The DC microgrid has the advantages of high energy conversion efficiency,high energy transmission density,no reactive power flow,and grid-connected synchronization.It is an essential component of the future intelligen...The DC microgrid has the advantages of high energy conversion efficiency,high energy transmission density,no reactive power flow,and grid-connected synchronization.It is an essential component of the future intelligent power distribution system.Constant power load(CPL)will degrade the stability of the DC microgrid and cause system voltage oscillation due to its negative resistance characteristics.As a result,the stability of DC microgrids with CPL has become a problem.At present,the research on the stability of DC microgrid is mainly focused on unipolar DC microgrid,while the research on bipolar DC microgrid lacks systematic discussion.The stability of DC microgrid using CPL was studied first,and then the current stability criteria of DC microgrid were summarized,and its research trend was analyzed.On this basis,aiming at the stability problem caused by CPL,the existing control methods were summarized from the perspective of source converter output impedance and load converter input impedance,and the current control methods were outlined as active and passive control methods.Lastly,the research path of bipolar DC microgrid stability with CPL was prospected.展开更多
The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the ...The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the design of stabilizing controllers. In this work, a robust nonlinear controller based on the uncertainty and disturbance estimator (UDE) scheme is successfully developed to tightly regulate the output voltage of the boost converter. A systematic procedure is developed to select the controller gains to achieve a satisfactory output response. Using simulation, the effectiveness of the proposed controller is validated and compared to a recent robust nonlinear controller.展开更多
The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the ...The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the design of stabilizing controllers. A PWM-based current-sensorless robust sliding mode controller is developed that requires only the measurement of the output voltage. An extended state observer is developed to estimate a lumped uncertainty signal that comprises the uncertain load power and the input voltage, the converter parasitics, the component uncertainties and the estimation of the derivative of the output voltage needed in the implementation of the controller. A linear sliding surface is used to derive the controller, which is simple in its design and yet exhibits excellent features in terms of robustness to external disturbances, parameter uncertainties, and parasitics despite the absence of the inductor’s current feedback. The robustness of the controller is validated by computer simulations.展开更多
Optimizing photovoltaic(PV)power utilization in battery systems is challenging due to solar intermittency,battery efficiency,and lifespan management.This paper proposes a novel forecast-based battery charging manageme...Optimizing photovoltaic(PV)power utilization in battery systems is challenging due to solar intermittency,battery efficiency,and lifespan management.This paper proposes a novel forecast-based battery charging management(BCM)strategy to enhance PV power utilization.A string of Li-ion battery cells with diverse capacities and states of charge(SOC)is contemplated in this constant current/-constant voltage(CC/CV)battery-charging scheme.Significant amounts of PV power are often wasted because the CC/CV mode cannot fully exploit the available power to maintain appropriate charging rates.To address this issue,the proposed BCM algorithm selects an optimal set of battery cells for charging at any given time based on forecasted PV power generation,ensuring maximum power is obtained from the PV system.Additionally,a support vector regression(SVR)-based forecasting model is developed to predict PV power generation precisely.The results indicate that the anticipated BCM strategy achieves an overall utilization rate of 87.47%of the PVgenerated power for battery charging under various weather conditions.展开更多
Majority of non-Newtonian fluids are pseudoplastic with shear-thinning property, which means that the viscosity will be different in different parts of the stirred tank. In such mixing process, it is difficult to pred...Majority of non-Newtonian fluids are pseudoplastic with shear-thinning property, which means that the viscosity will be different in different parts of the stirred tank. In such mixing process, it is difficult to predict accurately the power consumption and mean shear rate for designing novel impeller. Metzner-Otto method is a widely accepted method to solve these questions in mixing non-Newtonian fluids. As a result, Metzner-Otto constant will become a key factor to achieve an optimum way of economical mixing. In this paper, taking glycerine and xanthan gum solutions as research system, the power consumption, stirred by the impeller composed of perturbed six-bent-bladed turbine (6PBT) with differently geometrical characteristics in a cylindrical vessel, is studied by means of computational fluid dynamics (CFD). The flow is modeled as laminar and a multiple reference frame (MRF) approach is used to solve the discretized equations of motion. In order to determine the capability of CFD to forecast the flow process, the torque test experiment is used to measure the glycerine solution power consumption. The theological properties of the xanthan gum solutions are determined by a Brookfleld rheometer. It is observed that the power consumption predicted by numerical simulation agrees well with those measured using torque experiment method in stirring glycerine solution, which validate the numerical model. Metzner-Otto constant is almost not correlated with the flow behavior index of pseudoplastic fluids. This paper establishes the complete correlations of power constant and Metzner-Otto constant with impeller geometrical characteristics through linear regression analysis, which provides the valuable instructions and references for accurately predicting the power consumption and mean shear rate of pseudoplastic fluids in laminar flow, comparatively.展开更多
AIM: To evaluate the effect of different lens constant optimization methods on the accuracy of intraocular lens(IOL) power calculation formulas for highly myopic eyes.METHODS: This study comprised 108 eyes of 94 conse...AIM: To evaluate the effect of different lens constant optimization methods on the accuracy of intraocular lens(IOL) power calculation formulas for highly myopic eyes.METHODS: This study comprised 108 eyes of 94 consecutive patients with axial length(AL) over 26 mm undergoing phacoemulsification and implantation of a Rayner(Hove, UK) 920H IOL. Formulas were evaluated using the following lens constants: manufacturer’s lens constant, User Group for Laser Interference Biometry(ULIB) constant, and optimized constant for long eyes. Results were compared with Barrett Universal II formula, original Wang-Koch AL adjustment method, and modified Wang-Koch AL adjustment method. The outcomes assessed were mean absolute error(MAE) and percentage of eyes with IOL prediction errors within ±0.25, ±0.50, and ±1.0 diopter(D). The nonparametric method, Friedman test, was used to compare MAE performance among constants.RESULTS: Optimized constants could significantly reduce the MAE of SRK/T, Hoffer Q, and Holladay 1 formulas compared with manufacturer’s lens constant, whereas the percentage of eyes with IOL prediction errors within ±0.25, ±0.50, and ±1.0 D had no statistically significant differences. Optimized lens constant for long eyes alone showed non-significant refractive advantages over the ULIB constant. Barrett Universal II formula and formulas with AL adjustment showed significantly higher accuracy in highly myopic eyes(P<0.001). CONCLUSION: Lens constant optimization for the subset of long eyes reduces the refractive error only to a limited extent for highly myopic eyes.展开更多
Based on the characteristic of AC-excited variable speed constant frequency(VSCF)wind power generation,the vector control technique was applied in a doubly fed induction generator(DFIG).Maximum wind energy or maximum ...Based on the characteristic of AC-excited variable speed constant frequency(VSCF)wind power generation,the vector control technique was applied in a doubly fed induction generator(DFIG).Maximum wind energy or maximum output power point can be tracked by decoupling control of active power and reactive power.The research result shows that the net power of generation system delivered to grid in maximum wind energy tracking mode is not the most.We presented a novel maximum power point tracking(MPPT)control strategy by analyzing the DFIG mathematic model and power relations which delivered the maximum power to the grid.The maximum power point could be tracked automatically without measuring wind speed in the control strategy and the control was independent of optimal turbine power curve,which had excellent dynamic and static performances and robustness.Simulation and experimental results testify the accuracy and validity of the control strategy.展开更多
In this paper, we propose a smart step closed-loop power control (SSPC) algorithm and a base station assignment method based on minimizing the transmitter power (BSA-MTP) technique in a direct sequence-code division m...In this paper, we propose a smart step closed-loop power control (SSPC) algorithm and a base station assignment method based on minimizing the transmitter power (BSA-MTP) technique in a direct sequence-code division multiple access (DS-CDMA) receiver with frequency-selective Rayleigh fading. This receiver consists of three stages. In the first stage, with constrained least mean squared (CLMS) algorithm, the desired users’ signal in an arbitrary path is passed and the inter-path interference (IPI) is reduced in other paths in each RAKE finger. Also in this stage, the multiple access interference (MAI) from other users is reduced. Thus, the matched filter (MF) can use for more reduction of the IPI and MAI in each RAKE finger in the second stage. Also in the third stage, the output signals from the matched filters are combined according to the conventional maximal ratio combining (MRC) principle and then are fed into the decision circuit of the desired user. The simulation results indicate that the SSPC algorithm and the BSA-MTP technique can significantly reduce the network bit error rate (BER) compared to the other methods. Also, we observe that significant savings in total transmit power (TTP) are possible with our methods.展开更多
In order to make the power level angle(PLA)have the same bijection relationship with the thrust when the environment changes before operational limit exceedance,and ensure the pilot's ability of unrestricted throt...In order to make the power level angle(PLA)have the same bijection relationship with the thrust when the environment changes before operational limit exceedance,and ensure the pilot's ability of unrestricted throttle movement as well as the safety of the engine,a method used to design a constant thrust power schedule was proposed.The research was based on a simulink turbofan engine model and the results were organized as look-up tables in different structures with limitations.Simulation was done to confirm the validity and demonstrate the effectiveness of the schedule obtained with the approach.The constant thrust takeoff schedule,constant thrust idle schedule and constant thrust part power schedule with the present constant thrust control(CTC)method were proved to be valid.The results can be applied to this specific engine but the method can be applied to any areoengine and can be even extended to the unmanned plane.展开更多
The study on homogeneous DBDs at atmospheric pressure has attracted much attention for their advantages in applications. Tremendous work has been conducted both experimentally and numerically at a constant applied vol...The study on homogeneous DBDs at atmospheric pressure has attracted much attention for their advantages in applications. Tremendous work has been conducted both experimentally and numerically at a constant applied voltage or driving frequency. However the investigation of dielectric barrier discharges is still scarce for a constant power or power density. In this work, a new computational approach for DBDs is developed to explore atmospheric DBDs at a constant power based on a one-dimensional fluid model. The frequency and gap spacing effects on the atmospheric plasmas are systematically analyzed based on computational data. The computational results show that at a constant power both the current density and the amplitude of the applied voltage decrease, whereas the current pulse width increases, with increasing frequency. The simulation also indicates that as the gap spacing is raised with a fixed power and frequency, the current density and electron density increase initially, then reach their peak values, and then decrease, which means that there are maximum values for both of them. These results are significant for many industrial applications, as they can be used to optimize plasma devices of DBDs with the consideration of power consumption.展开更多
The interference reduction capability of antenna arrays and the power control algorithms have been considered separately as means to decrease the interference in wireless communication networks. In this paper, we prop...The interference reduction capability of antenna arrays and the power control algorithms have been considered separately as means to decrease the interference in wireless communication networks. In this paper, we propose smart step closed-loop power control (SSPC) algorithm in wireless networks in a 2D urban environment with constrained least mean squared (CLMS) algorithm. This algorithm is capable of efficiently adapting according to the environment and able to permanently maintain the chosen frequency response in the look direction while minimizing the output power of the array. Also, we present switched-beam (SB) technique for enhancing signal to interference plus noise ratio (SINR) in wireless networks. Also, we study an analytical approach for the evaluation of the impact of power control error (PCE) on wireless networks in a 2D urban environment. The simulation results indicate that the convergence speed of the SSPC algorithm is faster than other algorithms. Also, we observe that significant saving in total transmit power (TTP) are possible with our proposed algorithm. Finally, we discuss three parameters of the PCE, number of antenna elements, and path-loss exponent and their effects on capacity of the system via some computer simulations.展开更多
针对无线电能传输WPT(wireless power transmission)系统耦合机构发生偏移时,输出电压波动的问题,提出1种基于恒压输出区间追踪的WPT系统抗偏移方法。首先,建立CLC-S型WPT系统的模型,分析该系统在谐振和非谐振状态下的互感与输出电压增...针对无线电能传输WPT(wireless power transmission)系统耦合机构发生偏移时,输出电压波动的问题,提出1种基于恒压输出区间追踪的WPT系统抗偏移方法。首先,建立CLC-S型WPT系统的模型,分析该系统在谐振和非谐振状态下的互感与输出电压增益之间的关系,由分析可知,系统工作在非谐振状态下的恒压输出区间内抗偏移能力更强;然后,设计电感补偿序列,提出恒压输出区间追踪控制策略,实现WPT系统输出电压恒定控制,提高系统的抗偏移能力;最后,搭建仿真模型和实验平台,仿真及实验结果均表明,采用恒压输出区间追踪控制策略,可以有效减小输出电压的波动,验证了系统在强互感干扰下的鲁棒性。相较于无恒压输出区间追踪的WPT系统,所提系统具有更好的输出电压动态调节能力。展开更多
基金supported by National Natural Science Foundation of China(No.51767015)Key Project of Natural Science Foundation of Gansu Province(No.22JR5RA317)Tianyou Innovation Team Support Program of Lanzhou Jiaotong University(No.TY202009)。
文摘The DC microgrid has the advantages of high energy conversion efficiency,high energy transmission density,no reactive power flow,and grid-connected synchronization.It is an essential component of the future intelligent power distribution system.Constant power load(CPL)will degrade the stability of the DC microgrid and cause system voltage oscillation due to its negative resistance characteristics.As a result,the stability of DC microgrids with CPL has become a problem.At present,the research on the stability of DC microgrid is mainly focused on unipolar DC microgrid,while the research on bipolar DC microgrid lacks systematic discussion.The stability of DC microgrid using CPL was studied first,and then the current stability criteria of DC microgrid were summarized,and its research trend was analyzed.On this basis,aiming at the stability problem caused by CPL,the existing control methods were summarized from the perspective of source converter output impedance and load converter input impedance,and the current control methods were outlined as active and passive control methods.Lastly,the research path of bipolar DC microgrid stability with CPL was prospected.
文摘The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the design of stabilizing controllers. In this work, a robust nonlinear controller based on the uncertainty and disturbance estimator (UDE) scheme is successfully developed to tightly regulate the output voltage of the boost converter. A systematic procedure is developed to select the controller gains to achieve a satisfactory output response. Using simulation, the effectiveness of the proposed controller is validated and compared to a recent robust nonlinear controller.
文摘The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the design of stabilizing controllers. A PWM-based current-sensorless robust sliding mode controller is developed that requires only the measurement of the output voltage. An extended state observer is developed to estimate a lumped uncertainty signal that comprises the uncertain load power and the input voltage, the converter parasitics, the component uncertainties and the estimation of the derivative of the output voltage needed in the implementation of the controller. A linear sliding surface is used to derive the controller, which is simple in its design and yet exhibits excellent features in terms of robustness to external disturbances, parameter uncertainties, and parasitics despite the absence of the inductor’s current feedback. The robustness of the controller is validated by computer simulations.
文摘Optimizing photovoltaic(PV)power utilization in battery systems is challenging due to solar intermittency,battery efficiency,and lifespan management.This paper proposes a novel forecast-based battery charging management(BCM)strategy to enhance PV power utilization.A string of Li-ion battery cells with diverse capacities and states of charge(SOC)is contemplated in this constant current/-constant voltage(CC/CV)battery-charging scheme.Significant amounts of PV power are often wasted because the CC/CV mode cannot fully exploit the available power to maintain appropriate charging rates.To address this issue,the proposed BCM algorithm selects an optimal set of battery cells for charging at any given time based on forecasted PV power generation,ensuring maximum power is obtained from the PV system.Additionally,a support vector regression(SVR)-based forecasting model is developed to predict PV power generation precisely.The results indicate that the anticipated BCM strategy achieves an overall utilization rate of 87.47%of the PVgenerated power for battery charging under various weather conditions.
基金Supported by Shandong Provincial Science and Technology Development planning Program of China(Grant No.2013YD09007)Scientific Foundation of Qingdao University of Science and Technology of China
文摘Majority of non-Newtonian fluids are pseudoplastic with shear-thinning property, which means that the viscosity will be different in different parts of the stirred tank. In such mixing process, it is difficult to predict accurately the power consumption and mean shear rate for designing novel impeller. Metzner-Otto method is a widely accepted method to solve these questions in mixing non-Newtonian fluids. As a result, Metzner-Otto constant will become a key factor to achieve an optimum way of economical mixing. In this paper, taking glycerine and xanthan gum solutions as research system, the power consumption, stirred by the impeller composed of perturbed six-bent-bladed turbine (6PBT) with differently geometrical characteristics in a cylindrical vessel, is studied by means of computational fluid dynamics (CFD). The flow is modeled as laminar and a multiple reference frame (MRF) approach is used to solve the discretized equations of motion. In order to determine the capability of CFD to forecast the flow process, the torque test experiment is used to measure the glycerine solution power consumption. The theological properties of the xanthan gum solutions are determined by a Brookfleld rheometer. It is observed that the power consumption predicted by numerical simulation agrees well with those measured using torque experiment method in stirring glycerine solution, which validate the numerical model. Metzner-Otto constant is almost not correlated with the flow behavior index of pseudoplastic fluids. This paper establishes the complete correlations of power constant and Metzner-Otto constant with impeller geometrical characteristics through linear regression analysis, which provides the valuable instructions and references for accurately predicting the power consumption and mean shear rate of pseudoplastic fluids in laminar flow, comparatively.
基金Supported by National Natural Science Foundation of China(No.81770905)
文摘AIM: To evaluate the effect of different lens constant optimization methods on the accuracy of intraocular lens(IOL) power calculation formulas for highly myopic eyes.METHODS: This study comprised 108 eyes of 94 consecutive patients with axial length(AL) over 26 mm undergoing phacoemulsification and implantation of a Rayner(Hove, UK) 920H IOL. Formulas were evaluated using the following lens constants: manufacturer’s lens constant, User Group for Laser Interference Biometry(ULIB) constant, and optimized constant for long eyes. Results were compared with Barrett Universal II formula, original Wang-Koch AL adjustment method, and modified Wang-Koch AL adjustment method. The outcomes assessed were mean absolute error(MAE) and percentage of eyes with IOL prediction errors within ±0.25, ±0.50, and ±1.0 diopter(D). The nonparametric method, Friedman test, was used to compare MAE performance among constants.RESULTS: Optimized constants could significantly reduce the MAE of SRK/T, Hoffer Q, and Holladay 1 formulas compared with manufacturer’s lens constant, whereas the percentage of eyes with IOL prediction errors within ±0.25, ±0.50, and ±1.0 D had no statistically significant differences. Optimized lens constant for long eyes alone showed non-significant refractive advantages over the ULIB constant. Barrett Universal II formula and formulas with AL adjustment showed significantly higher accuracy in highly myopic eyes(P<0.001). CONCLUSION: Lens constant optimization for the subset of long eyes reduces the refractive error only to a limited extent for highly myopic eyes.
基金Funded by the National Natural Science Foundation of China(No.60974049)the Science and Technology Support Industrial Project of Jiangsu Province(No.BZ2008031,No.BE2008074,and No.BE2009090)+1 种基金the Nantong International Cooperative Project(No.W2009003)the Natural Science Foundation of Nantong University(No.08Z022 and No.08Z025).
文摘Based on the characteristic of AC-excited variable speed constant frequency(VSCF)wind power generation,the vector control technique was applied in a doubly fed induction generator(DFIG).Maximum wind energy or maximum output power point can be tracked by decoupling control of active power and reactive power.The research result shows that the net power of generation system delivered to grid in maximum wind energy tracking mode is not the most.We presented a novel maximum power point tracking(MPPT)control strategy by analyzing the DFIG mathematic model and power relations which delivered the maximum power to the grid.The maximum power point could be tracked automatically without measuring wind speed in the control strategy and the control was independent of optimal turbine power curve,which had excellent dynamic and static performances and robustness.Simulation and experimental results testify the accuracy and validity of the control strategy.
文摘In this paper, we propose a smart step closed-loop power control (SSPC) algorithm and a base station assignment method based on minimizing the transmitter power (BSA-MTP) technique in a direct sequence-code division multiple access (DS-CDMA) receiver with frequency-selective Rayleigh fading. This receiver consists of three stages. In the first stage, with constrained least mean squared (CLMS) algorithm, the desired users’ signal in an arbitrary path is passed and the inter-path interference (IPI) is reduced in other paths in each RAKE finger. Also in this stage, the multiple access interference (MAI) from other users is reduced. Thus, the matched filter (MF) can use for more reduction of the IPI and MAI in each RAKE finger in the second stage. Also in the third stage, the output signals from the matched filters are combined according to the conventional maximal ratio combining (MRC) principle and then are fed into the decision circuit of the desired user. The simulation results indicate that the SSPC algorithm and the BSA-MTP technique can significantly reduce the network bit error rate (BER) compared to the other methods. Also, we observe that significant savings in total transmit power (TTP) are possible with our methods.
文摘In order to make the power level angle(PLA)have the same bijection relationship with the thrust when the environment changes before operational limit exceedance,and ensure the pilot's ability of unrestricted throttle movement as well as the safety of the engine,a method used to design a constant thrust power schedule was proposed.The research was based on a simulink turbofan engine model and the results were organized as look-up tables in different structures with limitations.Simulation was done to confirm the validity and demonstrate the effectiveness of the schedule obtained with the approach.The constant thrust takeoff schedule,constant thrust idle schedule and constant thrust part power schedule with the present constant thrust control(CTC)method were proved to be valid.The results can be applied to this specific engine but the method can be applied to any areoengine and can be even extended to the unmanned plane.
文摘The study on homogeneous DBDs at atmospheric pressure has attracted much attention for their advantages in applications. Tremendous work has been conducted both experimentally and numerically at a constant applied voltage or driving frequency. However the investigation of dielectric barrier discharges is still scarce for a constant power or power density. In this work, a new computational approach for DBDs is developed to explore atmospheric DBDs at a constant power based on a one-dimensional fluid model. The frequency and gap spacing effects on the atmospheric plasmas are systematically analyzed based on computational data. The computational results show that at a constant power both the current density and the amplitude of the applied voltage decrease, whereas the current pulse width increases, with increasing frequency. The simulation also indicates that as the gap spacing is raised with a fixed power and frequency, the current density and electron density increase initially, then reach their peak values, and then decrease, which means that there are maximum values for both of them. These results are significant for many industrial applications, as they can be used to optimize plasma devices of DBDs with the consideration of power consumption.
文摘The interference reduction capability of antenna arrays and the power control algorithms have been considered separately as means to decrease the interference in wireless communication networks. In this paper, we propose smart step closed-loop power control (SSPC) algorithm in wireless networks in a 2D urban environment with constrained least mean squared (CLMS) algorithm. This algorithm is capable of efficiently adapting according to the environment and able to permanently maintain the chosen frequency response in the look direction while minimizing the output power of the array. Also, we present switched-beam (SB) technique for enhancing signal to interference plus noise ratio (SINR) in wireless networks. Also, we study an analytical approach for the evaluation of the impact of power control error (PCE) on wireless networks in a 2D urban environment. The simulation results indicate that the convergence speed of the SSPC algorithm is faster than other algorithms. Also, we observe that significant saving in total transmit power (TTP) are possible with our proposed algorithm. Finally, we discuss three parameters of the PCE, number of antenna elements, and path-loss exponent and their effects on capacity of the system via some computer simulations.
文摘针对无线电能传输WPT(wireless power transmission)系统耦合机构发生偏移时,输出电压波动的问题,提出1种基于恒压输出区间追踪的WPT系统抗偏移方法。首先,建立CLC-S型WPT系统的模型,分析该系统在谐振和非谐振状态下的互感与输出电压增益之间的关系,由分析可知,系统工作在非谐振状态下的恒压输出区间内抗偏移能力更强;然后,设计电感补偿序列,提出恒压输出区间追踪控制策略,实现WPT系统输出电压恒定控制,提高系统的抗偏移能力;最后,搭建仿真模型和实验平台,仿真及实验结果均表明,采用恒压输出区间追踪控制策略,可以有效减小输出电压的波动,验证了系统在强互感干扰下的鲁棒性。相较于无恒压输出区间追踪的WPT系统,所提系统具有更好的输出电压动态调节能力。