期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Coupling adsorption and in-situ Fenton-like oxidation by iron-containing low-grade attapulgite clay towards organic pollutant removal: From batch experiment to continuous operation
1
作者 Chao Jiang Xiaoli Liu +5 位作者 Xingpeng Wang Qihui Wang Huiyu Li Weiliang Tian Saeed Ahmed Yongjun Feng 《Green Energy & Environment》 2025年第5期1015-1026,共12页
Coupling adsorption and in-situ Fenton-like oxidation process was developed for Methylene blue(MB) using refined iron-containing lowgrade attapulgite(ATP) clay, and the removal mechanism was investigated. The MB was i... Coupling adsorption and in-situ Fenton-like oxidation process was developed for Methylene blue(MB) using refined iron-containing lowgrade attapulgite(ATP) clay, and the removal mechanism was investigated. The MB was initially adsorbed on the porous ATPs, and then the enriched MB was removed by the H2O2-assisted Fenton-like oxidation with the iron-containing ATP catalyst. Under optimal conditions, the ATP powder exhibits the maximum removal efficiency of 100% with negligible iron leaching(1.5 mg L^(-1)) and no sludge formation. Furthermore,polysulfone/ATP(PSF/ATP) pellets were fabricated through a water-induced phase separation process to construct a fixed-bed reactor(FBR) for continuous contaminant removal. For the first cycle, the maximum adsorption capacity was 15.5 L with an outlet MB concentration of1.973 mg L-1(< 2 mg L^(-1), GB4287-2012) using the PSF/ATP pellets containing 50.0 g of ATP powders, and the maximum Fenton-like oxidation capacity was 35.5 L with the outlet concentration of 0.831 mg L^(-1). After five cycles, the total treated volume of the MB solution was ca. 255 L, and the efficiency remained above 99%. After 10 h of continuous treatment towards practical resin industrial wastewater, the chemical oxygen demand(COD) removal efficiency was still measured at 83.05%, costing 0.398 $ m^(-3). These results demonstrate the practical applicability of iron-containing low-grade ATP clay for textile water treatment. 展开更多
关键词 Iron-containing attapulgite coupling strategy ADSORPTION Fenton-like oxidation Fixed-bed reactor
在线阅读 下载PDF
Multi-motor Drive System Based on Adjacent Coupling Error Strategy
2
作者 李艳 何勇 李慧敏 《Journal of Donghua University(English Edition)》 EI CAS 2009年第4期344-349,共6页
A new control strategy named adjacent coupling error strategy is proposed to multi-motor drive system. The adjacent coupling error control scheme is developed considering the tracking speed error in one motor and the ... A new control strategy named adjacent coupling error strategy is proposed to multi-motor drive system. The adjacent coupling error control scheme is developed considering the tracking speed error in one motor and the synchronous error among adjacent motors simultaneously. In the strategy, due to non-linear effects of the two mentioned errors to the motion control of motor i, an adaptive fuzzy logic controller is designed to decide the control variable of the motor drive system. The multi-motor drive system is modeled and simulated by SIMULINK. The simulated researches show that the proposed strategy improves the synchronization, stabilization, and convergence of the multi-motor system. 展开更多
关键词 multi-motor synchronous control adjacent coupling error strategy adaptive fuzzy contrvller biclosed loop control system
在线阅读 下载PDF
上一页 1 下一页 到第