期刊文献+
共找到38篇文章
< 1 2 >
每页显示 20 50 100
Numerical simulation and experimental validation of a direct current air corona discharge under atmospheric pressure 被引量:15
1
作者 刘兴华 何为 +3 位作者 杨帆 王虹宇 廖瑞金 肖汉光 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第7期368-377,共10页
Air corona discharge is one of the critical problems associated with high-voltage equipment. Investigating the corona mechanism plays a key role in enhancing the electrical insulation performance. An improved self-con... Air corona discharge is one of the critical problems associated with high-voltage equipment. Investigating the corona mechanism plays a key role in enhancing the electrical insulation performance. An improved self-consistent multi-component two-dimensional plasma hybrid model is presented for the simulation of a direct current atmospheric pressure corona discharge in air. The model is based on plasma hydrodynamic and chemical models, and includes 12 species and 26 reactions. In addition, the photoionization effect is introduced into the model. The simulation on a bar-plate electrode configuration with an inter-electrode gap of 5.0 mm is carried out. The discharge voltage- current characteristics and the current density distribution predicted by the hybrid model agree with the experimental measurements. In addition, the dynamics of volume charged species generation, discharge current waveform, current density distribution at an electrode, charge density, electron temperature, and electric field variations are investigated in detail based on the model. The results indicate that the model can contribute valuable insights into the physics of an air plasma discharge. 展开更多
关键词 corona discharge hybrid model discharge voltage-current characteristics current den-sity distribution
原文传递
Numerical Simulation of Current Density Distribution in Keyhole Double-Sided Arc Welding 被引量:4
2
作者 JunshengSUN ChuansongWU +1 位作者 MinZHANG HouxiaoWANG 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2004年第2期228-231,共4页
In the double-sided arc welding system (DSAW) composing of PAW+TIG arcs, the PAW arc is guided by the TIG arc so that the current mostly flows through the direction of the workpiece thickness and the penetration is gr... In the double-sided arc welding system (DSAW) composing of PAW+TIG arcs, the PAW arc is guided by the TIG arc so that the current mostly flows through the direction of the workpiece thickness and the penetration is greatly improved. To analyze the current density distribution in DSAW is beneficial to understanding of this process. Considering all kinds of dynamic factors acting on the weldpool, this paper discusses firstly the surface deformation of the weldpool and the keyhole formation in PAW+TIG DSAW process on the basis of the magnetohydrodynamic theory and variation principles. Hence, a model of the current density distribution is developed. Through numerical simulation, the current density distribution in PAW+TIG DSAW process is quantitatively analyzed. It shows that the minimal radius of keyhole formed in PAW+TIG DSAW process is 0.5 mm and 89.5 percent of current flows through the keyhole. 展开更多
关键词 PAW+TIG double-sided arc welding Surface deformation of the weldpool KEYHOLE current density distribution
在线阅读 下载PDF
Plating current density distribution of lithium metal anodes in pouch cells 被引量:2
3
作者 Shi-Jie Yang Xin Shen +5 位作者 Xin-Bing Cheng Feng-Ni Jiang Rui Zhang He Liu Lei Liu Hong Yuan 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2022年第6期70-75,I0003,共7页
The uniformity of current density distribution upon electrodes is one of the most important factors determining the lithium dendrites growth and cycling performance of lithium metal batteries(LMBs). Herein,current den... The uniformity of current density distribution upon electrodes is one of the most important factors determining the lithium dendrites growth and cycling performance of lithium metal batteries(LMBs). Herein,current density distributions of lithium metal anodes induced by various engineering factors, consisting of uneven cathode, electrolyte distribution, and different tab positions, and their effects on the electrochemical performance are investigated theoretically and experimentally in pouch cells. The deviation of current density in lithium metal anodes ranges from 2.47% to 196.18% due to the different levels of uneven cathode materials. However, the deviation is just 13.60% for different electrolyte thicknesses between cathodes and anodes, even a ten-layer separator in some positions. The maximum deviation for variational tab positions is only 0.17%. The nonuniformity in current density distribution results in severe dendrite growth issues and poor electrochemical performance of LMBs. This work not only confirms the direct correlation between the uneven current density distribution and lithium deposition behaviors, but also points out the decisive effects of cathode surface roughness on current distribution of anodes, to which more attentions should be paid in practical applications of LMBs. 展开更多
关键词 Pouch cell Lithium metal anode DENDRITE current density distribution Safety
在线阅读 下载PDF
Value of Topology Approach to Diagnose of CAD Based on Magnetocardiographic Current Distribution Maps in Difficult-to-Diagnose Patients 被引量:3
4
作者 I. Chaikovsky L. Stadnyuk +5 位作者 A. Verba Yu. Vasetskyi M. Budnyk G. Mjasnikov A. Kazmirchuk A. Lomakovskyi 《World Journal of Cardiovascular Diseases》 2016年第7期235-245,共12页
Objective: The purpose of this work is to examine the usefulness of the topological approach for analysis of current density maps during ST-T interval in detection of coronary artery disease (CAD) in patients with pro... Objective: The purpose of this work is to examine the usefulness of the topological approach for analysis of current density maps during ST-T interval in detection of coronary artery disease (CAD) in patients with proved CAD but normal results of routine tests. Materials and Methods: The patient group included 123 patients. Coronary angiography was done due to chest pain. The control group consisted of 124 healthy volunteers. The MCG test was done by 4-channels MCG system installed at unshielded setting. An integral topological index Kideal, consisting of 4 parameters, has been counted. Results and Conclusions: It is shown that Kideal was higher in patient group compared to control one. Sensitivity was 87%, and specificity was 64%. The topological analysis of MCG current density maps is a valuable tool in noninvasive detection of CAD in difficult-to-diagnose patients with uninformative results of routine tests. 展开更多
关键词 MAGNETOCARDIOGRAPHY Coronary Artery Disease current Distribution Difficult-to-Diagnose Patients Topology Parameters
在线阅读 下载PDF
Analytical solutions for transverse distributions of stream-wise velocity in turbulent flow in rectangular channel with partial vegetation 被引量:1
5
作者 槐文信 耿川 +1 位作者 曾玉红 杨中华 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2011年第4期459-468,共10页
The theory of poroelasticity is introduced to study the hydraulic properties of the steady uniform turbulent flow in a partially vegetated rectangular channel. Plants are assumed as immovable media. The resistance cau... The theory of poroelasticity is introduced to study the hydraulic properties of the steady uniform turbulent flow in a partially vegetated rectangular channel. Plants are assumed as immovable media. The resistance caused by vegetation is expressed by the theory of poroelasticity. Considering the influence of a secondary flow, the momentum equation can be simplified. The momentum equation is nondimensionalized to obtain a smooth solution for the lateral distribution of the longitudinal velocity. To verify the model, an acoustic Doppler velocimeter (ADV) is used to measure the velocity field in a rectangular open channel partially with emergent artificial rigid vegetation. Comparisons between the measured data and the computed results show that the method can predict the transverse distributions of stream-wise velocities in turbulent flows in a rectangular channel with partial vegetation. 展开更多
关键词 theory of poroelasticity open channel flow VEGETATION secondary current depth-averaged velocity distribution
在线阅读 下载PDF
Spatial Distribution Characteristics of Surface Tidal Currents in the Southwest of Taiwan Strait 被引量:1
6
作者 SHEN Zhiben WU Xiongbin +3 位作者 LIN Hang CHEN Xiaofeng XU Xing’an LI Lun 《Journal of Ocean University of China》 SCIE CAS 2014年第6期971-978,共8页
This study was conducted on the spatial distribution characteristics of surface tidal currents in the southwestern Taiwan Strait based on the quasi-harmonic analysis of current data obtained by two high frequency surf... This study was conducted on the spatial distribution characteristics of surface tidal currents in the southwestern Taiwan Strait based on the quasi-harmonic analysis of current data obtained by two high frequency surface wave radar(HFSWR) systems. The analysis shows that the tidal current pattern in the southwestern Taiwan Strait is primarily semi-diurnal and influenced significantly by shallow water constituents. The spatial distribution of tidal current ellipses of M2 is probably affected by the interaction between two different systems of tide wave, one from the northern mouth of Taiwan Strait and the other from the Bashi Channel. The directions of the major axes of M2 tidal current ellipses coincide roughly with the axis of the Taiwan Strait. The spatial distribution of the magnitudes of the probable maximum current velocity(PMCS) shows gradual increase of the velocity from northeast to southwest, which is in accordance with the spatial distribution of the measured maximum current velocity(MMCS). The directions of the residual currents are in accordance with the direction of the prevailing monsoon wind at the Taiwan Strait and the direction of the Taiwan warm current during summer. The bathymetry also shows a significant effect on the spatial distribution characteristics of tidal currents. 展开更多
关键词 high frequency surface wave radar quasi-harmonic analysis spatial distribution characteristic surface tidal current Taiwan Strait
在线阅读 下载PDF
Single-phase earth fault current distribution between optical fiber composite overhead ground wire and ordinary ground wire in transmission system
7
作者 许高雄 《Journal of Chongqing University》 CAS 2011年第2期78-83,共6页
It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of sing... It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles. 展开更多
关键词 loop method single-phase earth fault short-circuit current distribution optical fiber composite overhead ground wire ordinary ground wire
在线阅读 下载PDF
Input Admittance and Current Distribution of Infinitely Long Circular Cylindrical Antenna Driven at Center
8
作者 Jinxion Chen & Guotai YinBeijing Institute of Radio Measurement, P.O.Box 3923, Beijing 100854, China 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 1991年第2期73-81,共9页
In this paper, by change of integration path in complex spectrum domain and by defining input admittance as the ratio of complex radiated power to amplitude of square of voltage across the gap, new expressions of admi... In this paper, by change of integration path in complex spectrum domain and by defining input admittance as the ratio of complex radiated power to amplitude of square of voltage across the gap, new expressions of admittance (valid for all frequencies ) of infinitely long cylindrical antenna with and without conducting ground are obtained. Meanwhile corresponding formulas of current distribution are derived in detail. Some numerical computations are also given. 展开更多
关键词 Input admittance current distribution Long cylindrical antenna.
在线阅读 下载PDF
Dependence of Switching Current Distribution of a Current-Biased Josephson Junction on Microwave Frequency
9
作者 翟计全 李永超 +5 位作者 史建新 周渝 李小虎 许伟伟 孙国柱 吴培亨 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第4期118-121,共4页
We investigate the distribution of the switching current of a current-biased Josephson junction (CBJJ) and its dependence on the microwave frequency using two theoretical methods, one of which is the quantum traject... We investigate the distribution of the switching current of a current-biased Josephson junction (CBJJ) and its dependence on the microwave frequency using two theoretical methods, one of which is the quantum trajectory method and the other is the master equation method. Both the methods show that the distribution of the switching current of CBJJ will exhibit double peaks in a certain range of microwave frequency if proper microwave power is given, and the gap between the two peaks will increase with the microwave frequency. The obtained results can be used to identify the energy difference of the ground and first excited states in a Josephson junction for any bias current. 展开更多
关键词 Dependence of Switching current Distribution of a current-Biased Josephson Junction on Microwave Frequency
原文传递
Optimized Design in Current,Temperature and Stress Distributions for Paralleled Chips in Press-pack IGBT Modules
10
作者 Lubin Han Lin Liang Yong Kang 《CSEE Journal of Power and Energy Systems》 2025年第5期2325-2338,共14页
In a press-pack insulated gate bipolar transistor(IGBT),a compact packaging structure forms a strong electromagnetic coupling,thermal coupling,and stress coupling,threatening current sharing,temperature sharing,and st... In a press-pack insulated gate bipolar transistor(IGBT),a compact packaging structure forms a strong electromagnetic coupling,thermal coupling,and stress coupling,threatening current sharing,temperature sharing,and stress sharing of paralleled chips.Optimized layouts are proposed based on the inductance analytical model to improve the performance and reliability of Press-Pack IGBT devices.What’s more,transient and steady-state co-simulation using an improved behavioral model is performed to verify the proposed layout.In the test,the PCB Rogowski coil,direct thermocouple,and force-sensitive parameters fittings are used to measure the current distribution,temperature distribution,and stress distribution.The simulation and test results indicate that a rotationally symmetrical layout with IGBT surrounding the FRD mode can achieve uniform current,temperature,and stress. 展开更多
关键词 current distribution layout optimization press-Pack IGBT stress distribution temperature distribution
原文传递
A study of pulsed high voltage driven hollow-cathode electron beam sources through synchronous optical trigger
11
作者 霍卫杰 贺伟国 +2 位作者 韩罗峰 朱康武 王锋 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第5期82-90,共9页
In this study,a pulsed,high voltage driven hollow-cathode electron beam sources through an optical trigger is designed with characteristics of simple structure,low cost,and easy triggering.To validate the new design,t... In this study,a pulsed,high voltage driven hollow-cathode electron beam sources through an optical trigger is designed with characteristics of simple structure,low cost,and easy triggering.To validate the new design,the characteristics of hollow-cathode discharge and electron beam characterization under pulsed high voltage drive are studied experimentally and discussed by discharge characteristics and analyses of waveform details,respectively.The validation experiments indicate that the pulsed high voltage supply significantly improves the frequency and stability of the discharge,which provides a new solution for the realization of a high-frequency,high-energy electron beam source.The peak current amplitude in the high-energy electron beam increases from 6.2 A to 79.6 A,which indicates the pulsed power mode significantly improves the electron beam performance.Besides,increasing the capacitance significantly affects the highcurrent,lower-energy electron beam more than the high-energy electron beam. 展开更多
关键词 hollow-cathode nanosecond pulsed electron beam sources optical trigger pulsed high voltage supply beam current distribution
在线阅读 下载PDF
Optimization Analysis of Sliding Electrical Contact Interface Based on Electromechanical Coupling
12
作者 Pengfei Yue Jiahe Ma +1 位作者 Ronghao Shi Kexing Song 《Journal of Applied Mathematics and Physics》 2024年第11期4030-4041,共12页
This work addresses the critical issue of current density distribution in the sliding electrical contact interface based on electromechanical coupling, which is essential for minimizing damage and enhancing performanc... This work addresses the critical issue of current density distribution in the sliding electrical contact interface based on electromechanical coupling, which is essential for minimizing damage and enhancing performance. Using electromechanical coupling analysis and finite element analysis (FEA), the effects of initial contact pressure, pulse current input, and armature speed on current density are examined. Key findings indicate that optimizing the convex rail and armature structures significantly reduces peak current density, improving uniformity and reducing damage. These optimizations enhance the efficiency, accuracy, and service life of sliding electrical contact interfaces, providing a theoretical foundation for designing more durable and efficient high-current-density applications. 展开更多
关键词 Sliding Contact Interface Electromagnetic Propulsion current Density Distribution Finite Element Analysis
在线阅读 下载PDF
Study of current distribution generation in PEMFC based on conditional variational auto-encoder
13
作者 Chengyin Shi Cong Yin +2 位作者 Weilong Luo Hailong Liu Hao Tang 《Energy and AI》 2025年第3期578-591,共14页
The Proton Exchange Membrane Fuel Cell(PEMFC)converts the chemical energy of hydrogen fuel directly into electrical energy with broad application prospects.Understanding how current density is distributed in the PEMFC... The Proton Exchange Membrane Fuel Cell(PEMFC)converts the chemical energy of hydrogen fuel directly into electrical energy with broad application prospects.Understanding how current density is distributed in the PEMFC systems is crucial as it is a key factor influencing system performance.However,direct modeling for current distribution may encounter the challenge of dimensional catastrophe owing to the high dimensionality of the data.This paper uses a high-resolution segmented measurement device with 396 points to conduct experimental tests on the current distribution of a PEMFC with reactive area of 406 cm^(2) during a stepwise increase in load current.The current distribution is modeled based on the test results to learn the mapping relationship between the experimental parameters and the current distribution.The proposed model utilizes a Conditional Variational Auto-Encoder(CVAE)to generate current distributions.The MSE(Mean-Square Error)of the trained CVAE model reaches 9.2×10^(-5),and the comparison results show that the 222.9A current distribution error has the largest MSE of 6.36×10^(-4) and a KL Divergence(Kullback-Leibler Divergence)of 9.55×10^(-4),both of which are at a low level.This model enables the direct determination of the current distribution based on the experimental parameters,thereby establishing a technical foundation for investigating the impact of experimental conditions on fuel cells.This model is also of great significance for research on fuel cell system control strategies and fault diagnosis. 展开更多
关键词 Proton exchange membrane fuel cell Segmented measurement device current distribution Conditional variational auto-encoder
在线阅读 下载PDF
Effects of mask wall angle on matrix-hole shape changes during electrochemical machining by mask 被引量:8
14
作者 李冬林 朱荻 +1 位作者 李寒松 刘金国 《Journal of Central South University》 SCIE EI CAS 2011年第4期1115-1120,共6页
The influences of the mask wall angle on the current density distribution,shape of the evolving cavity and machining accuracy were investigated in electrochemical machining(ECM) by mask.A mathematical model was develo... The influences of the mask wall angle on the current density distribution,shape of the evolving cavity and machining accuracy were investigated in electrochemical machining(ECM) by mask.A mathematical model was developed to predict the shape evolution during the ECM by mask.The current density distribution is sensitive to mask wall angle.The evolution of cavity is determined by the current density distribution of evolving workpiece surface.The maximum depth is away from the center of holes machined,which leads to the island appearing at the center of cavity for mask wall angles greater than or equal to 90°(β≥90°).The experimental system was established and the simulation results were experimentally verified.The results indicate that the simulation results of cavity shape are consistent with the actual ones.The experiments also show that the repetition accuracy of matrix-hole for β≥90° is higher than that for β<90°.A hole taper is diminished,and the machining accuracy is improved with the mask wall angle increasing. 展开更多
关键词 electrochemical machining matrix-hole machining accuracy current density distribution
在线阅读 下载PDF
Boundary Element Method (BEM) Analysis for Galvanic Corrosion of Hot Dip Galvanized Steel Immersed in Seawater 被引量:3
15
作者 Xiao Tang Yuzhi Zhang +1 位作者 Meng Liu Yan Li 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2009年第2期194-198,共5页
A numerical analysis of galvanic corrosion of hot-dip galvanized steel immersed in seawater was presented. The analysis was based on the boundary element methods (BEMs) coupled with Newton-Raphson iterative techniqu... A numerical analysis of galvanic corrosion of hot-dip galvanized steel immersed in seawater was presented. The analysis was based on the boundary element methods (BEMs) coupled with Newton-Raphson iterative technique to treat the nonlinear boundary conditions, which were determined by the experimental polarization curves. Results showed that galvanic current density concentrates on the boundary of steel substrate and zinc coating, and the sacrificial protection of zinc coating to steel substrate results in overprotection of steel cathode. Not only oxygen reduction but also hydrogen reduction could occur as cathode reactions, which probably led up to the adsorption and absorption of hydrogen atoms. Flat galvanized steel tensile sample shows a brittle behavior similar to hydrogen embrittlement according to the SSRT (show strain rate test) in seawater. 展开更多
关键词 Galvanic corrosion BEM Hydrogen absorption Potential distribution current density distribution
在线阅读 下载PDF
Non-Intrusive Magneto-Optic Detecting System for Investigations of Air Switching Arcs 被引量:2
16
作者 张鹏飞 张国钢 +2 位作者 董金龙 刘婉莹 耿英三 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第7期661-668,共8页
In current investigations of electric arc plasmas, experiments based on modern testing technology play an important role. To enrich the testing methods and contribute to the understanding and grasping of the inherent ... In current investigations of electric arc plasmas, experiments based on modern testing technology play an important role. To enrich the testing methods and contribute to the understanding and grasping of the inherent mechanism of air switching arcs, in this paper, a nonintrusive detecting system is described that combines the magneto-optic imaging(MOI) technique with the solution to inverse electromagnetic problems. The detecting system works in a sequence of main steps as follows: MOI of the variation of the arc flux density over a plane, magnetic field information extracted from the magneto-optic(MO) images, arc current density distribution and spatial pattern reconstruction by inverting the resulting field data. Correspondingly, in the system, an MOI set-up is designed based on the Faraday effect and the polarization properties of light, and an intelligent inversion algorithm is proposed that involves simulated annealing(SA).Experiments were carried out for high current(2 kA RMS) discharge cases in a typical low-voltage switchgear. The results show that the MO detection system possesses the advantages of visualization, high resolution and response, and electrical insulation, which provides a novel diagnostics tool for further studies of the arc. 展开更多
关键词 arc current density distribution arc pattern inverse electromagnetic problem low-voltage switchgear magneto-optic imaging technique
在线阅读 下载PDF
全绝缘自支撑电缆系统设计(英文) 被引量:1
17
作者 George G.Karady Kumaraguru Prabakar 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2715-2720,共6页
All-dielectric self-supporting(ADSS) cables are installed along with transmission line for the purpose of communication.During installation the outer layer of the cable is hydrophobic and is not prone to dry band arci... All-dielectric self-supporting(ADSS) cables are installed along with transmission line for the purpose of communication.During installation the outer layer of the cable is hydrophobic and is not prone to dry band arcing. These cables become less hydrophobic over time and become vulnerable to dry band arcing.This loss in hydrophobicity is because of the contamination formed on the outer layer due to pollution.This is one of the reasons which cause cable failure.Considerable amount of losses will be incurred on the occurrence of a cable failure as the cables are also leased to other companies.An improved equivalent circuit is used to calculate the voltage and current distribution of the double circuit line.A three-phase single circuit line and a three-phase double circuit line are used to calculate their corresponding voltage distribution and current distribution.The results could be used to predict dry band arcing on similar models.The method used considers sag,span and pollution on ADSS cable. 展开更多
关键词 dry band arcing all-dielectric self-supporting cable fiber optic cable voltage distribution current distribution all-dielectric self-supporting circuit simulation
原文传递
Electrical characteristics of new three-phase traction power supply system for rail transit 被引量:1
18
作者 Xiaohong Huang Hanlin Wang +4 位作者 Qunzhan Li Naiqi Yang Tao Ren You Peng Haoyang Li 《Railway Engineering Science》 2023年第1期75-88,共14页
A novel three-phase traction power supply system is proposed to eliminate the adverse effects caused by electric phase separation in catenary and accomplish a unifying manner of traction power supply for rail transit.... A novel three-phase traction power supply system is proposed to eliminate the adverse effects caused by electric phase separation in catenary and accomplish a unifying manner of traction power supply for rail transit.With the application of two-stage three-phase continuous power supply structure,the electrical characteristics exhibit new features differing from the existing traction system.In this work,the principle for voltage levels determining two-stage network is dissected in accordance with the requirements of traction network and electric locomotive.The equivalent model of three-phase traction system is built for deducing the formula of current distribution and voltage losses.Based on the chain network model of the traction network,a simulation model is established to analyze the electrical characteristics such as traction current distribution,voltage losses,system equivalent impedance,voltage distribution,voltage unbalance and regenerative energy utilization.In a few words,quite a lot traction current of about 99%is undertaken by long-section cable network.The proportion of system voltage losses is small attributed to the two-stage three-phase power supply structure,and the voltage unbal-ance caused by impedance asymmetry of traction network is less than 1‰.In addition,the utilization rate of regenerative energy for locomotive achieves a significant promotion of over 97%. 展开更多
关键词 Three-phase AC power supply Two-stage power supply structure Electrical characteristics current distribution Voltage losses Regenerative energy
在线阅读 下载PDF
Novel experimental strategy towards temperature inhomogeneity during spark plasma sintering of metallic glasses 被引量:2
19
作者 Huaping Ding Xiaoqian Bao +6 位作者 Mao Zhang Junsong Jin Lei Deng Kefu Yao Atefeh Solouk Pan Gong Xinyun Wang 《Advanced Powder Materials》 2023年第3期1-10,共10页
Despite the importance of temperature distribution in spark plasma sintering of metallic glasses,its quantification has been experimentally laborious.This work proposes an experimental strategy to determine the sinteri... Despite the importance of temperature distribution in spark plasma sintering of metallic glasses,its quantification has been experimentally laborious.This work proposes an experimental strategy to determine the sintering temperature by establishing a quantitative relationship between the temperature-thermal signal.We reproduced the thermal profiles of spark plasma sintering by isothermal annealing and found a correlation between annealing temperature and isothermal crystallization time.This strong correlation indicates the temperature-dependent structural evolution of glassy powders.Using isothermal crystallization time as the measuring gauge,we correlated the annealing temperature to the sintering temperature and obtained the sample temperature map.The sample temperature is at least 19C higher than the nominal temperature of 425C measured by the thermocouple.Meanwhile,the sample temperature shows a hump-shaped pattern closely correlated with the current density.The maximum temperature of 453C occurs on the sample/punches contact surfaces.Temperature heterogeneity within the sample induces diverse microstructures and porous structures.We elucidate that the temperature inhomogeneity is intrinsic,given the presence of contact interfaces.Contact resistances affect the current distribution and heat transfer,resulting in a larger temperature gradient than the traditional powder metallurgy process. 展开更多
关键词 Metallic glass Spark plasma sintering Temperature inhomogeneity Isothermal crystallization time current distribution
在线阅读 下载PDF
Evaluation of 1-kW Class PEM Fuel Cell Stack under In-Situ Conditions Considering Individual Cells 被引量:1
20
作者 Keiichi Okajima Takumi Nasu Seunghyuk Choi 《Journal of Energy and Power Engineering》 2014年第9期1543-1551,共9页
Focusing on the stack performance is important for practical use of PEM (proton exchange membrane) fuel cells. This paper describes the experiments and evaluation on the performance of 1-kW class PEM FC (fuel cell... Focusing on the stack performance is important for practical use of PEM (proton exchange membrane) fuel cells. This paper describes the experiments and evaluation on the performance of 1-kW class PEM FC (fuel cell) stacks for reliability improvement. We investigated the stack performance, voltage distributions, and internal resistance of the single cells of a PEMFC stack. The standard deviation of individual cell voltages increased almost linearly with the current load by 2.5 times that in the case of an open-circuit voltage, with a standard deviation of 33 A. From the results of the current-interrupt tests, the internal resistance of the FC stack was calculated to be 43.53 mΩ. The internal resistances of each individual cell were not uniform. The average internal resistance was 0.505 mΩ at 18 A, which was less than that calculated from the stack current-interrupt test. We also investigated the current distribution in the PEM FC stack under in-situ conditions using a triaxial magnetic sensor probe. From the results, the current distribution tended to concentrate on the underside of the cell. Each I-V curve at the divided plane can be obtained using the developed method. 展开更多
关键词 Proton exchange membrane fuel cell PEM STACK current distribution magnetic field magnetic sensor probe diagnostics.
在线阅读 下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部