Undesired ice accumulation on infrastructure and transportation systems leads to catastrophic events and significant economic losses.Although various anti-icing surfaces with photothermal effects can initially prevent...Undesired ice accumulation on infrastructure and transportation systems leads to catastrophic events and significant economic losses.Although various anti-icing surfaces with photothermal effects can initially prevent icing,any thawy droplets remaining on the horizontal surface can quickly re-freezing once the light diminishes.To address these challenges,we have developed a self-draining slippery surface(SDSS)that enables the thawy droplets to self-remove on the horizontal surface,thereby facilitating real-time anti-icing with the aid of sunlight(100 m W cm^(-2)).This is achieved by sandwiching a thin pyroelectric layer between slippery surface and photothermal film.Due to the synergy between the photothermal and pyroelectric layers,the SDSS not only maintains a high surface temperature of 19.8±2.2℃at the low temperature(-20.0±1.0℃),but also generates amount of charge through thermoelectric coupling.Thus,as cold droplets dropped on the SDSS,electrostatic force pushes the droplets off the charged surface because of the charge transfer mechanism.Even if the surface freezes overnight,the ice can melt and drain off the SDSS within 10 min of exposure to sunlight at-20.0±1.0℃,leaving a clean surface.This work provides a new perspective on the anti-icing system in the real-world environments.展开更多
Low-density short-duration pulsed current-assisted aging treatment was applied to the Ti-6Al-4V-0.5Mo-0.5Zr alloy subjected to different solution treatments.The results show that numerous α_(p) phases redissolve into...Low-density short-duration pulsed current-assisted aging treatment was applied to the Ti-6Al-4V-0.5Mo-0.5Zr alloy subjected to different solution treatments.The results show that numerous α_(p) phases redissolve into the new β phase during the pulsed current-assisted aging process,and then the newly formed β phase is mainly transformed into the β_(t) phase,with occasional transition to new α_(p) phase,leading to a remarkable grain refinement,especially for the lamellarαs phases.In comparison to conventional aging treatment,the pulsed current-assisted aging approach achieves a significant enhancement in strength without degrading ductility,yielding an excellent mechanical property combination:a yield strength of 932 MPa,a tensile strength of 1042 MPa,and an elongation of 12.2%.It is primarily ascribed to the increased fraction of β_(t) phases,the obvious grain refinement effect,and the slip block effect induced by the multiple-variantαs colonies distributed within β_(t) phases.展开更多
This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper cons...This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper constructs an internal model to learn the information of the states and input of the grid-connected inverter under steady state.Second,by utilizing the internal model principle,the paper turns the tracking control problem into the robust stabilization control problem based on some appropriate coordinate transformations.Then,The paper designs a dynamics state feedback control law to deal with this robust stabilization problem,and thus the solution of the robust current tracking control problem of three-phase grid-connected inverters can be obtained.This control method can ensure the asymptotic stability of the closedloop system.Finally,the paper illustrates the effectiveness of the proposed control approach through several groups of simulations,and compares it with the feedforward control method to verify the robustness of the proposed control method to uncertain parameters.展开更多
To elucidate the accelerated degradation mechanisms of metallic interconnects in operational solid oxide fuel cells,the oxidation behavior of FSS430 ferritic stainless steel under the coupling of simultaneous electric...To elucidate the accelerated degradation mechanisms of metallic interconnects in operational solid oxide fuel cells,the oxidation behavior of FSS430 ferritic stainless steel under the coupling of simultaneous electrical current and high-temperature exposure is investigated.Isothermal thermogravimetric analysis was employed to quantify oxidation kinetics,complemented by microstructural characterization using X-ray diffraction,scanning electron microscopy with energy-dispersive spectroscopy and transmission electron microscopy.Experimental results demonstrate that the applied current dramatically enhances oxidation rates,increasing specific mass gain from 0.25 mg/cm^(2)(0 A/cm^(2))to 5.20 mg/cm^(2)(0.2 A/cm^(2))and oxide scale thickness from 1.87 to 15.62μm after 200 h.This acceleration originates from current-induced electromigration forces that promote cationic transport through the oxide layer.The quantitative relationships between current density and oxidation parameters are established,enabling predictive modeling of interconnector degradation in solid oxide fuel cell(SOFC)systems.展开更多
Exercise produces a decrease in pain sensitivity via an effect called exercise-induced hypoalgesia(EIH).Transcranial direct current stimulation(tDCS),acting on similar analgesic mechanisms as EIH,represents a potentia...Exercise produces a decrease in pain sensitivity via an effect called exercise-induced hypoalgesia(EIH).Transcranial direct current stimulation(tDCS),acting on similar analgesic mechanisms as EIH,represents a potential complementary intervention that may amplify the effects of exercise on pain.This study aimed to explore if anodal tDCS could enhance the effect of exercise on pain compared to exercise alone.A total of 35 healthy participants aged 19–37 years completed a familiarisation session followed by two separate sessions where active and sham tDCS was applied in a randomised cross-over design.The familiarisation session involved familiarisation to the pain assessment and exercise tasks,while the subsequent tDCS sessions involved pain sensitivity assessment,exercise and either anodal tDCS or sham tDCS.tDCS doses were applied at 2 mA over the primary motor cortex for 10 min,with the reference electrode placed over the contralateral supraorbital area.The exercise task involved a sustained isometric grip strength contraction at 35%of maximal voluntary contraction(MVC)until volitional exhaustion.Pain sensitivity was evaluated as pressure pain threshold before tDCS,after tDCS,and after exercise.Across both tDCS conditions,pain threshold was higher after exercise when compared to pre-and post-tDCS measurement.This increase in pain threshold did not differ between active and sham tDCS conditions.Our findings suggest that the hypoalgesic effects of active anodal tDCS over the motor cortex prior to exercise are no greater than the effects of sham tDCS prior to exercise.展开更多
To address the issues of high costs and low component utilization caused by the independent configuration of hybrid DC circuit breakers(HCBs)and DC power flow controllers(DCPFCs)at each port in existing DC distributio...To address the issues of high costs and low component utilization caused by the independent configuration of hybrid DC circuit breakers(HCBs)and DC power flow controllers(DCPFCs)at each port in existing DC distribution networks,this paper adopts a component sharing mechanism to propose a composite multi-port hybrid DC circuit breaker(CM-HCB)with DC power flow and fault current limitation abilities,as well as reduced component costs.The proposed CM-HCB topology enables the sharing of the main breaker branch(MB)and the energy dissipation branch,while the load commutation switches(LCSs)in the main branch are reused as power flow control components,enabling flexible regulation of power flow in multiple lines.Meanwhile,by reconstructing the current path during the fault process,the proposed CM-HCB can utilize the internal coupled inductor to limit the current rise rate at the initial stage of the fault,significantly reducing the requirement for breaking current.A detailed study on the topological structure,steady-state power flow regulation mechanism,transient fault isolation mechanism,control strategy and characteristic analysis of the proposed CM-HCB is presented.Then,a Matlab/Simulink-based meshed three-terminal DC grid simulation platform with the proposed CM-HCB is built.The results indicate that the proposed CM-HCB can not only achieve flexible power flow control during steady-state operation,but also obtain current rise limitation and fault isolation abilities under short-circuit fault conditions,verifying its correctness and effectiveness.Finally,a comparative economic analysis is conducted between the proposed CM-HCB and the other two existing solutions,confirming that its component sharing mechanism can significantly reduce the number of components,lower system costs,and improve component utilization.展开更多
Pavement snow and icing are worldwide problems, but effective countermeasures are just beginning to be developed in China. The two most common snow and ice removal methods are mechanical clearance and chemical melting...Pavement snow and icing are worldwide problems, but effective countermeasures are just beginning to be developed in China. The two most common snow and ice removal methods are mechanical clearance and chemical melting, and the advantages and disadvantages of each approach are discussed here, including environmental and structural damage caused by corrosive snow melting agents. New developments in chemical melting agents and mechanical equipment are discussed, and an overview of alternative thermal melting systems is presented, including the use of geothermy and non-geothermal heating systems utilizing solar energy, electricity, conductive pavement materials, and infrared/microwave applications. Strategic recommendations are made for continued enhancement of public safety in snow and ice conditions.展开更多
De-icing technology has become an increasingly important subject in numerous applications in recent years.However,the direct numerical modeling and simulation the physical process of thermomechanical deicing is limite...De-icing technology has become an increasingly important subject in numerous applications in recent years.However,the direct numerical modeling and simulation the physical process of thermomechanical deicing is limited.This work is focusing on developing a numerical model and tool to direct simulate the de-icing process in the framework of the coupled thermo-mechanical peridynamics theory.Here,we adopted the fully coupled thermo-mechanical bond-based peridynamics(TM-BB-PD)method for modeling and simulation of de-icing.Within the framework of TM-BB-PD,the ice constitutive model is established by considering the influence of the temperature difference between two material points,and a modified failure criteria is proposed,which takes into account temperature effect to predict the damage of quasi-brittle ice material.Moreover,thermal boundary condition is used to simulate the thermal load in the de-icing process.By comparing with the experimental results and the previous reported finite element modeling,our numerical model shows good agreement with the previous predictions.Based on the numerical results,we find that the developed method can not only predict crack initiation and propagation in the ice,but also predict the temperature distribution and heat conduction during the de-icing process.Furthermore,the influence of the temperature for the ice crack growth pattern is discussed accordingly.In conclusion,the coupled thermal-mechanical peridynamics formulation with modified failure criterion is capable of providing a modeling tool for engineering applications of de-icing technology.展开更多
This paper proposes a numerical method to analyze the ice protection capability and predict the power requirements of a piezoelectric resonant de-icing system.The method is based on a coupled electro-mechanical finite...This paper proposes a numerical method to analyze the ice protection capability and predict the power requirements of a piezoelectric resonant de-icing system.The method is based on a coupled electro-mechanical finite element analysis which enables the fast computation of the modes of resonance of interest to de-ice curved surfaces and the estimation of the input voltage and current required for a given configuration(defined by its mode,actuator location,ice deposit,etc.).Eventually,the electric power to be supplied can be also assessed.The method is applied to a NACA 0024 leading edge equipped with piezoelectric actuators.First,two extension modes are analyzed and compared with respect to their efficiency and power requirements.Then,tests are carried out in an icing tunnel to verify the effectiveness of the piezoelectric ice protection system and the predictions of the maximal required power.The system allows de-icing the leading edge in less than 2 s for a glaze ice deposit.展开更多
In order to prevent severe pollution by de-icing salt on greenery along urban roads, a half lethal dose (LD_50)for a plant population was confirmed through stress simulation of chloride de-icing salt on Euonymus jap...In order to prevent severe pollution by de-icing salt on greenery along urban roads, a half lethal dose (LD_50)for a plant population was confirmed through stress simulation of chloride de-icing salt on Euonymus japonicus, with an ianalysis of physiological changes, statistics on mortality rate on plant populations and mathematic modeling during a 30- day subacute toxicity test. The results indicate that a significant positive correlation in the early stages and a significant negative correlation in the later stages were observed between the amount of chlorophyll a and b in plants and a cumulative dose of de-icing salt. The amounts of free proline in plants and the dose of de-icing salt were positively correlated Over the entire period. No significant correlation in the initial stage, but a significant negative correlation in later stages was observed between the soluble protein and the dose of de-icing salt. LDs0 of this chloride agent on E. japonicus is 5 kg.(L·m2)-1 over 30 days.展开更多
Since flight accidents due to aircraft icing occur from time to time,this paper proposes an array of impact rod-type plasma synthetic jet de-icing methods for aircraft icing problems.The impact rod-type plasma synthet...Since flight accidents due to aircraft icing occur from time to time,this paper proposes an array of impact rod-type plasma synthetic jet de-icing methods for aircraft icing problems.The impact rod-type plasma synthetic jet actuator(PSJA)is based on the traditional PSJA with an additional impact rod structure for better de-icing in the flight environment.In this work,we first optimize the ice-breaking performance of a single-impact rod-type PSJA,and then conduct an array of impact rod-type plasma synthetic jet ice-breaking experiments to investigate the relationship between crack expansion and discharge energy,ice thickness and group spacing.The results show that the impact force and impulse of a single-impact rod-type PSJA are proportional to the discharge energy,and there exists a threshold energy Qmin for a single actuator to break the ice,which is proportional to the ice thickness.Only when the discharge energy reaches above Qmin can the ice layer produce cracks,and at the same time,the maximum radial crack length produced during the ice-breaking process is proportional to the discharge energy.When the ice is broken by an array of impact rod PSJAs,the discharge energy and group spacing together determine whether the crack can be extended to the middle region of the actuator.When the group spacing is certain,increasing the energy can increase the intersection of cracks in the middle region,and the ice-fragmentation degree is increased and the ice-breaking effect is better.At the same time,the energy estimation method of ice breaking by an array of impact rod-type PSJAs is proposed according to the law when a single actuator is breaking ice.展开更多
The multi-terminal direct current(DC)grid has extinctive superiorities over the traditional alternating current system in integrating large-scale renewable energy.Both the DC circuit breaker(DCCB)and the current flow ...The multi-terminal direct current(DC)grid has extinctive superiorities over the traditional alternating current system in integrating large-scale renewable energy.Both the DC circuit breaker(DCCB)and the current flow controller(CFC)are demanded to ensure the multiterminal DC grid to operates reliably and flexibly.However,since the CFC and the DCCB are all based on fully controlled semiconductor switches(e.g.,insulated gate bipolar transistor,integrated gate commutated thyristor,etc.),their separation configuration in the multiterminal DC grid will lead to unaffordable implementation costs and conduction power losses.To solve these problems,integrated equipment with both current flow control and fault isolation abilities is proposed,which shares the expensive and duplicated components of CFCs and DCCBs among adjacent lines.In addition,the complicated coordination control of CFCs and DCCBs can be avoided by adopting the integrated equipment in themultiterminal DC grid.In order to examine the current flow control and fault isolation abilities of the integrated equipment,the simulation model of a specific meshed four-terminal DC grid is constructed in the PSCAD/EMTDC software.Finally,the comparison between the integrated equipment and the separate solution is presented a specific result or conclusion needs to be added to the abstract.展开更多
This paper presents a self-structured organizing single-input control system based on differentiable cerebellar model articulation controller (CMAC) for an n-link robot manipulator to achieve the high-precision positi...This paper presents a self-structured organizing single-input control system based on differentiable cerebellar model articulation controller (CMAC) for an n-link robot manipulator to achieve the high-precision position tracking. In the proposed scheme, the single-input CMAC controller is solely used to control the plant, so the input space dimension of CMAC can be simplified and no conventional controller is needed. The structure of single-input CMAC will also be self-organized;that is, the layers of single-input CMAC will grow or prune systematically and their receptive functions can be automatically adjusted. The online tuning laws of single-input CMAC parameters are derived in gradient-descent learning method and the discrete-type Lyapunov function is applied to determine the learning rates of the proposed control system so that the stability of the system can be guaranteed. The simulation results of three-link De-icing robot manipulator are provided to verify the effectiveness of the proposed control methodology.展开更多
Advanced OER/HER electrocatalytic alternatives are crucial for the wide adaptation of green hydrogen energy.Herein,Ru/NiMnB spherical cluster pillar(SCP),denoted as Ru/NiMnB,is synthesized using a combination of elect...Advanced OER/HER electrocatalytic alternatives are crucial for the wide adaptation of green hydrogen energy.Herein,Ru/NiMnB spherical cluster pillar(SCP),denoted as Ru/NiMnB,is synthesized using a combination of electro-deposition and hydrothermal reaction.Systematic investigation of Ru doping in the NiMnB matrix revealed significant improvements in electrocatalytic performance.The Ru/NiMnB SCPs demonstrate superior OER/HER activity with low overpotentials of 150 and 103 mV at 50mA/cm^(2)in 1 M KOH,making them highly competitive with state-of-the-art electrocatalysts.Remarkably,the Ru/NiMnB SCPs exhibit a low 2-E cell voltage of 2.80 V at ultra-high current density of 2,000 m A/cm^(2)in 1 M KOH,outperforming the standard benchmark electrodes of RuO_(2)||Pt/C,thereby positioning Ru/NiMnB as one of the best bifunctional electrocatalysts.These SCPs exhibit exceptional high-current characteristics,stability and corrosion resistance,as evidenced by continuous operation at 1,000 mA/cm^(2)high-current density for over 150 h in 6 M KOH at elevated temperatures under harsh industrial conditions.Only a small amount of Ru incorporation significantly enhances the electrocatalytic performances of NiMnB,attributed to increased active sites and improved intrinsic properties such as conductivity,adsorption/desorption capability and reaction rates.Consequently,Ru/NiMnB SCPs present a promising bi-functional electrode concept for efficient green H_(2)production.展开更多
This work demonstrates experimentally the close relation between return currents from relativistic laser-driven target polarization and the quality of the relativistic laser–plasma interaction for laser-driven second...This work demonstrates experimentally the close relation between return currents from relativistic laser-driven target polarization and the quality of the relativistic laser–plasma interaction for laser-driven secondary sources,taking as an example ion acceleration by target normal sheath acceleration.The Pearson linear correlation of maximum return current amplitude and proton spectrum cutoff energy is found to be in the range from~0.70 to 0.94.kA-scale return currents rise in all interaction schemes where targets of any kind are charged by escaping laser-accelerated relativistic electrons.Their precise measurement is demonstrated using an inductive scheme that allows operation at high repetition rates.Thus,return currents can be used as a metrological online tool for the optimization of many laser-driven secondary sources and for diagnosing their stability.In particular,in two parametric studies of laser-driven ion acceleration,we carry out a noninvasive online measurement of return currents in a tape target system irradiated by the 1 PW VEGA-3 laser at Centro de Láseres Pulsados:first the size of the irradiated area is varied at best compression of the laser pulse;second,the pulse duration is varied by means of induced group delay dispersion at best focus.This work paves the way to the development of feedback systems that operate at the high repetition rates of PW-class lasers.展开更多
BACKGROUND Diabetic gastroparesis(DGP)disrupts gastric motility.Electroacupuncture(EA)at Zusanli(ST36)may alleviate DGP symptoms via neural pathways.AIM To investigate how EA current intensities at ST36 regulate neura...BACKGROUND Diabetic gastroparesis(DGP)disrupts gastric motility.Electroacupuncture(EA)at Zusanli(ST36)may alleviate DGP symptoms via neural pathways.AIM To investigate how EA current intensities at ST36 regulate neural pathways and improve gastric motility in DGP models.METHODS A DGP model was established using intraperitoneal injection of streptozotocin.Gastrointestinal motility was measured in rats after 2 weeks of continuous EA at ST36.Current intensity was selected as 0.5 mA,1 mA,and 3 mA.Gastric electrodynamics were detected by recording and analyzing the number of gastric discharges.The gastric emptying rate and propulsion rate of the small intestine were measured to assess dynamic gastrointestinal function.Hematoxylin-eosin staining was conducted to measure histopathological changes in the gastric sinus.Reverse transcription-polymerase chain reaction was conducted to determine mRNA levels of Rho guanine nucleotide-binding protein A and Rho-associated coiled-coil forming protein kinase.Western blotting was conducted to determine the expression levels of choline acetyltransferase,tyrosine hydroxylase,Rho guanine nucleotide-binding protein A,and Rho-associated coiled-coil forming protein kinase.Immunofluorescence staining in the stomach was conducted to detect the distribution of C-kit,an interstitial cell of Cajal marker.An enzymelinked immunosorbent assay was conducted to detect serum levels of acetylcholine and norepinephrine.RESULTS Treatment with EA improved gastric emptying and gastric smooth muscle disorders in rats with DGP,mitigated pathological damage,and restored the function of interstitial cells of Cajal.In addition,different current intensities of EA affected gastrointestinal function of rats with DGP.The 0.5 mA,1 mA,and 3 mA EA groups all improved gastrointestinal function.0.5 mA EA increased acetylcholine levels by increasing protein expression of choline acetyltransferase(P<0.05),thereby upregulating vagus nerve activity and enhancing parasympathetic nerve regulation.3 mA EA increased norepinephrine levels(P<0.05)by increasing protein expression of tyrosine hydroxylase,thereby activating the sympathetic nervous pathway.1 mA coordinated the function of the vagus and sympathetic nerves to improve gastrointestinal motility.CONCLUSION EA with ST36 improved gastric motility in rats with DGP.0.5 mA EA activated the vagus nerve,while 3 mA EA regulated gastrointestinal motility by activating the sympathetic nerves.展开更多
Accurate modeling of Earth's ionospheric F-region currents is essential for refining geomagnetic field models and understanding magnetosphere-ionosphere coupling.In this study,we develop averaged models to charact...Accurate modeling of Earth's ionospheric F-region currents is essential for refining geomagnetic field models and understanding magnetosphere-ionosphere coupling.In this study,we develop averaged models to characterize F-region currents using magnetic data from the MSS-1(Macao Science Satellite-1) and Swarm satellite missions.Our approach employs a toroidal field representation,utilizing spherical harmonics to capture spatial variations and Fourier series to represent temporal dynamics.Two models,Model-A and Model-B,derived from distinct datasets,are constructed to represent current patterns at altitudes of 450 km and 512 km,respectively.Our models successfully capture the primary spatial structures and seasonal variations of polar field-aligned currents.Additionally,they accurately reproduce the localized inter-hemispheric field-aligned currents observed in mid and low latitudes during solstices,particularly between 14:00 and 16:00 magnetic local times.These findings enhance our understanding of ionospheric F-region currents and contribute to more precise geomagnetic field modeling.展开更多
Non-metallic inclusions in steel are a significant challenge,affecting material properties and leading to issues such as stress concentration,cracking,and accelerated corrosion.Current methods for removing inclusions,...Non-metallic inclusions in steel are a significant challenge,affecting material properties and leading to issues such as stress concentration,cracking,and accelerated corrosion.Current methods for removing inclusions,including bubble,electromagnetic stirring,filtration separation,fluid flow,and sedimentation,often struggle with the removal of fine inclusions.Apart from these known methods,pulsed electric current(PEC),as an emerging technology,has demonstrated immense potential and environmental advantages.PEC offers adjustable current parameters and simple equipment,making it an attractive alternative to traditional methods.Its green energy-saving features and excellent results in regulating inclusion morphology and migration,as well as inhibiting submerged entry nozzle(SEN)clogging,make it a promising technology.In comparison to continuous current technology,PEC has shown significant advantages in regulating inclusions,not only improving purification efficiency but also demonstrating outstanding performance in flow stability and energy consumption.The ability of PEC to efficiently reduce inclusion numbers enhances the purity and quality of molten steel,improving its mechanical properties.Currently,the theoretical basis for controlling the movement of inclusions by current is mainly composed of three major theories:the double electric layer theory,electromagnetic force reverse separation theory,and electric free energy drive theory.These theories together form an important framework for researchers to understand and optimize the behavior of impurity movement controlled by electric current.Looking ahead,PEC is expected to pave the way for new solutions in directional regulation of inclusion migration,efficient inclusion removal,SEN clogging prevention,and the purification of molten steel.展开更多
The phase-locked loop(PLL)plays an essential role for synchronizing renewable power generation to the grid.However,as per the grid-code compliance for reactive current support,the PLL output frequency fluctuates signi...The phase-locked loop(PLL)plays an essential role for synchronizing renewable power generation to the grid.However,as per the grid-code compliance for reactive current support,the PLL output frequency fluctuates significantly and exceeds the limitation,which seriously threaten the safe supply of electricity.In this paper,the underlying theoretical mechanism and dominant force behind the maximum PLL frequency deviation are revealed.Accordingly,two feasible approaches are proposed to enhance the PLL frequency stability with validations in experimental results.展开更多
Micron-sized silicon(μSi)is a promising anode material for next-generation lithium-ion batteries due to its high specific capacity,low cost,and abundant reserves.However,the volume expansion that occurs during cyclin...Micron-sized silicon(μSi)is a promising anode material for next-generation lithium-ion batteries due to its high specific capacity,low cost,and abundant reserves.However,the volume expansion that occurs during cycling leads to the accumulation of undesirable stresses,resulting in pulverization of silicon microparticles and shortened lifespan of the batteries.Herein,a composite film of Cu-PET-Cu is proposed as the current collector(CC)forμSi anodes to replace the conventional Cu CC.Cu-PET-Cu CC is prepared by depositing Cu on both sides of a polyethylene terephthalate(PET)film.The PET layer promises good ductility of the film,permitting the Cu-PET-Cu CC to accommodate the volumetric changes of silicon microparticles and facilitates the stress release through ductile deformation.As a result,theμSi electrode with Cu-PET-Cu CC retains a high specific capacity of 2181 mA h g^(-1),whereas theμSi electrode with Cu CC(μSi/Cu)exhibits a specific capacity of 1285 mA h g^(-1)after 80 cycles.The stress relieving effect of CuPET-Cu was demonstrated by in-situ fiber optic stress monitoring and multi-physics simulations.This work proposes an effective stress relief strategy at the electrode level for the practical implementation ofμSi anodes.展开更多
基金supported by the National Natural Science Foundation of China(52273101,51922018,and 21875011)the Fundamental Research Funds for the Central Universities(KG21015201 and KG21020801)China Postdoctoral Science Foundation(2025M77422)。
文摘Undesired ice accumulation on infrastructure and transportation systems leads to catastrophic events and significant economic losses.Although various anti-icing surfaces with photothermal effects can initially prevent icing,any thawy droplets remaining on the horizontal surface can quickly re-freezing once the light diminishes.To address these challenges,we have developed a self-draining slippery surface(SDSS)that enables the thawy droplets to self-remove on the horizontal surface,thereby facilitating real-time anti-icing with the aid of sunlight(100 m W cm^(-2)).This is achieved by sandwiching a thin pyroelectric layer between slippery surface and photothermal film.Due to the synergy between the photothermal and pyroelectric layers,the SDSS not only maintains a high surface temperature of 19.8±2.2℃at the low temperature(-20.0±1.0℃),but also generates amount of charge through thermoelectric coupling.Thus,as cold droplets dropped on the SDSS,electrostatic force pushes the droplets off the charged surface because of the charge transfer mechanism.Even if the surface freezes overnight,the ice can melt and drain off the SDSS within 10 min of exposure to sunlight at-20.0±1.0℃,leaving a clean surface.This work provides a new perspective on the anti-icing system in the real-world environments.
基金National Key Research and Development Program of China(2021YFB3700801)。
文摘Low-density short-duration pulsed current-assisted aging treatment was applied to the Ti-6Al-4V-0.5Mo-0.5Zr alloy subjected to different solution treatments.The results show that numerous α_(p) phases redissolve into the new β phase during the pulsed current-assisted aging process,and then the newly formed β phase is mainly transformed into the β_(t) phase,with occasional transition to new α_(p) phase,leading to a remarkable grain refinement,especially for the lamellarαs phases.In comparison to conventional aging treatment,the pulsed current-assisted aging approach achieves a significant enhancement in strength without degrading ductility,yielding an excellent mechanical property combination:a yield strength of 932 MPa,a tensile strength of 1042 MPa,and an elongation of 12.2%.It is primarily ascribed to the increased fraction of β_(t) phases,the obvious grain refinement effect,and the slip block effect induced by the multiple-variantαs colonies distributed within β_(t) phases.
基金Supported by the Fundamental Research Funds for the Central Universities(2024ZYGXZR047)the National Natural Science Foundation of China(62373156)the Guangdong Basic and Applied Basic Research Foundation(2024A1515011736)。
文摘This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper constructs an internal model to learn the information of the states and input of the grid-connected inverter under steady state.Second,by utilizing the internal model principle,the paper turns the tracking control problem into the robust stabilization control problem based on some appropriate coordinate transformations.Then,The paper designs a dynamics state feedback control law to deal with this robust stabilization problem,and thus the solution of the robust current tracking control problem of three-phase grid-connected inverters can be obtained.This control method can ensure the asymptotic stability of the closedloop system.Finally,the paper illustrates the effectiveness of the proposed control approach through several groups of simulations,and compares it with the feedforward control method to verify the robustness of the proposed control method to uncertain parameters.
基金supported by Natural Science Foundation of Wuhan(2024040701010051)Natural Science Foundation of Hubei(2023AFB111)and National Natural Science Foundation of China(52401108).
文摘To elucidate the accelerated degradation mechanisms of metallic interconnects in operational solid oxide fuel cells,the oxidation behavior of FSS430 ferritic stainless steel under the coupling of simultaneous electrical current and high-temperature exposure is investigated.Isothermal thermogravimetric analysis was employed to quantify oxidation kinetics,complemented by microstructural characterization using X-ray diffraction,scanning electron microscopy with energy-dispersive spectroscopy and transmission electron microscopy.Experimental results demonstrate that the applied current dramatically enhances oxidation rates,increasing specific mass gain from 0.25 mg/cm^(2)(0 A/cm^(2))to 5.20 mg/cm^(2)(0.2 A/cm^(2))and oxide scale thickness from 1.87 to 15.62μm after 200 h.This acceleration originates from current-induced electromigration forces that promote cationic transport through the oxide layer.The quantitative relationships between current density and oxidation parameters are established,enabling predictive modeling of interconnector degradation in solid oxide fuel cell(SOFC)systems.
文摘Exercise produces a decrease in pain sensitivity via an effect called exercise-induced hypoalgesia(EIH).Transcranial direct current stimulation(tDCS),acting on similar analgesic mechanisms as EIH,represents a potential complementary intervention that may amplify the effects of exercise on pain.This study aimed to explore if anodal tDCS could enhance the effect of exercise on pain compared to exercise alone.A total of 35 healthy participants aged 19–37 years completed a familiarisation session followed by two separate sessions where active and sham tDCS was applied in a randomised cross-over design.The familiarisation session involved familiarisation to the pain assessment and exercise tasks,while the subsequent tDCS sessions involved pain sensitivity assessment,exercise and either anodal tDCS or sham tDCS.tDCS doses were applied at 2 mA over the primary motor cortex for 10 min,with the reference electrode placed over the contralateral supraorbital area.The exercise task involved a sustained isometric grip strength contraction at 35%of maximal voluntary contraction(MVC)until volitional exhaustion.Pain sensitivity was evaluated as pressure pain threshold before tDCS,after tDCS,and after exercise.Across both tDCS conditions,pain threshold was higher after exercise when compared to pre-and post-tDCS measurement.This increase in pain threshold did not differ between active and sham tDCS conditions.Our findings suggest that the hypoalgesic effects of active anodal tDCS over the motor cortex prior to exercise are no greater than the effects of sham tDCS prior to exercise.
基金funded by Youth Talent Growth Project of Guizhou Provincial Department of Education(No.Qianjiaoji[2024]21)National Natural Science Foundation of China(No.62461008 and No.52507211)Guizhou Provincial Key Technology R&D Program(No.[2024]General 049).
文摘To address the issues of high costs and low component utilization caused by the independent configuration of hybrid DC circuit breakers(HCBs)and DC power flow controllers(DCPFCs)at each port in existing DC distribution networks,this paper adopts a component sharing mechanism to propose a composite multi-port hybrid DC circuit breaker(CM-HCB)with DC power flow and fault current limitation abilities,as well as reduced component costs.The proposed CM-HCB topology enables the sharing of the main breaker branch(MB)and the energy dissipation branch,while the load commutation switches(LCSs)in the main branch are reused as power flow control components,enabling flexible regulation of power flow in multiple lines.Meanwhile,by reconstructing the current path during the fault process,the proposed CM-HCB can utilize the internal coupled inductor to limit the current rise rate at the initial stage of the fault,significantly reducing the requirement for breaking current.A detailed study on the topological structure,steady-state power flow regulation mechanism,transient fault isolation mechanism,control strategy and characteristic analysis of the proposed CM-HCB is presented.Then,a Matlab/Simulink-based meshed three-terminal DC grid simulation platform with the proposed CM-HCB is built.The results indicate that the proposed CM-HCB can not only achieve flexible power flow control during steady-state operation,but also obtain current rise limitation and fault isolation abilities under short-circuit fault conditions,verifying its correctness and effectiveness.Finally,a comparative economic analysis is conducted between the proposed CM-HCB and the other two existing solutions,confirming that its component sharing mechanism can significantly reduce the number of components,lower system costs,and improve component utilization.
基金supported by the National Natural Science Fund of China(No.41121061)the National Key Basic Research and Development Program(No.2012CB026102)the Fund of the "Hundred People Plan" of CAS(to WenBing Yu)
文摘Pavement snow and icing are worldwide problems, but effective countermeasures are just beginning to be developed in China. The two most common snow and ice removal methods are mechanical clearance and chemical melting, and the advantages and disadvantages of each approach are discussed here, including environmental and structural damage caused by corrosive snow melting agents. New developments in chemical melting agents and mechanical equipment are discussed, and an overview of alternative thermal melting systems is presented, including the use of geothermy and non-geothermal heating systems utilizing solar energy, electricity, conductive pavement materials, and infrared/microwave applications. Strategic recommendations are made for continued enhancement of public safety in snow and ice conditions.
基金the University of California at Berkeley.Ms.Y.Song gratefully acknowledges the financial support from the Chinese Scholar Council(CSC Grant No.201706680094).
文摘De-icing technology has become an increasingly important subject in numerous applications in recent years.However,the direct numerical modeling and simulation the physical process of thermomechanical deicing is limited.This work is focusing on developing a numerical model and tool to direct simulate the de-icing process in the framework of the coupled thermo-mechanical peridynamics theory.Here,we adopted the fully coupled thermo-mechanical bond-based peridynamics(TM-BB-PD)method for modeling and simulation of de-icing.Within the framework of TM-BB-PD,the ice constitutive model is established by considering the influence of the temperature difference between two material points,and a modified failure criteria is proposed,which takes into account temperature effect to predict the damage of quasi-brittle ice material.Moreover,thermal boundary condition is used to simulate the thermal load in the de-icing process.By comparing with the experimental results and the previous reported finite element modeling,our numerical model shows good agreement with the previous predictions.Based on the numerical results,we find that the developed method can not only predict crack initiation and propagation in the ice,but also predict the temperature distribution and heat conduction during the de-icing process.Furthermore,the influence of the temperature for the ice crack growth pattern is discussed accordingly.In conclusion,the coupled thermal-mechanical peridynamics formulation with modified failure criterion is capable of providing a modeling tool for engineering applications of de-icing technology.
文摘This paper proposes a numerical method to analyze the ice protection capability and predict the power requirements of a piezoelectric resonant de-icing system.The method is based on a coupled electro-mechanical finite element analysis which enables the fast computation of the modes of resonance of interest to de-ice curved surfaces and the estimation of the input voltage and current required for a given configuration(defined by its mode,actuator location,ice deposit,etc.).Eventually,the electric power to be supplied can be also assessed.The method is applied to a NACA 0024 leading edge equipped with piezoelectric actuators.First,two extension modes are analyzed and compared with respect to their efficiency and power requirements.Then,tests are carried out in an icing tunnel to verify the effectiveness of the piezoelectric ice protection system and the predictions of the maximal required power.The system allows de-icing the leading edge in less than 2 s for a glaze ice deposit.
基金financially supported by the Science Innovation Project of Beijing Forestry University (No. 101305)the 985 Innovation Platform, China
文摘In order to prevent severe pollution by de-icing salt on greenery along urban roads, a half lethal dose (LD_50)for a plant population was confirmed through stress simulation of chloride de-icing salt on Euonymus japonicus, with an ianalysis of physiological changes, statistics on mortality rate on plant populations and mathematic modeling during a 30- day subacute toxicity test. The results indicate that a significant positive correlation in the early stages and a significant negative correlation in the later stages were observed between the amount of chlorophyll a and b in plants and a cumulative dose of de-icing salt. The amounts of free proline in plants and the dose of de-icing salt were positively correlated Over the entire period. No significant correlation in the initial stage, but a significant negative correlation in later stages was observed between the soluble protein and the dose of de-icing salt. LDs0 of this chloride agent on E. japonicus is 5 kg.(L·m2)-1 over 30 days.
基金financially supported by National Natural Science Foundation of China(No.12002384)National Key Laboratory Foundation of China(No.614220220200107)+1 种基金National Science and Technology Major Project of China(No.J2019-II-0014-0035)Academician Workstation F0undation of the Green Aerotechnics Research Institute of Chongqing Jiaotong University(No.GATRI2020C06003)。
文摘Since flight accidents due to aircraft icing occur from time to time,this paper proposes an array of impact rod-type plasma synthetic jet de-icing methods for aircraft icing problems.The impact rod-type plasma synthetic jet actuator(PSJA)is based on the traditional PSJA with an additional impact rod structure for better de-icing in the flight environment.In this work,we first optimize the ice-breaking performance of a single-impact rod-type PSJA,and then conduct an array of impact rod-type plasma synthetic jet ice-breaking experiments to investigate the relationship between crack expansion and discharge energy,ice thickness and group spacing.The results show that the impact force and impulse of a single-impact rod-type PSJA are proportional to the discharge energy,and there exists a threshold energy Qmin for a single actuator to break the ice,which is proportional to the ice thickness.Only when the discharge energy reaches above Qmin can the ice layer produce cracks,and at the same time,the maximum radial crack length produced during the ice-breaking process is proportional to the discharge energy.When the ice is broken by an array of impact rod PSJAs,the discharge energy and group spacing together determine whether the crack can be extended to the middle region of the actuator.When the group spacing is certain,increasing the energy can increase the intersection of cracks in the middle region,and the ice-fragmentation degree is increased and the ice-breaking effect is better.At the same time,the energy estimation method of ice breaking by an array of impact rod-type PSJAs is proposed according to the law when a single actuator is breaking ice.
基金supported in part by Natural Science Foundation of Jiangsu Province under Grant BK20230255Natural Science Foundation of Shandong Province under Grant ZR2023QE281.
文摘The multi-terminal direct current(DC)grid has extinctive superiorities over the traditional alternating current system in integrating large-scale renewable energy.Both the DC circuit breaker(DCCB)and the current flow controller(CFC)are demanded to ensure the multiterminal DC grid to operates reliably and flexibly.However,since the CFC and the DCCB are all based on fully controlled semiconductor switches(e.g.,insulated gate bipolar transistor,integrated gate commutated thyristor,etc.),their separation configuration in the multiterminal DC grid will lead to unaffordable implementation costs and conduction power losses.To solve these problems,integrated equipment with both current flow control and fault isolation abilities is proposed,which shares the expensive and duplicated components of CFCs and DCCBs among adjacent lines.In addition,the complicated coordination control of CFCs and DCCBs can be avoided by adopting the integrated equipment in themultiterminal DC grid.In order to examine the current flow control and fault isolation abilities of the integrated equipment,the simulation model of a specific meshed four-terminal DC grid is constructed in the PSCAD/EMTDC software.Finally,the comparison between the integrated equipment and the separate solution is presented a specific result or conclusion needs to be added to the abstract.
文摘This paper presents a self-structured organizing single-input control system based on differentiable cerebellar model articulation controller (CMAC) for an n-link robot manipulator to achieve the high-precision position tracking. In the proposed scheme, the single-input CMAC controller is solely used to control the plant, so the input space dimension of CMAC can be simplified and no conventional controller is needed. The structure of single-input CMAC will also be self-organized;that is, the layers of single-input CMAC will grow or prune systematically and their receptive functions can be automatically adjusted. The online tuning laws of single-input CMAC parameters are derived in gradient-descent learning method and the discrete-type Lyapunov function is applied to determine the learning rates of the proposed control system so that the stability of the system can be guaranteed. The simulation results of three-link De-icing robot manipulator are provided to verify the effectiveness of the proposed control methodology.
基金Core Research Institute Basic Science Research Program through the National Research Foundation of Korea(NRF)funded by the Ministry of Education(No.2018R1A6A1A03025242)in part by the research grant of Kwangwoon University in 2024。
文摘Advanced OER/HER electrocatalytic alternatives are crucial for the wide adaptation of green hydrogen energy.Herein,Ru/NiMnB spherical cluster pillar(SCP),denoted as Ru/NiMnB,is synthesized using a combination of electro-deposition and hydrothermal reaction.Systematic investigation of Ru doping in the NiMnB matrix revealed significant improvements in electrocatalytic performance.The Ru/NiMnB SCPs demonstrate superior OER/HER activity with low overpotentials of 150 and 103 mV at 50mA/cm^(2)in 1 M KOH,making them highly competitive with state-of-the-art electrocatalysts.Remarkably,the Ru/NiMnB SCPs exhibit a low 2-E cell voltage of 2.80 V at ultra-high current density of 2,000 m A/cm^(2)in 1 M KOH,outperforming the standard benchmark electrodes of RuO_(2)||Pt/C,thereby positioning Ru/NiMnB as one of the best bifunctional electrocatalysts.These SCPs exhibit exceptional high-current characteristics,stability and corrosion resistance,as evidenced by continuous operation at 1,000 mA/cm^(2)high-current density for over 150 h in 6 M KOH at elevated temperatures under harsh industrial conditions.Only a small amount of Ru incorporation significantly enhances the electrocatalytic performances of NiMnB,attributed to increased active sites and improved intrinsic properties such as conductivity,adsorption/desorption capability and reaction rates.Consequently,Ru/NiMnB SCPs present a promising bi-functional electrode concept for efficient green H_(2)production.
基金funding from the European Union’s Horizon 2020 research and innovation program through the European IMPULSE project under Grant Agreement No.871161from LASERLAB-EUROPE V under Grant Agreement No.871124+6 种基金from the Grant Agency of the Czech Republic(Grant No.GM23-05027M)Grant No.PDC2021120933-I00 funded by MCIN/AEI/10.13039/501100011033by the European Union Next Generation EU/PRTRsupported by funding from the Ministerio de Ciencia,Innovación y Universidades in Spain through ICTS Equipment Grant No.EQC2018-005230-Pfrom Grant No.PID2021-125389O A-I00 funded by MCIN/AEI/10.13039/501100011033/FEDER,UEby“ERDF A Way of Making Europe”by the European Unionfrom grants of the Junta de Castilla y León with Grant Nos.CLP263P20 and CLP087U16。
文摘This work demonstrates experimentally the close relation between return currents from relativistic laser-driven target polarization and the quality of the relativistic laser–plasma interaction for laser-driven secondary sources,taking as an example ion acceleration by target normal sheath acceleration.The Pearson linear correlation of maximum return current amplitude and proton spectrum cutoff energy is found to be in the range from~0.70 to 0.94.kA-scale return currents rise in all interaction schemes where targets of any kind are charged by escaping laser-accelerated relativistic electrons.Their precise measurement is demonstrated using an inductive scheme that allows operation at high repetition rates.Thus,return currents can be used as a metrological online tool for the optimization of many laser-driven secondary sources and for diagnosing their stability.In particular,in two parametric studies of laser-driven ion acceleration,we carry out a noninvasive online measurement of return currents in a tape target system irradiated by the 1 PW VEGA-3 laser at Centro de Láseres Pulsados:first the size of the irradiated area is varied at best compression of the laser pulse;second,the pulse duration is varied by means of induced group delay dispersion at best focus.This work paves the way to the development of feedback systems that operate at the high repetition rates of PW-class lasers.
基金Supported by National Natural Science Foundation of China,No.82205298Natural Science Foundation of Hunan Province,No.2023JJ30462+1 种基金Hunan Provincial Department of Science and Technology,No.2023SK2045,No.22JBZ007,No.Z2023XJYQ07,No.B2024007,and No.Z2023JB012024 Graduate Innovation Topics,No.2024CX031.
文摘BACKGROUND Diabetic gastroparesis(DGP)disrupts gastric motility.Electroacupuncture(EA)at Zusanli(ST36)may alleviate DGP symptoms via neural pathways.AIM To investigate how EA current intensities at ST36 regulate neural pathways and improve gastric motility in DGP models.METHODS A DGP model was established using intraperitoneal injection of streptozotocin.Gastrointestinal motility was measured in rats after 2 weeks of continuous EA at ST36.Current intensity was selected as 0.5 mA,1 mA,and 3 mA.Gastric electrodynamics were detected by recording and analyzing the number of gastric discharges.The gastric emptying rate and propulsion rate of the small intestine were measured to assess dynamic gastrointestinal function.Hematoxylin-eosin staining was conducted to measure histopathological changes in the gastric sinus.Reverse transcription-polymerase chain reaction was conducted to determine mRNA levels of Rho guanine nucleotide-binding protein A and Rho-associated coiled-coil forming protein kinase.Western blotting was conducted to determine the expression levels of choline acetyltransferase,tyrosine hydroxylase,Rho guanine nucleotide-binding protein A,and Rho-associated coiled-coil forming protein kinase.Immunofluorescence staining in the stomach was conducted to detect the distribution of C-kit,an interstitial cell of Cajal marker.An enzymelinked immunosorbent assay was conducted to detect serum levels of acetylcholine and norepinephrine.RESULTS Treatment with EA improved gastric emptying and gastric smooth muscle disorders in rats with DGP,mitigated pathological damage,and restored the function of interstitial cells of Cajal.In addition,different current intensities of EA affected gastrointestinal function of rats with DGP.The 0.5 mA,1 mA,and 3 mA EA groups all improved gastrointestinal function.0.5 mA EA increased acetylcholine levels by increasing protein expression of choline acetyltransferase(P<0.05),thereby upregulating vagus nerve activity and enhancing parasympathetic nerve regulation.3 mA EA increased norepinephrine levels(P<0.05)by increasing protein expression of tyrosine hydroxylase,thereby activating the sympathetic nervous pathway.1 mA coordinated the function of the vagus and sympathetic nerves to improve gastrointestinal motility.CONCLUSION EA with ST36 improved gastric motility in rats with DGP.0.5 mA EA activated the vagus nerve,while 3 mA EA regulated gastrointestinal motility by activating the sympathetic nerves.
基金supported by the National Natural Science Foundation of China (42250101)the Macao Foundation. The computation made use of the high-performance computing resources at the center of the MSS data processing and analysis。
文摘Accurate modeling of Earth's ionospheric F-region currents is essential for refining geomagnetic field models and understanding magnetosphere-ionosphere coupling.In this study,we develop averaged models to characterize F-region currents using magnetic data from the MSS-1(Macao Science Satellite-1) and Swarm satellite missions.Our approach employs a toroidal field representation,utilizing spherical harmonics to capture spatial variations and Fourier series to represent temporal dynamics.Two models,Model-A and Model-B,derived from distinct datasets,are constructed to represent current patterns at altitudes of 450 km and 512 km,respectively.Our models successfully capture the primary spatial structures and seasonal variations of polar field-aligned currents.Additionally,they accurately reproduce the localized inter-hemispheric field-aligned currents observed in mid and low latitudes during solstices,particularly between 14:00 and 16:00 magnetic local times.These findings enhance our understanding of ionospheric F-region currents and contribute to more precise geomagnetic field modeling.
基金supported by the Fundamental Research Funds for the Central Universities(No.FRF-BD-23-01).
文摘Non-metallic inclusions in steel are a significant challenge,affecting material properties and leading to issues such as stress concentration,cracking,and accelerated corrosion.Current methods for removing inclusions,including bubble,electromagnetic stirring,filtration separation,fluid flow,and sedimentation,often struggle with the removal of fine inclusions.Apart from these known methods,pulsed electric current(PEC),as an emerging technology,has demonstrated immense potential and environmental advantages.PEC offers adjustable current parameters and simple equipment,making it an attractive alternative to traditional methods.Its green energy-saving features and excellent results in regulating inclusion morphology and migration,as well as inhibiting submerged entry nozzle(SEN)clogging,make it a promising technology.In comparison to continuous current technology,PEC has shown significant advantages in regulating inclusions,not only improving purification efficiency but also demonstrating outstanding performance in flow stability and energy consumption.The ability of PEC to efficiently reduce inclusion numbers enhances the purity and quality of molten steel,improving its mechanical properties.Currently,the theoretical basis for controlling the movement of inclusions by current is mainly composed of three major theories:the double electric layer theory,electromagnetic force reverse separation theory,and electric free energy drive theory.These theories together form an important framework for researchers to understand and optimize the behavior of impurity movement controlled by electric current.Looking ahead,PEC is expected to pave the way for new solutions in directional regulation of inclusion migration,efficient inclusion removal,SEN clogging prevention,and the purification of molten steel.
基金supported by the National Natural Science Foundation of China under Grant 52407069the Science and Technology Project of Zhejiang Province under Grant 2024C01254the China Postdoctoral Science Foundation under Grant 2024T170766 and 2024M762824。
文摘The phase-locked loop(PLL)plays an essential role for synchronizing renewable power generation to the grid.However,as per the grid-code compliance for reactive current support,the PLL output frequency fluctuates significantly and exceeds the limitation,which seriously threaten the safe supply of electricity.In this paper,the underlying theoretical mechanism and dominant force behind the maximum PLL frequency deviation are revealed.Accordingly,two feasible approaches are proposed to enhance the PLL frequency stability with validations in experimental results.
基金supported by the the National Key R&D Program of China(2022YFB3803500)the Natural Science Foundation of Hubei Province(2021CFA066).
文摘Micron-sized silicon(μSi)is a promising anode material for next-generation lithium-ion batteries due to its high specific capacity,low cost,and abundant reserves.However,the volume expansion that occurs during cycling leads to the accumulation of undesirable stresses,resulting in pulverization of silicon microparticles and shortened lifespan of the batteries.Herein,a composite film of Cu-PET-Cu is proposed as the current collector(CC)forμSi anodes to replace the conventional Cu CC.Cu-PET-Cu CC is prepared by depositing Cu on both sides of a polyethylene terephthalate(PET)film.The PET layer promises good ductility of the film,permitting the Cu-PET-Cu CC to accommodate the volumetric changes of silicon microparticles and facilitates the stress release through ductile deformation.As a result,theμSi electrode with Cu-PET-Cu CC retains a high specific capacity of 2181 mA h g^(-1),whereas theμSi electrode with Cu CC(μSi/Cu)exhibits a specific capacity of 1285 mA h g^(-1)after 80 cycles.The stress relieving effect of CuPET-Cu was demonstrated by in-situ fiber optic stress monitoring and multi-physics simulations.This work proposes an effective stress relief strategy at the electrode level for the practical implementation ofμSi anodes.