A multi-station integration system(MSIS)integrat-ing other multi-type stations provides a new way to realize an intensive development of resources and promote low-carbon en-ergy and its high-efficiency utilization.To ...A multi-station integration system(MSIS)integrat-ing other multi-type stations provides a new way to realize an intensive development of resources and promote low-carbon en-ergy and its high-efficiency utilization.To this end,a novel multi-station integration planning method and coordinated operation strategy model for the MSIS are established in a new business model.In this study,a new business model of the MSIS,with substations as the carrier,integrating distributed photovoltaic,energy storage,electric vehicle charging,data center,and 5G base stations is proposed.From the social environment,natural conditions,and complementary characteristics,a comprehensive index system is established to analyze expansion capability of substations and multi-station combination scheme.Scenario reduction is performed by extracting feature vectors and build-ing a comprehensive evaluation function to select the optimal combination scheme under a specific scenario.Moreover,for the combination scheme in a specific scenario,the optimal ca-pacity configuration and coordinated operation strategy chance-constrained programming model of the MSIS are established under different operating conditions.Finally,simulations are performed on a practical MSIS located in Wuxi,China,and simulation results demonstrate the rationality and effectiveness of the planning method and coordinated operation strategy model for the MSIS.展开更多
More and more attention has been paid to the high penetration of renewable energy in recent years.The randomness and intermittency of solar and wind energy make it an inevitable trend that renewables are coupled with ...More and more attention has been paid to the high penetration of renewable energy in recent years.The randomness and intermittency of solar and wind energy make it an inevitable trend that renewables are coupled with energy storage technologies.Pumped hydro storage(PHS)is the most widelyused storage form in the power grid but the capacity is limited by geographic conditions.The concentrated solar power(CSP)plant with a thermal energy storage(TES)system can realize easier grid connections and effective peak shaving.Therefore,this paper proposes a solar-wind-hydro hybrid power system with PHS-TES double energy storages,and investigates the optimal coordinated operational strategy and multi-objective sizing.The optimal sizing problem which considers the minimum levelized cost of energy(LCOE)and loss of power supply probability(LPSP)as objectives is solved by multi-objective particle swarm optimization.Moreover,the seasonal uncertainties of renewables are considered by applying a scenario-based analysis using Kmeans clustering.Finally,a case study reveals the effectiveness of the coordinated operational strategy and double energy storages from the perspectives of economy and reliability.The comparisons of optimal sizing results show that the PV-WindCSP-PHS system decreases the LCOE by 19.1%compared to a PV-Wind-CSP system under the same LPSP,and reduces the LPSP compared to PV-Wind-PHS systems with limited reservoir capacity,which indicates that the proposed system with double energy storages has better economy and reliability performance compared to single storage.展开更多
基金the Postgraduate Research&Practice Innovation Program of Jiangsu Province,China(KYCX22_0606)。
文摘A multi-station integration system(MSIS)integrat-ing other multi-type stations provides a new way to realize an intensive development of resources and promote low-carbon en-ergy and its high-efficiency utilization.To this end,a novel multi-station integration planning method and coordinated operation strategy model for the MSIS are established in a new business model.In this study,a new business model of the MSIS,with substations as the carrier,integrating distributed photovoltaic,energy storage,electric vehicle charging,data center,and 5G base stations is proposed.From the social environment,natural conditions,and complementary characteristics,a comprehensive index system is established to analyze expansion capability of substations and multi-station combination scheme.Scenario reduction is performed by extracting feature vectors and build-ing a comprehensive evaluation function to select the optimal combination scheme under a specific scenario.Moreover,for the combination scheme in a specific scenario,the optimal ca-pacity configuration and coordinated operation strategy chance-constrained programming model of the MSIS are established under different operating conditions.Finally,simulations are performed on a practical MSIS located in Wuxi,China,and simulation results demonstrate the rationality and effectiveness of the planning method and coordinated operation strategy model for the MSIS.
基金the National Key Research and Development Program of China 2018YFE0128500the Fundamental Research Funds for the Central Universities of China under Grant B210202069.
文摘More and more attention has been paid to the high penetration of renewable energy in recent years.The randomness and intermittency of solar and wind energy make it an inevitable trend that renewables are coupled with energy storage technologies.Pumped hydro storage(PHS)is the most widelyused storage form in the power grid but the capacity is limited by geographic conditions.The concentrated solar power(CSP)plant with a thermal energy storage(TES)system can realize easier grid connections and effective peak shaving.Therefore,this paper proposes a solar-wind-hydro hybrid power system with PHS-TES double energy storages,and investigates the optimal coordinated operational strategy and multi-objective sizing.The optimal sizing problem which considers the minimum levelized cost of energy(LCOE)and loss of power supply probability(LPSP)as objectives is solved by multi-objective particle swarm optimization.Moreover,the seasonal uncertainties of renewables are considered by applying a scenario-based analysis using Kmeans clustering.Finally,a case study reveals the effectiveness of the coordinated operational strategy and double energy storages from the perspectives of economy and reliability.The comparisons of optimal sizing results show that the PV-WindCSP-PHS system decreases the LCOE by 19.1%compared to a PV-Wind-CSP system under the same LPSP,and reduces the LPSP compared to PV-Wind-PHS systems with limited reservoir capacity,which indicates that the proposed system with double energy storages has better economy and reliability performance compared to single storage.