-Based on a two-dimensional numerical M2 tidal model of the Huanghai and Bohai Seas, sediment transport of particles with different sizes in the computational area is given. It is concluded that tidal currents play an...-Based on a two-dimensional numerical M2 tidal model of the Huanghai and Bohai Seas, sediment transport of particles with different sizes in the computational area is given. It is concluded that tidal currents play an important role in sediment transport and deposition in the Huanghai and Bohai Seas.展开更多
Sulfide stress corrosion cracking (SSCC) behaviour of UNS G11180 steel in 5% NaCl solution with H2S was studied by slow strain rate tensile test (SSRT), SEM and electrochemical hydro gen permeation technique. The resu...Sulfide stress corrosion cracking (SSCC) behaviour of UNS G11180 steel in 5% NaCl solution with H2S was studied by slow strain rate tensile test (SSRT), SEM and electrochemical hydro gen permeation technique. The results reveal different cracking mechanism and H permeation current (IH) through UNS G11180 steel plate in different concentration of H2S solution. The susceptibility to SSCC of UNS G11180 Steel in 5% NaCl solution with H2S was evaluated by the permeation current(IH, μA), which depends on the concentration (c×10-6) of H2S by the equation:IH = 8.525 ×c0.7249. lt is proved that the electrochemical H permeation method is a practical way to assess the susceptibility to SSCC.展开更多
An equivalent relationship between electro magnetic flowmeters (EMFs) and the Hall effect is discussed in principle and three equivalent conclusions about their measuring equations are derived. Thereby,the calibratio...An equivalent relationship between electro magnetic flowmeters (EMFs) and the Hall effect is discussed in principle and three equivalent conclusions about their measuring equations are derived. Thereby,the calibration using the ionic current (CUIC) is introduced to the calibration of EMFs in a special Hall effect system. A basic system with these equations is specially given and discussed for realizing the method. Two key points about CUIC are proved by a simple experiment.展开更多
文摘-Based on a two-dimensional numerical M2 tidal model of the Huanghai and Bohai Seas, sediment transport of particles with different sizes in the computational area is given. It is concluded that tidal currents play an important role in sediment transport and deposition in the Huanghai and Bohai Seas.
文摘Sulfide stress corrosion cracking (SSCC) behaviour of UNS G11180 steel in 5% NaCl solution with H2S was studied by slow strain rate tensile test (SSRT), SEM and electrochemical hydro gen permeation technique. The results reveal different cracking mechanism and H permeation current (IH) through UNS G11180 steel plate in different concentration of H2S solution. The susceptibility to SSCC of UNS G11180 Steel in 5% NaCl solution with H2S was evaluated by the permeation current(IH, μA), which depends on the concentration (c×10-6) of H2S by the equation:IH = 8.525 ×c0.7249. lt is proved that the electrochemical H permeation method is a practical way to assess the susceptibility to SSCC.
文摘An equivalent relationship between electro magnetic flowmeters (EMFs) and the Hall effect is discussed in principle and three equivalent conclusions about their measuring equations are derived. Thereby,the calibration using the ionic current (CUIC) is introduced to the calibration of EMFs in a special Hall effect system. A basic system with these equations is specially given and discussed for realizing the method. Two key points about CUIC are proved by a simple experiment.