When the converter bus voltage of a voltage source converter-based high voltage direct current(VSC-HVDC)system drops below a certain predetermined threshold,the system enters low-voltage ride-through(LVRT)mode to avoi...When the converter bus voltage of a voltage source converter-based high voltage direct current(VSC-HVDC)system drops below a certain predetermined threshold,the system enters low-voltage ride-through(LVRT)mode to avoid overcurrent and potential equipment failure,during which it operates as a controlled current source.The influence mechanism of LVRT control strategies on short-circuit current and overall system stability remains not yet fully and systematically investigated.First,this paper provides an overview of several LVRT strategies for VSC-HVDC systems and examines their effects on short-circuit current contribution.Next,it analyzes in detail the mechanisms through which active and reactive currents injected during LVRT impact system frequency stability,voltage stability,and synchronization stability.To address these interrelated issues,an optimized and comprehensive LVRT strategy incorporating short-circuit current constraints is proposed.The approach determines the active current ratio based on system frequency stability requirements and dynamically adjusts the active current recovery rate via phase control of the VSC-HVDC bus.The remaining capacity is allocated to reactive current support,thereby enhancing voltage and synchronization stability while maintaining sufficient short-circuit current margin and system frequency stability.Finally,simulations conducted on the PSS/E platform,using actual grid data from a selected cross-section system,validate convincingly the effectiveness of the proposed parameter optimization strategy for VSC-HVDC low-voltage ride-through.展开更多
With the growing integration of renewable energy sources(RESs)and smart interconnected devices,conventional distribution networks have turned to active distribution networks(ADNs)with complex system model and power fl...With the growing integration of renewable energy sources(RESs)and smart interconnected devices,conventional distribution networks have turned to active distribution networks(ADNs)with complex system model and power flow dynamics.The rapid fluctuation of RES power may easily result in frequent voltage violation issues.Taking the flexible RES reactive power as control variables,this paper proposes a two-layer control scheme with Koopman wide neural network(WNN)based model predictive control(MPC)method for optimal voltage regulation and network loss reduction.Based on Koopman operator theory,a data-driven WNN method is presented to fit a high-dimensional linear model of power flow.With the model,voltage and network loss sensitivities are computed analytically,and utilized for ADN partition and control model formulation.In the lower level,a dual-mode adaptive switching MPC strategy is put forward for optimal voltage control and network loss optimization in each individual partition to decide the RES reactive power.The upper level is to calculate the adjustment coefficients of the RES reactive power given in the low level by taking the coupling effects of different partitions into account,and then the final reactive power dispatches of RESs are obtained to realize optimal control of voltage and network loss.Simulation results on two ADNs demonstrate that the proposed strategy can reliably maintain the voltage at each node within the secure range,reduce network power losses,and enhance the overall system security and economic efficiency.展开更多
To address the issue of transient low-voltage instability in AC-DC hybrid power systems following large disturbances,conventional voltage assessment and control strategies typically adopt a sequential“assess-then-act...To address the issue of transient low-voltage instability in AC-DC hybrid power systems following large disturbances,conventional voltage assessment and control strategies typically adopt a sequential“assess-then-act”paradigm,which struggles to simultaneously meet the requirements for both high accuracy and rapid response.This paper proposes a transient voltage assessment and control method based on a hybrid neural network incorporated with an improved snow ablation optimization(ISAO)algorithm.The core innovation of the proposed method lies in constructing an intelligent“physics-informed and neural network-integrated”framework,which achieves the integration of stability assessment and control strategy generation.Firstly,to construct a highly correlated input set,response characteristics reflecting the system’s voltage stable/unstable states are screened.Simultaneously,the transient voltage severity index(TVSI)is introduced as a comprehensive metric to quantify the system’s post-disturbance transient voltage performance.Furthermore,the load bus voltage sensitivity index(LVSI)is defined as the ratio of the voltage change magnitude at a load node(or bus)to the change in the system-level TVSI,thereby pinpointing the response characteristics of critical load nodes.Secondly,both the transient voltage stability assessment result and its corresponding under-voltage load shedding(UVLS)control amount are jointly utilized as the outputs of the response-driven model.Subsequently,the snow ablation optimization(SAO)algorithm is enhanced using a good point set strategy and a Gaussian mutation strategy.This improved algorithm is then employed to optimize the key hyperparameters of the hybrid neural network.Finally,the superiority of the proposed method is validated on a modified CEPRI-36 system and an actual power grid case.Comparisons with various artificial intelligence methods demonstrate its significant advantages in model speed and accuracy.Additionally,when compared to traditional emergency control schemes and UVLS strategies,the proposed method exhibits exceptional rapidness and real-time capability in control decision-making.展开更多
With the prevalence of renewable distributed energy resources(DERs)such as photovoltaics(PVs),modern active distribution networks(ADNs)suffer from voltage deviation and power quality issues.However,traditional voltage...With the prevalence of renewable distributed energy resources(DERs)such as photovoltaics(PVs),modern active distribution networks(ADNs)suffer from voltage deviation and power quality issues.However,traditional voltage control methods often face a trade-off between efficiency and effectiveness,and rarely ensure robust voltage safety under typical state perturbations in practical distribution grids.In this paper,a robust model-free voltage regulation approach is proposed which simultaneously takes security and robustness into account.In this context,the voltage control problem is formulated as a constrained Markov decision process(CMDP).A safety-augmented multiagent deep deterministic policy gradient(MADDPG)algorithm is the trained to enable real-time collaborative optimization of ADNs,aiming to maintain nodal voltages within safe operational limits while minimizing total line losses.Moreover,a robust regulation loss is introduced to ensure reliable performance under various state perturbations in practical voltage controls.The proposed regulation algorithm effectively balance efficiency,safety,and robustness,and also demonstrates potential for generalizing these characteristics to other applications.Numerical studies vali-date the robustness of the proposed method under varying state perturbations on the IEEE test cases and the optimal integrated control performance when compared to other benchmarks.展开更多
The transient behavior of DC-link voltage(DCV)significantly affects the low-voltage ride-through for phase-locked loop(PLL)-based grid-connected doubly-fed induction generator(DFIG)systems.This study investigates the ...The transient behavior of DC-link voltage(DCV)significantly affects the low-voltage ride-through for phase-locked loop(PLL)-based grid-connected doubly-fed induction generator(DFIG)systems.This study investigates the DCV transient behavior of a PLL-based DFIG system under asymmetrical grid faults.First,by considering the coupling characteristics of positive and negative sequence(PNS)components,a nonlinear largesignal model of DCV is developed.Furthermore,the transient characteristics of DCV under varying parameters are analyzed using phase trajectory diagrams.In addition,the transient stability(TS)mechanism of DCV during asymmetrical faults is examined through an en-ergy function approach.The analysis indicates that the transient instability of DCV is primarily associated with the control characteristics of PNS PLLs,while the TS level of DCV is mainly determined by the power coordination control between the rotor side converter and grid side converter.Moreover,a coordinated control strategy is proposed to enhance the TS of DCV under asymmet-rical grid faults.Finally,both simulation and experimental results are presented to validate the theoretical analysis and the effectiveness of the proposed strategy.展开更多
Voltage source converters(VSCs),equipped with Pf and Q-U droop characteristics,can support a power system from both frequency and voltage.Unfortunately,overcurrent and power angle instability are still challenging asp...Voltage source converters(VSCs),equipped with Pf and Q-U droop characteristics,can support a power system from both frequency and voltage.Unfortunately,overcurrent and power angle instability are still challenging aspects of VSCs under fault conditions.Therefore,fault current limitation and power angle stability are essential conditions for the safe operation of a VSC.Thus,the transient characteristics of a VSC are analyzed to guide transient control.Then,a transient control method for a VSC,considering both fault current limitation and power angle stability,is proposed.With the proposed method,power angle stability is realized by optimizing the P-f controller.On the basis of power angle control,the Q-U controller and inner current controller are improved to effectively suppress the fault current.Finally,relevant tests are performed to verify the proposed method.展开更多
This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper cons...This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper constructs an internal model to learn the information of the states and input of the grid-connected inverter under steady state.Second,by utilizing the internal model principle,the paper turns the tracking control problem into the robust stabilization control problem based on some appropriate coordinate transformations.Then,The paper designs a dynamics state feedback control law to deal with this robust stabilization problem,and thus the solution of the robust current tracking control problem of three-phase grid-connected inverters can be obtained.This control method can ensure the asymptotic stability of the closedloop system.Finally,the paper illustrates the effectiveness of the proposed control approach through several groups of simulations,and compares it with the feedforward control method to verify the robustness of the proposed control method to uncertain parameters.展开更多
During sending-end faults in the hybrid cascaded HVDC(HC-HVDC)system,the transient voltage drop characteristics under the interaction of the AC/DC hybrid system remain unclear,and the reactive power support provided b...During sending-end faults in the hybrid cascaded HVDC(HC-HVDC)system,the transient voltage drop characteristics under the interaction of the AC/DC hybrid system remain unclear,and the reactive power support provided by the HC-HVDC to the sending-end AC system requires further investigation.To address this problem,the reactive power interaction coupling mechanism between the sending-end AC system and the HC-HVDC is revealed,and the transient voltage mathematical model considering fault severity and duration is established.Under the dynamic change of the AC system voltage,the difference between the reactive power provided only by the reactive power compensation devices and by the combined modular multilevel converters(MMC)and reactive power compensation devices is analyzed.It is concluded that using MMC to provide a proportion of reactive power enhances the reactive power support to the AC system during faults.Then,the transient voltage model considering the reactive power support of MMC is established,and the critical reactive power consumption of line commutated converter(LCC)is quantified.It is concluded that the reactive power consumption of LCC exceeding its critical value deteriorates the transient voltage.A coordinated support strategy for the sending-end AC system based on reactive power support of MMC and reactive power regulation of LCC is proposed.It can effectively address the challenge of weakened reactive power support to the AC system due to voltage drop,thereby preventing the unbalanced reactive power from deteriorating the transient voltage,and realizing active support of the tran-sient voltage.Finally,a simulation model is established on the PSCAD/EMTDC platform,and the simulation results validate the effectiveness of the proposed strategy in supporting the transient voltage,under different fault types,durations,severities,and locations.展开更多
A multi-phase stacked interleaved buck converter(SIBC)is suitable for large-power water electrolysis applications due to its merits of high current output capability and zero output current ripple.However,the auxiliar...A multi-phase stacked interleaved buck converter(SIBC)is suitable for large-power water electrolysis applications due to its merits of high current output capability and zero output current ripple.However,the auxiliary converter used to compensate for the current ripple still has to withstand high voltage stress.This paper proposes a new multi-phase SIBC applied in the multicarrier energy system integrating electricity,heat,and hydrogen.A resistor-capacitor voltage divider is used to provide the input voltage of the auxiliary converter and as a heater for the thermal loads.Thus,the voltage stress of the auxiliary converter can be reduced at a low cost,and the size of the filter inductor can be reduced.With accurate voltage and current analysis and appropriate parameter design,the voltage stresses of both the switches and capacitors in the auxiliary converter can be further limited within an expected range.The experimental results verify the correctness of the topology,modulation,analysis,and design methods.A comparison with the conventional method is made in terms of cost,volume,and efficiency to show the advantages of the proposed method.展开更多
The transient synchronization stability of grid-forming converters(GFMCs)is significantly challenged under grid voltage sags.Continuous efforts have been devoted to analyzing the GFMC transient stability,with limited ...The transient synchronization stability of grid-forming converters(GFMCs)is significantly challenged under grid voltage sags.Continuous efforts have been devoted to analyzing the GFMC transient stability,with limited attention paid to the impacts of control loop dynamics.However,the complex control dynamics,especially the interactions between the active/reactive power control loops and the current saturation process(CSP),are crucial for accurately describing the transient behavior and evaluating the stability.Thus,in this study,a new large-signal GFMC model is established,considering the reactive power control(RPC)with different kinds of controllers and the CSP simultaneously.It is revealed that GFMC does not switch to the current-limited mode immediately,and the dynamics of RPC further affect the transient behavior before the current limiting significantly.Hence,the complex control dynamics can alter the mode switching point of current saturation,thereby increasing the risk of loss of synchronization(LOS).Based on the above findings,comprehensive comparisons of typical RPC controllers are presented to facilitate practical engineering applications.A unified stability enhancement method is proposed for solving the problem of LOS.Finally,experiments validate the correctness of the analysis and the effectiveness of the proposed control strategy.展开更多
In position-sensorless brushless direct current(DC)motors(BLDCMs)fed by a four-switch three-phase(FSTP)inverter,only two phases are fully controlled,while the remaining phase is tied to the midpoint of the split DC-li...In position-sensorless brushless direct current(DC)motors(BLDCMs)fed by a four-switch three-phase(FSTP)inverter,only two phases are fully controlled,while the remaining phase is tied to the midpoint of the split DC-link capacitors.The voltage pulses required by inductance-based initial position detection can cause unequal discharge of the series capacitors,shifting the neutral-point voltage away from half of DC-link voltage(U_(dc)/2).This neutral-point drift breaks the spatial symmetry of the inverter voltage vectors,so the 360°electrical period can no longer be evenly partitioned into six sectors during initial rotor position detection.To address this issue,this paper proposes a detection-pulse injection sequence that explicitly accounts for the asymmetric voltage vectors of the FSTP inverter.With the proposed sequence,the initial rotor position can be identified within a 30°electrical sector.The method requires no additional voltage or current sensors,and experimental results confirm its feasibility.展开更多
Fluctuating voltage levels in power grids necessitate automatic voltage regulators(AVRs)to ensure stability.This study examined the modeling and control of AVR in hydroelectric power plants using model predictive cont...Fluctuating voltage levels in power grids necessitate automatic voltage regulators(AVRs)to ensure stability.This study examined the modeling and control of AVR in hydroelectric power plants using model predictive control(MPC),which utilizes an extensive mathe-matical model of the voltage regulation system to optimize the control actions over a defined prediction horizon.This predictive feature enables MPC to minimize voltage deviations while accounting for operational constraints,thereby improving stability and performance under dynamic conditions.Thefindings were compared with those derived from an optimal proportional integral derivative(PID)con-troller designed using the artificial bee colony(ABC)algorithm.Although the ABC-PID method adjusts the PID parameters based on historical data,it may be difficult to adapt to real-time changes in system dynamics under constraints.Comprehensive simulations assessed both frameworks,emphasizing performance metrics such as disturbance rejection,response to load changes,and resilience to uncertainties.The results show that both MPC and ABC-PID methods effectively achieved accurate voltage regulation;however,MPC excelled in controlling overshoot and settling time—recording 0.0%and 0.25 s,respectively.This demonstrates greater robustness compared to conventional control methods that optimize PID parameters based on performance criteria derived from actual system behavior,which exhibited settling times and overshoots exceeding 0.41 s and 5.0%,respectively.The controllers were implemented using MATLAB/Simulink software,indicating a significant advancement for power plant engineers pursuing state-of-the-art automatic voltage regulations.展开更多
The high proportion of uncertain distributed power sources and the access to large-scale random electric vehicle(EV)charging resources further aggravate the voltage fluctuation of the distribution network,and the exis...The high proportion of uncertain distributed power sources and the access to large-scale random electric vehicle(EV)charging resources further aggravate the voltage fluctuation of the distribution network,and the existing research has not deeply explored the EV active-reactive synergistic regulating characteristics,and failed to realize themulti-timescale synergistic control with other regulatingmeans,For this reason,this paper proposes amultilevel linkage coordinated optimization strategy to reduce the voltage deviation of the distribution network.Firstly,a capacitor bank reactive power compensation voltage control model and a distributed photovoltaic(PV)activereactive power regulationmodel are established.Additionally,an external characteristicmodel of EVactive-reactive power regulation is developed considering the four-quadrant operational characteristics of the EVcharger.Amultiobjective optimization model of the distribution network is then constructed considering the time-series coupling constraints of multiple types of voltage regulators.A multi-timescale control strategy is proposed by considering the impact of voltage regulators on active-reactive EV energy consumption and PV energy consumption.Then,a four-stage voltage control optimization strategy is proposed for various types of voltage regulators with multiple time scales.Themulti-objective optimization is solved with the improvedDrosophila algorithmto realize the power fluctuation control of the distribution network and themulti-stage voltage control optimization.Simulation results validate that the proposed voltage control optimization strategy achieves the coordinated control of decentralized voltage control resources in the distribution network.It effectively reduces the voltage deviation of the distribution network while ensuring the energy demand of EV users and enhancing the stability and economic efficiency of the distribution network.展开更多
In this paper, we proposed an output voltage stabilization of a DC-DC Zeta converter using hybrid control. We modeled the Zeta converter under continuous conduction mode operation. We derived a switching control law t...In this paper, we proposed an output voltage stabilization of a DC-DC Zeta converter using hybrid control. We modeled the Zeta converter under continuous conduction mode operation. We derived a switching control law that brings the output voltage to the desired level. Due to infinite switching occurring at the desired level, we enhanced the switching control law by allowing a sizeable output voltage ripple. We derived mathematical models that allow one to choose the desired switching frequency. In practice, the existence of the non-ideal properties of the Zeta converter results in steady-state output voltage error. By analyzing the power loss in the zeta converter, we proposed an improved switching control law that eliminates the steady-state output voltage error. The effectiveness of the proposed method is illustrated with simulation results.展开更多
Uneven lithium deposition leading to lithium dendrite growth severely hampers the application of lithium-metal batteries.Modifying the collector with lithiophilic materials helps improve lithium deposition.For lithoph...Uneven lithium deposition leading to lithium dendrite growth severely hampers the application of lithium-metal batteries.Modifying the collector with lithiophilic materials helps improve lithium deposition.For lithophilic materials to modify the collector,the choice of cut-off voltage is very important.While excessively high cut-off voltages may compromise the stability of the modified layer and consequently disrupt ordered lithium deposition,conventional approaches typically employ lower cut-off voltages(particularly 0.1 V)to maintain modification layer stability.However,the 0.1 V cut-off voltage results in incomplete lithium stripping from the lithiophilic material surface.This phenomenon significantly diminishes the lithiophilic properties of the modified layer and consequently leads to substantial nucleation overpotential.Here,we propose to use a moderate cut-voltage stimulation effect to slow down the interfacial shielding effect of residual lithium metal on lithiophilic materials.By optimizing the cut-off voltage for the Cu@Sb_(2)S_(3)collector,the stability of the modified layer can be preserved while enabling the complete stripping of lithium metal from the surface of the lithophilic material.The asymmetric cell received the highest Coulombic efficiency(CE)when the lithium stripping cut-off voltage was set at 0.5 V relative to 0.1 and 2.0 V.At a current density of 1 mA cm^(-2)and a deposition capacity of1 m A h cm^(-2),the CE remained 98.6% at a cut-off voltage of 0.5 V after 140 cycles in an ether electrolyte without lithium nitrate.展开更多
The active equalization of lithium-ion batteries involves transferring energy from high-voltage cells to low-voltage cells,ensuring consistent voltage levels across the battery pack and maintaining safety.This paper p...The active equalization of lithium-ion batteries involves transferring energy from high-voltage cells to low-voltage cells,ensuring consistent voltage levels across the battery pack and maintaining safety.This paper presents a voltage balancing circuit and control method.First,a single capacitor method is used to design the circuit topology for energy transfer.Next,real-time voltage detection and control are employed to balance energy between cells.Finally,simulation and experimental results demonstrate the effectiveness of the proposed method,achieving balanced voltages of 3.97 V from initial voltages of 4.10,3.97,and 3.90 V.The proposed circuit is simple,reliable,and effectively prevents overcharge and overdischarge.展开更多
The utilization of hybrid energy systems has necessitated to address the various Power Quality(PQ)concerns in Distributed Generation(DG)networks.Owing to the emergence of DG networks in recent times,it is envisaged fo...The utilization of hybrid energy systems has necessitated to address the various Power Quality(PQ)concerns in Distributed Generation(DG)networks.Owing to the emergence of DG networks in recent times,it is envisaged for every utility⁃grid⁃tied system to generate and utilize harmonic⁃less electric power.Therefore,the present research critically evaluates the operation of a utility⁃grid coordinated DG system and studies its islanding operation under faulted conditions.To achieve this,an Anti⁃Islanding Protection(AIP)scheme is developed which is capable of controlling the frequency and voltage variations.This scheme is operated by a coordinated operation of multivibrators.Their operation continuously traces the pre⁃defined limits of voltage,reactive,and real power,and matches with their reference values to avoid mismatch.It is revealed that,if the mismatched values of real and reactive power exceeded its threshold value of 0.1 p.u.,then the islanding condition is detected.Especially,the proposed system is assessed in two modes:utility⁃grid and islanding modes.In utility⁃grid mode,reactive power compensation is obtained by the control of voltage and frequency signals.However,in islanding mode,the real power requirement of the connected load is obtained with reduced harmonics under unsymmetrical faulted conditions.Incremental Conductance(IC)based Maximum Power Point Tracking(MPPT)technique ensures the extraction of maximum power under varying and stochastically atmospheric conditions.Simulation results reveal that the AIP scheme promptly disconnects the utility grid from the DG network in the minimum time during dynamic variations in frequency and voltage to prevent islanding.It is justified that there is violation of the considered threshold limits even under the faulted condition.The strategy of the switchgear scheme ensures the minimum detection time of the islanding operation.Total Harmonic Distortion(THD)is 0.26%for grid voltage.It validates according to the IEEE⁃1547 standard which stipulates that the THD of grid voltage must be less than 5%.Overall,satisfactory and accurate results are obtained,which are compared with the IEEE⁃1547 standard for validation.展开更多
This paper deeply introduces a brand-new research method for the synchronous characteristics of DC microgrid bus voltage and an improved synchronous control strategy.This method mainly targets the problem of bus volta...This paper deeply introduces a brand-new research method for the synchronous characteristics of DC microgrid bus voltage and an improved synchronous control strategy.This method mainly targets the problem of bus voltage oscillation caused by the bifurcation behavior of DC microgrid converters.Firstly,the article elaborately establishes a mathematical model of a single distributed power source with hierarchical control.On this basis,a smallworld network model that can better adapt to the topology structure of DC microgrids is further constructed.Then,a voltage synchronization analysis method based on the main stability function is proposed,and the synchronous characteristics of DC bus voltage are deeply studied by analyzing the size of the minimum non-zero eigenvalue.In view of the situation that the line coupling strength between distributed power sources is insufficient to achieve bus voltage synchronization,this paper innovatively proposes a new improved adaptive controller to effectively control voltage synchronization.And the convergence of the designed controller is strictly proved by using Lyapunov’s stability theorem.Finally,the effectiveness and feasibility of the designed controller in this paper are fully verified through detailed simulation experiments.After comparative analysis with the traditional adaptive controller,it is found that the newly designed controller can make the bus voltages of each distributed power source achieve synchronization more quickly,and is significantly superior to the traditional adaptive controller in terms of anti-interference performance.展开更多
A feedback control system is needed to restrain plasma vertical displacement in EAST (Experimental Advanced Superconducting Toknmak). A fast control power supply excites active feedback coils, which produces a magne...A feedback control system is needed to restrain plasma vertical displacement in EAST (Experimental Advanced Superconducting Toknmak). A fast control power supply excites active feedback coils, which produces a magnetic field to control the plasma's displacement. With the development of EAST, new demands on the new fast control power supply have led to an enhanced ability of fast response and output current, as well as a new control mode. The structure of cascaded and paralleled H-bridges can meet the demand of extended capacity, and digital control can reMize current and voltage mixed control mode. The validity of the proposed scheme is confirmed by experiments.展开更多
基金funded by State Grid Corporation of China,grant number DQ30DK24001L。
文摘When the converter bus voltage of a voltage source converter-based high voltage direct current(VSC-HVDC)system drops below a certain predetermined threshold,the system enters low-voltage ride-through(LVRT)mode to avoid overcurrent and potential equipment failure,during which it operates as a controlled current source.The influence mechanism of LVRT control strategies on short-circuit current and overall system stability remains not yet fully and systematically investigated.First,this paper provides an overview of several LVRT strategies for VSC-HVDC systems and examines their effects on short-circuit current contribution.Next,it analyzes in detail the mechanisms through which active and reactive currents injected during LVRT impact system frequency stability,voltage stability,and synchronization stability.To address these interrelated issues,an optimized and comprehensive LVRT strategy incorporating short-circuit current constraints is proposed.The approach determines the active current ratio based on system frequency stability requirements and dynamically adjusts the active current recovery rate via phase control of the VSC-HVDC bus.The remaining capacity is allocated to reactive current support,thereby enhancing voltage and synchronization stability while maintaining sufficient short-circuit current margin and system frequency stability.Finally,simulations conducted on the PSS/E platform,using actual grid data from a selected cross-section system,validate convincingly the effectiveness of the proposed parameter optimization strategy for VSC-HVDC low-voltage ride-through.
基金supported by the Science and Technology Project of State Grid Jiangsu Electric Power Co.,Ltd.(J2024162).
文摘With the growing integration of renewable energy sources(RESs)and smart interconnected devices,conventional distribution networks have turned to active distribution networks(ADNs)with complex system model and power flow dynamics.The rapid fluctuation of RES power may easily result in frequent voltage violation issues.Taking the flexible RES reactive power as control variables,this paper proposes a two-layer control scheme with Koopman wide neural network(WNN)based model predictive control(MPC)method for optimal voltage regulation and network loss reduction.Based on Koopman operator theory,a data-driven WNN method is presented to fit a high-dimensional linear model of power flow.With the model,voltage and network loss sensitivities are computed analytically,and utilized for ADN partition and control model formulation.In the lower level,a dual-mode adaptive switching MPC strategy is put forward for optimal voltage control and network loss optimization in each individual partition to decide the RES reactive power.The upper level is to calculate the adjustment coefficients of the RES reactive power given in the low level by taking the coupling effects of different partitions into account,and then the final reactive power dispatches of RESs are obtained to realize optimal control of voltage and network loss.Simulation results on two ADNs demonstrate that the proposed strategy can reliably maintain the voltage at each node within the secure range,reduce network power losses,and enhance the overall system security and economic efficiency.
基金supported by the State Grid Shanxi Electric Power Company science and technology project“Research on Key Technologies for Voltage Stability Analysis and Control of UHV Transmission Sending-End Grid with Large-Scale Integration of Wind-Solar-Storage Systems”(520530240026).
文摘To address the issue of transient low-voltage instability in AC-DC hybrid power systems following large disturbances,conventional voltage assessment and control strategies typically adopt a sequential“assess-then-act”paradigm,which struggles to simultaneously meet the requirements for both high accuracy and rapid response.This paper proposes a transient voltage assessment and control method based on a hybrid neural network incorporated with an improved snow ablation optimization(ISAO)algorithm.The core innovation of the proposed method lies in constructing an intelligent“physics-informed and neural network-integrated”framework,which achieves the integration of stability assessment and control strategy generation.Firstly,to construct a highly correlated input set,response characteristics reflecting the system’s voltage stable/unstable states are screened.Simultaneously,the transient voltage severity index(TVSI)is introduced as a comprehensive metric to quantify the system’s post-disturbance transient voltage performance.Furthermore,the load bus voltage sensitivity index(LVSI)is defined as the ratio of the voltage change magnitude at a load node(or bus)to the change in the system-level TVSI,thereby pinpointing the response characteristics of critical load nodes.Secondly,both the transient voltage stability assessment result and its corresponding under-voltage load shedding(UVLS)control amount are jointly utilized as the outputs of the response-driven model.Subsequently,the snow ablation optimization(SAO)algorithm is enhanced using a good point set strategy and a Gaussian mutation strategy.This improved algorithm is then employed to optimize the key hyperparameters of the hybrid neural network.Finally,the superiority of the proposed method is validated on a modified CEPRI-36 system and an actual power grid case.Comparisons with various artificial intelligence methods demonstrate its significant advantages in model speed and accuracy.Additionally,when compared to traditional emergency control schemes and UVLS strategies,the proposed method exhibits exceptional rapidness and real-time capability in control decision-making.
基金supported in part by the National Natural Science Foundation of China(No.52177109)Key R&D Program of Hubei Province,China(No.2020BAB109).
文摘With the prevalence of renewable distributed energy resources(DERs)such as photovoltaics(PVs),modern active distribution networks(ADNs)suffer from voltage deviation and power quality issues.However,traditional voltage control methods often face a trade-off between efficiency and effectiveness,and rarely ensure robust voltage safety under typical state perturbations in practical distribution grids.In this paper,a robust model-free voltage regulation approach is proposed which simultaneously takes security and robustness into account.In this context,the voltage control problem is formulated as a constrained Markov decision process(CMDP).A safety-augmented multiagent deep deterministic policy gradient(MADDPG)algorithm is the trained to enable real-time collaborative optimization of ADNs,aiming to maintain nodal voltages within safe operational limits while minimizing total line losses.Moreover,a robust regulation loss is introduced to ensure reliable performance under various state perturbations in practical voltage controls.The proposed regulation algorithm effectively balance efficiency,safety,and robustness,and also demonstrates potential for generalizing these characteristics to other applications.Numerical studies vali-date the robustness of the proposed method under varying state perturbations on the IEEE test cases and the optimal integrated control performance when compared to other benchmarks.
基金supported in part by Smart Grid-National Science and Technology Major Project(No.2024ZD0801400)Science and technology projects of State Grid Corporation of China(No.52272224000V).
文摘The transient behavior of DC-link voltage(DCV)significantly affects the low-voltage ride-through for phase-locked loop(PLL)-based grid-connected doubly-fed induction generator(DFIG)systems.This study investigates the DCV transient behavior of a PLL-based DFIG system under asymmetrical grid faults.First,by considering the coupling characteristics of positive and negative sequence(PNS)components,a nonlinear largesignal model of DCV is developed.Furthermore,the transient characteristics of DCV under varying parameters are analyzed using phase trajectory diagrams.In addition,the transient stability(TS)mechanism of DCV during asymmetrical faults is examined through an en-ergy function approach.The analysis indicates that the transient instability of DCV is primarily associated with the control characteristics of PNS PLLs,while the TS level of DCV is mainly determined by the power coordination control between the rotor side converter and grid side converter.Moreover,a coordinated control strategy is proposed to enhance the TS of DCV under asymmet-rical grid faults.Finally,both simulation and experimental results are presented to validate the theoretical analysis and the effectiveness of the proposed strategy.
基金supported in part by the National Natural Science Foundation of China(51907057 and 52077072)Technological Leading Talent of Hunan province(2019RS3014).
文摘Voltage source converters(VSCs),equipped with Pf and Q-U droop characteristics,can support a power system from both frequency and voltage.Unfortunately,overcurrent and power angle instability are still challenging aspects of VSCs under fault conditions.Therefore,fault current limitation and power angle stability are essential conditions for the safe operation of a VSC.Thus,the transient characteristics of a VSC are analyzed to guide transient control.Then,a transient control method for a VSC,considering both fault current limitation and power angle stability,is proposed.With the proposed method,power angle stability is realized by optimizing the P-f controller.On the basis of power angle control,the Q-U controller and inner current controller are improved to effectively suppress the fault current.Finally,relevant tests are performed to verify the proposed method.
基金Supported by the Fundamental Research Funds for the Central Universities(2024ZYGXZR047)the National Natural Science Foundation of China(62373156)the Guangdong Basic and Applied Basic Research Foundation(2024A1515011736)。
文摘This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper constructs an internal model to learn the information of the states and input of the grid-connected inverter under steady state.Second,by utilizing the internal model principle,the paper turns the tracking control problem into the robust stabilization control problem based on some appropriate coordinate transformations.Then,The paper designs a dynamics state feedback control law to deal with this robust stabilization problem,and thus the solution of the robust current tracking control problem of three-phase grid-connected inverters can be obtained.This control method can ensure the asymptotic stability of the closedloop system.Finally,the paper illustrates the effectiveness of the proposed control approach through several groups of simulations,and compares it with the feedforward control method to verify the robustness of the proposed control method to uncertain parameters.
基金supported by the National Key Research and Development Program of China(No.2021YFB1507001).
文摘During sending-end faults in the hybrid cascaded HVDC(HC-HVDC)system,the transient voltage drop characteristics under the interaction of the AC/DC hybrid system remain unclear,and the reactive power support provided by the HC-HVDC to the sending-end AC system requires further investigation.To address this problem,the reactive power interaction coupling mechanism between the sending-end AC system and the HC-HVDC is revealed,and the transient voltage mathematical model considering fault severity and duration is established.Under the dynamic change of the AC system voltage,the difference between the reactive power provided only by the reactive power compensation devices and by the combined modular multilevel converters(MMC)and reactive power compensation devices is analyzed.It is concluded that using MMC to provide a proportion of reactive power enhances the reactive power support to the AC system during faults.Then,the transient voltage model considering the reactive power support of MMC is established,and the critical reactive power consumption of line commutated converter(LCC)is quantified.It is concluded that the reactive power consumption of LCC exceeding its critical value deteriorates the transient voltage.A coordinated support strategy for the sending-end AC system based on reactive power support of MMC and reactive power regulation of LCC is proposed.It can effectively address the challenge of weakened reactive power support to the AC system due to voltage drop,thereby preventing the unbalanced reactive power from deteriorating the transient voltage,and realizing active support of the tran-sient voltage.Finally,a simulation model is established on the PSCAD/EMTDC platform,and the simulation results validate the effectiveness of the proposed strategy in supporting the transient voltage,under different fault types,durations,severities,and locations.
基金supported in part by the National Natural Science Foundation of China(52077190)Cultivation Project for Basic Research and Innovation of Yanshan University(2021LGQN007)Science and Technology Project of Hebei Education Department(QN2024202).
文摘A multi-phase stacked interleaved buck converter(SIBC)is suitable for large-power water electrolysis applications due to its merits of high current output capability and zero output current ripple.However,the auxiliary converter used to compensate for the current ripple still has to withstand high voltage stress.This paper proposes a new multi-phase SIBC applied in the multicarrier energy system integrating electricity,heat,and hydrogen.A resistor-capacitor voltage divider is used to provide the input voltage of the auxiliary converter and as a heater for the thermal loads.Thus,the voltage stress of the auxiliary converter can be reduced at a low cost,and the size of the filter inductor can be reduced.With accurate voltage and current analysis and appropriate parameter design,the voltage stresses of both the switches and capacitors in the auxiliary converter can be further limited within an expected range.The experimental results verify the correctness of the topology,modulation,analysis,and design methods.A comparison with the conventional method is made in terms of cost,volume,and efficiency to show the advantages of the proposed method.
基金supported by the National Natural Science Foundation of China under Grant 52277184 and Grant 52277183.
文摘The transient synchronization stability of grid-forming converters(GFMCs)is significantly challenged under grid voltage sags.Continuous efforts have been devoted to analyzing the GFMC transient stability,with limited attention paid to the impacts of control loop dynamics.However,the complex control dynamics,especially the interactions between the active/reactive power control loops and the current saturation process(CSP),are crucial for accurately describing the transient behavior and evaluating the stability.Thus,in this study,a new large-signal GFMC model is established,considering the reactive power control(RPC)with different kinds of controllers and the CSP simultaneously.It is revealed that GFMC does not switch to the current-limited mode immediately,and the dynamics of RPC further affect the transient behavior before the current limiting significantly.Hence,the complex control dynamics can alter the mode switching point of current saturation,thereby increasing the risk of loss of synchronization(LOS).Based on the above findings,comprehensive comparisons of typical RPC controllers are presented to facilitate practical engineering applications.A unified stability enhancement method is proposed for solving the problem of LOS.Finally,experiments validate the correctness of the analysis and the effectiveness of the proposed control strategy.
基金supported in part by the National Natural Science Foundation of China under Grant 52477060in part by the Tianjin Natural Science Foundation Project under Grant 24JCZDJC00250in part by the Zhejiang Leading Innovation and Entrepreneurship Team Project under Grant 2024R01012.
文摘In position-sensorless brushless direct current(DC)motors(BLDCMs)fed by a four-switch three-phase(FSTP)inverter,only two phases are fully controlled,while the remaining phase is tied to the midpoint of the split DC-link capacitors.The voltage pulses required by inductance-based initial position detection can cause unequal discharge of the series capacitors,shifting the neutral-point voltage away from half of DC-link voltage(U_(dc)/2).This neutral-point drift breaks the spatial symmetry of the inverter voltage vectors,so the 360°electrical period can no longer be evenly partitioned into six sectors during initial rotor position detection.To address this issue,this paper proposes a detection-pulse injection sequence that explicitly accounts for the asymmetric voltage vectors of the FSTP inverter.With the proposed sequence,the initial rotor position can be identified within a 30°electrical sector.The method requires no additional voltage or current sensors,and experimental results confirm its feasibility.
文摘Fluctuating voltage levels in power grids necessitate automatic voltage regulators(AVRs)to ensure stability.This study examined the modeling and control of AVR in hydroelectric power plants using model predictive control(MPC),which utilizes an extensive mathe-matical model of the voltage regulation system to optimize the control actions over a defined prediction horizon.This predictive feature enables MPC to minimize voltage deviations while accounting for operational constraints,thereby improving stability and performance under dynamic conditions.Thefindings were compared with those derived from an optimal proportional integral derivative(PID)con-troller designed using the artificial bee colony(ABC)algorithm.Although the ABC-PID method adjusts the PID parameters based on historical data,it may be difficult to adapt to real-time changes in system dynamics under constraints.Comprehensive simulations assessed both frameworks,emphasizing performance metrics such as disturbance rejection,response to load changes,and resilience to uncertainties.The results show that both MPC and ABC-PID methods effectively achieved accurate voltage regulation;however,MPC excelled in controlling overshoot and settling time—recording 0.0%and 0.25 s,respectively.This demonstrates greater robustness compared to conventional control methods that optimize PID parameters based on performance criteria derived from actual system behavior,which exhibited settling times and overshoots exceeding 0.41 s and 5.0%,respectively.The controllers were implemented using MATLAB/Simulink software,indicating a significant advancement for power plant engineers pursuing state-of-the-art automatic voltage regulations.
基金funded by the State Grid Corporation Science and Technology Project(5108-202218280A-2-391-XG).
文摘The high proportion of uncertain distributed power sources and the access to large-scale random electric vehicle(EV)charging resources further aggravate the voltage fluctuation of the distribution network,and the existing research has not deeply explored the EV active-reactive synergistic regulating characteristics,and failed to realize themulti-timescale synergistic control with other regulatingmeans,For this reason,this paper proposes amultilevel linkage coordinated optimization strategy to reduce the voltage deviation of the distribution network.Firstly,a capacitor bank reactive power compensation voltage control model and a distributed photovoltaic(PV)activereactive power regulationmodel are established.Additionally,an external characteristicmodel of EVactive-reactive power regulation is developed considering the four-quadrant operational characteristics of the EVcharger.Amultiobjective optimization model of the distribution network is then constructed considering the time-series coupling constraints of multiple types of voltage regulators.A multi-timescale control strategy is proposed by considering the impact of voltage regulators on active-reactive EV energy consumption and PV energy consumption.Then,a four-stage voltage control optimization strategy is proposed for various types of voltage regulators with multiple time scales.Themulti-objective optimization is solved with the improvedDrosophila algorithmto realize the power fluctuation control of the distribution network and themulti-stage voltage control optimization.Simulation results validate that the proposed voltage control optimization strategy achieves the coordinated control of decentralized voltage control resources in the distribution network.It effectively reduces the voltage deviation of the distribution network while ensuring the energy demand of EV users and enhancing the stability and economic efficiency of the distribution network.
文摘In this paper, we proposed an output voltage stabilization of a DC-DC Zeta converter using hybrid control. We modeled the Zeta converter under continuous conduction mode operation. We derived a switching control law that brings the output voltage to the desired level. Due to infinite switching occurring at the desired level, we enhanced the switching control law by allowing a sizeable output voltage ripple. We derived mathematical models that allow one to choose the desired switching frequency. In practice, the existence of the non-ideal properties of the Zeta converter results in steady-state output voltage error. By analyzing the power loss in the zeta converter, we proposed an improved switching control law that eliminates the steady-state output voltage error. The effectiveness of the proposed method is illustrated with simulation results.
基金support from the National Natural Science Foundation of China(22179006)the National Key Research and Development Program of China(2024YFF0505900)+1 种基金the Key Research and Development Program of Henan province,China(231111242500)the SINOPEC project(223128)。
文摘Uneven lithium deposition leading to lithium dendrite growth severely hampers the application of lithium-metal batteries.Modifying the collector with lithiophilic materials helps improve lithium deposition.For lithophilic materials to modify the collector,the choice of cut-off voltage is very important.While excessively high cut-off voltages may compromise the stability of the modified layer and consequently disrupt ordered lithium deposition,conventional approaches typically employ lower cut-off voltages(particularly 0.1 V)to maintain modification layer stability.However,the 0.1 V cut-off voltage results in incomplete lithium stripping from the lithiophilic material surface.This phenomenon significantly diminishes the lithiophilic properties of the modified layer and consequently leads to substantial nucleation overpotential.Here,we propose to use a moderate cut-voltage stimulation effect to slow down the interfacial shielding effect of residual lithium metal on lithiophilic materials.By optimizing the cut-off voltage for the Cu@Sb_(2)S_(3)collector,the stability of the modified layer can be preserved while enabling the complete stripping of lithium metal from the surface of the lithophilic material.The asymmetric cell received the highest Coulombic efficiency(CE)when the lithium stripping cut-off voltage was set at 0.5 V relative to 0.1 and 2.0 V.At a current density of 1 mA cm^(-2)and a deposition capacity of1 m A h cm^(-2),the CE remained 98.6% at a cut-off voltage of 0.5 V after 140 cycles in an ether electrolyte without lithium nitrate.
基金funded by the Basic Science(Natural Science)Research Project of Colleges and Universities in Jiangsu Province,Grant Number 22KJD470002.
文摘The active equalization of lithium-ion batteries involves transferring energy from high-voltage cells to low-voltage cells,ensuring consistent voltage levels across the battery pack and maintaining safety.This paper presents a voltage balancing circuit and control method.First,a single capacitor method is used to design the circuit topology for energy transfer.Next,real-time voltage detection and control are employed to balance energy between cells.Finally,simulation and experimental results demonstrate the effectiveness of the proposed method,achieving balanced voltages of 3.97 V from initial voltages of 4.10,3.97,and 3.90 V.The proposed circuit is simple,reliable,and effectively prevents overcharge and overdischarge.
文摘The utilization of hybrid energy systems has necessitated to address the various Power Quality(PQ)concerns in Distributed Generation(DG)networks.Owing to the emergence of DG networks in recent times,it is envisaged for every utility⁃grid⁃tied system to generate and utilize harmonic⁃less electric power.Therefore,the present research critically evaluates the operation of a utility⁃grid coordinated DG system and studies its islanding operation under faulted conditions.To achieve this,an Anti⁃Islanding Protection(AIP)scheme is developed which is capable of controlling the frequency and voltage variations.This scheme is operated by a coordinated operation of multivibrators.Their operation continuously traces the pre⁃defined limits of voltage,reactive,and real power,and matches with their reference values to avoid mismatch.It is revealed that,if the mismatched values of real and reactive power exceeded its threshold value of 0.1 p.u.,then the islanding condition is detected.Especially,the proposed system is assessed in two modes:utility⁃grid and islanding modes.In utility⁃grid mode,reactive power compensation is obtained by the control of voltage and frequency signals.However,in islanding mode,the real power requirement of the connected load is obtained with reduced harmonics under unsymmetrical faulted conditions.Incremental Conductance(IC)based Maximum Power Point Tracking(MPPT)technique ensures the extraction of maximum power under varying and stochastically atmospheric conditions.Simulation results reveal that the AIP scheme promptly disconnects the utility grid from the DG network in the minimum time during dynamic variations in frequency and voltage to prevent islanding.It is justified that there is violation of the considered threshold limits even under the faulted condition.The strategy of the switchgear scheme ensures the minimum detection time of the islanding operation.Total Harmonic Distortion(THD)is 0.26%for grid voltage.It validates according to the IEEE⁃1547 standard which stipulates that the THD of grid voltage must be less than 5%.Overall,satisfactory and accurate results are obtained,which are compared with the IEEE⁃1547 standard for validation.
基金supported by the National Natural Science Foundation of China(Nos.51767017 and 51867015)the Basic Research and Innovation Group Project of Gansu(No.18JR3RA13)the Major Science and Technology Project of Gansu(No.19ZD2GA003).
文摘This paper deeply introduces a brand-new research method for the synchronous characteristics of DC microgrid bus voltage and an improved synchronous control strategy.This method mainly targets the problem of bus voltage oscillation caused by the bifurcation behavior of DC microgrid converters.Firstly,the article elaborately establishes a mathematical model of a single distributed power source with hierarchical control.On this basis,a smallworld network model that can better adapt to the topology structure of DC microgrids is further constructed.Then,a voltage synchronization analysis method based on the main stability function is proposed,and the synchronous characteristics of DC bus voltage are deeply studied by analyzing the size of the minimum non-zero eigenvalue.In view of the situation that the line coupling strength between distributed power sources is insufficient to achieve bus voltage synchronization,this paper innovatively proposes a new improved adaptive controller to effectively control voltage synchronization.And the convergence of the designed controller is strictly proved by using Lyapunov’s stability theorem.Finally,the effectiveness and feasibility of the designed controller in this paper are fully verified through detailed simulation experiments.After comparative analysis with the traditional adaptive controller,it is found that the newly designed controller can make the bus voltages of each distributed power source achieve synchronization more quickly,and is significantly superior to the traditional adaptive controller in terms of anti-interference performance.
基金supported by ITER Program of China(973 Program)(No.2011GB109002)National Natural Science Foundation of China(No.11275056)Hefei University of Technology Doctor Research Foundation of China(No.2011HGBZ1292)
文摘A feedback control system is needed to restrain plasma vertical displacement in EAST (Experimental Advanced Superconducting Toknmak). A fast control power supply excites active feedback coils, which produces a magnetic field to control the plasma's displacement. With the development of EAST, new demands on the new fast control power supply have led to an enhanced ability of fast response and output current, as well as a new control mode. The structure of cascaded and paralleled H-bridges can meet the demand of extended capacity, and digital control can reMize current and voltage mixed control mode. The validity of the proposed scheme is confirmed by experiments.