In this paper, the measurement method of calorimetric power for an electron cyclotron resonance heating(ECRH) system for EAST is presented. This method requires measurements of the water flow through the cooling cir...In this paper, the measurement method of calorimetric power for an electron cyclotron resonance heating(ECRH) system for EAST is presented. This method requires measurements of the water flow through the cooling circuits and the input and output water temperatures in each cooling circuit. Usually, the inlet water temperature stability is controlled to obtain more accurate results.The influence of the inlet water temperature change on the measurement results is analyzed for the first time in this paper. Also, a novel temperature calibration method is proposed. This kind of calibration method is accurate and effective, and can be easily implemented.展开更多
Radiology and Medical Imaging is a unique clinical discipline characterized by continuing and rapid changing of its landscape[1,2].Mainly driving by engineering progress,new techniques and data acquisition method are ...Radiology and Medical Imaging is a unique clinical discipline characterized by continuing and rapid changing of its landscape[1,2].Mainly driving by engineering progress,new techniques and data acquisition method are introduced almost every year.It is also heavily multidisciplinary,while crossdisciplinary research can be both rewarding and highly risky[3].Due to the rapidly changing nature of medical imaging,new research results can be soon become obsolete.For the young academic radiologists in China who aspire to have their research efforts making a long-lasting impact on patient care,hereby I express some of my personal experiences and viewpoints.展开更多
基金supported by the National Magnetic Confinement Fusion Science Program of China (Grant Nos.2011GB102000, 2015GB103000)
文摘In this paper, the measurement method of calorimetric power for an electron cyclotron resonance heating(ECRH) system for EAST is presented. This method requires measurements of the water flow through the cooling circuits and the input and output water temperatures in each cooling circuit. Usually, the inlet water temperature stability is controlled to obtain more accurate results.The influence of the inlet water temperature change on the measurement results is analyzed for the first time in this paper. Also, a novel temperature calibration method is proposed. This kind of calibration method is accurate and effective, and can be easily implemented.
文摘Radiology and Medical Imaging is a unique clinical discipline characterized by continuing and rapid changing of its landscape[1,2].Mainly driving by engineering progress,new techniques and data acquisition method are introduced almost every year.It is also heavily multidisciplinary,while crossdisciplinary research can be both rewarding and highly risky[3].Due to the rapidly changing nature of medical imaging,new research results can be soon become obsolete.For the young academic radiologists in China who aspire to have their research efforts making a long-lasting impact on patient care,hereby I express some of my personal experiences and viewpoints.