semi-Structured Interview Study of Older Adults and Informal Caregivers
1
作者 Zhiyuan Xiao Yu Hou Haorui Li 《Journal of Electronic Research and Application》 2025年第3期178-192,共15页
With China’s rapidly aging population and the growing preference for aging in place,digital monitoring technologies have emerged as potential tools to support older adults in managing their activities of daily living... With China’s rapidly aging population and the growing preference for aging in place,digital monitoring technologies have emerged as potential tools to support older adults in managing their activities of daily living(ADLs).This study explores the perceptions and acceptance of these technologies among elderly individuals living alone and their informal caregivers(ICs)in Nanshan District,Shenzhen.Grounded in the Unified Theory of Acceptance and Use of Technology(UTAUT),the study employed semi-structured and photo-elicitation interviews to analyze how performance expectancy,effort expectancy,social influence,and facilitating conditions shape technology adoption.The findings reveal clear intergenerational differences:caregivers show higher acceptance and a better understanding of the benefits and functionalities of wearable and environmental monitoring devices,while older adults often express skepticism due to concerns over privacy,usability,and cost.Many elderly participants also cite discomfort,technical complexity,and lack of training as barriers to adoption.Despite these obstacles,both groups acknowledge the potential safety and health benefits of such technologies.The study highlights the need for privacy-by-design features,customized user interfaces,and enhanced digital literacy programs tailored to both elderly users and their caregivers.The research contributes to a sociotechnical understanding of aging-in-place technologies in China and provides actionable insights for developers,policymakers,and healthcare practitioners aiming to enhance home-based elder care. 展开更多
关键词 digital monitoring technology Activities of daily living(ADLs) Aging in place Informal caregivers UTAUT model
在线阅读 下载PDF
Research On The Application Of Digital Monitoring In The Field Of Junior Golf Technology
2
作者 Xiaopan Ling Yangyuan Tang kelin Jin 《Education and Teaching Research》 2025年第1期14-19,共6页
In order to effectively improve the hitting level of the first wood swing of young golfers and improve sports performance,this paper conducted experimental research on 20 young golfers through the research methods of ... In order to effectively improve the hitting level of the first wood swing of young golfers and improve sports performance,this paper conducted experimental research on 20 young golfers through the research methods of literature,experiment and mathematical statistics,and discussed the influence of digital monitoring application on the hitting effect of the first wood of young golfers.In this paper,the experimental group and the control group were set up,the experimental group was added with digital monitoring,and the control group received routine training.Finally,the conclusion was drawn that:After the experiment,the club head speed and the total distance of the first wood swing in the experimental group had significant positive effects,and were obviously better than the control group;Compared with the data before and after the test of the batting effect index of the No.1 wood swing in the experimental group,although the test results of the left and right Angle Index did not show significant difference,the effect was better than that of the control group with certain positive effects;Digital monitoring can effectively improve the level of young golfers’first-wood swing hitting skills,and students with good index test results will have better first-wood swing hitting effects.Therefore,in order to further improve the first-wood hitting effect of young golfers,digital monitoring equipment should be actively introduced in daily training to provide diversified teaching support and guidance for the improvement of young golfers hitting skills. 展开更多
关键词 digital monitoring TEENAGERS GOLF First tree
在线阅读 下载PDF
Damage evaluation of notched aluminum alloy and weld based on acoustic emission and digital image monitoring
3
作者 朱荣华 刚铁 《China Welding》 EI CAS 2013年第1期11-15,共5页
Acoustic emission ( AE ) features during the fracture process of notched wrought aluminum alloy 7N01 and weld were investigated under the three-point bending load. Wavelet transform is used to investigate the time-f... Acoustic emission ( AE ) features during the fracture process of notched wrought aluminum alloy 7N01 and weld were investigated under the three-point bending load. Wavelet transform is used to investigate the time-frequency features of AE signals during the test. The experimental results showed that AE energy was effective indicators to detect the crack initiation for 7N01 aluminum. The digital images from monitoring the notch tip region of 7 NO1 aluminum sample verify the prediction of AE signals. The weld emits low energy, weak signal strength, and low peak amplitude, while stronger AE energy, amplitude, and more AE event counts for the base metal. In short, the AE technique was more sensitive to the changes in the fracture mode and could be used to monitor the damage development in welded structures. 展开更多
关键词 aluminum alloy crack initiation digital image monitor acoustic emission energy peak frequency
在线阅读 下载PDF
Accuracy of Mean Value of Central Venous Pressure from Monitor Digital Display: Influence of Amplitude of Central Venous Pressure during Respiration
4
作者 Meng-Ru Xu Wang-Lin Liu +4 位作者 Huai-Wu He Xiao-Li Lai Mei-Ling Zhao Da-Wei Liu Yun Long 《Chinese Medical Sciences Journal》 CAS CSCD 2023年第2期117-124,共8页
Background A simple measurement of central venous pressure(CVP)-mean by the digital monitor display has become increasingly popular.However,the agreement between CVP-mean and CVP-end(a standard method of CVP measureme... Background A simple measurement of central venous pressure(CVP)-mean by the digital monitor display has become increasingly popular.However,the agreement between CVP-mean and CVP-end(a standard method of CVP measurement by analyzing the waveform at end-expiration)is not well determined.This study was designed to identify the relationship between CVP-mean and CVP-end in critically ill patients and to introduce a new parameter of CVP amplitude(ΔCVP=CVPmax-CVPmin)during the respiratory period to identify the agreement/disagreement between CVP-mean and CVP-end.Methods In total,291 patients were included in the study.CVP-mean and CVP-end were obtained simultaneously from each patient.CVP measurement difference(|CVP-mean-CVP-end|)was defined as the difference between CVP-mean and CVP-end.TheΔCVP was calculated as the difference between the peak(CVPmax)and the nadir value(CVPmin)during the respiratory cycle,which was automatically recorded on the monitor screen.Subjects with|CVP-mean-CVP-end|≥2 mm Hg were divided into the inconsistent group,while subjects with|CVP-mean-CVP-end|2 mm Hg were divided into the consistent group.ResultsΔCVP was significantly higher in the inconsistent group[7.17(2.77)vs.5.24(2.18),P0.001]than that in the consistent group.There was a significantly positive relationship betweenΔCVP and|CVP-mean-CVP-end|(r=0.283,P 0.0001).Bland-Altman plot showed the bias was-0.61 mm Hg with a wide 95%limit of agreement(-3.34,2.10)of CVP-end and CVP-mean.The area under the receiver operating characteristic curves(AUC)ofΔCVP for predicting|CVP-mean-CVP-end|≥2 mm Hg was 0.709.With a high diagnostic specificity,usingΔCVP3 to detect|CVP-mean-CVP-end|lower than 2mm Hg(consistent measurement)resulted in a sensitivity of 22.37%and a specificity of 93.06%.UsingΔCVP8 to detect|CVP-mean-CVPend|8 mm Hg(inconsistent measurement)resulted in a sensitivity of 31.94%and a specificity of 91.32%.Conclusions CVP-end and CVP-mean have statistical discrepancies in specific clinical scenarios.ΔCVP during the respiratory period is related to the variation of the two CVP methods.A highΔCVP indicates a poor agreement between these two methods,whereas a lowΔCVP indicates a good agreement between these two methods. 展开更多
关键词 central venous pressure monitor digital display monitor cursor-line display RESPIRATION
暂未订购
Co-seismic changes of well water level and volume strain meter in capital area and its vicinity,due to the Nov.14,2001 Ms8.1 Kunlun Mountain earthquake,China 被引量:3
5
作者 Huang Fuqiong Chen Yong +3 位作者 Ji Ping Ren Kexin Gao Fuwang Zhang Lingkong 《Geodesy and Geodynamics》 2015年第6期460-466,共7页
The Kunlunshan Mountain Ms8.1 earthquake, occurred in Nov.14, 2001, is the first event with magnitude more than 8 in the China earthquake monitoring history, specifically at the beginning of digital techniques in prec... The Kunlunshan Mountain Ms8.1 earthquake, occurred in Nov.14, 2001, is the first event with magnitude more than 8 in the China earthquake monitoring history, specifically at the beginning of digital techniques in precursor monitoring networks. Any investigation of recorded data on this earthquake is very important for testing the operation of the digital monitoring networks and understanding the preparation, occurrence, and adjustment of stress/strain of strong continental earthquakes. In this paper we investigated the coseismic response changes of well water level of groundwater and volume strain meter of bore hole in digital earthquake monitoring network of Capital area and its vicinity, due to the Nov.14, 2001 Ms8.1 Kunlun Mountain earthquake. The responding time, shapes or manners, amplitudes, and lasting time of well water level and strain-meters to seismic wave are studied in comparison. Then we discussed the possibility that the response changes of groundwater to strong distant earthquakes can be understood as one kind of observing evidence of stress/strain changes induced by distant earthquake. 展开更多
关键词 Kunlun Mountain earthquake Co-seismic response Groundwater level in wells Volume strain meter in borehole Capital area digital monitoring network 9th Five-Year Plan Long range correlation
原文传递
Design of 4.25 Gbps Small Form-factor Pluggable(SFP) Transceiver 被引量:1
6
作者 HU Wei WANG Li LIU Bi-Chen 《Semiconductor Photonics and Technology》 CAS 2009年第1期56-62,共7页
Compact, hot-pluggable, and data-agnostic, SFP modules bring up to 4.25 Gbps to a flexible new form factor. The SFP transceiver which is the core device of optical communication is always the research focus in the fie... Compact, hot-pluggable, and data-agnostic, SFP modules bring up to 4.25 Gbps to a flexible new form factor. The SFP transceiver which is the core device of optical communication is always the research focus in the field of optical communication for both telecommunication and data communication applications. The working principles of SFP including the transmitter components, the receiver components and the microcontroller are discussed in detail. The basic theory of high-speed signal and the concept of high - speed circuit, high-speed board design techniques are presented. A new design of high performance, cost effective SFP transceiver and PCB layout are also presented. The performance of the transceiver is analyzed and the characteristics of the sample are coincident with the expected ones. The status of the transceiver can be monitored and controlled by F C bus through the interface in real time. This transceiver can meet the requirement of SFF-8472. 展开更多
关键词 SFP digital diagnostic monitoring high-speed digital circuit IZC bus
在线阅读 下载PDF
Automatic test system development for digital beam position monitor of HEPS and BEPCII
7
作者 Xuhui Tang Yaoyao Du +9 位作者 Jianshe Cao Shujun Wei Zhi Liu Qiang Ye Huizhou Ma Jing Yang Guodong Gao Yukun Li Yanfeng Sui Junhui Yue 《Radiation Detection Technology and Methods》 CSCD 2022年第3期330-338,共9页
Purpose Hundreds of digital beam position monitor processors(DBPM)are required to be produced during the construction of projects such as High Energy Photon Source(HEPS)and the upgrade project of the Beijing Electron ... Purpose Hundreds of digital beam position monitor processors(DBPM)are required to be produced during the construction of projects such as High Energy Photon Source(HEPS)and the upgrade project of the Beijing Electron Positron Collider(BEPCII),which brings great challenges to the test work.In order to achieve accurate,fast,and complete mass production tests of DBPMs,an automatic test system(ATS)has been developed in this article.Methods According to the test items of DBPM,the standardized testing softwareflow is designed based on virtual instru-ment program control technology and experimental physics and industrial control system(EPICS),which realize automatic adjustment of test parameters and automatic acquisition of test result data.Results and conclusions The ATS can realize one-button testing of channel coefficients,channel linearity,attenuator linearity,beam current dependence(BCD)and sampling signal-to-noise ratio(SNR),and generate test reports.The total test time is less than 3 minutes,which is significantly more efficient compared to manual testing.More than 90 BEPCII DBPMs has been tested by this ATS in the lab.The test results proved that such a system could automatically recognize defective products and satisfy the requirements of mass testing. 展开更多
关键词 Automatic test system digital beam position monitor processor Program control Experimental physics and industrial control system Analog-to-digital converter
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部