A two-dimensional, three-temperature radiation magneto-hydrodynamics model is applied to the investigation of evolutional trends in x-ray radiation power, energy, peak plasma temperature and density as functions of dr...A two-dimensional, three-temperature radiation magneto-hydrodynamics model is applied to the investigation of evolutional trends in x-ray radiation power, energy, peak plasma temperature and density as functions of drive current rise-time and initial load density distribution by using the typical experimental parameters of tungsten wire-array Z- pinch on the Qiangguang-I generator. The numerical results show that as the drive current rise-time is shortened, x-ray radiation peak power, energy, peak plasma density and peak ion temperature increase approximately linearly, but among them the x-ray radiation peak power increases more quickly. As the initial plasma density distribution in the radial direction becomes gradually flattened, the peak radiation power and the peak ion-temperature almost exponentially increase, while the radiation energy and the peak plasma density change only a little. The main effect of shortening drive current rise-time is to enhance compression of plasma, and the effect of flattening initial load density distribution in the radial direction is to raise the plasma temperature. Both of the approaches elevate the x-ray peak radiation power展开更多
Conductive substrates with low cost,lightweight,and chemical stability have been highly recognized as alternative current collectors for energy storage devices.Graphite foil is promising to fulfill these requests,wher...Conductive substrates with low cost,lightweight,and chemical stability have been highly recognized as alternative current collectors for energy storage devices.Graphite foil is promising to fulfill these requests,whereas the inert surface chemistry denies its possibility as the carrier with high-mass loading active species.Herein,we report a facile yet efficient laser-mediated strategy to fast regulate graphite foils for robustly loading active species.The smooth and hydrophobic graphite foil surface turned to be a rough,super-hydrophilic one containing oxygen-rich clusters after lasering.The reconstructed surface affords anchors for active species,such as nanostruetured MnO_(2),FeOOH,and Fe_(2)O_(3),with the highest loading mass of 20 mg·cm^(-2).The high-mass loading MnO_(2)electrode offers an areal capacitance of 3933 mF·cm^(-2)at 1 mA·cm^(-2).Then,the asymmetric supercapacitor,fabricated by MnO_(2)and Fe_(2)O_(3)deposited laser-irradiated graphite foils,exhibits improved performance with high energy density,large power capability,and long-term stability.The strategy suggests a reliable way to produce alternative current collectors for robust energy storage devices.展开更多
The attenuation of the acoustic activity in marble specimens under uniaxial compressive loadingunloading loops is quantified in juxtaposition to that of the electric activity.In parallel,the existence of"pre-fail...The attenuation of the acoustic activity in marble specimens under uniaxial compressive loadingunloading loops is quantified in juxtaposition to that of the electric activity.In parallel,the existence of"pre-failure indiceso"warning about entrance into a critical stage,that of impending fracture,is explored.The acoustic activity is quantified in terms of the normalized number of acoustic hits,their average rate of production and their cumulative energy,and,the cumulative counts and their average rate of change.The electric activity is studied in terms of the pressure stimulated currents and the electric charge released.The analysis revealed that the acoustic and electric activities are linearly correlated to each other,suggesting that they are different manifestations of the same damage mechanisms.In addition,Kaiser's effect,governing the acoustic activity,is found to govern,also,the electric activity.Moreover,it is concluded that entrance into the critical stage is safely predicted by means of a simple criterion,based on the evolution of the average rate of change of the normalized cumulative counts in the natural time domain.These predictions are almost identical with those of the criterion based on the "varianceo" and the "entropies" of the time series of acoustic events in this domain.展开更多
In this paper, the boundary value problem (BVP) of 3 D transient eddy current field in the end region in the case that the generator is affected by impact load is specified. Besides, ways to implement discrete method...In this paper, the boundary value problem (BVP) of 3 D transient eddy current field in the end region in the case that the generator is affected by impact load is specified. Besides, ways to implement discrete methods in both time domain and space domain during the solution of the problem are investigated. The Crank Nicolson scheme is utilized to attain the iterative format of time differential, after taking factors that can ensure both computation precision and stability into consideration. In this paper, the magnetic distribution in the end region of a turbogenerator in the case that the generator is affected by impact load is specified. As a result, it provides foundation for further study of electromagnetic force and electromagnetic vibration in the end region of the turbogenerator.展开更多
The discrete iterative map model of peak current-mode controlled buck converter with constant current load(CCL),containing the output voltage feedback and ramp compensation, is established in this paper. Based on th...The discrete iterative map model of peak current-mode controlled buck converter with constant current load(CCL),containing the output voltage feedback and ramp compensation, is established in this paper. Based on this model the complex dynamics of this converter is investigated by analyzing bifurcation diagrams and the Lyapunov exponent spectrum. The effects of ramp compensation and output voltage feedback on the stability of the converter are investigated. Experimental results verify the simulation and theoretical analysis. The stability boundary and chaos boundary are obtained under the theoretical conditions of period-doubling bifurcation and border collision. It is found that there are four operation regions in the peak current-mode controlled buck converter with CCL due to period-doubling bifurcation and border-collision bifurcation. Research results indicate that ramp compensation can extend the stable operation range and transfer the operating mode, and output voltage feedback can eventually eliminate the coexisting fast-slow scale instability.展开更多
The study of pressure stimulated current(PSC)changes of rocks is significant to monitor dynamic disasters in mines and rock masses.The existing studies focus on change laws and mechanism of currents generated under th...The study of pressure stimulated current(PSC)changes of rocks is significant to monitor dynamic disasters in mines and rock masses.The existing studies focus on change laws and mechanism of currents generated under the loading of rocks.An electrical and mechanics test system was established in this paper to explore the impacts of loading rates on PSCs.The results indicated that PSC curves of different rocks had different change laws under low/high loading rates.When the loading rate was relatively low,PSC curves firstly changed gently and then increased exponentially.Under high loading rates,PSC curves experienced the rapid increase stage,gentle increase stage and sudden change stage.The compressive strength could greatly affect the peak PSC in case of rock failure.The loading rate was a key factor in average PSC.Under low loading rates,the variations of PSCs conformed to the damage charge model of fracture mechanics,while they did not at the fracture moment.Under high loading rates,the PSCs at low stress didn’t fit the model due to the stress impact effects.The experimental results could provide theoretical basis for the influence of loading rates on PSCs.展开更多
Wave-induced liquefaction of the seabed is a geohazard frequently encountered in shallow waters.Although widely discussed,most studies paid attention to the seabed response under a single sequence of wave loading.Howe...Wave-induced liquefaction of the seabed is a geohazard frequently encountered in shallow waters.Although widely discussed,most studies paid attention to the seabed response under a single sequence of wave loading.However,the seabed suffers from repeated‘wave loading–dissipation’phases in a real ocean environment.In this study,a homogeneous sandy seabed model is established to investigate the mechanism of wave-induced liquefaction by considering the existence of currents.Finite element analyses are conducted by incorporating a kinematic hardening elastoplastic model into the commercial package Abaqus.The constitutive model is validated against centrifugal wave tests.Parametric studies are conducted to demonstrate the effects of relative densities,current,and wave-loading history on the seabed response.The predicted excess pore pressure,effective stress paths,and associated variation of relative density are discussed in detail.The results show that the densification of soils significantly enhances the resistance against liquefaction,which provides new insight into the mechanism of residual liquefaction during wave sequences.展开更多
Submerged floating tunnel(SFTs)are typically subjected to complex external environmental and internal loads such as wave currents and traffic load.In this study,this problem is investigated through a finite element me...Submerged floating tunnel(SFTs)are typically subjected to complex external environmental and internal loads such as wave currents and traffic load.In this study,this problem is investigated through a finite element method able to account for fluid-structure interaction.The obtained results show that increasing the number of vehicles per unit length enhances the transverse vibrational displacements of the SFT cross sections.Under ultimate traffic load condition,one-way and two-way syntropic distributions can promote the dynamic responses of SFTs whereas two-way reverse distributions have the opposite effect.展开更多
The photovoltaic (PV) generator exhibits a nonlinear current-voltage (I-V) characteristic that its maximum power point (MPP) varies with solar insolation. In this paper, a maximum power point tracking (MPPT) method us...The photovoltaic (PV) generator exhibits a nonlinear current-voltage (I-V) characteristic that its maximum power point (MPP) varies with solar insolation. In this paper, a maximum power point tracking (MPPT) method using fuzzy logic control (FLC) is presented. This method is based on the concept of perturbation and observation (P & O) algorithm to track the MPP of a stand-alone PV system. The controller is used to maximize the power generated by the PV array and the simulation of the system is implemented in MATLAB. Simulation results are compared with those obtained by the conventional P & O controller. Results show that the FLC gives better and more reliable control for the stand-alone PV system feeding hybrid loads.展开更多
Using an irregularly oscillating tray and flume, a series of experiments are completed to evaluate bed-load sediment transport rate under irregular wave -current coexistent field. Testing conditions include three i...Using an irregularly oscillating tray and flume, a series of experiments are completed to evaluate bed-load sediment transport rate under irregular wave -current coexistent field. Testing conditions include three interaction angles 0', 45', 90' and two kinds of median sizes (0.38 and 1.10 mm). The results of transport rate show that the net sediment transport rate can be expressed approximately as the function of the maximum bottom shear stress of waves, mean shear stress of current and the grain size.展开更多
A dynamic response analysis in the frequency domain is presented for risers subjected to combined wave and current loading. Considering the effects of current, a modified wave spectrum is adopted to compute the linear...A dynamic response analysis in the frequency domain is presented for risers subjected to combined wave and current loading. Considering the effects of current, a modified wave spectrum is adopted to compute the linearized drag force. An additional drag force convolution term is added to the linearized drag force spectrum, therefore the error is reduced which arises from the truncation of higher order terms in the drag force auto-correlation function. An expression of linearized drag force spectrum is given taking the relative velocity into account. It is found that the additional term is a fold convolution integral. In this paper dynamic responses of risers are investigated, while the influence of floater motion on risers is considered. The results demonstrate that the accuracy of the present method reaches the degree required in time domain analysis.展开更多
The tensile strength of CVD SiC fiber was remarkably improved by electrochemical surface treatment. SEM analyses reveal that AC current treatment could form a more compact and complete SiO2 layer than DC current on th...The tensile strength of CVD SiC fiber was remarkably improved by electrochemical surface treatment. SEM analyses reveal that AC current treatment could form a more compact and complete SiO2 layer than DC current on the surface of the SiC fiber, which was beneficial to the improvement of tensile strength. It was also verified that AC current was more effective for producing high performance SiC fiber with SiO2 surface layer than DC current. The frequency is a sensitive parameter for the process; but the signals of input current had relatively small effect on the tensile strength of SiC fiber. A further discussion for this phenomenon was completed. The proposed operational parameters are 0.3 A, 5 kHz of sine wave and 91 m/h of the receiving rate respectively.展开更多
The plasma current is modulated with an alternating current (ac) component in a frequency range of 90 Hz - 900 Hz in the plateau discharge phase in the CT-6B tokamak. A plasma electric conductivity profile in a form...The plasma current is modulated with an alternating current (ac) component in a frequency range of 90 Hz - 900 Hz in the plateau discharge phase in the CT-6B tokamak. A plasma electric conductivity profile in a form of (1 - r^2/a^2)^α with a parameter α which is fitted with the experimental data, can be determined. The effects of magnetic shear in a tokamak field configuration on the current penetration are taken into account in the numerical simulation. The measurement method and obtained results are discussed.展开更多
According to the service environment of subway structure,experiment is carried out to simulate influence of different loading levels to reinforcement corrosion of R.C element affected by stray current and chlorine sal...According to the service environment of subway structure,experiment is carried out to simulate influence of different loading levels to reinforcement corrosion of R.C element affected by stray current and chlorine salt solution. The current density of the corrosion is measured with the linear polarization resistance method,together with the qualitative analysis and quantitative calculation. Experiment shows that rebar corrosion current density increase accordingly with the increase of loading level. The quantitative relations and the time of rust corrosion of reinforcement are obtained.展开更多
AC currents are automatically calibrated by two different thermal current converter(TCC)designs.The two designs are different in the used number of the thermal-elements(TEs).Consequently they differ in their output el...AC currents are automatically calibrated by two different thermal current converter(TCC)designs.The two designs are different in the used number of the thermal-elements(TEs).Consequently they differ in their output electro motive force(EMF).Studying the effect of changing the output EMF is done in this paper through calibrating AC currents.5 mA and 5 A are accurately calibrated at different frequencies 55 Hz,1 kHz and10 kHz by the two TCCs.A comparison is made between the results to evaluate the effect of the output EMF value on the accuracy and the uncertainty of the low and higher AC current calibration.A LabVIEW program is designed for this accurate automatic calibration to overcome the problems of the manual calibration on the thermal converters.展开更多
基金Project supported by the National Natural Science Foundation of China (Grant No 10035020).
文摘A two-dimensional, three-temperature radiation magneto-hydrodynamics model is applied to the investigation of evolutional trends in x-ray radiation power, energy, peak plasma temperature and density as functions of drive current rise-time and initial load density distribution by using the typical experimental parameters of tungsten wire-array Z- pinch on the Qiangguang-I generator. The numerical results show that as the drive current rise-time is shortened, x-ray radiation peak power, energy, peak plasma density and peak ion temperature increase approximately linearly, but among them the x-ray radiation peak power increases more quickly. As the initial plasma density distribution in the radial direction becomes gradually flattened, the peak radiation power and the peak ion-temperature almost exponentially increase, while the radiation energy and the peak plasma density change only a little. The main effect of shortening drive current rise-time is to enhance compression of plasma, and the effect of flattening initial load density distribution in the radial direction is to raise the plasma temperature. Both of the approaches elevate the x-ray peak radiation power
基金financially supported by the National Natural Science Foundation of China(Nos.21975287,22179145 and 22138013)Shandong Provincial Natural Science Foundation(No.ZR2020ZD08)+1 种基金the Startup Support Grant from China University of Petroleum(East China)the Technological Development Grant from Shandong Energy Group Co.,Ltd
文摘Conductive substrates with low cost,lightweight,and chemical stability have been highly recognized as alternative current collectors for energy storage devices.Graphite foil is promising to fulfill these requests,whereas the inert surface chemistry denies its possibility as the carrier with high-mass loading active species.Herein,we report a facile yet efficient laser-mediated strategy to fast regulate graphite foils for robustly loading active species.The smooth and hydrophobic graphite foil surface turned to be a rough,super-hydrophilic one containing oxygen-rich clusters after lasering.The reconstructed surface affords anchors for active species,such as nanostruetured MnO_(2),FeOOH,and Fe_(2)O_(3),with the highest loading mass of 20 mg·cm^(-2).The high-mass loading MnO_(2)electrode offers an areal capacitance of 3933 mF·cm^(-2)at 1 mA·cm^(-2).Then,the asymmetric supercapacitor,fabricated by MnO_(2)and Fe_(2)O_(3)deposited laser-irradiated graphite foils,exhibits improved performance with high energy density,large power capability,and long-term stability.The strategy suggests a reliable way to produce alternative current collectors for robust energy storage devices.
文摘The attenuation of the acoustic activity in marble specimens under uniaxial compressive loadingunloading loops is quantified in juxtaposition to that of the electric activity.In parallel,the existence of"pre-failure indiceso"warning about entrance into a critical stage,that of impending fracture,is explored.The acoustic activity is quantified in terms of the normalized number of acoustic hits,their average rate of production and their cumulative energy,and,the cumulative counts and their average rate of change.The electric activity is studied in terms of the pressure stimulated currents and the electric charge released.The analysis revealed that the acoustic and electric activities are linearly correlated to each other,suggesting that they are different manifestations of the same damage mechanisms.In addition,Kaiser's effect,governing the acoustic activity,is found to govern,also,the electric activity.Moreover,it is concluded that entrance into the critical stage is safely predicted by means of a simple criterion,based on the evolution of the average rate of change of the normalized cumulative counts in the natural time domain.These predictions are almost identical with those of the criterion based on the "varianceo" and the "entropies" of the time series of acoustic events in this domain.
文摘In this paper, the boundary value problem (BVP) of 3 D transient eddy current field in the end region in the case that the generator is affected by impact load is specified. Besides, ways to implement discrete methods in both time domain and space domain during the solution of the problem are investigated. The Crank Nicolson scheme is utilized to attain the iterative format of time differential, after taking factors that can ensure both computation precision and stability into consideration. In this paper, the magnetic distribution in the end region of a turbogenerator in the case that the generator is affected by impact load is specified. As a result, it provides foundation for further study of electromagnetic force and electromagnetic vibration in the end region of the turbogenerator.
基金Project supported by the National Natural Science Foundation of China(Grant No.61371033)the Fok Ying-Tung Education Foundation for Young Teachers in the Higher Education Institutions of China(Grant No.142027)+1 种基金the Sichuan Provincial Youth Science and Technology Fund,China(Grant Nos.2014JQ0015and 2013JQ0033)the Fundamental Research Funds for the Central Universities,China(Grant No.SWJTU11CX029)
文摘The discrete iterative map model of peak current-mode controlled buck converter with constant current load(CCL),containing the output voltage feedback and ramp compensation, is established in this paper. Based on this model the complex dynamics of this converter is investigated by analyzing bifurcation diagrams and the Lyapunov exponent spectrum. The effects of ramp compensation and output voltage feedback on the stability of the converter are investigated. Experimental results verify the simulation and theoretical analysis. The stability boundary and chaos boundary are obtained under the theoretical conditions of period-doubling bifurcation and border collision. It is found that there are four operation regions in the peak current-mode controlled buck converter with CCL due to period-doubling bifurcation and border-collision bifurcation. Research results indicate that ramp compensation can extend the stable operation range and transfer the operating mode, and output voltage feedback can eventually eliminate the coexisting fast-slow scale instability.
基金the State Key Laboratory of Coal Resources and Safe Mining,China University of Mining and Technology(No.SKLCRSM22KF011)the National Natural Science Foundation of China(Nos.52130411,52104191,51974120,and 51904103)+1 种基金the Natural Science Foundation of Hunan Province(No.2021JJ40204)the Science and Technology Innovation Program of Hunan Province(No.2020RC3047).
文摘The study of pressure stimulated current(PSC)changes of rocks is significant to monitor dynamic disasters in mines and rock masses.The existing studies focus on change laws and mechanism of currents generated under the loading of rocks.An electrical and mechanics test system was established in this paper to explore the impacts of loading rates on PSCs.The results indicated that PSC curves of different rocks had different change laws under low/high loading rates.When the loading rate was relatively low,PSC curves firstly changed gently and then increased exponentially.Under high loading rates,PSC curves experienced the rapid increase stage,gentle increase stage and sudden change stage.The compressive strength could greatly affect the peak PSC in case of rock failure.The loading rate was a key factor in average PSC.Under low loading rates,the variations of PSCs conformed to the damage charge model of fracture mechanics,while they did not at the fracture moment.Under high loading rates,the PSCs at low stress didn’t fit the model due to the stress impact effects.The experimental results could provide theoretical basis for the influence of loading rates on PSCs.
基金supported by the National Natural Science Foundation of China(Nos.U1806230 and 42025702)the Key Science and Technology Plan of PowerChina Huadong Engineering Corporation(No.KY2018-ZD-01).
文摘Wave-induced liquefaction of the seabed is a geohazard frequently encountered in shallow waters.Although widely discussed,most studies paid attention to the seabed response under a single sequence of wave loading.However,the seabed suffers from repeated‘wave loading–dissipation’phases in a real ocean environment.In this study,a homogeneous sandy seabed model is established to investigate the mechanism of wave-induced liquefaction by considering the existence of currents.Finite element analyses are conducted by incorporating a kinematic hardening elastoplastic model into the commercial package Abaqus.The constitutive model is validated against centrifugal wave tests.Parametric studies are conducted to demonstrate the effects of relative densities,current,and wave-loading history on the seabed response.The predicted excess pore pressure,effective stress paths,and associated variation of relative density are discussed in detail.The results show that the densification of soils significantly enhances the resistance against liquefaction,which provides new insight into the mechanism of residual liquefaction during wave sequences.
基金supported by Chongqing Natural Science Foundation(Grant No.cstc2020jcyj-msxmX0923).
文摘Submerged floating tunnel(SFTs)are typically subjected to complex external environmental and internal loads such as wave currents and traffic load.In this study,this problem is investigated through a finite element method able to account for fluid-structure interaction.The obtained results show that increasing the number of vehicles per unit length enhances the transverse vibrational displacements of the SFT cross sections.Under ultimate traffic load condition,one-way and two-way syntropic distributions can promote the dynamic responses of SFTs whereas two-way reverse distributions have the opposite effect.
文摘The photovoltaic (PV) generator exhibits a nonlinear current-voltage (I-V) characteristic that its maximum power point (MPP) varies with solar insolation. In this paper, a maximum power point tracking (MPPT) method using fuzzy logic control (FLC) is presented. This method is based on the concept of perturbation and observation (P & O) algorithm to track the MPP of a stand-alone PV system. The controller is used to maximize the power generated by the PV array and the simulation of the system is implemented in MATLAB. Simulation results are compared with those obtained by the conventional P & O controller. Results show that the FLC gives better and more reliable control for the stand-alone PV system feeding hybrid loads.
基金the National Natural Science Foundation of China under contract No..59579014.
文摘Using an irregularly oscillating tray and flume, a series of experiments are completed to evaluate bed-load sediment transport rate under irregular wave -current coexistent field. Testing conditions include three interaction angles 0', 45', 90' and two kinds of median sizes (0.38 and 1.10 mm). The results of transport rate show that the net sediment transport rate can be expressed approximately as the function of the maximum bottom shear stress of waves, mean shear stress of current and the grain size.
文摘A dynamic response analysis in the frequency domain is presented for risers subjected to combined wave and current loading. Considering the effects of current, a modified wave spectrum is adopted to compute the linearized drag force. An additional drag force convolution term is added to the linearized drag force spectrum, therefore the error is reduced which arises from the truncation of higher order terms in the drag force auto-correlation function. An expression of linearized drag force spectrum is given taking the relative velocity into account. It is found that the additional term is a fold convolution integral. In this paper dynamic responses of risers are investigated, while the influence of floater motion on risers is considered. The results demonstrate that the accuracy of the present method reaches the degree required in time domain analysis.
文摘The tensile strength of CVD SiC fiber was remarkably improved by electrochemical surface treatment. SEM analyses reveal that AC current treatment could form a more compact and complete SiO2 layer than DC current on the surface of the SiC fiber, which was beneficial to the improvement of tensile strength. It was also verified that AC current was more effective for producing high performance SiC fiber with SiO2 surface layer than DC current. The frequency is a sensitive parameter for the process; but the signals of input current had relatively small effect on the tensile strength of SiC fiber. A further discussion for this phenomenon was completed. The proposed operational parameters are 0.3 A, 5 kHz of sine wave and 91 m/h of the receiving rate respectively.
基金The project supported by the National Natural Science Foundation of China (Nos. 19789502 and 19889506)
文摘The plasma current is modulated with an alternating current (ac) component in a frequency range of 90 Hz - 900 Hz in the plateau discharge phase in the CT-6B tokamak. A plasma electric conductivity profile in a form of (1 - r^2/a^2)^α with a parameter α which is fitted with the experimental data, can be determined. The effects of magnetic shear in a tokamak field configuration on the current penetration are taken into account in the numerical simulation. The measurement method and obtained results are discussed.
基金National Natural Science Foundation of China (Granted No.50808005)National"11-5"Science and Technology Supporting Program(Granted No.2006BAJ27B04)Major Program of Beijing Municipal Natural Science Foundation(Granted No.8100001)
文摘According to the service environment of subway structure,experiment is carried out to simulate influence of different loading levels to reinforcement corrosion of R.C element affected by stray current and chlorine salt solution. The current density of the corrosion is measured with the linear polarization resistance method,together with the qualitative analysis and quantitative calculation. Experiment shows that rebar corrosion current density increase accordingly with the increase of loading level. The quantitative relations and the time of rust corrosion of reinforcement are obtained.
文摘AC currents are automatically calibrated by two different thermal current converter(TCC)designs.The two designs are different in the used number of the thermal-elements(TEs).Consequently they differ in their output electro motive force(EMF).Studying the effect of changing the output EMF is done in this paper through calibrating AC currents.5 mA and 5 A are accurately calibrated at different frequencies 55 Hz,1 kHz and10 kHz by the two TCCs.A comparison is made between the results to evaluate the effect of the output EMF value on the accuracy and the uncertainty of the low and higher AC current calibration.A LabVIEW program is designed for this accurate automatic calibration to overcome the problems of the manual calibration on the thermal converters.