An experimental system based on the background-oriented schlieren(BOS) technique is built to reconstruct the density and temperature distribution of a flame-induced distorted flow field which has a density gradient....An experimental system based on the background-oriented schlieren(BOS) technique is built to reconstruct the density and temperature distribution of a flame-induced distorted flow field which has a density gradient. The cross-correlation algorithm with sub-pixel accuracy is introduced and used to calculate the background-element displacement of a disturbed image and a fourth-order difference scheme is also developed to solve the Poisson equation. An experiment for a disturbed flow field caused by a burning candle is performed to validate the built BOS system and the results indicate that density and temperature distribution of the disturbed flow field can be reconstructed accurately. A notable conclusion is that in order to make the reconstructed results have a satisfactory accuracy, the inquiry step length should be less than the size of the interrogation window.展开更多
The three-dimensional visualization model of human body duct is based on virtual anatomical structure reconstruction with duct angiography,which realizes virtual model transferred from two-dimensional,planar and stati...The three-dimensional visualization model of human body duct is based on virtual anatomical structure reconstruction with duct angiography,which realizes virtual model transferred from two-dimensional,planar and static images into three-dimensional,stereoscopic and dynamic ones repectively.In recent years,the multi-duct segmentation and division of the same specimen(or organ) is the focus of attention shared by surgeons and clinical anatomists.On the basis of 4.22 g/cm3 body bone density,this study has screened out metal oxide contract agent with different density for infusion and modeling,as well as compared and analyzed the effects of three-dimensional image of CT virtual bronchoscopy(CTVB),three-dimensional image of CT maximum intensity projection and three-dimensional model.This experiment result showed synchronously infusing multi-duct of same specimen(or organ) with contrast agent in different densities could reconstruct three-dimensional models of all ducts once only and adjust threshold to develop single or multiple ducts.It was easier to segment and observe the duct structure,anastomosis,directions and crossing in different parts,which was beyond comparison with three-dimensional image of CTVB.Although the existing three-dimensional duct reconstruction techniques still cannot be applied in living bodies temporarily,this study focused on a creative design of ducts segmentation in different density,which proposed a new experimental idea for developing multi-duct three-dimensional model in living body in the future.It will play a significant role in disease diagnosis and individual design in surgical treatment program.Therefore,this study observes the three-dimensional status of human duct with the application of contrast agent fillers in different density,combined with three-dimensional reconstruction technology.It provides an innovative idea and method for constructing three-dimensional model of digital multi-duct specimen,and the ultimate goal is to develop the digitized virtual human and precise medical treatment better and faster.展开更多
Postoperative tunnel enlargement has been frequently reported after anterior cruciate ligament(ACL)reconstruction.Interference screw,as a surgical implant in ACL reconstruction,may influence natural loading transmis...Postoperative tunnel enlargement has been frequently reported after anterior cruciate ligament(ACL)reconstruction.Interference screw,as a surgical implant in ACL reconstruction,may influence natural loading transmission and contribute to tunnel enlargement.The aims of this study are(1)to quantify the alteration of strain energy density(SED)distribution after the anatomic single-bundle ACL reconstruction;and(2)to characterize the influence of screw length and diameter on the degree of the SED alteration.A validated finite element model of human knee joint was used.The screw length ranging from 20 to 30 mm with screw diameter ranging from 7 to 9 mm were investigated.In the post-operative knee,the SED increased steeply at the extra-articular tunnel aperture under compressive and complex loadings,whereas the SED decreased beneath the screw shaft and nearby the intra-articular tunnel aperture.Increasing the screw length could lower the SED deprivation in the proximal part of the bone tunnel;whereas increasing either screw length or diameter could aggravate the SED deprivation in the distal part of the bone tunnel.Decreasing the elastic modulus of the screw could lower the bone SED deprivation around the screw.In consideration of both graft stability and SED alteration,a biodegradable interference screw with a long length is recommended,which could provide a beneficial mechanical environment at the distal part of the tunnel,and meanwhile decrease the bone-graft motion and synovial fluid propagation at the proximal part of the tunnel.These findings together with the clinical and histological factors could help to improve surgical outcome,and serve as a preliminary knowledge for the following study of biodegradable interference screw.展开更多
基金supported by the Key Program of the National Natural Science Foundation of China(Grant No.NSFC 91441205)
文摘An experimental system based on the background-oriented schlieren(BOS) technique is built to reconstruct the density and temperature distribution of a flame-induced distorted flow field which has a density gradient. The cross-correlation algorithm with sub-pixel accuracy is introduced and used to calculate the background-element displacement of a disturbed image and a fourth-order difference scheme is also developed to solve the Poisson equation. An experiment for a disturbed flow field caused by a burning candle is performed to validate the built BOS system and the results indicate that density and temperature distribution of the disturbed flow field can be reconstructed accurately. A notable conclusion is that in order to make the reconstructed results have a satisfactory accuracy, the inquiry step length should be less than the size of the interrogation window.
基金supported by Medical Scientific Research Funding Project of Guangdong Province,China(No.2014777)
文摘The three-dimensional visualization model of human body duct is based on virtual anatomical structure reconstruction with duct angiography,which realizes virtual model transferred from two-dimensional,planar and static images into three-dimensional,stereoscopic and dynamic ones repectively.In recent years,the multi-duct segmentation and division of the same specimen(or organ) is the focus of attention shared by surgeons and clinical anatomists.On the basis of 4.22 g/cm3 body bone density,this study has screened out metal oxide contract agent with different density for infusion and modeling,as well as compared and analyzed the effects of three-dimensional image of CT virtual bronchoscopy(CTVB),three-dimensional image of CT maximum intensity projection and three-dimensional model.This experiment result showed synchronously infusing multi-duct of same specimen(or organ) with contrast agent in different densities could reconstruct three-dimensional models of all ducts once only and adjust threshold to develop single or multiple ducts.It was easier to segment and observe the duct structure,anastomosis,directions and crossing in different parts,which was beyond comparison with three-dimensional image of CTVB.Although the existing three-dimensional duct reconstruction techniques still cannot be applied in living bodies temporarily,this study focused on a creative design of ducts segmentation in different density,which proposed a new experimental idea for developing multi-duct three-dimensional model in living body in the future.It will play a significant role in disease diagnosis and individual design in surgical treatment program.Therefore,this study observes the three-dimensional status of human duct with the application of contrast agent fillers in different density,combined with three-dimensional reconstruction technology.It provides an innovative idea and method for constructing three-dimensional model of digital multi-duct specimen,and the ultimate goal is to develop the digitized virtual human and precise medical treatment better and faster.
基金supported by the National Science & Technology Pillar Program of China(2012BAI18B07 and 2012BAI22B02)the National Natural Science Foundation of China(10925208 and 11120101001)the National Key Lab of Virtual Reality Technology
文摘Postoperative tunnel enlargement has been frequently reported after anterior cruciate ligament(ACL)reconstruction.Interference screw,as a surgical implant in ACL reconstruction,may influence natural loading transmission and contribute to tunnel enlargement.The aims of this study are(1)to quantify the alteration of strain energy density(SED)distribution after the anatomic single-bundle ACL reconstruction;and(2)to characterize the influence of screw length and diameter on the degree of the SED alteration.A validated finite element model of human knee joint was used.The screw length ranging from 20 to 30 mm with screw diameter ranging from 7 to 9 mm were investigated.In the post-operative knee,the SED increased steeply at the extra-articular tunnel aperture under compressive and complex loadings,whereas the SED decreased beneath the screw shaft and nearby the intra-articular tunnel aperture.Increasing the screw length could lower the SED deprivation in the proximal part of the bone tunnel;whereas increasing either screw length or diameter could aggravate the SED deprivation in the distal part of the bone tunnel.Decreasing the elastic modulus of the screw could lower the bone SED deprivation around the screw.In consideration of both graft stability and SED alteration,a biodegradable interference screw with a long length is recommended,which could provide a beneficial mechanical environment at the distal part of the tunnel,and meanwhile decrease the bone-graft motion and synovial fluid propagation at the proximal part of the tunnel.These findings together with the clinical and histological factors could help to improve surgical outcome,and serve as a preliminary knowledge for the following study of biodegradable interference screw.