期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Corrosion behavior of as-cast Mg–8Li–3Al+xCe alloy in 3.5wt% NaCl solution 被引量:10
1
作者 S.Manivannan P.Dinesh +3 位作者 R.Mahemaa Nandhakumaran MariyaPillai S.P.Kumaresh Babu Srinivasan Sundarrajan 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2016年第10期1196-1203,共8页
Mg-8Li-3Al+xCe alloys(x = 0.5wt%, 1.0wt%, and 1.5wt%) were prepared through a casting route in an electric resistance furnace under a controlled atmosphere. The cast alloys were characterized by X-ray diffraction, ... Mg-8Li-3Al+xCe alloys(x = 0.5wt%, 1.0wt%, and 1.5wt%) were prepared through a casting route in an electric resistance furnace under a controlled atmosphere. The cast alloys were characterized by X-ray diffraction, optical microscopy, scanning electron microscopy, and energy-dispersive X-ray spectroscopy. The corrosion behavior of the as-cast Mg-8Li-3Al+xCe alloys were studied under salt spray tests in 3.5wt% NaC l solution at 35°C, in accordance with standard ASTM B-117, in conjunction with potentiodynamic polarization(PDP) tests. The results show that the addition of Ce to Mg-8Li-3Al(LA83) alloy results in the formation of Al_2Ce intermetallic phase, refines both the α-Mg phase and the Mg_(17)Al_(12) intermetallic phase, and then increases the microhardness of the alloys. The results of PDP and salt spray tests reveal that an increase in Ce content to 1.5wt% decreases the corrosion rate. The best corrosion resistance is observed for the LA83 alloy sample with 1.0wt% Ce. 展开更多
关键词 magnesium lithium alloys cerium sodium chloride solutions corrosion rate polarization
在线阅读 下载PDF
Pitting Corrosion Behaviour of Monel-400 Alloy in Chloride Solutions 被引量:9
2
作者 V.K.Gouda I.Z.Selim A.A.Khedr and A.M.Fathi(Physical Chemistry Dept., National Research Centre, Dokki, Cairo, Egypt) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 1999年第3期208-212,共5页
Pitting corrosion behaviour of Monel-400 alloy in 3.5 wt pct NaCl sodium chloride solution has been investigated using the cyclic potentiodynamic anodic polarization technique. The effect of chloride ion concentration... Pitting corrosion behaviour of Monel-400 alloy in 3.5 wt pct NaCl sodium chloride solution has been investigated using the cyclic potentiodynamic anodic polarization technique. The effect of chloride ion concentration, pH values and difFerent temperatures on the pitting parameters were determined. The morphology of the pits produced after anodic polarization treatments was inspected by scanning electron microscope (SEM). The results indicated that, the increase in chloride ion concentration shifts Epit and Eprot of the alloy toward negative values and the pitting potential is much more dependent on pH value in the basic region. The breakdown of passivity with increasing temperature may be due to kinetic changes of passivating films and dissolution rate of the alloy in its passive state 展开更多
关键词 FIGURE Pitting corrosion Behaviour of Monel-400 Alloy in Chloride solutions
在线阅读 下载PDF
Effect of microstructure variation on the corrosion behavior of high-strength low-alloy steel in 3.5wt% NaCl solution 被引量:5
3
作者 Yu-bing Guo Chong Li +4 位作者 Yong-chang Liu Li-ming Yu Zong-qing Ma Chen-xi Liu Hui-jun Li 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2015年第6期604-612,共9页
The effect of microstructure variation on the corrosion behavior of high-strength low-alloy(HSLA) steel was investigated. The protective property of the corrosion product layer was also explored. Experimental result... The effect of microstructure variation on the corrosion behavior of high-strength low-alloy(HSLA) steel was investigated. The protective property of the corrosion product layer was also explored. Experimental results reveal that the type of microstructure has significant effect on the corrosion resistance of HSLA steel. The measurement results of weight loss, potentiodynamic polarization curves, and electrochemical impedance spectroscopy indicate that the steel with acicular ferrite microstructure exhibits the lowest corrosion rate. Martensite exhibits a reduced corrosion resistance compared with polygonal ferrite. It is found that the surface of the acicular ferrite specimen uniformly covered by corrosion products is seemingly denser and more compact than those of the other two microstructures, and can provide some amount of protection to the steel; thus, the charge transfer resistance and modulus values of the acicular ferrite specimen are the largest. However, corrosion products on martensite and polygonal ferrite are generally loose, porous, and defective, and can provide minor protectiveness; thus, the charge transfer resistance values for polygonal ferrite and martensite are lower. 展开更多
关键词 high-strength low-alloy steel microstructure corrosion sodium chloride solutions
在线阅读 下载PDF
Synergic Mechanism of an Organic Corrosion Inhibitor for Preventing Carbon Steel Corrosion in Chloride Solution 被引量:5
4
作者 刘志勇 YU Lei LI Qingzhong 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2015年第2期325-330,共6页
The inhibition effect of dimethylethanolamine(DMEA) and its composite with carboxylic acid was studied with the electrochemical tests. The experimental results indicate that DMEA is not a good inhibitor but the comp... The inhibition effect of dimethylethanolamine(DMEA) and its composite with carboxylic acid was studied with the electrochemical tests. The experimental results indicate that DMEA is not a good inhibitor but the composite of DMEA with caprylic acid exhibits excellent inhibiting efficiency. The synergic mechanism of the organic corrosion inhibitors(OCIs) was studied with quantum chemical calculations. It is found that the DMEA forms a quaternary ammonium salt with the proton in carboxylic acid, and a cyclic complex formed between the salt and Fe may be responsible for the enhancement of inhibiting efficiency. The possible hydrogen bond formed between DMEA and carboxylic acid is not enough for the inhibiting effect. This work is helpful to proposing theoretical interpretation as well as developing a functional organic inhibitor to improve the durability of reinforced concrete contaminated with chloride. 展开更多
关键词 carbon steel organic corrosion inhibitor polarization inhibition chloride solution
原文传递
Corrosion Inhibition of Carbon Steel in Hot Hydrochloric Acid Solutions 被引量:5
5
作者 T. Y. Soror(Chemistry Department, Faculty of Science, Cairo University, Cairo, Egypt)H. A.E1 Dahan(Department of Electrochemistry and Corrosion, National Research Centre, Dokki, Cairo, Egypt)N. G.E1 Sayed Ammer(Central Chemical Laboratories, Sabtia, Cairo 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 1999年第6期559-562,共4页
The dissolution of carbon steel in 5% HCl in the temperature range of 30~90℃ was inhibited by two organic compounds having the general formula: ClR NH2(CH2)n NH2 RCl where R is a benzyl group. The behaviour of these ... The dissolution of carbon steel in 5% HCl in the temperature range of 30~90℃ was inhibited by two organic compounds having the general formula: ClR NH2(CH2)n NH2 RCl where R is a benzyl group. The behaviour of these inhibitors in acidic medium were investigated using weight loss method, open circuit potential and linear polarization technique. These inhibitors provided satisfactory corrosion inhibition for carbon steel in hydrochloric acid solutions even at higher temperature and acid concentration (10%). The electrochemical results showed that the polarization resistance (Rp) values increased with increasing inhibitor concentration, also the corrosion current decreased and a higher inhibition efficiency was obtained. The protective properties of these two organic inhibitors were attributed to the chemisorption mechanism 展开更多
关键词 corrosion Inhibition of Carbon Steel in Hot Hydrochloric Acid solutions NH
在线阅读 下载PDF
Effects of applied potential on the stress corrosion cracking behavior of 7003 aluminum alloy in acid and alkaline chloride solutions 被引量:6
6
作者 Xiao-yan Zhang Ren-guo Song +2 位作者 Bin Sun Hai Lu Chao Wang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2016年第7期819-826,共8页
Potentiodynamic polarization tests and slow strain rate test(SSRT) in combination with fracture morphology observations were conducted to investigate the stress corrosion cracking(SCC) behavior of 7003 aluminum al... Potentiodynamic polarization tests and slow strain rate test(SSRT) in combination with fracture morphology observations were conducted to investigate the stress corrosion cracking(SCC) behavior of 7003 aluminum alloy(AA7003) in acid and alkaline chloride solutions under various applied potentials(Ea). The results show that AA7003 is to a certain extent susceptible to SCC via anodic dissolution(AD) at open-circuit potential(OCP) and is highly susceptible to hydrogen embrittlement(HE) at high negative Ea in the solutions with p H levels of 4 and 11. The susceptibility increases with negative shift in the potential when Ea is less than-1000 m V vs. SCE. However, the susceptibility distinctly decreases because of the inhibition of AD when Ea is equal to-1000 m V vs. SCE. In addition, the SCC susceptibility of AA7003 in the acid chloride solution is higher than that in the alkaline solution at each potential. Moreover, the effect of hydrogen on SCC increases with increasing hydrogen ion concentration. 展开更多
关键词 aluminum alloys stress corrosion cracking susceptibility hydrogen embrittlement potential acid solutions alkaline solutions
在线阅读 下载PDF
Transient Current Behaviour for Iron in 3.5%NaCl and 3.5%NaCl+ 1%NaNO_2 Solutions during Corrosion Fatigue
7
作者 Zhengfu WANG Xuejun WEI Jin LI and Wei KE(State Key Lab. for Corrosion and Protection, Institute of Corrosion and Protection of Metals,Chinese Academy of Sciences, Shenyang 110015, China) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 1996年第4期291-298,共8页
The transient current behaviour for Iron in 3.5%NaCl and 3.5%NaCl +1%NaNO2 solutions during corrosion fatigue (CF) process has been investigated at different given strain amplitudes and strain rates. The results show ... The transient current behaviour for Iron in 3.5%NaCl and 3.5%NaCl +1%NaNO2 solutions during corrosion fatigue (CF) process has been investigated at different given strain amplitudes and strain rates. The results show that elastic strain has little contribution to material dissolution. The elastic tension strain results in the decrease in the transient current, while the elastic compression strain increases the transient current. Compared to the elastic deformation, plastic deformation affects material dissolution evidently For iron in 3.5%NaCl solution, the strain amplitude plays a dominant role in the dissolution process accelerated by the plastic strain, while in 3.5%NaCl+1%NaNO2 solution, both the strain amplitude and strain rate play an important role in this process. In this paper, the effect of the elastic deformation on the material dissolution and the relation between the tension and compression current peak values under the plastic cycle deformation are discussed 展开更多
关键词 Transient Current Behaviour for Iron in 3.5%NaCl and 3.5%NaCl SCE NaNO2 solutions during corrosion Fatigue
在线阅读 下载PDF
Effect of Corrosive Solutions on C-S-H Microstructure in Portland Cement Paste with Fly Ash 被引量:3
8
作者 丁庆军 WANG Huan +1 位作者 HU Chenguang 张高展 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2016年第5期1002-1007,共6页
By means of ^(29)Si and ^(27)Al magic angle spinning nuclear magnetic resonance(MAS NMR) combined with deconvolution technique, X-ray diffraction(XRD), scanning electron microscopy(SEM) as well as energy dis... By means of ^(29)Si and ^(27)Al magic angle spinning nuclear magnetic resonance(MAS NMR) combined with deconvolution technique, X-ray diffraction(XRD), scanning electron microscopy(SEM) as well as energy dispersive X-ray system(EDX), the effect of 5 wt% corrosive solutions( viz. 5 wt% Na_2SO_4, MgSO_4, Na_2SO_^(4+)Na Cl and Na_2SO_^(4+)Na Cl+Na_2CO_3) on C-S-H microstructure in portland cement containing 30 wt% fly ash was investigated.The results show that, in MgSO_4 solution, Mg2+ promotes the decalcification of C-S-H by SO_4^(2-),increasing silicate tetrahedra polymerization and mean chain length(MCL) of C-S-H. However, the substituting degree of Al^(3+) for Si^(4+)(Al[4]/Si) in the paste does not change evidently. Effect of Na_2SO_4 solution on C-S-H is not significantly influenced by Na Cl solution, while the MCL and Al[4]/Si of C-S-H in fly ashcement paste slightly change. However, the decalcification of C-S-H by SO_4^(2-) and CO_3^(2-) attack, as well as the activation of fly ash by SO_4^(2-) attack will increase the MCL and Al[4]/Si, which are both higher than that under Na_2SO_4 corrosion, MgSO_4 or Na_2SO_4 +Na Cl coordination corrosion. 展开更多
关键词 corrosive solutions cement fly ash C-S-H microstructure /Si
原文传递
SCC investigation of low alloy ultra-high strength steel 30CrMnSiNi2A in 3.5wt% NaCl solution by slow strain rate technique 被引量:3
9
作者 Liu Jianhua Guo Qiang +1 位作者 Yu Mei Li Songmei 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2014年第5期1327-1333,共7页
To evaluate stress corrosion cracking(SCC) mechanism of low alloy ultra-high strength steel 30CrMnSiNi2 A in environment containing NaCl, SCC behavior of the steel in 3.5wt% NaCl solution is investigated by slow str... To evaluate stress corrosion cracking(SCC) mechanism of low alloy ultra-high strength steel 30CrMnSiNi2 A in environment containing NaCl, SCC behavior of the steel in 3.5wt% NaCl solution is investigated by slow strain rate technique(SSRT) with various strain rates and applied potentials, surface analysis technique, and electrochemical measurements. SCC susceptibility of the steel increases rapidly with strain rate decreasing from 1 · 10 5s 1to 5 · 10 7s 1, and becomes stable when strain rate is lower than 5 · 10 7s 1. SCC propagation of the steel in the solution at open circuit potential(OCP) needs sufficient hydrogen which is supplied at a certain strain rate.Fracture surface at OCP has similar characteristics with that at cathodic polarization 1000 mVSCE, which presents characteristic fractography of hydrogen induced cracking(HIC).All of these indicate that SCC behavior of the steel in the solution at OCP is mainly controlled by HIC rather than anodic dissolution(AD). 展开更多
关键词 Hydrogen NaCl solution Stress corrosion cracking Slow strain rate technique Ultra-high strength steel
原文传递
The Influence of Ce(NO_3)_3·6H_2O on the Inhibitive Effect of Ca(NO_2)_2 in Simulated Concrete Pore Solution
10
作者 冯兴国 左禹 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2012年第5期994-998,共5页
The effects of cerium nitrite on corrosion behaviors of carbon steel in simulated concrete pore solutions were studied with the methods of linear polarization, electrochemical impedance spectroscopy and surface analys... The effects of cerium nitrite on corrosion behaviors of carbon steel in simulated concrete pore solutions were studied with the methods of linear polarization, electrochemical impedance spectroscopy and surface analysis. In pore solutions in the presence of Ce(NO3)3?6H2O, the corrosion potential, polarization resistance and impedance of carbon steel obviously increased in contrast to the situation in the absence of cerium salts. The pore solution with [NO2-] / [Cl-] = 0.3 and 0.1% Ce(NO3)3?6H2O, carbon steel shows better corrosion resistance than that in the pore solution with [NO2-] / [Cl-] = 0.6, which indicates that a small amount of Ce(NO3)3?6H2O in pore solutions can effectively promote passivation of the steel and reduce the threshold [NO2-] / [Cl-] ratio for corrosion control. The surface layer formed in cerium salt containing pore solutions is more compact and smooth and 1.36%Ce is examined on the sample surface. The addition of 0.1% Ce(NO3)3?6H2O in pore solutions can decrease the corrosion rate of steel in pore solutions and has little influence on pH change of the solutions. However, more cerium nitrate addition above 0.1% may result in pH decrease of the solution. 展开更多
关键词 concrete pore solution corrosion inhibitor critical concentration Ce(NO3)3
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部