期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Optimizing Contrast-Enhanced Magnetic Resonance Neurography of the Brachial Plexus With Delayed Scanning
1
作者 Jun Xu Xiaoli Hu +7 位作者 Xiaoyun Su Shen Gui Ziqiao Lei Xiaoming Liu Xiangzhi Zhou Lixia Wang Wenjun Wu Xiangchuang Kong 《iRADIOLOGY》 2025年第2期168-175,共8页
Background:Contrast-enhanced magnetic resonance neurography(ceMRN)can enhance brachial plexus visualization and quality of imaging.However,the interval between contrast injection and scanning that provides the highest... Background:Contrast-enhanced magnetic resonance neurography(ceMRN)can enhance brachial plexus visualization and quality of imaging.However,the interval between contrast injection and scanning that provides the highest-quality images is not known.Methods:Fifteen patients underwent brachial plexus imaging using the 3D T2-NerveView sequence with a scanning duration of 5 min.A consecutive six-phase scan was initiated immediately at the start of contrast agent injection.Subsequently,all patients'images were classified into six groups according to the phases:group A(phase 1,delay 0 min),group B(phase 2,delay 5 min),group C(phase 3,delay 10 min),group D(phase 4,delay 15 min),group E(phase 5,delay 20 min),and group F(phase 6,delay 25 min).The image quality in each group was assessed based on nerve signal(signalnerve),muscle signal(signalmuscle),lymph node signal(signallymph node),background noise(BN),signal-to-noise ratio(SNR),contrast-to-noise ratio(CNR),and subjective score.Results:Signalnerve,signalmuscle,BN,and SNR did not significantly differ among the six groups(p>0.05).However,significant differences(p<0.05)were observed in signallymph node(F=16.067),CNR(F=9.495),and subjective score(χ^(2)=23.586).As the scanning delay increased,signallymph node intensity gradually increased whereas the CNR gradually decreased.The subjective score was significantly higher in groups B(4.830.24),C(4.900.21),D(4.870.30),E(4.830.31),and F(4.830.31)than in group A(4.470.30).Conclusion:We recommend performing brachial plexus ceMRN 5 min after contrast injection.With this delay,the brachial plexus can be visualized optimally with minimal interference from background signals. 展开更多
关键词 brachial plexus compressed sensing delayed scanning image quality magnetic resonance neurography
暂未订购
Electro-optical sampling non-synchronous delay scanning measurement of electron beam bunch length at BFEL 被引量:1
2
作者 孙大睿 徐金强 陈森玉 《Chinese Physics C》 SCIE CAS CSCD 2010年第2期227-230,共4页
The Electro-optical sampling delay scanning technique can be used for electron beam bunch length measurement. A novel non-synchronous delay scanning technique based on the electro-optical sampling measurements is pres... The Electro-optical sampling delay scanning technique can be used for electron beam bunch length measurement. A novel non-synchronous delay scanning technique based on the electro-optical sampling measurements is presented. Based on Beijing Free Electron Laser (BFEL), the electron beam bunch length was measured with the electro-optical sampling technique for the first time in China. The result shows that the electron beam bunch length at BFEL is about 5.6±1.2 ps. 展开更多
关键词 electro-optical sampling measurement of electron beam bunch length non-synchronous delay scanning technique
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部