Axial Shock in a Cylindrical Plasma with Current
1
作者 胡业民 胡希伟 何勇 《Plasma Science and Technology》 SCIE EI CAS CSCD 2006年第5期524-530,共7页
Hugoniot relations of a two-dimensional axial shock with current and magnetic field in a cylindrical shock tube were investigated by a numerical method. The radial profiles of the magnetic field, electric current, pre... Hugoniot relations of a two-dimensional axial shock with current and magnetic field in a cylindrical shock tube were investigated by a numerical method. The radial profiles of the magnetic field, electric current, pressures, flow velocities and temperatures between the up- and down-stream radial force-balanced plasma of the shock were revealed by numerical analysis. It is clearly found that the axial shock can lead to two effects: one is an inverse skin effect (i.e., the current density rises towards the center of the conductor), the another is a reversed current effect which occurs near the edge and about a half radius. It is also found that the radial gradient of pressure, density and temperature all become very large near the center due to the axial shock. 展开更多
关键词 axial shock reversed current effect inverse skin effect
在线阅读 下载PDF
基于双电流突变量比值的含光伏电源低压配电网触电故障检测和定位方法
2
作者 李军 朱劲涛 +3 位作者 张玉琼 吕干云 刘克天 黄嘉伟 《电力系统保护与控制》 北大核心 2025年第18期97-108,共12页
针对分布式光伏接入的低压配电网中,剩余电流波形复杂、幅值随机多变,现有剩余电流保护装置频繁误动作、难以投入使用的问题,提出剩余电流与重复接地点电流突变量的比值结合剩余电流动作整定值的双重判据。首先,分析含光伏电源的TN-C-S... 针对分布式光伏接入的低压配电网中,剩余电流波形复杂、幅值随机多变,现有剩余电流保护装置频繁误动作、难以投入使用的问题,提出剩余电流与重复接地点电流突变量的比值结合剩余电流动作整定值的双重判据。首先,分析含光伏电源的TN-C-S系统发生触电故障时、重复接地点和负荷数量逐渐增加的情况下剩余电流的组成成分以及变化情况,提出剩余电流与重复接地点电流突变量的比值的阈值作为触电判据。接着分析重复接地点对触电电流分流的影响,提出利用比值的平均值大小定位故障区段。通过仿真验证,所提判据可以准确检测触电故障,抗干扰能力强,有效改善保护装置的误动作问题,实现不同故障位置下的故障区段准确定位。 展开更多
关键词 光伏电源 低压配电网 剩余电流 生物触电 故障定位
在线阅读 下载PDF
一种基于小波包分解和特征分量动态优选的剩余电流动作保护方法 被引量:3
3
作者 高伟 陈渊隆 黄天富 《仪器仪表学报》 北大核心 2025年第1期311-323,共13页
目前剩余电流动作保护装置(RCDs)仅依靠固定阈值作为动作判据,在参数配合整定不合理、谐波含量大和高频电弧脉冲等因素的影响下,存在拒动和误动的风险,且无法有效辨识出真正的触电事件。对此,提出了一种基于小波包分解和特征分量动态优... 目前剩余电流动作保护装置(RCDs)仅依靠固定阈值作为动作判据,在参数配合整定不合理、谐波含量大和高频电弧脉冲等因素的影响下,存在拒动和误动的风险,且无法有效辨识出真正的触电事件。对此,提出了一种基于小波包分解和特征分量动态优选的新型RCD动作判据,可快速识别出常规接地故障、触电、电弧等多种类型的故障。首先,利用高阶统计量中对信号冲击敏感的峭度值捕捉故障起始时刻,并通过计算该时刻前后各一周波差分剩余电流信号的能量比,以实时甄别异常状态。其次,收集故障前一周波和故障启动后三周波的差分剩余电流信号进行小波包分解,融合各节点分量的峭度值、小波包能量比与样本熵特征为动态优选指标(DOI),并结合各分量DOI的贡献度重构低频与高频信号,以突出各故障类型在不同频段电流波形中的故障特征信息。最后,提取不同重构信号的电气量特征,透过双层链式规则实现故障精准分类。该方法已在RCD样机上进行验证,实验结果表明,其在低压交流配电网的串联电弧、接地电弧、触电故障以及常规接地故障检测中表现优异,识别率达到97.52%,平均诊断时间为79.6 ms,能够满足RCDs所要求的灵敏性和可靠性,有效提升了RCDs的实际应用价值。 展开更多
关键词 剩余电流动作保护装置 触电故障 串联电弧 小波包分解 特征分量动态优选
原文传递
多因素影响下动物体的直流触电电流响应特性分析
4
作者 朱鸿章 吴传平 +4 位作者 周洋 廖秀晶 周天念 李健 陈可 《电力系统保护与控制》 北大核心 2025年第12期33-44,共12页
针对直流触电电流响应特性尚不明晰的问题,剖析了多因素下动物体直流触电电流的幅值、峰值上升时间、滑动斜率的时域响应特性,同时提出了一种变分模态与奇异值分解(variational mode decomposition and singular value decomposition,VM... 针对直流触电电流响应特性尚不明晰的问题,剖析了多因素下动物体直流触电电流的幅值、峰值上升时间、滑动斜率的时域响应特性,同时提出了一种变分模态与奇异值分解(variational mode decomposition and singular value decomposition,VMD-SVD)的直流触电电流时频响应特性分析方法。首先通过对不同触电方式、触电电压、皮肤表面干湿度、触电路径和动物体质量工况下的活体猪直流触电电流幅值、滑动斜率、峰值上升时间时频响应特性进行分析,揭示了触电电流响应特征与多因素之间的变化规律。同时定量地分析了各因素对活体猪直流触电电流特性的影响,揭示了动物体质量和直流触电电压与电流幅值间的定量关系。最后采用VMD-SVD分析了多因素下触电前/后的活体猪直流触电电流时频响应特性,揭示了触电前/后最大奇异值和奇异熵特征量存在明显差异,且多因素影响下最大奇异值和奇异熵特征量差异<10%。 展开更多
关键词 多因素 直流触电电流 响应特性 滑动斜率 变分模态与奇异值分解
在线阅读 下载PDF
脉冲电流对AZ31镁合金激光冲击强化效果的影响
5
作者 李进 胡鸿彪 +4 位作者 李博文 王文泉 赵新甜 郑宏宇 王宗申 《表面技术》 北大核心 2025年第17期137-149,共13页
目的 改善镁合金的激光冲击强化效果。方法 借助外加电场辅助镁合金的激光冲击强化过程。通过表面形貌分析,显微硬度和残余应力的测量,室温单向拉伸实验及断口分析,金相组织观察和电子背散射衍射等,对比研究预处理和同步处理2种脉冲电... 目的 改善镁合金的激光冲击强化效果。方法 借助外加电场辅助镁合金的激光冲击强化过程。通过表面形貌分析,显微硬度和残余应力的测量,室温单向拉伸实验及断口分析,金相组织观察和电子背散射衍射等,对比研究预处理和同步处理2种脉冲电流施加方式,分析脉冲电流对激光冲击强化AZ31镁合金的表面完整性、力学性能、微观组织等的影响机理。结果 试样温度随着电流密度的增大而逐渐升高,并在90 A/mm^(2)时达到最大值,约为177.1℃。预处理试样的表面粗糙度约为9.1μm,同步处理试样的表面冲击凹坑分布更均匀,其粗糙度更低(约为7.5μm),试样的表面和截面的硬度均得到提高。退火态原始试样的表面残余应力状态表现为拉应力(约为24.8 MPa),经脉冲电流辅助激光冲击强化后转变为压应力(约为-40.0 MPa)。在电流密度为60 A/mm^(2)时,试样的拉伸性能较优,预处理试样的抗拉强度和屈服强度分别为306.2、273.5 MPa,同步处理试样的抗拉强度和屈服强度分别为298.3、269.5 MPa,断后伸长率分别为11.2%、18.7%。结论 在电-热-力多场耦合条件下,借助脉冲电流的热效应和电子风等非热效应,激光冲击强化AZ31镁合金的表面完整性得到改善,动态回复和再结晶过程得到加强,大角度晶界比例得到提高,晶粒细化效果更显著,残余压应力水平和力学性能进一步提升。 展开更多
关键词 激光冲击强化 脉冲电流 表面完整性 力学性能 微观组织 AZ31镁合金
在线阅读 下载PDF
会计稳健性与贸易争端的资本市场冲击
6
作者 肖泽华 《财贸研究》 北大核心 2025年第5期78-91,共14页
从短期和长期两个维度研究会计稳健性如何影响贸易争端事件的资本市场冲击,运用中国A股上市企业数据,以2018年美国单方面加征关税政策作为事件对象,研究发现会计稳健性强的企业受贸易争端冲击的短期累计超额收益率更低,长期购买并持有... 从短期和长期两个维度研究会计稳健性如何影响贸易争端事件的资本市场冲击,运用中国A股上市企业数据,以2018年美国单方面加征关税政策作为事件对象,研究发现会计稳健性强的企业受贸易争端冲击的短期累计超额收益率更低,长期购买并持有超额收益率更高。上述结论经中美“和谈”的反事实检验,美国商务部将企业列入实体清单这一单边贸易保护主义行为的检验,及其他稳健性测试后依然成立。公司当前估值越高,会计稳健性对贸易争端短期市场反应的负面影响越强;投资者短视现象越严重,会计稳健性对贸易争端长期市场反应的正面影响越明显。此外,当研发投资水平较高时,会计稳健性使公司受贸易争端冲击所产生的短期负面市场反应更强,长期正面市场反应更强。研究结论为会计信息如何服务中国防范贸易争端造成的重大经济、金融风险提供了理论指引。 展开更多
关键词 会计稳健性 贸易争端 资本市场冲击 公司估值 投资者视野
在线阅读 下载PDF
基于拉氏变换的变频器IT系统的人身触电电流暂态分析方法
7
作者 袁广忠 柳海生 +2 位作者 杨志佳 孙宝金 张伟 《矿业科学学报》 北大核心 2025年第4期638-647,共10页
为了解决露天煤矿消防低压变频IT供电系统发生人身触电事故时,由脉冲调制波造成的人身电流有效值难以计算的问题,提出一种基于拉氏变换的人身触电电流暂态分析方法,通过建立分段线性模型(PLM)分析变频器输入侧和输出侧的人身触电电流有... 为了解决露天煤矿消防低压变频IT供电系统发生人身触电事故时,由脉冲调制波造成的人身电流有效值难以计算的问题,提出一种基于拉氏变换的人身触电电流暂态分析方法,通过建立分段线性模型(PLM)分析变频器输入侧和输出侧的人身触电电流有效值、搭建MATLAB/Siumlink仿真模型,探究变频器两侧的分布参数、载波频率、输出频率以及输出侧负载对触电电流的影响特征。结果表明:分布电容为0.01~1.0μF、输出频率为30~60 Hz、载波频率为1~3 kHz的情况下,人身触电电流的大小与每相对地分布的电容和变频器载波频率均呈正相关,而与变频器输出频率、输出侧所接负载关系不大。 展开更多
关键词 IT系统 拉氏变换 人身触电电流 分段线性模型 变频器
在线阅读 下载PDF
线性涡流制动装置的结构强度研究
8
作者 王可 王立超 +2 位作者 王文静 王立宁 高立群 《铁道机车车辆》 北大核心 2025年第1期50-56,共7页
高速列车线性涡流制动装置载荷工况复杂,为了工程应用的安全性,应对产品结构强度进行全面分析。通过结构特点及载荷工况分析,利用有限元软件进行各种典型工况下的强度计算,研究振动、冲击试验及台架试验方法,并对强度仿真与试验结果进... 高速列车线性涡流制动装置载荷工况复杂,为了工程应用的安全性,应对产品结构强度进行全面分析。通过结构特点及载荷工况分析,利用有限元软件进行各种典型工况下的强度计算,研究振动、冲击试验及台架试验方法,并对强度仿真与试验结果进行对比。研究结果表明,目前试验设备无法满足涡流制动装置的3类振动冲击试验要求,可采用整机2类振动、冲击试验和主体框架强度试验相结合的方法考核产品结构完整性;涡流制动装置强度计算与试验结果一致性较好,验证了产品结构强度计算与试验的有效性;各工况下涡流制动装置的静强度、疲劳强度计算结果均符合相关标准要求,研制的产品通过了相关试验考核。 展开更多
关键词 高速列车 线性涡流制动装置 有限元仿真 振动、冲击试验
在线阅读 下载PDF
“双碳”目标下低压漏电保护技术的发展研究
9
作者 李敏 熊焘 +4 位作者 李燕 黄麒衡 梁栋 黄研洲 梁战 《现代建筑电气》 2025年第4期18-24,共7页
“双碳”目标下,负载类型越来越复杂,漏电波形和频率呈现多样化,对电力系统的安全性与可靠性造成了更大冲击,因此对各种漏电形式保护技术的研究显得尤为重要。以4种漏电波形和频率为研究对象,总结归纳出4种漏电形式的保护技术各自对应... “双碳”目标下,负载类型越来越复杂,漏电波形和频率呈现多样化,对电力系统的安全性与可靠性造成了更大冲击,因此对各种漏电形式保护技术的研究显得尤为重要。以4种漏电波形和频率为研究对象,总结归纳出4种漏电形式的保护技术各自对应的负载种类。同时,对智慧微型断路器中漏电保护技术的融入做了介绍,以及电力系统接地类型对漏电保护的影响做了分析。对该领域的相关研究具有一定的参考价值。 展开更多
关键词 双碳 直流负载 剩余电流波形 无法识别 复杂波形 电击保护
在线阅读 下载PDF
断路器选相投切系统在换流站中的应用研究 被引量:2
10
作者 李海涛 董辉波 +3 位作者 邓劲东 程骁 刘东超 须雷 《自动化仪表》 CAS 2024年第9期121-126,共6页
在换流站滤波器组及换流变压器配置断路器选相投切系统,可改善断路器开合暂态过程,在取消合闸电阻工况下仍可避免对电力设备及系统造成冲击。基于多个换流站选相投切工程实施及调试经验,进行了换流站选相投切系统应用的调查。介绍了选... 在换流站滤波器组及换流变压器配置断路器选相投切系统,可改善断路器开合暂态过程,在取消合闸电阻工况下仍可避免对电力设备及系统造成冲击。基于多个换流站选相投切工程实施及调试经验,进行了换流站选相投切系统应用的调查。介绍了选相投切系统构成、选相投切要求、断路器配套及预测试方法等。重点针对滤波器组、换流变压器的选相投切应用,总结了控制策略、选相投切系统带电冲击试验,及工程使用中需重点关注的问题、设备运维要求等,为相关技术人员提供参考。试点工程在特高压断路器中创新性地采用取消合闸电阻、增设选相合闸的专项改造方案。断路器选相投切系统总体运行效果良好,为技术的推广积累了工程运行经验。 展开更多
关键词 换流站 滤波器 换流变压器 高压/特高压直流输电 暂态冲击 选相投切
在线阅读 下载PDF
Interplanetary shock-associated aurora 被引量:1
11
作者 LIU Jianjun HU Hongqiao +1 位作者 HAN Desheng YANG Huigen 《Advances in Polar Science》 CSCD 2019年第1期11-23,共13页
Interplanetary shocks or solar wind pressure pulses have prompted impacts on Earth's magnetospheric and ionospheric environment, especially in causing dynamic changes to the bright aurora in the polar ionosphere. ... Interplanetary shocks or solar wind pressure pulses have prompted impacts on Earth's magnetospheric and ionospheric environment, especially in causing dynamic changes to the bright aurora in the polar ionosphere. The auroral phenomenon associated with shock impingements, referred to as shock aurora, exhibits distinct signatures differing from other geophysical features on the dayside polar ionosphere. Shock aurora provides a direct manifestation of the solar wind–magnetosphere–ionosphere interaction. Imagers onboard satellites can obtain the associated large-scale auroral characteristics during shock impingement on the magnetopause. Therefore, auroral data from satellites are very useful for surveying the comprehensive features of shock aurora and their general evolution. Nonetheless, the ground-based high temporal-spatial resolution all-sky imagers installed at scientific stations play an essential role in revealing medium-and small-scale characteristics of shock aurora. Here, we focus on shock aurora imaging signatures measured by imagers onboard satellites and ground-based all-sky imagers. 展开更多
关键词 INTERPLANETARY shock SUDDEN IMPULSE shock AURORA wave-particle interaction field-aligned current
在线阅读 下载PDF
不均衡小样本下多特征优化选择的生命体触电故障识别方法 被引量:6
12
作者 高伟 饶俊民 +1 位作者 全圣鑫 郭谋发 《电工技术学报》 EI CSCD 北大核心 2024年第7期2060-2071,共12页
针对现有的剩余电流保护装置无法有效识别触电事故的问题,该文提出了一种不均衡小样本下多特征优化选择的生命体触电故障识别方法。首先通过变分自编码器(VAE)对实验收集到的生命体触电小样本数据进行增殖以实现正负样本均衡;然后在时... 针对现有的剩余电流保护装置无法有效识别触电事故的问题,该文提出了一种不均衡小样本下多特征优化选择的生命体触电故障识别方法。首先通过变分自编码器(VAE)对实验收集到的生命体触电小样本数据进行增殖以实现正负样本均衡;然后在时域上提取能够反映波形动态变化特性的23个特征量,并利用高斯核Fisher判别分析(GKFDA)与最大信息系数(MIC)法从中选择最优表达特征组;最后,提出基于遗忘因子的在线顺序极限学习机(FOS-ELM)算法实现生命体触电行为的鉴别。实验结果表明,所提方法利用不均衡小样本触电数据集就可以训练出一个优秀的分类模型,诊断准确率可达98.75%,诊断时间仅为1.33 ms。其优良的性能结合在线增量式学习分类器设计,使得模型具备新知识学习能力,具有极好的工程应用前景。 展开更多
关键词 剩余电流保护装置 生命体触电故障 多特征优化选择 基于遗忘因子的在线顺序 极限学习机(FOS-ELM) 不均衡小样本
在线阅读 下载PDF
电冲击预处理下的316不锈钢构筑成形界面愈合行为模拟与实验研究
13
作者 杨桢宇 韩天 +1 位作者 邓加东 钱东升 《锻压技术》 CAS CSCD 北大核心 2024年第9期138-145,共8页
为保证构筑界面的高质量连接,提出了在高温变形调控界面愈合的基础上引入电冲击前处理的方法来促进构筑界面的愈合,并通过对316不锈钢高温变形前进行电冲击预处理的仿真和实验,揭示电冲击前处理对构筑界面愈合程度的作用规律。研究结果... 为保证构筑界面的高质量连接,提出了在高温变形调控界面愈合的基础上引入电冲击前处理的方法来促进构筑界面的愈合,并通过对316不锈钢高温变形前进行电冲击预处理的仿真和实验,揭示电冲击前处理对构筑界面愈合程度的作用规律。研究结果表明,提高电冲击前处理时的电流密度,构筑成形试样界面的愈合效果逐步提高,但电冲击前处理的电流密度不宜过大,关键在于更大程度地实现构筑界面处的温度梯度变化,产生向中心挤压的热压应力,才能够促进构筑界面产生局部预连接。 展开更多
关键词 电冲击 电流密度 构筑成形 界面愈合 316不锈钢
原文传递
高低温下颜色稳定的汽车氛围灯设计
14
作者 周静 《照明工程学报》 2024年第6期75-83,共9页
本研究提出了一种能耐受高低温冲击,在全工作温度范围内保持颜色稳定的汽车氛围灯方案。目前采用具备PWM接口的微控制器来驱动外部恒流电路,通过调整PWM占空比来设定恒流电路的平均电流水平,进而控制LED的亮度。由于恒流电路中的元器件... 本研究提出了一种能耐受高低温冲击,在全工作温度范围内保持颜色稳定的汽车氛围灯方案。目前采用具备PWM接口的微控制器来驱动外部恒流电路,通过调整PWM占空比来设定恒流电路的平均电流水平,进而控制LED的亮度。由于恒流电路中的元器件参数会随温度改变,即影响LED的驱动电流,且LED的光通量随温度变化而波动,导致氛围灯在不同温度环境下的亮度和颜色出现差异。为解决这一问题,本方案对恒流电路的元件进行了精细选型,并引入了电流补偿机制,以确保汽车氛围灯在全工作温度范围内保持亮度和颜色的一致性。 展开更多
关键词 多路恒流电路 耐温度冲击 光通量一致性 颜色稳定 汽车氛围灯
在线阅读 下载PDF
变频器抗晃电的直流支撑技术研究
15
作者 杨育峰 《通信电源技术》 2024年第3期58-60,共3页
随着现代社会的蓬勃发展,人们的生活与社会生产都需要使用大量电能。尤其是化工、冶金等连续型生产企业,在其生产过程中要求供电不中断,为生产活动的工艺流程提供持续不断的电流。变频器在工业生产中具有重要作用,能够通过调节电源频率... 随着现代社会的蓬勃发展,人们的生活与社会生产都需要使用大量电能。尤其是化工、冶金等连续型生产企业,在其生产过程中要求供电不中断,为生产活动的工艺流程提供持续不断的电流。变频器在工业生产中具有重要作用,能够通过调节电源频率来控制机械设备的速度,满足生产过程中对不同设备的调速需求。系统电压的短时波动将导致变频器失压停机,进而造成整条生产线停机,给生产企业造成了严重的经济损失,因此强化变频器抗晃电具有一定的现实意义。通过动能缓冲技术、直流支撑技术来实现变频器的抗晃电,能够为企业的生产活动提供稳定电流,保障电力设备的安全性,有助于提高生产企业的经济效益。通过分析变频器抗晃电的直流支撑技术路线,研究Boost技术、高频变压技术以及晶闸管技术等抗晃电技术方案的使用原理及其优缺点。 展开更多
关键词 变频器 抗晃电 直流支撑技术 电力设备
在线阅读 下载PDF
一起220kV变压器绕组变形缺陷的诊断分析与解体验证 被引量:14
16
作者 于洋 耿宁 +4 位作者 陈勇强 毛建波 刘琳 杨超 魏雪敏 《高压电器》 CAS CSCD 北大核心 2016年第8期172-176,183,共6页
文中介绍了一起停电试验发现的220 k V变压器低压绕组变形缺陷,为变压器累积效应的理论研究和变压器故障检测的试验研究提供现场数据诊断案例。试验检修人员首先根据变压器短路阻抗试验和绕组变形试验结果,推断出低压绕组发生不同程度变... 文中介绍了一起停电试验发现的220 k V变压器低压绕组变形缺陷,为变压器累积效应的理论研究和变压器故障检测的试验研究提供现场数据诊断案例。试验检修人员首先根据变压器短路阻抗试验和绕组变形试验结果,推断出低压绕组发生不同程度变形;并结合该变压器历年遭受短路冲击后的色谱分析试验结果,综合分析、诊断发生变形的原因,主要由于低压侧短路电流冲击及绕组变形的累积效应。通过返厂解体发现,其低压绕组发生不同程度的变形,并存在过热现象,验证了试验和诊断结果。通过变压器绕组变形试验诊断,有效避免了一起设备潜伏性故障的发生,并给出变压器日常维护检修的注意事项及相关建议。 展开更多
关键词 变压器绕组变形 累积效应 色谱分析 短路冲击
在线阅读 下载PDF
基于参数优化的最小二乘支持向量机触电电流检测方法 被引量:37
17
作者 韩晓慧 杜松怀 +2 位作者 苏娟 关海鸥 邵利敏 《农业工程学报》 EI CAS CSCD 北大核心 2014年第23期238-245,共8页
针对如何从低压电网总泄漏电流中检测出生物体触电电流信号的难题,提出了一种基于网格搜索和交叉验证的最小二乘支持向量机的触电电流信号检测方法。首先在剩余电流动作保护装置触电物理试验系统平台上通过故障录波器获得生物体在3个典... 针对如何从低压电网总泄漏电流中检测出生物体触电电流信号的难题,提出了一种基于网格搜索和交叉验证的最小二乘支持向量机的触电电流信号检测方法。首先在剩余电流动作保护装置触电物理试验系统平台上通过故障录波器获得生物体在3个典型时刻(电源电压最大时刻、电源电压过零时刻及电源电压任意时刻)发生触电过程的总泄漏电流和触电电流波形,并截取触电前1个周期和触电后3个周期共800个采样点的信号数据作为触电试验样本数据;然后将触电试验样本数据进行滤波预处理,预处理后的多个样本采样点的总泄漏电流组合成特征向量输入最小二乘支持向量机(least square-support vector machine,LS-SVM),相应样本采样点的触电电流作为其输出,并通过网格搜索与交叉验证相结合的方法来优化最小二乘支持向量机参数,利用输出最优参数组合对触电电流与总泄漏电流的关系进行训练,从而建立了触电电流的检测模型;最后利用该方法对10组测试样本数据进行了检测,检测结果为:当训练样本数据为20组时,检测均方误差为14.0040,当训练样本数据为40组时,检测均方误差为11.7469,当训练试验数据为65组时,检测均方误差为11.1849。与径向基(radial basis function,RBF)神经网络方法相比,最小二乘支持向量机方法比径向基神经网络方法检测均方误差分别低3.7272、1.9132、0.1556,从而可较准确地从总泄漏电流中检测出生物体触电电流信号,为开发新一代基于生物体触电电流分量而动作的自适应型剩余电流保护装置提供理论依据。 展开更多
关键词 优化 电流 信号检测 总泄漏电流 触电电流 最小二乘支持向量机 网格搜索 交叉验证
在线阅读 下载PDF
长波光导HgCdTe红外探测器的可靠性 被引量:8
18
作者 刘大福 吴礼刚 +1 位作者 徐国森 龚海梅 《红外与激光工程》 EI CSCD 北大核心 2006年第3期289-293,共5页
从真空热浸和电流冲击两个方面对碲镉汞红外探测器进行了研究。真空热浸在星载红外探测器中是十分重要的一项试验,通过研究得到大面积甚长波探测器芯片的耐真空热浸温度为85℃、95℃下39 h的热浸会降低探测器的性能;在电流冲击的实验中... 从真空热浸和电流冲击两个方面对碲镉汞红外探测器进行了研究。真空热浸在星载红外探测器中是十分重要的一项试验,通过研究得到大面积甚长波探测器芯片的耐真空热浸温度为85℃、95℃下39 h的热浸会降低探测器的性能;在电流冲击的实验中,得出低温下探测器芯片耐冲击能力低于室温下的探测器芯片,低温下40mA的脉冲电流会降低其性能,而室温下相应的脉冲电流为70mA。粘接胶的热导率和厚度是影响耐冲击能力的主要因素。 展开更多
关键词 碲镉汞 红外探测器 可靠性 真空热浸 电流冲击
原文传递
农村低压电网触电电流数字特征描述与分析 被引量:12
19
作者 关海鸥 郭元建 +6 位作者 杜松怀 邵利敏 苏娟 余国太 朱建军 李锐腾 马琳琦 《中国农业大学学报》 CAS CSCD 北大核心 2014年第3期202-207,共6页
为开发新一代农村低压电网剩余电流保护与动作装置,针对生物触电故障的暂态过度过程中总泄漏电流频谱构成的复杂性和不确定性,利用高阶统计量分析检测信号的数字特征,提出了抽取总漏电电流变化过程表征指标的定量描述方法。仿真试验结... 为开发新一代农村低压电网剩余电流保护与动作装置,针对生物触电故障的暂态过度过程中总泄漏电流频谱构成的复杂性和不确定性,利用高阶统计量分析检测信号的数字特征,提出了抽取总漏电电流变化过程表征指标的定量描述方法。仿真试验结果分析表明:偏度中出现正偏离和负偏离的样本数占总样本数的比例为52.4%和47.6%,二者中有53.2%改变了触电前偏度值正负方向;触电故障发生时3个计算周期的峭度变化率增大的样本数占总样本数的比例分别为91.7%、7.4%和96.3%;计算信息熵2.25~3.26,相对无故障时,触电故障发生初期信息熵增大的样本数占总样本数在55.0%以上,触电后稳定期增大的样本数占总样本数73.4%以上。高阶统计量的数字特征变化显著,可以描述生物触电故障过程中总泄漏电流数字特征变化趋势与规律。 展开更多
关键词 农村低压电网 剩余电流保护 触电电流 高阶统计量
原文传递
一种触电信号的自动快速检测模型 被引量:31
20
作者 关海鸥 杜松怀 +5 位作者 苏娟 欧阳亚平 朱建军 梁英 李春兰 邵利敏 《电网技术》 EI CSCD 北大核心 2013年第8期2328-2335,共8页
针对未来低压电网剩余电流保护与动作技术中,如何检测触电时刻并识别总泄漏电流中人体触电支路电流信号的难题,利用数字信号的智能处理技术和具有自适应性与最佳逼近特性的组合神经网络有机结合,提出了一种触电电流信号的自动检测方法... 针对未来低压电网剩余电流保护与动作技术中,如何检测触电时刻并识别总泄漏电流中人体触电支路电流信号的难题,利用数字信号的智能处理技术和具有自适应性与最佳逼近特性的组合神经网络有机结合,提出了一种触电电流信号的自动检测方法。在对低压电网中原总泄漏电流信号进行小波消噪基础上,实现了触电时刻的自动检测,触电故障模式分类归属的决策;同时从总泄漏电流中提取触电电流幅值波形。仿真实验表明:该方法速度快且稳定,模式分类正确率达100%,提取幅值与实际值的平均相对误差为3.65%,计算时间为0.064 68 s,具有良好的适应性和实用性,对于开发新一代剩余电流保护装置具有重要的参考价值。 展开更多
关键词 触电电流 小波消噪 神经网络 故障检测 信号提取 模式分类
原文传递