This review proposes associated standards from abroad regarding chemical contamination of the air, and has analyzed the formation of chemical air pollution, the common contaminants and the testing methods of projects....This review proposes associated standards from abroad regarding chemical contamination of the air, and has analyzed the formation of chemical air pollution, the common contaminants and the testing methods of projects. This paper demonstrates the capability of China to begin commercial testing of chemical contamination of the air. In addition, it offers technological references of the feasibility for adopting the international standard ISO14644-8:2006.展开更多
Flashover on polluted insulators is the most common accident occuring in power system.A great amount of work has been done to study the flashover characteristics on various kinds of insulators with several theoretical...Flashover on polluted insulators is the most common accident occuring in power system.A great amount of work has been done to study the flashover characteristics on various kinds of insulators with several theoretical models proposed.In these models,the amount and the distribution of the pollution on the insulator is critical to the flashover performance.However,very few simulation works has been carried out to study the pollution accumulation characteristics on the insulators.In this paper,both experimental and numerical efforts were given to study the pollution accumulation characteristics in order to evaluate the flashover probability.Experiments were performed first to have a bird view on the overall pollution distributions considering several crucial influential factors such as the wind speed and wind direction.AC porcelain insulators(XWP_2-160 type) were selected as the experimental samples and the equivalent salt deposit density(ESDD) was measured after the total predetermined amount of pollution was reached.Then, aerodynamic simulation was carried out to study the airflow and velocity distributions on each part of the insulator in clean air with regard to different wind speed and direction.It was found that the amount of the pollution on each section of the insulator has clear connections to the wind speed or air pressure distribution on the insulator surface.These distributions coincide to the pollution distribution obtained from experiments.Besides,the wind speed and air pressure distribution along the insulator chain was also studied.This work has shown that the numerical simulation may predict the pollution distribution on the insulators with practical accuracy.It is also possible to design new insulator shapes to reduce the pollution accumulation on critical areas according to the analysis in this work.展开更多
The present investigation studied the toxicity of soil contaminated by untreated discharge from a factory that recycles used plastics. The nearby agricultural areas and freshwater fish ponds were polluted with high co...The present investigation studied the toxicity of soil contaminated by untreated discharge from a factory that recycles used plastics. The nearby agricultural areas and freshwater fish ponds were polluted with high concentrations of Cu, Ni, and Mn. Water extracts from the contaminated soil retarded root growth of Brassica chinensis (Chinese white cabbage) and Cynodon dactylon (Bermuda grass) where their seeds were obtained commercially. The contaminated populations of C. dactylon, Panicum repen (panic grass), and Imperata cylindrica (wooly grass) were able to withstand higher concentrations of Cu. Ni, and Mn, especially C. dactylon, when compared with their uncontaminated counterparts. 1990 Academic Press, Inc.展开更多
文摘This review proposes associated standards from abroad regarding chemical contamination of the air, and has analyzed the formation of chemical air pollution, the common contaminants and the testing methods of projects. This paper demonstrates the capability of China to begin commercial testing of chemical contamination of the air. In addition, it offers technological references of the feasibility for adopting the international standard ISO14644-8:2006.
基金Supported by East China Grid Company Ltd(200933- 04316C156)
文摘Flashover on polluted insulators is the most common accident occuring in power system.A great amount of work has been done to study the flashover characteristics on various kinds of insulators with several theoretical models proposed.In these models,the amount and the distribution of the pollution on the insulator is critical to the flashover performance.However,very few simulation works has been carried out to study the pollution accumulation characteristics on the insulators.In this paper,both experimental and numerical efforts were given to study the pollution accumulation characteristics in order to evaluate the flashover probability.Experiments were performed first to have a bird view on the overall pollution distributions considering several crucial influential factors such as the wind speed and wind direction.AC porcelain insulators(XWP_2-160 type) were selected as the experimental samples and the equivalent salt deposit density(ESDD) was measured after the total predetermined amount of pollution was reached.Then, aerodynamic simulation was carried out to study the airflow and velocity distributions on each part of the insulator in clean air with regard to different wind speed and direction.It was found that the amount of the pollution on each section of the insulator has clear connections to the wind speed or air pressure distribution on the insulator surface.These distributions coincide to the pollution distribution obtained from experiments.Besides,the wind speed and air pressure distribution along the insulator chain was also studied.This work has shown that the numerical simulation may predict the pollution distribution on the insulators with practical accuracy.It is also possible to design new insulator shapes to reduce the pollution accumulation on critical areas according to the analysis in this work.
文摘The present investigation studied the toxicity of soil contaminated by untreated discharge from a factory that recycles used plastics. The nearby agricultural areas and freshwater fish ponds were polluted with high concentrations of Cu, Ni, and Mn. Water extracts from the contaminated soil retarded root growth of Brassica chinensis (Chinese white cabbage) and Cynodon dactylon (Bermuda grass) where their seeds were obtained commercially. The contaminated populations of C. dactylon, Panicum repen (panic grass), and Imperata cylindrica (wooly grass) were able to withstand higher concentrations of Cu. Ni, and Mn, especially C. dactylon, when compared with their uncontaminated counterparts. 1990 Academic Press, Inc.