The Beijing Spectrometer Ⅲ(BESⅢ)is a general-purpose detector used for the study of τ-charm physics at the Beijing Electron-Positron Collider Ⅱ(BEPC Ⅱ).This paper presents our studies of the dE/dx measurement...The Beijing Spectrometer Ⅲ(BESⅢ)is a general-purpose detector used for the study of τ-charm physics at the Beijing Electron-Positron Collider Ⅱ(BEPC Ⅱ).This paper presents our studies of the dE/dx measurement in the drift chamber of BESⅢ,which is important for the identification of charged particles.Corrections applied to the dE/dx measurement in data reconstruction are discussed.After our current dE/dx calibration,a resolution of about 6% has been obtained for minimum ionization particles,and a 3σ K/πseparation is obtained for momenta up to 760 MeV/c.These results meet the design goals of the BESⅢ drift chamber.展开更多
The reconstruction of muon energies is crucial for the data analysis of neutrino experiments using large water Cherenkov detectors,but the resolution for muon energy reconstruction using traditional methods is poor.He...The reconstruction of muon energies is crucial for the data analysis of neutrino experiments using large water Cherenkov detectors,but the resolution for muon energy reconstruction using traditional methods is poor.Here,we propose a revised approach to remove noisy optical modules along the track produced by the propagation of muons through water.The number of photons on the optical modules is first corrected by the attenuation properties of light in water.Then the difference in time between the observed optical modules and the expected ones is determined based on the geometry of the triggered optical modules.Finally,the standard of correction is measured by the ratio of photon number before and after correction.Optical modules selection conditions were optimized according to these parameters,with most noisy optical modules successfully removed,improving the resolution of muon energy reconstruction.展开更多
基金Supported by National Natural Science Foundation of China (10821063, 10875141, 10705034, 10605030)Ministry of Science and Technology of China (2009CB825200)+1 种基金Chinese Academy of Sciences (CAS) Large-Scale Scientific Facility Program (KJCX2-YW-N29, KJCX2-YW-N45)United States Department of Energy (DE-FG02-91ER40682)
文摘The Beijing Spectrometer Ⅲ(BESⅢ)is a general-purpose detector used for the study of τ-charm physics at the Beijing Electron-Positron Collider Ⅱ(BEPC Ⅱ).This paper presents our studies of the dE/dx measurement in the drift chamber of BESⅢ,which is important for the identification of charged particles.Corrections applied to the dE/dx measurement in data reconstruction are discussed.After our current dE/dx calibration,a resolution of about 6% has been obtained for minimum ionization particles,and a 3σ K/πseparation is obtained for momenta up to 760 MeV/c.These results meet the design goals of the BESⅢ drift chamber.
基金supported by Institute of High Energy Physics (E25156U110)the Sichuan Department of Science and Technology (2023YFSY0014).
文摘The reconstruction of muon energies is crucial for the data analysis of neutrino experiments using large water Cherenkov detectors,but the resolution for muon energy reconstruction using traditional methods is poor.Here,we propose a revised approach to remove noisy optical modules along the track produced by the propagation of muons through water.The number of photons on the optical modules is first corrected by the attenuation properties of light in water.Then the difference in time between the observed optical modules and the expected ones is determined based on the geometry of the triggered optical modules.Finally,the standard of correction is measured by the ratio of photon number before and after correction.Optical modules selection conditions were optimized according to these parameters,with most noisy optical modules successfully removed,improving the resolution of muon energy reconstruction.