期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Projective synchronisation with non-delayed and delayed coupling in complex networks consisting of identical nodes and different nodes
1
作者 杜瑞瑾 董高高 +2 位作者 田立新 郑松 孙梅 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第7期113-122,共10页
This paper first investigates the projective synchronisation problem with non-delayed and delayed coupling between drive-response dynamical networks consisting of identical nodes and different nodes. Based on Lyapunov... This paper first investigates the projective synchronisation problem with non-delayed and delayed coupling between drive-response dynamical networks consisting of identical nodes and different nodes. Based on Lyapunov stability theory, several nonlinear controllers are applied to achieve the projective synchronisation between the drive-response dynamical networks; simultaneously the topological structure of the drive dynamical complex networks can be exactly identified. Moreover, numerical examples are presented to verify the feasibility and effectiveness of the theorems. 展开更多
关键词 adaptive projective synchronisation drive-response dynamical networks non-delayedand delayed coupling identical and different nodes
原文传递
Comprehensive Index Evaluation of the Cooling System with the Level Loop Thermosyphon System in Different Computing Hub Nodes in China
2
作者 Li Ling Danhao Song +2 位作者 Qianlong Hu Zihao Xiang Zeyu Zhang 《Energy Engineering》 2025年第8期3309-3328,共20页
Rack-level loop thermosyphons have been widely adopted as a solution to data centers’growing energy demands.While numerous studies have highlighted the heat transfer performance and energy-saving benefits of this sys... Rack-level loop thermosyphons have been widely adopted as a solution to data centers’growing energy demands.While numerous studies have highlighted the heat transfer performance and energy-saving benefits of this system,its economic feasibility,water usage effectiveness(WUE),and carbon usage effectiveness(CUE)remain underexplored.This study introduces a comprehensive evaluation index designed to assess the applicability of the rack-level loop thermosyphon system across various computing hub nodes.The air wet bulb temperature Ta,w was identified as the most significant factor influencing the variability in the combination of PUE,CUE,and WUE values.The results indicate that the rack-level loop thermosyphon system achieves the highest score in Lanzhou(94.485)and the lowest in Beijing(89.261)based on the comprehensive evaluation index.The overall ranking of cities according to the comprehensive evaluation score is as follows:Gansu hub(Lanzhou)>Inner Mongolia hub(Hohhot)>Ningxia hub(Yinchuan)>Yangtze River Delta hub(Shanghai)>Chengdu Chongqing hub(Chongqing)>Guangdong-Hong Kong-Macao Greater Bay Area hub(Guangzhou)>Guizhou hub(Guiyang)>Beijing-Tianjin-Hebei hub(Beijing).Furthermore,Hohhot,Lanzhou,and Yinchuan consistently rank among the top three cities for comprehensive scores across all load rates,while Guiyang(at a 25%load rate),Guangzhou(at a 50%load rate),and Beijing(at 75%and 100%load rates)exhibited the lowest comprehensive scores. 展开更多
关键词 Data center rack level loop thermosyphon different Computing hub node different load rates comprehensive indicator analysis
在线阅读 下载PDF
Rational Evaluation of Different Lymph Node Dissection.
3
《Chinese Medical Journal》 SCIE CAS CSCD 1995年第5期51-51,共1页
To evaluate the effect and indication of diffferent lymph node dissection(D.D.D),we performed radical operations for 371 cases of gastric cancer.The results showed that Dof Dlymph node dissection was enough for gast... To evaluate the effect and indication of diffferent lymph node dissection(D.D.D),we performed radical operations for 371 cases of gastric cancer.The results showed that Dof Dlymph node dissection was enough for gastric cancer of Ia stage, 展开更多
关键词 Rational Evaluation of different Lymph Node Dissection
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部