An anomalous total dose effect that the long length device is more susceptible to total ionizing dose than the short one is observed with the 0.13?μm partially depleted silicon-on-insulator technology. The measured ...An anomalous total dose effect that the long length device is more susceptible to total ionizing dose than the short one is observed with the 0.13?μm partially depleted silicon-on-insulator technology. The measured results and 3D technology computer aided design simulations demonstrate that the devices with different channel lengths may exhibit an enhanced reverse short channel effect after radiation. It is ascribed to that the halo or pocket implants introduced in processes results in non-uniform channel doping profiles along the device length and trapped charges in the shallow trench isolation regions.展开更多
AIM:To investigate the binocular intraocular lens(IOL)power difference in eyes with short,normal,and long axial lengths(AL)using Lenstar LS 900 optical biometry.METHODS:A total of 716(1432 eyes)participants were inclu...AIM:To investigate the binocular intraocular lens(IOL)power difference in eyes with short,normal,and long axial lengths(AL)using Lenstar LS 900 optical biometry.METHODS:A total of 716(1432 eyes)participants were included.The groups were categorized into short(group A:AL<22 mm),normal(group B:22 mm≤AL≤25 mm),and long AL groups(group C:AL>25 mm).The central corneal thickness(CCT),anterior chamber depth(ACD),lens thickness(LT),AL,anterior corneal keratometry,whiteto-white(WTW),pupil diameter(PD),as well as IOL power calculated using embedded Barrett formula were assessed.Bland-Altman plots were used to test the agreement of the binocular parameters.RESULTS:In group A,the CCT of the right eye was significantly thinner than that of the left eye(P=0.044)with a difference of-2±8μm[95%limits of agreement(LoA),-17.8 to 13.2μm].For group B,the PD and IOL power in the right eye were significantly lower than those of the left eye(P=0.001,<0.001)with a difference of-0.05±0.32 mm(95%LoA,-0.68 to 0.58 mm)and-0.18±1.01 D(95%LoA,-2.2 to 1.8 D).The AL of right eye was longer than that of the left eye(P=0.002)with a difference of 0.04±0.25 mm(95%Lo A,-0.45 to 0.52 mm).No significant difference was observed for all the binocular parameters in group C.The percentage of participants with binocular IOL power difference within±0.5 D were 62%(31/50),68.3%(339/496),and 38.8%(66/170)in groups A,B,and C,respectively.CONCLUSION:The binocular parameters related to IOL power are in good agreement,but the binocular IOL power difference of more than half of participants with long AL is more than 0.50 D.展开更多
A study of the quenching of pyrene fluorescence by a series of alkyltriphenylphosphonium bromides indi- cated the coiling conformation of ionic surfactant in aqueous solution.Formation of pyrene excimer in cetyltriph-...A study of the quenching of pyrene fluorescence by a series of alkyltriphenylphosphonium bromides indi- cated the coiling conformation of ionic surfactant in aqueous solution.Formation of pyrene excimer in cetyltriph- enylphosphonium solution strengthened the conclusion.展开更多
Objective To investigate the changing regularity of thoracic pedicle screw channel (PSC) in different transverse screw angle(TSA).Methods CT scan images of thoracic vertebrae of a healthy adult ware digitally analyzed...Objective To investigate the changing regularity of thoracic pedicle screw channel (PSC) in different transverse screw angle(TSA).Methods CT scan images of thoracic vertebrae of a healthy adult ware digitally analyzed by Mimics 10.01展开更多
With the popularity of indoor wireless network,device-free indoor localization has attracted more and more attention.Unlike device-based localization where the target is required to carry an active transmitter,their f...With the popularity of indoor wireless network,device-free indoor localization has attracted more and more attention.Unlike device-based localization where the target is required to carry an active transmitter,their frequent signal scanning consumes a large amount of energy,which is inconvenient for devices with limited energy.In this work,we propose the MFPL,device-free localization(DFL)system based on WiFi distance measurement.First,we combine multi-subcarrier characteristic of Channel State Information(CSI)with classical Fresnel reflection model to get the linear relationship between the change of the length of reflection path and the subcarrier phase difference.Then we calculate the Fresnel phase difference between subcarrier pairs with different spacing from CSI amplitude time series.Finally,we get the change of the length of the reflection path caused by target moving to achieve distance measurement and localization.Using a combination of subcarriers with different spacing to achieve distance measurement effectively broadens the maximum unambiguous distance of the system.To solve the complex non-linear problem of the intersection of two elliptic equations,we introduce Newton's method to transform the non-linear problem into a linear one.The effectiveness of our approach is verified using commodity WiFi infrastructures.The experimental results show our method achieves a median error of 0.87 m in actual indoor environment.展开更多
We study the energy scaling of terahertz (THz) emission through difference frequency generation of near-infrared pulses, and demonstrate that Gigawatt few-cycle THz transients at the central frequency of 30 THz are pr...We study the energy scaling of terahertz (THz) emission through difference frequency generation of near-infrared pulses, and demonstrate that Gigawatt few-cycle THz transients at the central frequency of 30 THz are produced from GaSe crystal pumped by two pulses at 1.65 and 1.95 micrometers, with the high quantum yield of 28%. Our analysis indicates that the high yield of DFG originates from the largely reduced group velocity mismatch as the long-wavelength pumping pulses are employed.展开更多
In this article,novel smoothness indicators are presented for calculating the nonlinear weights of the weighted essentially non-oscillatory scheme to approximate the viscosity numerical solutions of Hamilton-Jacobi eq...In this article,novel smoothness indicators are presented for calculating the nonlinear weights of the weighted essentially non-oscillatory scheme to approximate the viscosity numerical solutions of Hamilton-Jacobi equations.These novel smoothness indicators are constructed from the derivatives of reconstructed polynomials over each sub-stencil.The constructed smoothness indicators measure the arc-length of the reconstructed polynomials so that the new nonlinear weights could get less absolute truncation error and give a high-resolution numerical solution.Extensive numerical tests are conducted and presented to show the performance capability and the numerical accuracy of the proposed scheme with the comparison to the classical WENO scheme.展开更多
A gated service single vacation M/G/1 queue with setup and closedown periods,and different customer arrival rates,is studied in this paper.The probability generating function of the number of systems for customers who...A gated service single vacation M/G/1 queue with setup and closedown periods,and different customer arrival rates,is studied in this paper.The probability generating function of the number of systems for customers who are at the initial moment of service period is analyzed by using a total probability theorem,and the stability condition of the system is obtained.The stationary distribution of the queue length is solved by the regeneration cycle method.The stochastic decomposition of queue length in the steady state is calculated,and the service cycle is obtained.Moreover,classified discussions are established in order to solve the steady-state distribution for the waiting time.The variation of system performance indicators with parameters is analyzed by performing numerical experiments.展开更多
For different external cavity lengths, lasing wavelength variation of fiber grating external cavity semiconductor laser (FGECSL) with ambient temperature has been investigated theoretically, and the theoretical result...For different external cavity lengths, lasing wavelength variation of fiber grating external cavity semiconductor laser (FGECSL) with ambient temperature has been investigated theoretically, and the theoretical results are in agreement with reported experimental observations.展开更多
基金Supported by the Weapon Equipment Pre-Research Foundation of China under Grant No 9140A11020114ZK34147the Shanghai Municipal Natural Science Foundation under Grant Nos 15ZR1447100 and 15ZR1447200
文摘An anomalous total dose effect that the long length device is more susceptible to total ionizing dose than the short one is observed with the 0.13?μm partially depleted silicon-on-insulator technology. The measured results and 3D technology computer aided design simulations demonstrate that the devices with different channel lengths may exhibit an enhanced reverse short channel effect after radiation. It is ascribed to that the halo or pocket implants introduced in processes results in non-uniform channel doping profiles along the device length and trapped charges in the shallow trench isolation regions.
基金Supported by the National Natural Science Foundation of China(No.81971697No.81501544)+1 种基金Shanxi Scholarship Council of China(No.2021-174)the Research Funding of Shanxi Eye Hospital(No.B201804)。
文摘AIM:To investigate the binocular intraocular lens(IOL)power difference in eyes with short,normal,and long axial lengths(AL)using Lenstar LS 900 optical biometry.METHODS:A total of 716(1432 eyes)participants were included.The groups were categorized into short(group A:AL<22 mm),normal(group B:22 mm≤AL≤25 mm),and long AL groups(group C:AL>25 mm).The central corneal thickness(CCT),anterior chamber depth(ACD),lens thickness(LT),AL,anterior corneal keratometry,whiteto-white(WTW),pupil diameter(PD),as well as IOL power calculated using embedded Barrett formula were assessed.Bland-Altman plots were used to test the agreement of the binocular parameters.RESULTS:In group A,the CCT of the right eye was significantly thinner than that of the left eye(P=0.044)with a difference of-2±8μm[95%limits of agreement(LoA),-17.8 to 13.2μm].For group B,the PD and IOL power in the right eye were significantly lower than those of the left eye(P=0.001,<0.001)with a difference of-0.05±0.32 mm(95%LoA,-0.68 to 0.58 mm)and-0.18±1.01 D(95%LoA,-2.2 to 1.8 D).The AL of right eye was longer than that of the left eye(P=0.002)with a difference of 0.04±0.25 mm(95%Lo A,-0.45 to 0.52 mm).No significant difference was observed for all the binocular parameters in group C.The percentage of participants with binocular IOL power difference within±0.5 D were 62%(31/50),68.3%(339/496),and 38.8%(66/170)in groups A,B,and C,respectively.CONCLUSION:The binocular parameters related to IOL power are in good agreement,but the binocular IOL power difference of more than half of participants with long AL is more than 0.50 D.
文摘A study of the quenching of pyrene fluorescence by a series of alkyltriphenylphosphonium bromides indi- cated the coiling conformation of ionic surfactant in aqueous solution.Formation of pyrene excimer in cetyltriph- enylphosphonium solution strengthened the conclusion.
文摘Objective To investigate the changing regularity of thoracic pedicle screw channel (PSC) in different transverse screw angle(TSA).Methods CT scan images of thoracic vertebrae of a healthy adult ware digitally analyzed by Mimics 10.01
基金This work is supported in part by National Natural Science Foundation of China(61771083,61704015)the Program for Changjiang Scholars and Innovative Research Team in University(IRT1299)+2 种基金Fundamental and Frontier Research Project of Chongqing(Nos.cstc2017jcyjAX0380,cstc2015jcyjBX0065)Sichuan Science and Technology Program(2018GZ0184)University Outstanding Achievement Transformation Project of Chongqing(No.KJZH17117).
文摘With the popularity of indoor wireless network,device-free indoor localization has attracted more and more attention.Unlike device-based localization where the target is required to carry an active transmitter,their frequent signal scanning consumes a large amount of energy,which is inconvenient for devices with limited energy.In this work,we propose the MFPL,device-free localization(DFL)system based on WiFi distance measurement.First,we combine multi-subcarrier characteristic of Channel State Information(CSI)with classical Fresnel reflection model to get the linear relationship between the change of the length of reflection path and the subcarrier phase difference.Then we calculate the Fresnel phase difference between subcarrier pairs with different spacing from CSI amplitude time series.Finally,we get the change of the length of the reflection path caused by target moving to achieve distance measurement and localization.Using a combination of subcarriers with different spacing to achieve distance measurement effectively broadens the maximum unambiguous distance of the system.To solve the complex non-linear problem of the intersection of two elliptic equations,we introduce Newton's method to transform the non-linear problem into a linear one.The effectiveness of our approach is verified using commodity WiFi infrastructures.The experimental results show our method achieves a median error of 0.87 m in actual indoor environment.
基金Supported by the National Natural Science Foundation of China under Grant Nos 11274326,61221064,61405222,11134010 and 11127901the Shanghai Sailing Program under Grant No 14YF1406200
文摘We study the energy scaling of terahertz (THz) emission through difference frequency generation of near-infrared pulses, and demonstrate that Gigawatt few-cycle THz transients at the central frequency of 30 THz are produced from GaSe crystal pumped by two pulses at 1.65 and 1.95 micrometers, with the high quantum yield of 28%. Our analysis indicates that the high yield of DFG originates from the largely reduced group velocity mismatch as the long-wavelength pumping pulses are employed.
文摘In this article,novel smoothness indicators are presented for calculating the nonlinear weights of the weighted essentially non-oscillatory scheme to approximate the viscosity numerical solutions of Hamilton-Jacobi equations.These novel smoothness indicators are constructed from the derivatives of reconstructed polynomials over each sub-stencil.The constructed smoothness indicators measure the arc-length of the reconstructed polynomials so that the new nonlinear weights could get less absolute truncation error and give a high-resolution numerical solution.Extensive numerical tests are conducted and presented to show the performance capability and the numerical accuracy of the proposed scheme with the comparison to the classical WENO scheme.
基金supported by the National Natural Science Foundation of China(61973261)the Natural Science Foundation of Jilin Province(20210101151JC).
文摘A gated service single vacation M/G/1 queue with setup and closedown periods,and different customer arrival rates,is studied in this paper.The probability generating function of the number of systems for customers who are at the initial moment of service period is analyzed by using a total probability theorem,and the stability condition of the system is obtained.The stationary distribution of the queue length is solved by the regeneration cycle method.The stochastic decomposition of queue length in the steady state is calculated,and the service cycle is obtained.Moreover,classified discussions are established in order to solve the steady-state distribution for the waiting time.The variation of system performance indicators with parameters is analyzed by performing numerical experiments.
文摘For different external cavity lengths, lasing wavelength variation of fiber grating external cavity semiconductor laser (FGECSL) with ambient temperature has been investigated theoretically, and the theoretical results are in agreement with reported experimental observations.