There is a growing discrepancy between the supply and demand of livers for transplantation resulting in high mortality rates on the waiting list. One of the options to decrease the mortality on the waiting list is to ...There is a growing discrepancy between the supply and demand of livers for transplantation resulting in high mortality rates on the waiting list. One of the options to decrease the mortality on the waiting list is to optimize organs with inferior quality that otherwise would be discarded. Livers from donation after cardiac death(DCD) donors are frequently discarded because they are exposed to additional warm ischemia time, and this might lead to primary-non-function, delayed graft function, or severe biliary complications. In order to maximize the usage of DCD livers several new preservation approaches have been proposed. Here, we will review 3 innovative organ preservation methods:(1) different ex vivo perfusion techniques;(2) persufflation with oxygen; and(3) addition of thrombolytic therapy. Improvement of the quality of DCD liver grafts could increase the pool of liver graft's for transplantation, improve the outcomes, and decrease the mortality on the waiting list.展开更多
In this paper, we propose an SEIR epidemic model with Logistic death rate of virus mutation. By means of the direct Lyapunov method and the LaSalle's Invariance Principle, the global stability of the disease-free ...In this paper, we propose an SEIR epidemic model with Logistic death rate of virus mutation. By means of the direct Lyapunov method and the LaSalle's Invariance Principle, the global stability of the disease-free equilibrium is proved. Using algebraic method to construct Lyapunov function, the global stability of the endemic equilibrium is proved. In addition, numerical simulations are done and the influence of parameters in the model on disease transmission is analyzed.展开更多
AIM: To test the methodical and pre-analytical performance of a new multiplex cancer biomarker panel using magnetic beads. METHODS: The MILLIPLEX? MAP Human Circulating Cancer Biomarker Magnetic Bead Panel 1 comprises...AIM: To test the methodical and pre-analytical performance of a new multiplex cancer biomarker panel using magnetic beads. METHODS: The MILLIPLEX? MAP Human Circulating Cancer Biomarker Magnetic Bead Panel 1 comprises the tumor markers carcinoembryonic antigen, alpha-fetoprotein, total prostate-specific antigen, cancer antigen 15-3, cancer antigen 19-9, cancer antigen 125, cytokeratine 19-fragment, β-human chorionic gonadotropin, human epididymis protein 4, osteopontin, prolactin, the cell death and angiogenesis markers soluble Fas, soluble Fas-ligand, tumor necrosis factor related apoptosisinducing ligand, vascular endothelial growth factor andthe immunological markers interleukin-6(IL-6), IL-8, tumor necrosis factor-α, transforming growth factor α, fibroblast growth factor-2, macrophage migration inhibitory factor, leptin, hepatocyte growth factor, and stem cell factor. We determined intra- and inter-assay imprecision as well as dilution linearity using quality controls and serum pools. Furthermore, the stability of the 24 biomarkers examined in this panel was ascertained by testing the influence of different storage temperatures and time span before centrifugation.RESULTS: For all markers measured in the synthetic internal quality controls, the intra-assay imprecision ranged between 2.26% and 9.41%, while for 20 of 24 measured markers in the physiological serum pools, it ranged between 1.68% and 12.87%. The inter-assay imprecision ranged between 1.48%-17.12% for 23 biomarkers in synthetic, and between 4.59%-23.88% for 18 biomarkers in physiological quality controls. Here, single markers with very low concentration levels had increased imprecision rates. Dilution linearity was acceptable(70%-130% recovery) for 20 biomarkers. Regarding pre-analytical influencing factors, most markers were stable if blood centrifugation was delayed or if serum was stored for up to 24 h at 4 ℃ and 25 ℃ after centrifugation. Comparable results were obtained in serum and plasma for most markers. However, great changes were observed for single markers.CONCLUSION: MILLIPLEX? MAP Human Circulating Cancer Biomarker Magnetic Bead Panel 1 assay is a stable and precise method for detection of most biomarkers included in the kit. However, single markers have to be interpreted with care.展开更多
Aim: To identify evidence in the literature on the significance of death conferences for nurses. Method: This is an integrative literature review, consisting of scientific articles published on “Ichushi-Web”, an Int...Aim: To identify evidence in the literature on the significance of death conferences for nurses. Method: This is an integrative literature review, consisting of scientific articles published on “Ichushi-Web”, an Internet-based retrieval service by the Japan Medical Abstracts Society (JAMAS), PubMed, Medline, Cochrane library, and Google Scholar for ‘the whole year,’ combining the keywords “death conference”, “nurse”, and “KJ method”. The significance of death conferences was reviewed by comparison of prior qualitative studies analyzed by the KJ method. Result: Seven studies, all from Japanese, were identified. The significance of death conferences showed “refraction”, “cooperation”, “directionality of nursing”, “caring for patient”, “caring for family”, “specific methods of nursing”, and “feelings of nurses”. Conclusion: The significance of death conferences is considered to be the effect on nurses for amelioration in the quality of patient and family care, development of human relations, and growth as a nurse. The quality of death conferences should be enhanced based on the guidelines for its clear definition.展开更多
Residual stresses can have a strong effect on the usability of machined parts,and the X-ray diffraction(XRD)measuring equipment,which is commonly used to measure residual stresses,is very expensive.This paper presents...Residual stresses can have a strong effect on the usability of machined parts,and the X-ray diffraction(XRD)measuring equipment,which is commonly used to measure residual stresses,is very expensive.This paper presents a method of measuring the residual stresses induced by boring in the internal surface of a tube with much cheaper equipment.The method,called the strain-based method is mainly based on the strains measured on the external surface of the tube.It is proposed on the basis of the very long tube assumption.The finite element method(FEM)analysis is thus used to validate the length of the tube.Guided by the FEM results,an appropriate length of the tube is chosen,and the residual stresses are obtained from both the strain-based method and the XRD method.Stress profiles obtained from both two methods are compared.The comparison result indicates that the profiles of the two methods agree well with each other.Therefore,it can be concluded that the accuracy of the strain-based method is high enough,and it can be applied to residual stress measurement in practice.展开更多
基金Supported by University of Massachusetts(FDSP grant to Paulo N Martins)
文摘There is a growing discrepancy between the supply and demand of livers for transplantation resulting in high mortality rates on the waiting list. One of the options to decrease the mortality on the waiting list is to optimize organs with inferior quality that otherwise would be discarded. Livers from donation after cardiac death(DCD) donors are frequently discarded because they are exposed to additional warm ischemia time, and this might lead to primary-non-function, delayed graft function, or severe biliary complications. In order to maximize the usage of DCD livers several new preservation approaches have been proposed. Here, we will review 3 innovative organ preservation methods:(1) different ex vivo perfusion techniques;(2) persufflation with oxygen; and(3) addition of thrombolytic therapy. Improvement of the quality of DCD liver grafts could increase the pool of liver graft's for transplantation, improve the outcomes, and decrease the mortality on the waiting list.
基金Supported by the Natural Science Basic Research Plan of Shaanxi Province(Grant Nos.2018JM1011 2017JQ1014)the National Natural Science Foundation of China(Grant No.11701041)
文摘In this paper, we propose an SEIR epidemic model with Logistic death rate of virus mutation. By means of the direct Lyapunov method and the LaSalle's Invariance Principle, the global stability of the disease-free equilibrium is proved. Using algebraic method to construct Lyapunov function, the global stability of the endemic equilibrium is proved. In addition, numerical simulations are done and the influence of parameters in the model on disease transmission is analyzed.
文摘AIM: To test the methodical and pre-analytical performance of a new multiplex cancer biomarker panel using magnetic beads. METHODS: The MILLIPLEX? MAP Human Circulating Cancer Biomarker Magnetic Bead Panel 1 comprises the tumor markers carcinoembryonic antigen, alpha-fetoprotein, total prostate-specific antigen, cancer antigen 15-3, cancer antigen 19-9, cancer antigen 125, cytokeratine 19-fragment, β-human chorionic gonadotropin, human epididymis protein 4, osteopontin, prolactin, the cell death and angiogenesis markers soluble Fas, soluble Fas-ligand, tumor necrosis factor related apoptosisinducing ligand, vascular endothelial growth factor andthe immunological markers interleukin-6(IL-6), IL-8, tumor necrosis factor-α, transforming growth factor α, fibroblast growth factor-2, macrophage migration inhibitory factor, leptin, hepatocyte growth factor, and stem cell factor. We determined intra- and inter-assay imprecision as well as dilution linearity using quality controls and serum pools. Furthermore, the stability of the 24 biomarkers examined in this panel was ascertained by testing the influence of different storage temperatures and time span before centrifugation.RESULTS: For all markers measured in the synthetic internal quality controls, the intra-assay imprecision ranged between 2.26% and 9.41%, while for 20 of 24 measured markers in the physiological serum pools, it ranged between 1.68% and 12.87%. The inter-assay imprecision ranged between 1.48%-17.12% for 23 biomarkers in synthetic, and between 4.59%-23.88% for 18 biomarkers in physiological quality controls. Here, single markers with very low concentration levels had increased imprecision rates. Dilution linearity was acceptable(70%-130% recovery) for 20 biomarkers. Regarding pre-analytical influencing factors, most markers were stable if blood centrifugation was delayed or if serum was stored for up to 24 h at 4 ℃ and 25 ℃ after centrifugation. Comparable results were obtained in serum and plasma for most markers. However, great changes were observed for single markers.CONCLUSION: MILLIPLEX? MAP Human Circulating Cancer Biomarker Magnetic Bead Panel 1 assay is a stable and precise method for detection of most biomarkers included in the kit. However, single markers have to be interpreted with care.
文摘Aim: To identify evidence in the literature on the significance of death conferences for nurses. Method: This is an integrative literature review, consisting of scientific articles published on “Ichushi-Web”, an Internet-based retrieval service by the Japan Medical Abstracts Society (JAMAS), PubMed, Medline, Cochrane library, and Google Scholar for ‘the whole year,’ combining the keywords “death conference”, “nurse”, and “KJ method”. The significance of death conferences was reviewed by comparison of prior qualitative studies analyzed by the KJ method. Result: Seven studies, all from Japanese, were identified. The significance of death conferences showed “refraction”, “cooperation”, “directionality of nursing”, “caring for patient”, “caring for family”, “specific methods of nursing”, and “feelings of nurses”. Conclusion: The significance of death conferences is considered to be the effect on nurses for amelioration in the quality of patient and family care, development of human relations, and growth as a nurse. The quality of death conferences should be enhanced based on the guidelines for its clear definition.
基金Supported by the National Defense Program of China(C152012C002)the Specialized Research Fund for the Doctoral Program of Higher Education of China(20123218120025)
文摘Residual stresses can have a strong effect on the usability of machined parts,and the X-ray diffraction(XRD)measuring equipment,which is commonly used to measure residual stresses,is very expensive.This paper presents a method of measuring the residual stresses induced by boring in the internal surface of a tube with much cheaper equipment.The method,called the strain-based method is mainly based on the strains measured on the external surface of the tube.It is proposed on the basis of the very long tube assumption.The finite element method(FEM)analysis is thus used to validate the length of the tube.Guided by the FEM results,an appropriate length of the tube is chosen,and the residual stresses are obtained from both the strain-based method and the XRD method.Stress profiles obtained from both two methods are compared.The comparison result indicates that the profiles of the two methods agree well with each other.Therefore,it can be concluded that the accuracy of the strain-based method is high enough,and it can be applied to residual stress measurement in practice.