The radiation effects on several properties (reference voltage, digital output logic voltage, and supply current) of dual 8-bit analog-to-digital (A/D) converters (AD9058) under various biased conditions are inv...The radiation effects on several properties (reference voltage, digital output logic voltage, and supply current) of dual 8-bit analog-to-digital (A/D) converters (AD9058) under various biased conditions are investigated in this paper. Gamma ray and 10-MeV proton irradiation are selected for a detailed evaluation and comparison. Based on the measurement results induced by the gamma ray with various dose rates, the devices exhibit enhanced low dose rate sensitivity (ELDRS) under zero and working bias conditions. Meanwhile, it is obvious that the ELDRS is more severe under the working bias condition than under the zero bias condition. The degradation of AD9058 does not display obvious ELDRS during 10-MeV proton irradiation with the selected flux.展开更多
To change the undesirable present situation of recovering and using converter gas in steel plants in China, the basic approaches to improving the converter gas recovery rate were analyzed theoretically along with the ...To change the undesirable present situation of recovering and using converter gas in steel plants in China, the basic approaches to improving the converter gas recovery rate were analyzed theoretically along with the change curves of the converter gas component content, based on the converter gas recovery system of Baosteel No. 2 steel- making plant. The effects of converter device, raw material, air imbibed quantity, recovery restricted condition, and intensity of oxygen blowing on the converter gas recovery rate were studied. Among these, the effects of the air im bibed quantity, recovery restricted condition, and intensity of oxygen blowing are remarkable. Comprehensive measures were put forward for improving the converter gas recovery from the point of devices, etc. , and good results were achieved.展开更多
Tracking problem in spherical coordinates with range rate (Doppler) measurements, which would have errors correlated to the range measurement errors, is investigated in this paper. The converted Doppler measurements...Tracking problem in spherical coordinates with range rate (Doppler) measurements, which would have errors correlated to the range measurement errors, is investigated in this paper. The converted Doppler measurements, constructed by the product of the Doppler measurements and range measurements, are used to replace the original Doppler measurements. A de-noising method based on an unbiased Kalman filter (KF) is proposed to reduce the converted Doppler measurement errors before updating the target states for the constant velocity (CV) model. The states from the de-noising filter are then combined with the Cartesian states from the converted measurement Kalman filter (CMKF) to produce final state estimates. The nonlinearity of the de-noising filter states are handled by expanding them around the Cartesian states from the CMKF in a Taylor series up to the second order term. In the mean time, the correlation between the two filters caused by the common range measurements is handled by a mini- mum mean squared error (MMSE) estimation-based method. These result in a new tracking filter, CMDN-EKF2. Monte Carlo simulations demonstrate that the proposed tracking filter can provide efficient and robust performance with a modest computa- tional cost.展开更多
The relationship between the hardware requirement of digital down converters(DDCs)in ultra-low symbol rate receivers and the word length is studied.Through analyzing the impact of word length selection to the system...The relationship between the hardware requirement of digital down converters(DDCs)in ultra-low symbol rate receivers and the word length is studied.Through analyzing the impact of word length selection to the system performance,a modified scheme is presented to decline the resource consumption without too much degradation on the signal to noise ratio(SNR).Theoretical analysis and numerical results demonstrate that compared to the traditional design,the proposed scheme could save dozens of memory resources.The scheme also includes some selectable parameters to achieve desired performance in various circumstances.Different from previous work in DDCs that concentrates mostly on the structure design,this paper considers special applications such as ultra-low symbol rate receivers.展开更多
Objectives: To investigate the relationship between the use of angiotensin converting enzyme (ACE) inhibitor or angiotensin II receptor blocker (ARB) and hyperkalemia in patients diagnosed with sudden cardiac death. M...Objectives: To investigate the relationship between the use of angiotensin converting enzyme (ACE) inhibitor or angiotensin II receptor blocker (ARB) and hyperkalemia in patients diagnosed with sudden cardiac death. Methods: We examined oral ACE inhibitor or ARB use among cardiopulmonary arrest patients brought by ambulance to our emergency room during a 5-year period from January 2012 to December 2016. The cause of death was determined to be sudden cardiac death, despite temporary return of spontaneous circulation after starting cardiopulmonary resuscitation. Subjects were dichotomized into 2 groups, those taking and those not taking an ACE inhibitor or ARB. Variables determined retrospectively included serum potassium, estimated glomerular filtration rate as an index of kidney function and time from cardiopulmonary arrest to return of spontaneous circulation. The Mann-Whitney U-test was used to compare continuous data, and the chi-square test to compare categorical data between groups. The results are expressed as the median plus range. Statistical significance was assumed at p Results: Thirty-five patients met the inclusion criteria. The mean age was 77.1 years (range, 35 - 93 years), and there were 26 males and 9 females. Eleven subjects were ACE inhibitor or ARB users, and 24 were non-users. The serum potassium level was significantly higher in users than non-users (median, 6.2 mEq/L (range, 4.5 - 10.0) vs. 5.2 mEq/L (range, 3.6 - 8.3);p = 0.001). The estimated glomerular filtration rate was significantly lower in users than non-users (median, 25.1 mL/min/1.73 m2 (range, 4.6 - 60.3) vs. 46.9 mL/min/1.73 m2 (range, 19.8 - 97.1);p = 0.009). There was no significant difference in time from cardiopulmonary arrest to return of spontaneous circulation between the 2 groups (median, 24 minutes (range, 3 - 111) vs. 29 minutes (range, 10 - 54);p = 0.355). Conclusion: It is possible that hyperkalemia induced by ACE inhibitor or ARB use is a cause of sudden cardiac death, especially in patients with chronic kidney disease.展开更多
基于主动换相换流器(actively commutated converter,ACC)的高压直流输电(high voltage direct current,HVDC)技术具备构网运行能力且无换相失败风险,在大规模新能源外送领域具有良好的应用前景。调制策略是ACC换流站正常运行的前提,但...基于主动换相换流器(actively commutated converter,ACC)的高压直流输电(high voltage direct current,HVDC)技术具备构网运行能力且无换相失败风险,在大规模新能源外送领域具有良好的应用前景。调制策略是ACC换流站正常运行的前提,但现有高频、中频、基频3类调制方式在串联器件电压均衡、输出谐波特性、运行效率等方面各有优劣,不同场景及工况下的调制策略适配困难。针对上述问题,确立适应新能源送出的ACC-HVDC换流站调制策略性能指标;分别对5种典型调制策略的交流输出特性、直流电流利用率、运行损耗等指标进行量化对比,实现复杂场景多工况ACC调制策略的最优选择;最后,在MATLAB/Simulink中搭建ACC-HVDC电磁暂态仿真模型,对上述理论分析和算例进行验证。展开更多
基金supported by the National Natural Science Foundation of China (Grant No. 11205038)the China Postdoctoral Science Foundation (Grant No. 2012M510951)
文摘The radiation effects on several properties (reference voltage, digital output logic voltage, and supply current) of dual 8-bit analog-to-digital (A/D) converters (AD9058) under various biased conditions are investigated in this paper. Gamma ray and 10-MeV proton irradiation are selected for a detailed evaluation and comparison. Based on the measurement results induced by the gamma ray with various dose rates, the devices exhibit enhanced low dose rate sensitivity (ELDRS) under zero and working bias conditions. Meanwhile, it is obvious that the ELDRS is more severe under the working bias condition than under the zero bias condition. The degradation of AD9058 does not display obvious ELDRS during 10-MeV proton irradiation with the selected flux.
基金Item Sponsored by National Natural Science Foundation of China (50334020)
文摘To change the undesirable present situation of recovering and using converter gas in steel plants in China, the basic approaches to improving the converter gas recovery rate were analyzed theoretically along with the change curves of the converter gas component content, based on the converter gas recovery system of Baosteel No. 2 steel- making plant. The effects of converter device, raw material, air imbibed quantity, recovery restricted condition, and intensity of oxygen blowing on the converter gas recovery rate were studied. Among these, the effects of the air im bibed quantity, recovery restricted condition, and intensity of oxygen blowing are remarkable. Comprehensive measures were put forward for improving the converter gas recovery from the point of devices, etc. , and good results were achieved.
基金Fundamental Research Funds for the Central Universities (HIT.NSRIF.2010097)National Natural Science Foundation of China (61171188, 61201311)
文摘Tracking problem in spherical coordinates with range rate (Doppler) measurements, which would have errors correlated to the range measurement errors, is investigated in this paper. The converted Doppler measurements, constructed by the product of the Doppler measurements and range measurements, are used to replace the original Doppler measurements. A de-noising method based on an unbiased Kalman filter (KF) is proposed to reduce the converted Doppler measurement errors before updating the target states for the constant velocity (CV) model. The states from the de-noising filter are then combined with the Cartesian states from the converted measurement Kalman filter (CMKF) to produce final state estimates. The nonlinearity of the de-noising filter states are handled by expanding them around the Cartesian states from the CMKF in a Taylor series up to the second order term. In the mean time, the correlation between the two filters caused by the common range measurements is handled by a mini- mum mean squared error (MMSE) estimation-based method. These result in a new tracking filter, CMDN-EKF2. Monte Carlo simulations demonstrate that the proposed tracking filter can provide efficient and robust performance with a modest computa- tional cost.
基金Supported by the National Natural Science Foundation of China(60972018)
文摘The relationship between the hardware requirement of digital down converters(DDCs)in ultra-low symbol rate receivers and the word length is studied.Through analyzing the impact of word length selection to the system performance,a modified scheme is presented to decline the resource consumption without too much degradation on the signal to noise ratio(SNR).Theoretical analysis and numerical results demonstrate that compared to the traditional design,the proposed scheme could save dozens of memory resources.The scheme also includes some selectable parameters to achieve desired performance in various circumstances.Different from previous work in DDCs that concentrates mostly on the structure design,this paper considers special applications such as ultra-low symbol rate receivers.
文摘Objectives: To investigate the relationship between the use of angiotensin converting enzyme (ACE) inhibitor or angiotensin II receptor blocker (ARB) and hyperkalemia in patients diagnosed with sudden cardiac death. Methods: We examined oral ACE inhibitor or ARB use among cardiopulmonary arrest patients brought by ambulance to our emergency room during a 5-year period from January 2012 to December 2016. The cause of death was determined to be sudden cardiac death, despite temporary return of spontaneous circulation after starting cardiopulmonary resuscitation. Subjects were dichotomized into 2 groups, those taking and those not taking an ACE inhibitor or ARB. Variables determined retrospectively included serum potassium, estimated glomerular filtration rate as an index of kidney function and time from cardiopulmonary arrest to return of spontaneous circulation. The Mann-Whitney U-test was used to compare continuous data, and the chi-square test to compare categorical data between groups. The results are expressed as the median plus range. Statistical significance was assumed at p Results: Thirty-five patients met the inclusion criteria. The mean age was 77.1 years (range, 35 - 93 years), and there were 26 males and 9 females. Eleven subjects were ACE inhibitor or ARB users, and 24 were non-users. The serum potassium level was significantly higher in users than non-users (median, 6.2 mEq/L (range, 4.5 - 10.0) vs. 5.2 mEq/L (range, 3.6 - 8.3);p = 0.001). The estimated glomerular filtration rate was significantly lower in users than non-users (median, 25.1 mL/min/1.73 m2 (range, 4.6 - 60.3) vs. 46.9 mL/min/1.73 m2 (range, 19.8 - 97.1);p = 0.009). There was no significant difference in time from cardiopulmonary arrest to return of spontaneous circulation between the 2 groups (median, 24 minutes (range, 3 - 111) vs. 29 minutes (range, 10 - 54);p = 0.355). Conclusion: It is possible that hyperkalemia induced by ACE inhibitor or ARB use is a cause of sudden cardiac death, especially in patients with chronic kidney disease.
文摘基于主动换相换流器(actively commutated converter,ACC)的高压直流输电(high voltage direct current,HVDC)技术具备构网运行能力且无换相失败风险,在大规模新能源外送领域具有良好的应用前景。调制策略是ACC换流站正常运行的前提,但现有高频、中频、基频3类调制方式在串联器件电压均衡、输出谐波特性、运行效率等方面各有优劣,不同场景及工况下的调制策略适配困难。针对上述问题,确立适应新能源送出的ACC-HVDC换流站调制策略性能指标;分别对5种典型调制策略的交流输出特性、直流电流利用率、运行损耗等指标进行量化对比,实现复杂场景多工况ACC调制策略的最优选择;最后,在MATLAB/Simulink中搭建ACC-HVDC电磁暂态仿真模型,对上述理论分析和算例进行验证。