AIM:To observe the effects of femtosecond laserassisted excimer laser in situ keratomileusis combined with accelerated corneal cross-linking(FS-LASIK Xtra)on corneal densitometry after correcting for high myopia.METHO...AIM:To observe the effects of femtosecond laserassisted excimer laser in situ keratomileusis combined with accelerated corneal cross-linking(FS-LASIK Xtra)on corneal densitometry after correcting for high myopia.METHODS:In this prospectively study,130 patients underwent FS-LASIK or FS-LASIK Xtra for high myopia.Their right eyes were selected for inclusion in the study,of which 65 cases of 65 eyes in the FS-LASIK group,65 patients with 65 eyes in the FS-LASIK Xtra group.Patients were evaluated for corneal densitometry at 1,3,and 6mo postoperatively using Pentacam Scheimpflug imaging.RESULTS:Preoperative differences in corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups in different ranges were not statistically significant(P>0.05).Layer-by-layer analysis revealed statistically significant differences in the anterior(120μm),central,and total layer corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups at 1 and 3mo postoperatively(all P<0.05),the FS-LASIK Xtra group is higher than that of the FS-LASIK group.Analysis of different diameter ranges showed statistically significant differences between the FS-LASIK group and the FS-LASIK Xtra group at 1mo postoperatively in the ranges of 0–2,2–6,and 6–10 mm(both P<0.05);At 3mo postoperatively,the FS-LASIK Xtra group is higher than that of the FS-LASIK group in the ranges of 0–2 and 2–6 mm(P<0.05).At 6mo postoperatively,there were no statistically significant differences in corneal densitometry between the FS-LASIK group and the FS-LASIK Xtra group in different diameter ranges(all P>0.05).CONCLUSION:There is an increase in internal corneal densitometry during the early postoperative period after FS-LASIK Xtra for correction of high myopia.However,the densitometry values decreased to the level of conventional FS-LASIK at 6mo after surgery,with the most significant changes observed in the superficial central zone.展开更多
●AIM:To investigate the long-term changes of corneal densitometry(CD)and its contributing elements after small incision lenticule extraction(SMILE).●METHODS:Totally 31 eyes of 31 patients with mean spherical equival...●AIM:To investigate the long-term changes of corneal densitometry(CD)and its contributing elements after small incision lenticule extraction(SMILE).●METHODS:Totally 31 eyes of 31 patients with mean spherical equivalent of-6.46±1.50 D and mean age 28.23±7.38y were enrolled.Full-scale examinations were conducted on all patients preoperatively and during followup.Visual acuity,manifest refraction,axial length,corneal thickness,corneal higher-order aberrations,and CD were evaluated.●RESULTS:All surgeries were completed successfully without complications or adverse events.Ten-year safety index was 1.17±0.20 and efficacy 1.04±0.28.CD value of 0–6 mm zones in central layer was statistically significantly lower 10y postoperatively,compared with preoperative values(0–2 mmΔ=-1.62,2–6 mmΔ=-1.24,P<0.01).There were no correlations between CD values and factors evaluated.●CONCLUSION:SMILE is a safe and efficient procedure for myopia on a long-term basis.CD values get lower 10y postoperatively,whose mechanism is to be further discussed.展开更多
Objective To compare early postoperative changes in corneal densitometry after small incision lenticule extraction using 120-μm and 130-μm cap thicknesses.Methods 69 eyes of 39 patients who underwent small incision ...Objective To compare early postoperative changes in corneal densitometry after small incision lenticule extraction using 120-μm and 130-μm cap thicknesses.Methods 69 eyes of 39 patients who underwent small incision lenticule extraction(SMILE)with cap thicknesses of 120-μm(n=34)and 130-μm(n=35)were included in this study.The corneal densitometry(CD)of three zones(0–2mm,2–6mm,and 6–10mm)of the anterior,central,and posterior corneal layers was evaluated before,one week,and one month after surgery.Uncorrected distance visual acuity(UDVA),corrected distance visual acuity(CDVA),spherical degree,cylinder degree,and spherical equivalent(SE)were also analyzed and compared between the two groups before and after surgery.Results Little difference was detected between the two groups in postoperative UCVA,BCVA,SE,and cylinder degree at one month.No statistically significant differences were found between the preoperative and postoperative CD values for the overall(0–12mm)cornea and the 6–10mm zone in either group.A significant increase in CD was observed in the 0–2mm and 2–6mm zones of the anterior layer in the 120-μm group,and the 0–2mm zone of the central layer in the 130-μm group,one week postoperatively.These changes persisted for one month after surgery(P<0.05).The CD in the central layer(0–2mm and 2–6mm)in the 120-μm group,as well as the total layer(0–2mm and 2–6mm)in both groups,significantly increased at the first postoperative week but returned to preoperative levels by one month after surgery.Additionally,the CD of the anterior layer(0–2mm and 2–6mm)increased significantly in the first week postoperatively,decreased significantly one month postoperatively,but remained significantly higher than baseline in the 130-μm group.In both groups,the CD of the posterior 0–2mm zone decreased.Moreover,the increase in CD in the anterior 2–6mm zone one week postoperatively was significantly higher in the 120-μm group compared to the 130-μm group(ΔCD 2.4±1.55 vs.1.64±0.87,P=0.014).Postoperative corneal wavefront aberrations were significantly higher in the 120-μm group than in the 130-μm group.Conclusions CD increased mainly in the 0–6mm zone of the anterior layer in the early phase after the SMILE procedure with both the 120-μm and 130-μm groups.The increase in CD in the anterior 2–6mm zone one week postoperatively was higher in the 120-μm group than in the 130-μm group.SMILE with 120-μm and 130-μm cap thickness were both efficient and safe,but eyes with a 120-μm cap thickness showed higher postoperative corneal wavefront aberrations.展开更多
AIM:To evaluate changes in corneal light scattering and anterior segment parameters in newly diagnosed rheumatoid arthritis(RA)patients who achieved remission with systemic treatment,compared to healthy controls.METHO...AIM:To evaluate changes in corneal light scattering and anterior segment parameters in newly diagnosed rheumatoid arthritis(RA)patients who achieved remission with systemic treatment,compared to healthy controls.METHODS:A cross-sectional study was conducted at a tertiary care hospital,in ophthalmology,and rheumatology departments.A total of 42 RA patients(13 men and 29 women)and 56 healthy individuals(23 men 33 women)underwent comprehensive ophthalmologic evaluations,including Scheimpflug corneal densitometry and Pentacam HR measurements.Those who initiated systemic treatment for RA were monitored at first,third,and sixth-month follow-ups.Participants who achieved remission at each follow-up assessment were included.RESULTS:Significant differences in corneal densitometry were observed,with higher values in RA patients,particularly in the middle and posterior layers.Anterior segment parameters such as anterior chamber volume and angle were significantly reduced in RA patients compared to other groups(P<0.001).Following systemic treatment and achievement of remission,these parameters showed regression toward normal values.CONCLUSION:The study underscores the potential utility of corneal densitometry and anterior segment analysis as sensitive indicators of subclinical ocular involvement in RA,offering insights into disease progression and treatment efficacy.These findings highlight the importance of early detection and regular monitoring in preventing vision-threatening complications in RA patients.展开更多
AIM:To investigate the safety and efficacy of using a onestep viscoelastic agent technique for posterior chamber phakic implantable collamer lens with a central hole(ICL V4 c)implantation for myopia correction.METHODS...AIM:To investigate the safety and efficacy of using a onestep viscoelastic agent technique for posterior chamber phakic implantable collamer lens with a central hole(ICL V4 c)implantation for myopia correction.METHODS:The one-step viscoelastic agent technique for ICL V4 c implantation was used in 100 eyes of 52 patients.Refractive outcomes,intraocular pressure(IOP),corneal endothelial cell,and corneal densitometry values were evaluated at 1 d,1 wk,1 and 3 mo postoperatively.RESULTS:All the surgeries were uneventful.No corrected distance visual acuity was lost after 3 mo.IOP was 16.12±3.18 mm Hg before surgery,and 14.74±3.08 mm Hg at 1d and 14.50±2.56 mm Hg at 3 mo after surgery(P<0.05).Corneal endothelial cell density was 2580±242 cell/mm^(2),the coefficient of variation in cell size was 42.11%±7.92%,and the percentage of hexagonal cells was 40.98%±9.46%before surgery.No significant difference was found when these outcomes were compared between the studied time points(P>0.05).The corneal densitometry values of the central 2 mm and 2 to 6 mm areas showed similar regularities.After surgery,the values significantly increased at 1 d,then decreased to the preoperative values at 1 wk,and then continued to decrease at 3 mo(P<0.05).CONCLUSION:The one-step viscoelastic agent technique for ICL V4c implantation is found to be safe and effective for myopia correction and causes little disturbance to the cornea.展开更多
Background:To explore corneal biomechanical changes,identify related factors and determine early indicators of keratoconus(KC)development risk in allergic conjunctivitis(AC)patients.Methods:A total of 50 patients,incl...Background:To explore corneal biomechanical changes,identify related factors and determine early indicators of keratoconus(KC)development risk in allergic conjunctivitis(AC)patients.Methods:A total of 50 patients,including 20 eyes without AC and 30 eyes with AC were enrolled in this study.All patients underwent a complete ocular examination,including evaluations of clinical manifestations of AC,corneal tomography and densitometry by Pentacam,corneal biomechanics by Corvis ST,and corneal and epithelial thickness mapping by RTvue optical coherence tomography(OCT).Results:The index of surface variance(ISV),index of vertical asymmetry(IVA),keratoconus index(KI),index of height decentration(IHD)and Belin/Ambrosio enhanced ectasia total deviation index(BAD-D)were significantly higher in the AC group than in the non-allergic conjunctivitis(NAC)group(P<0.05).The tomography and biomechanical index(TBI)was also significantly higher in the AC group(P=0.04).The average epithelial thickness in the 2-7mm annulus was significantly thinner in the AC group than in the NAC group(P<0.05).The average densitometry of the total cornea and the anterior layer were higher in the AC group than in the NAC group(P<0.001).The ISV,IVA,KI,IHD and BAD-D were significantly correlated with the TBI and changes in corneal epithelial thickness in AC patients(P<0.05).The changes in epithelial thickness were closely related to the eye rubbing frequency and allergic sign scores(P<0.05).Conclusions:AC patients should be advised to routinely undergo corneal tomographic and biomechanical measurements,and the TBI could be used as an indicator of KC development risk in AC patients.展开更多
Background:To explore corneal biomechanical changes,identify related factors and determine early indicators of keratoconus(KC)development risk in allergic conjunctivitis(AC)patients.Methods:A total of 50 patients,incl...Background:To explore corneal biomechanical changes,identify related factors and determine early indicators of keratoconus(KC)development risk in allergic conjunctivitis(AC)patients.Methods:A total of 50 patients,including 20 eyes without AC and 30 eyes with AC were enrolled in this study.All patients underwent a complete ocular examination,including evaluations of clinical manifestations of AC,corneal tomography and densitometry by Pentacam,corneal biomechanics by Corvis ST,and corneal and epithelial thickness mapping by RTvue optical coherence tomography(OCT).Results:The index of surface variance(ISV),index of vertical asymmetry(IVA),keratoconus index(KI),index of height decentration(IHD)and Belin/Ambrosio enhanced ectasia total deviation index(BAD-D)were significantly higher in the AC group than in the non-allergic conjunctivitis(NAC)group(P<0.05).The tomography and biomechanical index(TBl)was also significantly higher in the AC group(P=0.04).The average epithelial thickness in the 2-7 mm annulus was significantly thinner in the AC group than in the NAC group(P<0.05).The average densitometry of the total cornea and the anterior layer were higher in the AC group than in the NAC group(P<0.001).The ISV,IVA,KI,IHD and BAD-D were significantly correlated with the TBI and changes in corneal epithelial thickness in AC patients(P<0.05).The changes in epithelial thickness were closely related to the eye rubbing frequency and allergic sign scores(P<0.05).Conclusions:AC patients should be advised to routinely undergo corneal tomographic and biomechanical measurements,and the TBl could be used as an indicator of KC development risk in AC patients.Trial registration:Corneal Biomechanical Changes of Allergic Conjunctivitis,NCT04299399.Registered March 3,2020-Retrospectively registered.展开更多
Background:To investigate the topographic measurements and densitometry of corneas in Wilson's disease(WD)patients with or without a Kayser-Fleischer ring(KF-r)compared to healthy individuals.Methods:This cross-se...Background:To investigate the topographic measurements and densitometry of corneas in Wilson's disease(WD)patients with or without a Kayser-Fleischer ring(KF-r)compared to healthy individuals.Methods:This cross-sectional study included 20 WD patients without a KF-r(group I),18 WD patients with a KF-r(groupⅠ),and 20 age-matched controls(group Ⅱ).The Pentacam high-resolution imaging system is used to determine corneal topographic measurements and densitometry.Results:Mean age for groups Ⅰ,Ⅱ and Ⅲ was 25.40±6.43 years(14-36 years),25.38±6.96 years(16-39 years),and 23.60±6.56 years(17-35 years),respectively(P=0.623).There was no significant difference between the groups in terms of the anterior corneal densitometry values(P>0.05),while the 6-10 mm and 10-12 mm midstroma and the 2-6 mm,6-10 mm,and 10-12 mm posterior corneal densitometry values in group Ⅱ were significantly higher than those in groups Ⅰ and Ⅱ(for all values,P<0.05).However,the 10-12 mm posterior corneal densitometry values in group Ⅰ were also significantly higher than those in group Ⅲ(P=0.038).The central corneal thickness(CCT),thinnest corneal thickness(tCT),and corneal volume(CV)values in groups Ⅰ and Ⅱ were significantly lower than those in group Ⅱ(for CCT values,P=0.011 and P=0.009;for tCT values,P=0.010 and P=0.005;for CV values,P=0.043 and P=0.029).Conclusion:In WD patients with a KF-r,corneal transparency decreased in the peripheral posterior and midstromal corneal layers;for these patients,corneal transparency may be impaired not only in the peripheral cornea but also in the paracentral cornea.展开更多
Background:To investigate the topographic measurements and densitometry of corneas in Wilson’s disease(WD)patients with or without a Kayser-Fleischer ring(KF-r)compared to healthy individuals.Methods:This cross-secti...Background:To investigate the topographic measurements and densitometry of corneas in Wilson’s disease(WD)patients with or without a Kayser-Fleischer ring(KF-r)compared to healthy individuals.Methods:This cross-sectional study included 20 WD patients without a KF-r(group I),18 WD patients with a KF-r(group II),and 20 age-matched controls(group III).The Pentacam high resolution imaging system is used to determine corneal topographic measurements and densitometry.Results:Mean age for groups I,II and III was 25.40±6.43 years(14-36 years),25.38±6.96 years(16-39 years),23.60±6.56 years(17-35 years),respectively(P=0.623).There was no significant difference between the groups in terms of the anterior corneal densitometry values(P>0.05),while the 6-10mm and 10-12 mm mid stroma and the 2-6 mm,6-10 mm,and 10-12 mm posterior corneal densitometry values in group II were significantly higher than those in groups I and III(for all values,P<0.05).However,the 10-12mm posterior corneal densitometry values in group I were also significantly higher than those in group III(P=0.038).The central corneal thickness(CCT),thinnest corneal thickness(tCT),and corneal volume(CV)values in groups I and II were significantly lower than those in group III(for CCT values,P=0.011 and P=0.009;for tCT values,P=0.010 and P=0.005;for CV values,P=0.043 and P=0.029).Conclusion:In WD patients with a KF-r,corneal transparency decreased in the peripheral posterior and mid stromal corneal layers;for these patients,corneal transparency may be impaired not only in the peripheral cornea but also in the paracentral cornea.展开更多
基金Supported by Shandong Province Medical Staff Science and Technology Innovation Program Project(No.SDYWZGKCJH2022021).
文摘AIM:To observe the effects of femtosecond laserassisted excimer laser in situ keratomileusis combined with accelerated corneal cross-linking(FS-LASIK Xtra)on corneal densitometry after correcting for high myopia.METHODS:In this prospectively study,130 patients underwent FS-LASIK or FS-LASIK Xtra for high myopia.Their right eyes were selected for inclusion in the study,of which 65 cases of 65 eyes in the FS-LASIK group,65 patients with 65 eyes in the FS-LASIK Xtra group.Patients were evaluated for corneal densitometry at 1,3,and 6mo postoperatively using Pentacam Scheimpflug imaging.RESULTS:Preoperative differences in corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups in different ranges were not statistically significant(P>0.05).Layer-by-layer analysis revealed statistically significant differences in the anterior(120μm),central,and total layer corneal densitometry between the FS-LASIK and FS-LASIK Xtra groups at 1 and 3mo postoperatively(all P<0.05),the FS-LASIK Xtra group is higher than that of the FS-LASIK group.Analysis of different diameter ranges showed statistically significant differences between the FS-LASIK group and the FS-LASIK Xtra group at 1mo postoperatively in the ranges of 0–2,2–6,and 6–10 mm(both P<0.05);At 3mo postoperatively,the FS-LASIK Xtra group is higher than that of the FS-LASIK group in the ranges of 0–2 and 2–6 mm(P<0.05).At 6mo postoperatively,there were no statistically significant differences in corneal densitometry between the FS-LASIK group and the FS-LASIK Xtra group in different diameter ranges(all P>0.05).CONCLUSION:There is an increase in internal corneal densitometry during the early postoperative period after FS-LASIK Xtra for correction of high myopia.However,the densitometry values decreased to the level of conventional FS-LASIK at 6mo after surgery,with the most significant changes observed in the superficial central zone.
文摘●AIM:To investigate the long-term changes of corneal densitometry(CD)and its contributing elements after small incision lenticule extraction(SMILE).●METHODS:Totally 31 eyes of 31 patients with mean spherical equivalent of-6.46±1.50 D and mean age 28.23±7.38y were enrolled.Full-scale examinations were conducted on all patients preoperatively and during followup.Visual acuity,manifest refraction,axial length,corneal thickness,corneal higher-order aberrations,and CD were evaluated.●RESULTS:All surgeries were completed successfully without complications or adverse events.Ten-year safety index was 1.17±0.20 and efficacy 1.04±0.28.CD value of 0–6 mm zones in central layer was statistically significantly lower 10y postoperatively,compared with preoperative values(0–2 mmΔ=-1.62,2–6 mmΔ=-1.24,P<0.01).There were no correlations between CD values and factors evaluated.●CONCLUSION:SMILE is a safe and efficient procedure for myopia on a long-term basis.CD values get lower 10y postoperatively,whose mechanism is to be further discussed.
文摘Objective To compare early postoperative changes in corneal densitometry after small incision lenticule extraction using 120-μm and 130-μm cap thicknesses.Methods 69 eyes of 39 patients who underwent small incision lenticule extraction(SMILE)with cap thicknesses of 120-μm(n=34)and 130-μm(n=35)were included in this study.The corneal densitometry(CD)of three zones(0–2mm,2–6mm,and 6–10mm)of the anterior,central,and posterior corneal layers was evaluated before,one week,and one month after surgery.Uncorrected distance visual acuity(UDVA),corrected distance visual acuity(CDVA),spherical degree,cylinder degree,and spherical equivalent(SE)were also analyzed and compared between the two groups before and after surgery.Results Little difference was detected between the two groups in postoperative UCVA,BCVA,SE,and cylinder degree at one month.No statistically significant differences were found between the preoperative and postoperative CD values for the overall(0–12mm)cornea and the 6–10mm zone in either group.A significant increase in CD was observed in the 0–2mm and 2–6mm zones of the anterior layer in the 120-μm group,and the 0–2mm zone of the central layer in the 130-μm group,one week postoperatively.These changes persisted for one month after surgery(P<0.05).The CD in the central layer(0–2mm and 2–6mm)in the 120-μm group,as well as the total layer(0–2mm and 2–6mm)in both groups,significantly increased at the first postoperative week but returned to preoperative levels by one month after surgery.Additionally,the CD of the anterior layer(0–2mm and 2–6mm)increased significantly in the first week postoperatively,decreased significantly one month postoperatively,but remained significantly higher than baseline in the 130-μm group.In both groups,the CD of the posterior 0–2mm zone decreased.Moreover,the increase in CD in the anterior 2–6mm zone one week postoperatively was significantly higher in the 120-μm group compared to the 130-μm group(ΔCD 2.4±1.55 vs.1.64±0.87,P=0.014).Postoperative corneal wavefront aberrations were significantly higher in the 120-μm group than in the 130-μm group.Conclusions CD increased mainly in the 0–6mm zone of the anterior layer in the early phase after the SMILE procedure with both the 120-μm and 130-μm groups.The increase in CD in the anterior 2–6mm zone one week postoperatively was higher in the 120-μm group than in the 130-μm group.SMILE with 120-μm and 130-μm cap thickness were both efficient and safe,but eyes with a 120-μm cap thickness showed higher postoperative corneal wavefront aberrations.
文摘AIM:To evaluate changes in corneal light scattering and anterior segment parameters in newly diagnosed rheumatoid arthritis(RA)patients who achieved remission with systemic treatment,compared to healthy controls.METHODS:A cross-sectional study was conducted at a tertiary care hospital,in ophthalmology,and rheumatology departments.A total of 42 RA patients(13 men and 29 women)and 56 healthy individuals(23 men 33 women)underwent comprehensive ophthalmologic evaluations,including Scheimpflug corneal densitometry and Pentacam HR measurements.Those who initiated systemic treatment for RA were monitored at first,third,and sixth-month follow-ups.Participants who achieved remission at each follow-up assessment were included.RESULTS:Significant differences in corneal densitometry were observed,with higher values in RA patients,particularly in the middle and posterior layers.Anterior segment parameters such as anterior chamber volume and angle were significantly reduced in RA patients compared to other groups(P<0.001).Following systemic treatment and achievement of remission,these parameters showed regression toward normal values.CONCLUSION:The study underscores the potential utility of corneal densitometry and anterior segment analysis as sensitive indicators of subclinical ocular involvement in RA,offering insights into disease progression and treatment efficacy.These findings highlight the importance of early detection and regular monitoring in preventing vision-threatening complications in RA patients.
基金the National Natural Science Foundation of China for Young Scholars(No.81700872)the National Natural Science Foundation of China(No.81770955)+4 种基金the Project of Shanghai Science and Technology(No.17411950200No.20410710100)the Joint Research Project of New Frontier Technology in Municipal Hospitals(No.SHDC12018103)the Clinical Research Plan of SHDC(No.SHDC2020CR1043B)the Project of Shanghai Xuhui District Science and Technology(No.2020-015)。
文摘AIM:To investigate the safety and efficacy of using a onestep viscoelastic agent technique for posterior chamber phakic implantable collamer lens with a central hole(ICL V4 c)implantation for myopia correction.METHODS:The one-step viscoelastic agent technique for ICL V4 c implantation was used in 100 eyes of 52 patients.Refractive outcomes,intraocular pressure(IOP),corneal endothelial cell,and corneal densitometry values were evaluated at 1 d,1 wk,1 and 3 mo postoperatively.RESULTS:All the surgeries were uneventful.No corrected distance visual acuity was lost after 3 mo.IOP was 16.12±3.18 mm Hg before surgery,and 14.74±3.08 mm Hg at 1d and 14.50±2.56 mm Hg at 3 mo after surgery(P<0.05).Corneal endothelial cell density was 2580±242 cell/mm^(2),the coefficient of variation in cell size was 42.11%±7.92%,and the percentage of hexagonal cells was 40.98%±9.46%before surgery.No significant difference was found when these outcomes were compared between the studied time points(P>0.05).The corneal densitometry values of the central 2 mm and 2 to 6 mm areas showed similar regularities.After surgery,the values significantly increased at 1 d,then decreased to the preoperative values at 1 wk,and then continued to decrease at 3 mo(P<0.05).CONCLUSION:The one-step viscoelastic agent technique for ICL V4c implantation is found to be safe and effective for myopia correction and causes little disturbance to the cornea.
基金supported by grants from the Key Area Research and Development Program of Guangdong Province(No.2019B010152001)the National Natural Science Foundation of China(81670826).
文摘Background:To explore corneal biomechanical changes,identify related factors and determine early indicators of keratoconus(KC)development risk in allergic conjunctivitis(AC)patients.Methods:A total of 50 patients,including 20 eyes without AC and 30 eyes with AC were enrolled in this study.All patients underwent a complete ocular examination,including evaluations of clinical manifestations of AC,corneal tomography and densitometry by Pentacam,corneal biomechanics by Corvis ST,and corneal and epithelial thickness mapping by RTvue optical coherence tomography(OCT).Results:The index of surface variance(ISV),index of vertical asymmetry(IVA),keratoconus index(KI),index of height decentration(IHD)and Belin/Ambrosio enhanced ectasia total deviation index(BAD-D)were significantly higher in the AC group than in the non-allergic conjunctivitis(NAC)group(P<0.05).The tomography and biomechanical index(TBI)was also significantly higher in the AC group(P=0.04).The average epithelial thickness in the 2-7mm annulus was significantly thinner in the AC group than in the NAC group(P<0.05).The average densitometry of the total cornea and the anterior layer were higher in the AC group than in the NAC group(P<0.001).The ISV,IVA,KI,IHD and BAD-D were significantly correlated with the TBI and changes in corneal epithelial thickness in AC patients(P<0.05).The changes in epithelial thickness were closely related to the eye rubbing frequency and allergic sign scores(P<0.05).Conclusions:AC patients should be advised to routinely undergo corneal tomographic and biomechanical measurements,and the TBI could be used as an indicator of KC development risk in AC patients.
基金supported by the Key Area Research and Development Program of Guangdong Province(Grant No.2019B010152001)the National Natural Science Foundation of China(Grant No.81670826).
文摘Background:To explore corneal biomechanical changes,identify related factors and determine early indicators of keratoconus(KC)development risk in allergic conjunctivitis(AC)patients.Methods:A total of 50 patients,including 20 eyes without AC and 30 eyes with AC were enrolled in this study.All patients underwent a complete ocular examination,including evaluations of clinical manifestations of AC,corneal tomography and densitometry by Pentacam,corneal biomechanics by Corvis ST,and corneal and epithelial thickness mapping by RTvue optical coherence tomography(OCT).Results:The index of surface variance(ISV),index of vertical asymmetry(IVA),keratoconus index(KI),index of height decentration(IHD)and Belin/Ambrosio enhanced ectasia total deviation index(BAD-D)were significantly higher in the AC group than in the non-allergic conjunctivitis(NAC)group(P<0.05).The tomography and biomechanical index(TBl)was also significantly higher in the AC group(P=0.04).The average epithelial thickness in the 2-7 mm annulus was significantly thinner in the AC group than in the NAC group(P<0.05).The average densitometry of the total cornea and the anterior layer were higher in the AC group than in the NAC group(P<0.001).The ISV,IVA,KI,IHD and BAD-D were significantly correlated with the TBI and changes in corneal epithelial thickness in AC patients(P<0.05).The changes in epithelial thickness were closely related to the eye rubbing frequency and allergic sign scores(P<0.05).Conclusions:AC patients should be advised to routinely undergo corneal tomographic and biomechanical measurements,and the TBl could be used as an indicator of KC development risk in AC patients.Trial registration:Corneal Biomechanical Changes of Allergic Conjunctivitis,NCT04299399.Registered March 3,2020-Retrospectively registered.
文摘Background:To investigate the topographic measurements and densitometry of corneas in Wilson's disease(WD)patients with or without a Kayser-Fleischer ring(KF-r)compared to healthy individuals.Methods:This cross-sectional study included 20 WD patients without a KF-r(group I),18 WD patients with a KF-r(groupⅠ),and 20 age-matched controls(group Ⅱ).The Pentacam high-resolution imaging system is used to determine corneal topographic measurements and densitometry.Results:Mean age for groups Ⅰ,Ⅱ and Ⅲ was 25.40±6.43 years(14-36 years),25.38±6.96 years(16-39 years),and 23.60±6.56 years(17-35 years),respectively(P=0.623).There was no significant difference between the groups in terms of the anterior corneal densitometry values(P>0.05),while the 6-10 mm and 10-12 mm midstroma and the 2-6 mm,6-10 mm,and 10-12 mm posterior corneal densitometry values in group Ⅱ were significantly higher than those in groups Ⅰ and Ⅱ(for all values,P<0.05).However,the 10-12 mm posterior corneal densitometry values in group Ⅰ were also significantly higher than those in group Ⅲ(P=0.038).The central corneal thickness(CCT),thinnest corneal thickness(tCT),and corneal volume(CV)values in groups Ⅰ and Ⅱ were significantly lower than those in group Ⅱ(for CCT values,P=0.011 and P=0.009;for tCT values,P=0.010 and P=0.005;for CV values,P=0.043 and P=0.029).Conclusion:In WD patients with a KF-r,corneal transparency decreased in the peripheral posterior and midstromal corneal layers;for these patients,corneal transparency may be impaired not only in the peripheral cornea but also in the paracentral cornea.
文摘Background:To investigate the topographic measurements and densitometry of corneas in Wilson’s disease(WD)patients with or without a Kayser-Fleischer ring(KF-r)compared to healthy individuals.Methods:This cross-sectional study included 20 WD patients without a KF-r(group I),18 WD patients with a KF-r(group II),and 20 age-matched controls(group III).The Pentacam high resolution imaging system is used to determine corneal topographic measurements and densitometry.Results:Mean age for groups I,II and III was 25.40±6.43 years(14-36 years),25.38±6.96 years(16-39 years),23.60±6.56 years(17-35 years),respectively(P=0.623).There was no significant difference between the groups in terms of the anterior corneal densitometry values(P>0.05),while the 6-10mm and 10-12 mm mid stroma and the 2-6 mm,6-10 mm,and 10-12 mm posterior corneal densitometry values in group II were significantly higher than those in groups I and III(for all values,P<0.05).However,the 10-12mm posterior corneal densitometry values in group I were also significantly higher than those in group III(P=0.038).The central corneal thickness(CCT),thinnest corneal thickness(tCT),and corneal volume(CV)values in groups I and II were significantly lower than those in group III(for CCT values,P=0.011 and P=0.009;for tCT values,P=0.010 and P=0.005;for CV values,P=0.043 and P=0.029).Conclusion:In WD patients with a KF-r,corneal transparency decreased in the peripheral posterior and mid stromal corneal layers;for these patients,corneal transparency may be impaired not only in the peripheral cornea but also in the paracentral cornea.