期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Detector array with digital data acquisition system for charged-particle decay studies
1
作者 Hao Jian Xin-Xing Xu +40 位作者 Kai-Long Wang Jia-Jian Liu Chao-Yi Fu Peng-Jie Li Yan-Yun Yang Guang-Xin Zhang Kang Wang Fang-Fang Duan Long-Hui Ru Guang-Shun Li Bing Ding Yun-Hua Qiang Cen-Xi Yuan Jun-Bing Ma Shi-Wei Xu Yu-Feng Gao Rui Fan Fan-Chao Dai Si-Xian Zha Hao-Fan Zhu Jin-Hai Li Shu-Lian Qin Zhi-Fang Chang Cheng Kong He-Xuan Yan Hao-Wei Xu Jia-Long Ning Bo-Ren Liu Jie Zhou Yu-Dong Chen Bo-Shuai Cai Yu-Ting Wang Hong-Yi Wu Zhi-Xuan Wang Dong-Sheng Hou Hu-Shan Xu Xiao-Hong Zhou Yu-Hu Zhang Meng Wang Zheng-Guo Hu Jenny Lee 《Nuclear Science and Techniques》 2025年第4期140-150,共11页
A state-of-the-art detector array with a digital data acquisition system has been developed for charged-particle decay studies,includingβ-delayed protons,αdecay,and direct proton emissions from exotic proton-rich nu... A state-of-the-art detector array with a digital data acquisition system has been developed for charged-particle decay studies,includingβ-delayed protons,αdecay,and direct proton emissions from exotic proton-rich nuclei.The digital data acquisition system enables precise synchronization and processing of complex signals from various detectors,such as plastic scintillators,silicon detectors,and germaniumγdetectors.The system's performance was evaluated using theβdecay of^(32)Ar and its neighboring nuclei,produced via projectile fragmentation at the first Radioactive Ion Beam Line in Lanzhou(RIBLL1).Key measurements,including the half-life,charged-particle spectrum,andγ-ray spectrum,were obtained and compared with previous results for validation.Using the implantation–decay method,the isotopes of interest were implanted into two doublesided silicon strip detectors,where their subsequent decays were measured and correlated with preceding implantations using both position and time information.This detection system has potential for further applications,including the study ofβ-delayed charged-particle decay and direct proton emissions from even more exotic proton-rich nuclei. 展开更多
关键词 β-delayed proton decay Double-sided silicon strip detector High-purity germanium detector digital data acquisition system Implantation–decay correlation
在线阅读 下载PDF
Performance of digital data acquisition system in gamma-ray spectroscopy 被引量:4
2
作者 Di-Wen Luo Hong-Yi Wu +9 位作者 Zhi-Huan Li Chuan Xu Hui Hua Xiang-Qing Li Xiang Wang Shuang-Quan Zhang Zhi-Qiang Chen Chen-Guang Wu Yu Jin Jie Lin 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第8期12-22,共11页
A newly developed digital data acquisition system,which is based on the digital pulse processor Pixie-16 modules by XIA LLC,was tested with the c-ray detector array of the China Institute of Atomic Energy using the cr... A newly developed digital data acquisition system,which is based on the digital pulse processor Pixie-16 modules by XIA LLC,was tested with the c-ray detector array of the China Institute of Atomic Energy using the cray source and in-beam c-rays.A comparison between this digital data acquisition system and the conventional analog data acquisition system was made.At a low count rate,both systems exhibit good and comparable energy resolutions.At a high count rate above 8.8 k/s,while the energy resolution obtained by the analog system deteriorates significantly,the energy resolution obtained by the digital system is nearly unchanged.Meanwhile,experimental data with higher statistics can be collected by the digital system.The advantage of this digital system over the conventional analog system can be ascribed to its excellent capability of handling pile-up pulses at higher count rates,and the fact that it has nearly no dead time in data transmission and conversion. 展开更多
关键词 digital data acquisition system Gamma spectroscopy Energy resolution
在线阅读 下载PDF
Images of triple gas electron multiplier with pixel-pads 被引量:4
3
作者 董静 胡碧涛 +1 位作者 陈元柏 谢一冈 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第10期4229-4233,共5页
Testing of a triple gas electron multiplier (GEM) with pixel-pads is described. Images by scanning and suspending radioactive sources were obtained by using 96 channels digital data acquisition (DAQ) system which ... Testing of a triple gas electron multiplier (GEM) with pixel-pads is described. Images by scanning and suspending radioactive sources were obtained by using 96 channels digital data acquisition (DAQ) system which was composed of 96 8×8 mm2 pads and associated electronics channels. 展开更多
关键词 gas electron multiplier IMAGES digital data acquisition system
原文传递
上一页 1 下一页 到第