The new energy power generation is becoming increasingly important in the power system.Such as photovoltaic power generation has become a research hotspot,however,due to the characteristics of light radiation changes,...The new energy power generation is becoming increasingly important in the power system.Such as photovoltaic power generation has become a research hotspot,however,due to the characteristics of light radiation changes,photovoltaic power generation is unstable and random,resulting in a low utilization rate and directly affecting the stability of the power grid.To solve this problem,this paper proposes a coordinated control strategy for a newenergy power generation system with a hybrid energy storage unit based on the lithium iron phosphate-supercapacitor hybrid energy storage unit.Firstly,the variational mode decomposition algorithm is used to separate the high and low frequencies of the power signal,which is conducive to the rapid and accurate suppression of the power fluctuation of the energy storage system.Secondly,the fuzzy control algorithm is introduced to balance the power between energy storage.In this paper,the actual data is used for simulation,and the simulation results show that the strategy realizes the effective suppression of the bus voltage fluctuation and the accurate control of the internal state of the energy storage unit,effectively avoiding problems such as overshoot and over-discharge,and can significantly improve the stability of the photovoltaic power generation systemand the stability of the Direct Current bus.It is of great significance to promote the development of collaborative control technology for photovoltaic hybrid energy storage units.展开更多
Large-scale new energy grid connection leads to the weakening of the system frequency regulation capability,and the system frequency stability is facing unprecedented challenges.In order to solve rapid frequency fluct...Large-scale new energy grid connection leads to the weakening of the system frequency regulation capability,and the system frequency stability is facing unprecedented challenges.In order to solve rapid frequency fluctuation caused by new energy units,this paper proposes a new energy power system frequency regulation strategy with multiple units including the doubly-fed pumped storage unit(DFPSU).Firstly,based on the model predictive control(MPC)theory,the state space equations are established by considering the operating characteristics of the units and the dynamic behavior of the system;secondly,the proportional-differential control link is introduced to minimize the frequency deviation to further optimize the frequency modulation(FM)output of the DFPSU and inhibit the rapid fluctuation of the frequency;lastly,it is verified on theMatlab/Simulink simulation platform,and the results show that the model predictive control with proportional-differential control link can further release the FM potential of the DFPSU,increase the depth of its FM,effectively reduce the frequency deviation of the system and its rate of change,realize the optimization of the active output of the DFPSU and that of other units,and improve the frequency response capability of the system.展开更多
Electric tractors(ETs)with mounted implements form operating units.There are significant differences in parameters such as shape,firmness,and moisture content of the soil in contact with the tractor and implements whe...Electric tractors(ETs)with mounted implements form operating units.There are significant differences in parameters such as shape,firmness,and moisture content of the soil in contact with the tractor and implements when working in complex terrains such as field stubble,waterlogged silt,and loose/firm terrain.These differentiated dynamics prevent cooperation between ETs and operating implements under independent control,resulting in poor quality operations and low energy efficiency.We propose a control mechanism for ETs and implements to achieve full life cycle management of collaborative control tasks,instantaneous intertask interaction,and a multitask synchronization mechanism.To address the internal redundant communication problems caused by traditional distributed microcontrol units,we break through the underlying technology of unit data processing and interaction and develop an integrated high-performance controller structure with high processing capacity and high-and low-speed communication interfaces.On the basis of hierarchical stepwise control theory,a hierarchical real-time operating system is designed.This system realizes a preemptive kernel response of computational tasks and competitive-collaborative synchronization among tasks;overcomes the low-latency response of collaborative control tasks,instantaneous information interaction,and multitask synchronization problems;and provides system-level support for deep collaborative operation control of units.To demonstrate and validate the proposed collaborative control mechanism,a plowing collaborative operation management strategy is designed and deployed.The experimental results show that the communication delay of collaborative tasks is as low as 83μs,the solution time of complex collaborative equations is as low as 46 ms,the mechanical efficiency of the ET is increased by 9.07%,the efficiency of the drive motor is increased by 9.72%,the stability of the operation speed is increased by 106.25%,and the stability of the plowing depth reaches 94.98%.Our work meets the hardware and software requirements for realizing complex collaborative control of ET units and improves the operational quality and operational energy efficiency in real vehicle demonstrations.展开更多
BACKGROUND Prolonged immobility during intensive care unit(ICU)admission has been a cause of muscle atrophy and worsening functional outcomes with longer recovery times.Prior research has demonstrated that mobilizatio...BACKGROUND Prolonged immobility during intensive care unit(ICU)admission has been a cause of muscle atrophy and worsening functional outcomes with longer recovery times.Prior research has demonstrated that mobilization within a week of ICU admission potentially benefits physical function in critically ill patients.AIM To evaluate the effects of initiating mobilization within 72 hours of ICU admission in critically ill patients through an updated systematic review and meta-analysis.METHODS A systematic search was performed through MEDLINE,Scopus,and Cochrane Library from inception until September 2024 for randomized controlled trials(RCTs)comparing early mobilization(EM)with usual or conventional care in critically ill adult patients.Primary outcomes included length of ICU(days)and ventilation duration(days).Secondary outcomes included muscle strength,functional status,adverse events,all-cause mortality,and quality of life(QOL).A random effects meta-analysis was performed for pooled effect estimates and to derive risk ratios(RR)and corresponding 95%confidence intervals(CI).RESULTS Out of 3487 results,16 RCTs were included with a population of 2385 patients(1195 receiving EM and 1190 with usual care.)A significant reduction in the length of ICU stays[mean difference(MD)=-1.02,95%CI:-1.96 to-0.09;P=0.03;I2=60%]and ventilation duration(MD=-1.07,95%CI:-1.91 to-0.23,P=0.01;I2=57%)was observed in the EM group compared to usual care.EM significantly improved muscle strength[standard MD(SMD)=0.47,95%CI:0.18-0.75,P=0.001;I2=79%]and functional status(SMD=0.70,95%CI:0.40-1.00,P<0.00001;I2=81%)in ICU patients.No statistically significant difference was observed in adverse events(RR=1.72,95%CI:1.01-2.94,P=0.05;I2=31%),all-cause mortality(RR=1.10,95%CI:0.79-1.53,P=0.57;I2=30%),and QOL(SMD=0.04,95%CI:-0.07-0.15,P=0.50;I2=9%)between the two groups.CONCLUSION Initiating mobilization within 72 hours of ICU admission is associated with improved functional outcomes and reduced ICU length of stay and ventilation duration.These findings indicate that EM may be a safe option for ICU patients,contributing to lower recovery times and healthcare costs.Further extensive research is required to validate the long-term effects on survival and QOL.展开更多
In high-renewable-energy power systems,the demand for fast-responding capabilities is growing.To address the limitations of conventional closed-loop frequency control,where the integral coefficient cannot dynamically ...In high-renewable-energy power systems,the demand for fast-responding capabilities is growing.To address the limitations of conventional closed-loop frequency control,where the integral coefficient cannot dynamically adjust the frequency regulation command based on the state of charge(SoC)of energy storage units,this paper proposes a secondary frequency regulation control strategy based on variable integral coefficients for multiple energy storage units.First,a power-uniform controller is designed to ensure that thermal power units gradually take on more regulation power during the frequency regulation process.Next,a control framework based on variable integral coefficients is proposed within the secondary frequency regulation model,along with an objective function that simultaneously considers both Automatic Generation Control(AGC)command tracking performance and SoC recovery requirements of energy storage units.Finally,a gradient descent optimization method is used to dynamically adjust the gain of the energy storage integral controller,allowingmultiple energy storage units to respond in real-time to AGC instructions and SoC variations.Simulation results confirmthe effectiveness of the proposedmethod.Compared to traditional strategies,the proposed approach takes into account the SoCdiscrepancies amongmultiple energy storage units and the duration of system net power imbalances.It successfully implements secondary frequency regulation while achieving dynamic power allocation among the units.展开更多
Spillover of trypanosomiasis parasites from wildlife to domestic livestock and humans remains a major challenge world over.With the disease targeted for elimination by 2030,assessing the impact of control strategies i...Spillover of trypanosomiasis parasites from wildlife to domestic livestock and humans remains a major challenge world over.With the disease targeted for elimination by 2030,assessing the impact of control strategies in communities where there are human-cattle-wildlife interactions is therefore essential.A compartmental framework incorporating tsetse flies,humans,cattle,wildlife and various disease control strategies is developed and analyzed.The reproduction is derived and its sensitivity to different model parameters is investigated.Meanwhile,the optimal control theory is used to identify a combination of control strategies capable of minimizing the infected human and cattle population over time at minimal costs of implementation.The results indicates that tsetse fly mortality rate is strongly and negatively correlated to the reproduction number.It is also established that tsetse fly feeding rate in strongly and positively correlated to the reproduction number.Simulation results indicates that time dependent control strategies can significantly reduce the infections.Overall,the study shows that screening and treatment of humans may not lead to disease elimination.Combining this strategy with other strategies such as screening and treatment of cattle and vector control strategies will result in maximum reduction of tsetse fly population and disease elimination.展开更多
Digital twin can simulate and monitor the state and behavior of physical entities in the real world,helping enterprises to better understand and manage real-world physical systems,improve production efficiency,reduce ...Digital twin can simulate and monitor the state and behavior of physical entities in the real world,helping enterprises to better understand and manage real-world physical systems,improve production efficiency,reduce costs,and improve safety and reliability.In this paper,we use GTS motion control card and Unity engine to build a digital twin system,and control a virtual industrial automation handling platform including two screw servo axes and multiple sensors through the physical GTS motion control card.The control card program controls the motion of the virtual model through transmission control protocol(TCP)communication,and the virtual model system feeds back the signal to the control card program to achieve the virtual and real synchronous digital twin effect.The digital twin system uses Unity engine to create a highly realistic virtual environment,and can run on multi-platform terminals.展开更多
This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper cons...This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper constructs an internal model to learn the information of the states and input of the grid-connected inverter under steady state.Second,by utilizing the internal model principle,the paper turns the tracking control problem into the robust stabilization control problem based on some appropriate coordinate transformations.Then,The paper designs a dynamics state feedback control law to deal with this robust stabilization problem,and thus the solution of the robust current tracking control problem of three-phase grid-connected inverters can be obtained.This control method can ensure the asymptotic stability of the closedloop system.Finally,the paper illustrates the effectiveness of the proposed control approach through several groups of simulations,and compares it with the feedforward control method to verify the robustness of the proposed control method to uncertain parameters.展开更多
Aiming to solve the steering instability and hysteresis of agricultural robots in the process of movement,a fusion PID control method of particle swarm optimization(PSO)and genetic algorithm(GA)was proposed.The fusion...Aiming to solve the steering instability and hysteresis of agricultural robots in the process of movement,a fusion PID control method of particle swarm optimization(PSO)and genetic algorithm(GA)was proposed.The fusion algorithm took advantage of the fast optimization ability of PSO to optimize the population screening link of GA.The Simulink simulation results showed that the convergence of the fitness function of the fusion algorithm was accelerated,the system response adjustment time was reduced,and the overshoot was almost zero.Then the algorithm was applied to the steering test of agricultural robot in various scenes.After modeling the steering system of agricultural robot,the steering test results in the unloaded suspended state showed that the PID control based on fusion algorithm reduced the rise time,response adjustment time and overshoot of the system,and improved the response speed and stability of the system,compared with the artificial trial and error PID control and the PID control based on GA.The actual road steering test results showed that the PID control response rise time based on the fusion algorithm was the shortest,about 4.43 s.When the target pulse number was set to 100,the actual mean value in the steady-state regulation stage was about 102.9,which was the closest to the target value among the three control methods,and the overshoot was reduced at the same time.The steering test results under various scene states showed that the PID control based on the proposed fusion algorithm had good anti-interference ability,it can adapt to the changes of environment and load and improve the performance of the control system.It was effective in the steering control of agricultural robot.This method can provide a reference for the precise steering control of other robots.展开更多
In this paper,we consider the maximal positive definite solution of the nonlinear matrix equation.By using the idea of Algorithm 2.1 in ZHANG(2013),a new inversion-free method with a stepsize parameter is proposed to ...In this paper,we consider the maximal positive definite solution of the nonlinear matrix equation.By using the idea of Algorithm 2.1 in ZHANG(2013),a new inversion-free method with a stepsize parameter is proposed to obtain the maximal positive definite solution of nonlinear matrix equation X+A^(*)X|^(-α)A=Q with the case 0<α≤1.Based on this method,a new iterative algorithm is developed,and its convergence proof is given.Finally,two numerical examples are provided to show the effectiveness of the proposed method.展开更多
As an important resource in data link,time slots should be strategically allocated to enhance transmission efficiency and resist eavesdropping,especially considering the tremendous increase in the number of nodes and ...As an important resource in data link,time slots should be strategically allocated to enhance transmission efficiency and resist eavesdropping,especially considering the tremendous increase in the number of nodes and diverse communication needs.It is crucial to design control sequences with robust randomness and conflict-freeness to properly address differentiated access control in data link.In this paper,we propose a hierarchical access control scheme based on control sequences to achieve high utilization of time slots and differentiated access control.A theoretical bound of the hierarchical control sequence set is derived to characterize the constraints on the parameters of the sequence set.Moreover,two classes of optimal hierarchical control sequence sets satisfying the theoretical bound are constructed,both of which enable the scheme to achieve maximum utilization of time slots.Compared with the fixed time slot allocation scheme,our scheme reduces the symbol error rate by up to 9%,which indicates a significant improvement in anti-interference and eavesdropping capabilities.展开更多
In this paper,we define for the trace operator,the solution of certain models of vibrating plates standards with initial data in a strategic region spaces of weak regularities.Indeed,we know that the notion of regiona...In this paper,we define for the trace operator,the solution of certain models of vibrating plates standards with initial data in a strategic region spaces of weak regularities.Indeed,we know that the notion of regional controllability is more adapted to systems described by dynamic systems.Regional controllability results in a strategic area were established for vibrating plates by the Hilbertian Uniqueness Method.展开更多
Molten salt reactors,being the only reactor type among Generation Ⅳ advanced nuclear reactors that utilize liquid fuels,offer inherent safety,high-temperature,and low-pressure operation,as well as the capability for ...Molten salt reactors,being the only reactor type among Generation Ⅳ advanced nuclear reactors that utilize liquid fuels,offer inherent safety,high-temperature,and low-pressure operation,as well as the capability for online fuel reprocessing.However,the fuel-salt flow results in the decay of delayed neutron precursors(DNPs)outside the core,causing fluctuations in the effective delayed neutron fraction and consequently impacting the reactor reactivity.Particularly in accident scenarios—such as a combined pump shutdown and the inability to rapidly scram the reactor—the sole reliance on negative temperature feedback may cause a significant increase in core temperature,posing a threat to reactor safety.To address these problems,this paper introduces an innovative design for a passive fluid-driven suspended control rod(SCR)to dynamically compensate for reactivity fluctuations caused by DNPs flowing with the fuel.The control rod operates passively by leveraging the combined effects of gravity,buoyancy,and fluid dynamic forces,thereby eliminating the need for an external drive mechanism and enabling direct integration within the active region of the core.Using a 150 MWt thorium-based molten salt reactor as the reference design,we develop a mathematical model to systematically analyze the effects of key parameters—including the geometric dimensions and density of the SCR—on its performance.We examine its motion characteristics under different core flow conditions and assess its feasibility for the dynamic compensation of reactivity changes caused by fuel flow.The results of this study demonstrate that the SCR can effectively counteract reactivity fluctuations induced by fuel flow within molten salt reactors.A sensitivity analysis reveals that the SCR’s average density exerts a profound impact on its start-up flow threshold,channel flow rate,resistance to fuel density fluctuations,and response characteristics.This underscores the critical need to optimize this parameter.Moreover,by judiciously selecting the SCR’s length,number of deployed units,and the placement we can achieve the necessary reactivity control while maintaining a favorable balance between neutron economy and heat transfer performance.Ultimately,this paper provides an innovative solution for the passive reactivity control in molten salt reactors,offering significant potential for practical engineering applications.展开更多
Apparel exports China:The decline in exports widened from January to September(-2.4%,compared to-0.2%in January-June).Exports to the EU increased(+5.9%),though the growth rate moderated.Exports to the US saw a larger ...Apparel exports China:The decline in exports widened from January to September(-2.4%,compared to-0.2%in January-June).Exports to the EU increased(+5.9%),though the growth rate moderated.Exports to the US saw a larger contraction(January-June:-1.6%,January-September:-8.2%).While exports to ASEAN countries still fell by over 10%(-17.7%),shipments to the Philippines(+6.9%),Indonesia(+19.0%),and Cambodia(+64.9%)demonstrated stronger growth performance within the year.Regarding tariffs,on October 30,China and the US agreed to lower the rates on goods subject to additional duties(effectively reducing the average tariff rate on Chinese imports to the US from about 57%to approximately 47%,though this remains significantly higher than the 19.5%overall average rate applied to other countries).展开更多
As a public basic course and the core general course of undergraduate education,moral education(ME)in College English is imperative.It is necessary to design specific teaching programs flexibly and creatively on the b...As a public basic course and the core general course of undergraduate education,moral education(ME)in College English is imperative.It is necessary to design specific teaching programs flexibly and creatively on the basis of fully understanding the ideas,objectives and tasks,basic principles and implementation methods of ME.This paper tries integrating literature reading into unit topic teaching as a new approach to ME in College English.The specific pathways of integration include:expansion of literary reading content,diversified teaching of literary reading,diversified media of literary reading,and diversified assessment system of literary quality.The integration of literature reading and unit topic teaching is conducive to the realization of the teaching goal of cultivating students’language ability,humanistic quality,and correct values.展开更多
Conventional multilevel inverters often suffer from high harmonic distortion and increased design complexity due to the need for numerous power semiconductor components,particularly at elevated voltage levels.Addressi...Conventional multilevel inverters often suffer from high harmonic distortion and increased design complexity due to the need for numerous power semiconductor components,particularly at elevated voltage levels.Addressing these shortcomings,thiswork presents a robust 15-level PackedUCell(PUC)inverter topology designed for renewable energy and grid-connected applications.The proposed systemintegrates a sensor less proportional-resonant(PR)controller with an advanced carrier-based pulse width modulation scheme.This approach efficiently balances capacitor voltage,minimizes steady-state error,and strongly suppresses both zero and third-order harmonics resulting in reduced total harmonic distortion and enhanced voltage regulation.Additionally,a novel switching algorithm simplifies the design and implementation,further lowering voltage stress across switches.Extensive simulation results validate the performance under various resistive and resistive-inductive load conditions,demonstrating compliance with IEEE-519 THD standards and robust operation under dynamic changes.The proposed sensorless PR-controlled 15-PUC inverter thus offers a compelling,cost-effective solution for efficient power conversion in next-generation renewable energy systems.展开更多
To address the issue of instability or even imbalance in the orientation and attitude control of quadrotor unmanned aerial vehicles(QUAVs)under random disturbances,this paper proposes a distributed antidisturbance dat...To address the issue of instability or even imbalance in the orientation and attitude control of quadrotor unmanned aerial vehicles(QUAVs)under random disturbances,this paper proposes a distributed antidisturbance data-driven event-triggered fusion control method,which achieves efficient fault diagnosis while suppressing random disturbances and mitigating communication conflicts within the QUAV swarm.First,the impact of random disturbances on the UAV swarm is analyzed,and a model for orientation and attitude control of QUAVs under stochastic perturbations is established,with the disturbance gain threshold determined.Second,a fault diagnosis system based on a high-gain observer is designed,constructing a fault gain criterion by integrating orientation and attitude information from QUAVs.Subsequently,a model-free dynamic linearization-based data modeling(MFDLDM)framework is developed using model-free adaptive control,which efficiently fits the nonlinear control model of the QUAV swarm while reducing temporal constraints on control data.On this basis,this paper constructs a distributed data-driven event-triggered controller based on the staggered communication mechanism,which consists of an equivalent QUAV controller and an event-triggered controller,and is able to reduce the communication conflicts while suppressing the influence of random interference.Finally,by incorporating random disturbances into the controller,comparative experiments and physical validations are conducted on the QUAV platforms,fully demonstrating the strong adaptability and robustness of the proposed distributed event-triggered fault-tolerant control system.展开更多
AIM:To investigate the effects of binocular fusional C-optotypes(positive/negative)and 2D planar C-optotypes on the amplitude and stability of transient accommodation(TAC)in adults,and to provide a basis for non-conta...AIM:To investigate the effects of binocular fusional C-optotypes(positive/negative)and 2D planar C-optotypes on the amplitude and stability of transient accommodation(TAC)in adults,and to provide a basis for non-contact myopia intervention.METHODS:This was a self-controlled study.Using redblue 3D technology,four experimental stages were set up:Test A[fixating on the 1 m negative fusional C-optotypes,8△base-in(BI)],Test B(fixating on the 5 m planar C-optotypes),Test C(fixating on the 1 m planar C-optotypes),and Test D[fixating on the 1 m positive fusional C-optotypes,20△base-out(BO)].A WAM-5500 open-field autorefractor was used to measure TAC and accommodative microfluctuations[evaluated via interquartile range(IQR)and median-based coefficient of variation(CVmed)].Additionally,the convergence accommodation to convergence(CA/C)ratio was calculated,and a visual fatigue questionnaire was administered to assess participants’subjective visual comfort.RESULTS:A total of 21 subjects(7 males,14 females;aged 23-41y)with normal binocular visual function were enrolled.The results showed that the TAC increased gradually across the four stages,and these values were Test A(-0.35±0.26 D)<Test B(-0.46±0.24 D)<Test C(-0.77±0.32 D)<Test D(-1.38±0.31 D).There were significant overall differences(F=56.136,P<0.001).Compared with Test C,Test A reduced TAC by 0.42 D(P<0.05),while Test D increased it by 0.61 D(P<0.001).There was no significant intergroup difference in accommodative fluctuation amplitude(all P>0.05),but the fluctuation stability of Test D showed a significant difference between the first 20s and the second 20s(P=0.017).The CA/C ratio was significantly higher in Test D(0.05±0.02 D/△)than in Test A(0.03±0.02 D/△,P=0.007),indicating stronger accommodation-convergence linkage during positive fusional fixation.The visual fatigue scores of all stages were low(median 0-1),with Test D slightly higher than Test B and Test C(P<0.05).No linear correlation was found between TAC and age(all r<0.1,P>0.05).CONCLUSION:Negative fusional C-optotypes induce ciliary muscle relaxation to reduce TAC,while positive fusional C-optotypes enhance accommodation-convergence coordination to increase TAC.The red-blue 3D-based noncontact training mode exhibits good safety(median visual fatigue scores:0-1 across all tests)and provides a novel dual-directional(relaxation-activation)strategy for myopia prevention and control.展开更多
Understanding water chemistry in karst regions is crucial for improving global water resource management and deepening our knowledge of the biogeochemical cycles shaping these sensitive environments.Despite advance-me...Understanding water chemistry in karst regions is crucial for improving global water resource management and deepening our knowledge of the biogeochemical cycles shaping these sensitive environments.Despite advance-ments in karst hydrology,significant gaps remain in long-term trends,underlying processes,and quantitative effects of environmental changes.This is especially true in areas like the Wujiang River(WJ)in China,where human activities such as reservoir construction and land use/cover changes have accelerated hydrochemical changes.We combined recent and historical monitoring data to provide a detailed analysis of the spatial and temporal characteristics,evolution,and controlling factors of major ions in WJ.These findings are important for local water management and contribute to global efforts to manage similar karst systems facing human-induced pressures.Our research shows clear seasonal differences in solute concentrations,with higher levels during the dry season.WJ’s water is rich in calcium,with Ca-HCO_(3) ion pairs being the most common.Reservoir monitor-ing stations show much higher levels of NO_(3)^(−)and SO_(4)^(2−)compared to river-type stations,likely due to longer hydraulic retention time and increased acid deposition.The study confirms the significant role of pH and water temperature in rock weathering processes.Land use/cover changes were identified as the primary drivers of solute variations(46.37%),followed by lithology(13.92%)and temperature(8.35%).Over the past two decades,in-tense carbonate weathering has been observed,especially during wet seasons.Among karstic provinces,Guizhou Province stands out with the highest ion concentrations,indicative of its extensive karst coverage and heightened weathering processes.展开更多
基金supported by the State Grid Corporation of China Science and Technology Project,grant number 52270723000900K.
文摘The new energy power generation is becoming increasingly important in the power system.Such as photovoltaic power generation has become a research hotspot,however,due to the characteristics of light radiation changes,photovoltaic power generation is unstable and random,resulting in a low utilization rate and directly affecting the stability of the power grid.To solve this problem,this paper proposes a coordinated control strategy for a newenergy power generation system with a hybrid energy storage unit based on the lithium iron phosphate-supercapacitor hybrid energy storage unit.Firstly,the variational mode decomposition algorithm is used to separate the high and low frequencies of the power signal,which is conducive to the rapid and accurate suppression of the power fluctuation of the energy storage system.Secondly,the fuzzy control algorithm is introduced to balance the power between energy storage.In this paper,the actual data is used for simulation,and the simulation results show that the strategy realizes the effective suppression of the bus voltage fluctuation and the accurate control of the internal state of the energy storage unit,effectively avoiding problems such as overshoot and over-discharge,and can significantly improve the stability of the photovoltaic power generation systemand the stability of the Direct Current bus.It is of great significance to promote the development of collaborative control technology for photovoltaic hybrid energy storage units.
基金supported by the National Natural Science Foundation of China(Project No.52377082)the Scientific Research Program of Jilin Provincial Department of Education(Project No.JJKH20230123KJ).
文摘Large-scale new energy grid connection leads to the weakening of the system frequency regulation capability,and the system frequency stability is facing unprecedented challenges.In order to solve rapid frequency fluctuation caused by new energy units,this paper proposes a new energy power system frequency regulation strategy with multiple units including the doubly-fed pumped storage unit(DFPSU).Firstly,based on the model predictive control(MPC)theory,the state space equations are established by considering the operating characteristics of the units and the dynamic behavior of the system;secondly,the proportional-differential control link is introduced to minimize the frequency deviation to further optimize the frequency modulation(FM)output of the DFPSU and inhibit the rapid fluctuation of the frequency;lastly,it is verified on theMatlab/Simulink simulation platform,and the results show that the model predictive control with proportional-differential control link can further release the FM potential of the DFPSU,increase the depth of its FM,effectively reduce the frequency deviation of the system and its rate of change,realize the optimization of the active output of the DFPSU and that of other units,and improve the frequency response capability of the system.
基金supported by the National Key Research and Development Plan of China(2022YFD2001202)the National Natural Science Foundation of China(32301719 and 52272444)the 2115 Talent Development Program of China Agricultural University.
文摘Electric tractors(ETs)with mounted implements form operating units.There are significant differences in parameters such as shape,firmness,and moisture content of the soil in contact with the tractor and implements when working in complex terrains such as field stubble,waterlogged silt,and loose/firm terrain.These differentiated dynamics prevent cooperation between ETs and operating implements under independent control,resulting in poor quality operations and low energy efficiency.We propose a control mechanism for ETs and implements to achieve full life cycle management of collaborative control tasks,instantaneous intertask interaction,and a multitask synchronization mechanism.To address the internal redundant communication problems caused by traditional distributed microcontrol units,we break through the underlying technology of unit data processing and interaction and develop an integrated high-performance controller structure with high processing capacity and high-and low-speed communication interfaces.On the basis of hierarchical stepwise control theory,a hierarchical real-time operating system is designed.This system realizes a preemptive kernel response of computational tasks and competitive-collaborative synchronization among tasks;overcomes the low-latency response of collaborative control tasks,instantaneous information interaction,and multitask synchronization problems;and provides system-level support for deep collaborative operation control of units.To demonstrate and validate the proposed collaborative control mechanism,a plowing collaborative operation management strategy is designed and deployed.The experimental results show that the communication delay of collaborative tasks is as low as 83μs,the solution time of complex collaborative equations is as low as 46 ms,the mechanical efficiency of the ET is increased by 9.07%,the efficiency of the drive motor is increased by 9.72%,the stability of the operation speed is increased by 106.25%,and the stability of the plowing depth reaches 94.98%.Our work meets the hardware and software requirements for realizing complex collaborative control of ET units and improves the operational quality and operational energy efficiency in real vehicle demonstrations.
文摘BACKGROUND Prolonged immobility during intensive care unit(ICU)admission has been a cause of muscle atrophy and worsening functional outcomes with longer recovery times.Prior research has demonstrated that mobilization within a week of ICU admission potentially benefits physical function in critically ill patients.AIM To evaluate the effects of initiating mobilization within 72 hours of ICU admission in critically ill patients through an updated systematic review and meta-analysis.METHODS A systematic search was performed through MEDLINE,Scopus,and Cochrane Library from inception until September 2024 for randomized controlled trials(RCTs)comparing early mobilization(EM)with usual or conventional care in critically ill adult patients.Primary outcomes included length of ICU(days)and ventilation duration(days).Secondary outcomes included muscle strength,functional status,adverse events,all-cause mortality,and quality of life(QOL).A random effects meta-analysis was performed for pooled effect estimates and to derive risk ratios(RR)and corresponding 95%confidence intervals(CI).RESULTS Out of 3487 results,16 RCTs were included with a population of 2385 patients(1195 receiving EM and 1190 with usual care.)A significant reduction in the length of ICU stays[mean difference(MD)=-1.02,95%CI:-1.96 to-0.09;P=0.03;I2=60%]and ventilation duration(MD=-1.07,95%CI:-1.91 to-0.23,P=0.01;I2=57%)was observed in the EM group compared to usual care.EM significantly improved muscle strength[standard MD(SMD)=0.47,95%CI:0.18-0.75,P=0.001;I2=79%]and functional status(SMD=0.70,95%CI:0.40-1.00,P<0.00001;I2=81%)in ICU patients.No statistically significant difference was observed in adverse events(RR=1.72,95%CI:1.01-2.94,P=0.05;I2=31%),all-cause mortality(RR=1.10,95%CI:0.79-1.53,P=0.57;I2=30%),and QOL(SMD=0.04,95%CI:-0.07-0.15,P=0.50;I2=9%)between the two groups.CONCLUSION Initiating mobilization within 72 hours of ICU admission is associated with improved functional outcomes and reduced ICU length of stay and ventilation duration.These findings indicate that EM may be a safe option for ICU patients,contributing to lower recovery times and healthcare costs.Further extensive research is required to validate the long-term effects on survival and QOL.
文摘In high-renewable-energy power systems,the demand for fast-responding capabilities is growing.To address the limitations of conventional closed-loop frequency control,where the integral coefficient cannot dynamically adjust the frequency regulation command based on the state of charge(SoC)of energy storage units,this paper proposes a secondary frequency regulation control strategy based on variable integral coefficients for multiple energy storage units.First,a power-uniform controller is designed to ensure that thermal power units gradually take on more regulation power during the frequency regulation process.Next,a control framework based on variable integral coefficients is proposed within the secondary frequency regulation model,along with an objective function that simultaneously considers both Automatic Generation Control(AGC)command tracking performance and SoC recovery requirements of energy storage units.Finally,a gradient descent optimization method is used to dynamically adjust the gain of the energy storage integral controller,allowingmultiple energy storage units to respond in real-time to AGC instructions and SoC variations.Simulation results confirmthe effectiveness of the proposedmethod.Compared to traditional strategies,the proposed approach takes into account the SoCdiscrepancies amongmultiple energy storage units and the duration of system net power imbalances.It successfully implements secondary frequency regulation while achieving dynamic power allocation among the units.
文摘Spillover of trypanosomiasis parasites from wildlife to domestic livestock and humans remains a major challenge world over.With the disease targeted for elimination by 2030,assessing the impact of control strategies in communities where there are human-cattle-wildlife interactions is therefore essential.A compartmental framework incorporating tsetse flies,humans,cattle,wildlife and various disease control strategies is developed and analyzed.The reproduction is derived and its sensitivity to different model parameters is investigated.Meanwhile,the optimal control theory is used to identify a combination of control strategies capable of minimizing the infected human and cattle population over time at minimal costs of implementation.The results indicates that tsetse fly mortality rate is strongly and negatively correlated to the reproduction number.It is also established that tsetse fly feeding rate in strongly and positively correlated to the reproduction number.Simulation results indicates that time dependent control strategies can significantly reduce the infections.Overall,the study shows that screening and treatment of humans may not lead to disease elimination.Combining this strategy with other strategies such as screening and treatment of cattle and vector control strategies will result in maximum reduction of tsetse fly population and disease elimination.
基金Research Startup Project of Shenzhen Polytechnic University“Research and Development of High-Speed and High-Resolution 2D/3D Combined Vision Sensor”(Project No.6022312003K).
文摘Digital twin can simulate and monitor the state and behavior of physical entities in the real world,helping enterprises to better understand and manage real-world physical systems,improve production efficiency,reduce costs,and improve safety and reliability.In this paper,we use GTS motion control card and Unity engine to build a digital twin system,and control a virtual industrial automation handling platform including two screw servo axes and multiple sensors through the physical GTS motion control card.The control card program controls the motion of the virtual model through transmission control protocol(TCP)communication,and the virtual model system feeds back the signal to the control card program to achieve the virtual and real synchronous digital twin effect.The digital twin system uses Unity engine to create a highly realistic virtual environment,and can run on multi-platform terminals.
基金Supported by the Fundamental Research Funds for the Central Universities(2024ZYGXZR047)the National Natural Science Foundation of China(62373156)the Guangdong Basic and Applied Basic Research Foundation(2024A1515011736)。
文摘This article investigates the robust current tracking control problem of three-phase grid-connected inverters with LCL filter under external disturbance by a dynamic state feedback control method.First,this paper constructs an internal model to learn the information of the states and input of the grid-connected inverter under steady state.Second,by utilizing the internal model principle,the paper turns the tracking control problem into the robust stabilization control problem based on some appropriate coordinate transformations.Then,The paper designs a dynamics state feedback control law to deal with this robust stabilization problem,and thus the solution of the robust current tracking control problem of three-phase grid-connected inverters can be obtained.This control method can ensure the asymptotic stability of the closedloop system.Finally,the paper illustrates the effectiveness of the proposed control approach through several groups of simulations,and compares it with the feedforward control method to verify the robustness of the proposed control method to uncertain parameters.
文摘Aiming to solve the steering instability and hysteresis of agricultural robots in the process of movement,a fusion PID control method of particle swarm optimization(PSO)and genetic algorithm(GA)was proposed.The fusion algorithm took advantage of the fast optimization ability of PSO to optimize the population screening link of GA.The Simulink simulation results showed that the convergence of the fitness function of the fusion algorithm was accelerated,the system response adjustment time was reduced,and the overshoot was almost zero.Then the algorithm was applied to the steering test of agricultural robot in various scenes.After modeling the steering system of agricultural robot,the steering test results in the unloaded suspended state showed that the PID control based on fusion algorithm reduced the rise time,response adjustment time and overshoot of the system,and improved the response speed and stability of the system,compared with the artificial trial and error PID control and the PID control based on GA.The actual road steering test results showed that the PID control response rise time based on the fusion algorithm was the shortest,about 4.43 s.When the target pulse number was set to 100,the actual mean value in the steady-state regulation stage was about 102.9,which was the closest to the target value among the three control methods,and the overshoot was reduced at the same time.The steering test results under various scene states showed that the PID control based on the proposed fusion algorithm had good anti-interference ability,it can adapt to the changes of environment and load and improve the performance of the control system.It was effective in the steering control of agricultural robot.This method can provide a reference for the precise steering control of other robots.
基金Supported in part by Natural Science Foundation of Guangxi(2023GXNSFAA026246)in part by the Central Government's Guide to Local Science and Technology Development Fund(GuikeZY23055044)in part by the National Natural Science Foundation of China(62363003)。
文摘In this paper,we consider the maximal positive definite solution of the nonlinear matrix equation.By using the idea of Algorithm 2.1 in ZHANG(2013),a new inversion-free method with a stepsize parameter is proposed to obtain the maximal positive definite solution of nonlinear matrix equation X+A^(*)X|^(-α)A=Q with the case 0<α≤1.Based on this method,a new iterative algorithm is developed,and its convergence proof is given.Finally,two numerical examples are provided to show the effectiveness of the proposed method.
基金supported by the National Science Foundation of China(No.62171387)the Science and Technology Program of Sichuan Province(No.2024NSFSC0468)the China Postdoctoral Science Foundation(No.2019M663475).
文摘As an important resource in data link,time slots should be strategically allocated to enhance transmission efficiency and resist eavesdropping,especially considering the tremendous increase in the number of nodes and diverse communication needs.It is crucial to design control sequences with robust randomness and conflict-freeness to properly address differentiated access control in data link.In this paper,we propose a hierarchical access control scheme based on control sequences to achieve high utilization of time slots and differentiated access control.A theoretical bound of the hierarchical control sequence set is derived to characterize the constraints on the parameters of the sequence set.Moreover,two classes of optimal hierarchical control sequence sets satisfying the theoretical bound are constructed,both of which enable the scheme to achieve maximum utilization of time slots.Compared with the fixed time slot allocation scheme,our scheme reduces the symbol error rate by up to 9%,which indicates a significant improvement in anti-interference and eavesdropping capabilities.
文摘In this paper,we define for the trace operator,the solution of certain models of vibrating plates standards with initial data in a strategic region spaces of weak regularities.Indeed,we know that the notion of regional controllability is more adapted to systems described by dynamic systems.Regional controllability results in a strategic area were established for vibrating plates by the Hilbertian Uniqueness Method.
基金supported by Youth Innovation Promotion Association of Chinese Academy of Sciences(No.2020261)Strategic Priority Research Program of Chinese Academy of Sciences(No.XDA02010000)the Young Potential Program of Shanghai Institute of Applied Physics,Chinese Academy of Sciences(No.SINAP-YXJH-202412).
文摘Molten salt reactors,being the only reactor type among Generation Ⅳ advanced nuclear reactors that utilize liquid fuels,offer inherent safety,high-temperature,and low-pressure operation,as well as the capability for online fuel reprocessing.However,the fuel-salt flow results in the decay of delayed neutron precursors(DNPs)outside the core,causing fluctuations in the effective delayed neutron fraction and consequently impacting the reactor reactivity.Particularly in accident scenarios—such as a combined pump shutdown and the inability to rapidly scram the reactor—the sole reliance on negative temperature feedback may cause a significant increase in core temperature,posing a threat to reactor safety.To address these problems,this paper introduces an innovative design for a passive fluid-driven suspended control rod(SCR)to dynamically compensate for reactivity fluctuations caused by DNPs flowing with the fuel.The control rod operates passively by leveraging the combined effects of gravity,buoyancy,and fluid dynamic forces,thereby eliminating the need for an external drive mechanism and enabling direct integration within the active region of the core.Using a 150 MWt thorium-based molten salt reactor as the reference design,we develop a mathematical model to systematically analyze the effects of key parameters—including the geometric dimensions and density of the SCR—on its performance.We examine its motion characteristics under different core flow conditions and assess its feasibility for the dynamic compensation of reactivity changes caused by fuel flow.The results of this study demonstrate that the SCR can effectively counteract reactivity fluctuations induced by fuel flow within molten salt reactors.A sensitivity analysis reveals that the SCR’s average density exerts a profound impact on its start-up flow threshold,channel flow rate,resistance to fuel density fluctuations,and response characteristics.This underscores the critical need to optimize this parameter.Moreover,by judiciously selecting the SCR’s length,number of deployed units,and the placement we can achieve the necessary reactivity control while maintaining a favorable balance between neutron economy and heat transfer performance.Ultimately,this paper provides an innovative solution for the passive reactivity control in molten salt reactors,offering significant potential for practical engineering applications.
文摘Apparel exports China:The decline in exports widened from January to September(-2.4%,compared to-0.2%in January-June).Exports to the EU increased(+5.9%),though the growth rate moderated.Exports to the US saw a larger contraction(January-June:-1.6%,January-September:-8.2%).While exports to ASEAN countries still fell by over 10%(-17.7%),shipments to the Philippines(+6.9%),Indonesia(+19.0%),and Cambodia(+64.9%)demonstrated stronger growth performance within the year.Regarding tariffs,on October 30,China and the US agreed to lower the rates on goods subject to additional duties(effectively reducing the average tariff rate on Chinese imports to the US from about 57%to approximately 47%,though this remains significantly higher than the 19.5%overall average rate applied to other countries).
文摘As a public basic course and the core general course of undergraduate education,moral education(ME)in College English is imperative.It is necessary to design specific teaching programs flexibly and creatively on the basis of fully understanding the ideas,objectives and tasks,basic principles and implementation methods of ME.This paper tries integrating literature reading into unit topic teaching as a new approach to ME in College English.The specific pathways of integration include:expansion of literary reading content,diversified teaching of literary reading,diversified media of literary reading,and diversified assessment system of literary quality.The integration of literature reading and unit topic teaching is conducive to the realization of the teaching goal of cultivating students’language ability,humanistic quality,and correct values.
文摘Conventional multilevel inverters often suffer from high harmonic distortion and increased design complexity due to the need for numerous power semiconductor components,particularly at elevated voltage levels.Addressing these shortcomings,thiswork presents a robust 15-level PackedUCell(PUC)inverter topology designed for renewable energy and grid-connected applications.The proposed systemintegrates a sensor less proportional-resonant(PR)controller with an advanced carrier-based pulse width modulation scheme.This approach efficiently balances capacitor voltage,minimizes steady-state error,and strongly suppresses both zero and third-order harmonics resulting in reduced total harmonic distortion and enhanced voltage regulation.Additionally,a novel switching algorithm simplifies the design and implementation,further lowering voltage stress across switches.Extensive simulation results validate the performance under various resistive and resistive-inductive load conditions,demonstrating compliance with IEEE-519 THD standards and robust operation under dynamic changes.The proposed sensorless PR-controlled 15-PUC inverter thus offers a compelling,cost-effective solution for efficient power conversion in next-generation renewable energy systems.
基金supported in part by the National Natural Science Foundation of China,Grant/Award Number:62003267the Key Research and Development Program of Shaanxi Province,Grant/Award Number:2023-GHZD-33Open Project of the State Key Laboratory of Intelligent Game,Grant/Award Number:ZBKF-23-05。
文摘To address the issue of instability or even imbalance in the orientation and attitude control of quadrotor unmanned aerial vehicles(QUAVs)under random disturbances,this paper proposes a distributed antidisturbance data-driven event-triggered fusion control method,which achieves efficient fault diagnosis while suppressing random disturbances and mitigating communication conflicts within the QUAV swarm.First,the impact of random disturbances on the UAV swarm is analyzed,and a model for orientation and attitude control of QUAVs under stochastic perturbations is established,with the disturbance gain threshold determined.Second,a fault diagnosis system based on a high-gain observer is designed,constructing a fault gain criterion by integrating orientation and attitude information from QUAVs.Subsequently,a model-free dynamic linearization-based data modeling(MFDLDM)framework is developed using model-free adaptive control,which efficiently fits the nonlinear control model of the QUAV swarm while reducing temporal constraints on control data.On this basis,this paper constructs a distributed data-driven event-triggered controller based on the staggered communication mechanism,which consists of an equivalent QUAV controller and an event-triggered controller,and is able to reduce the communication conflicts while suppressing the influence of random interference.Finally,by incorporating random disturbances into the controller,comparative experiments and physical validations are conducted on the QUAV platforms,fully demonstrating the strong adaptability and robustness of the proposed distributed event-triggered fault-tolerant control system.
文摘AIM:To investigate the effects of binocular fusional C-optotypes(positive/negative)and 2D planar C-optotypes on the amplitude and stability of transient accommodation(TAC)in adults,and to provide a basis for non-contact myopia intervention.METHODS:This was a self-controlled study.Using redblue 3D technology,four experimental stages were set up:Test A[fixating on the 1 m negative fusional C-optotypes,8△base-in(BI)],Test B(fixating on the 5 m planar C-optotypes),Test C(fixating on the 1 m planar C-optotypes),and Test D[fixating on the 1 m positive fusional C-optotypes,20△base-out(BO)].A WAM-5500 open-field autorefractor was used to measure TAC and accommodative microfluctuations[evaluated via interquartile range(IQR)and median-based coefficient of variation(CVmed)].Additionally,the convergence accommodation to convergence(CA/C)ratio was calculated,and a visual fatigue questionnaire was administered to assess participants’subjective visual comfort.RESULTS:A total of 21 subjects(7 males,14 females;aged 23-41y)with normal binocular visual function were enrolled.The results showed that the TAC increased gradually across the four stages,and these values were Test A(-0.35±0.26 D)<Test B(-0.46±0.24 D)<Test C(-0.77±0.32 D)<Test D(-1.38±0.31 D).There were significant overall differences(F=56.136,P<0.001).Compared with Test C,Test A reduced TAC by 0.42 D(P<0.05),while Test D increased it by 0.61 D(P<0.001).There was no significant intergroup difference in accommodative fluctuation amplitude(all P>0.05),but the fluctuation stability of Test D showed a significant difference between the first 20s and the second 20s(P=0.017).The CA/C ratio was significantly higher in Test D(0.05±0.02 D/△)than in Test A(0.03±0.02 D/△,P=0.007),indicating stronger accommodation-convergence linkage during positive fusional fixation.The visual fatigue scores of all stages were low(median 0-1),with Test D slightly higher than Test B and Test C(P<0.05).No linear correlation was found between TAC and age(all r<0.1,P>0.05).CONCLUSION:Negative fusional C-optotypes induce ciliary muscle relaxation to reduce TAC,while positive fusional C-optotypes enhance accommodation-convergence coordination to increase TAC.The red-blue 3D-based noncontact training mode exhibits good safety(median visual fatigue scores:0-1 across all tests)and provides a novel dual-directional(relaxation-activation)strategy for myopia prevention and control.
基金supported by Guangdong Basic and Applied Basic Research Foundation(Nos.2023A1515110824 and 2025A1515011839)Shenzhen Science and Technology Program(No.RCBS20231211090638066).
文摘Understanding water chemistry in karst regions is crucial for improving global water resource management and deepening our knowledge of the biogeochemical cycles shaping these sensitive environments.Despite advance-ments in karst hydrology,significant gaps remain in long-term trends,underlying processes,and quantitative effects of environmental changes.This is especially true in areas like the Wujiang River(WJ)in China,where human activities such as reservoir construction and land use/cover changes have accelerated hydrochemical changes.We combined recent and historical monitoring data to provide a detailed analysis of the spatial and temporal characteristics,evolution,and controlling factors of major ions in WJ.These findings are important for local water management and contribute to global efforts to manage similar karst systems facing human-induced pressures.Our research shows clear seasonal differences in solute concentrations,with higher levels during the dry season.WJ’s water is rich in calcium,with Ca-HCO_(3) ion pairs being the most common.Reservoir monitor-ing stations show much higher levels of NO_(3)^(−)and SO_(4)^(2−)compared to river-type stations,likely due to longer hydraulic retention time and increased acid deposition.The study confirms the significant role of pH and water temperature in rock weathering processes.Land use/cover changes were identified as the primary drivers of solute variations(46.37%),followed by lithology(13.92%)and temperature(8.35%).Over the past two decades,in-tense carbonate weathering has been observed,especially during wet seasons.Among karstic provinces,Guizhou Province stands out with the highest ion concentrations,indicative of its extensive karst coverage and heightened weathering processes.