期刊文献+
共找到234篇文章
< 1 2 12 >
每页显示 20 50 100
Reliability of a computerized system for strabismus screening
1
作者 Supaporn Tengtrisorn Alan Frederick Geater 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期126-130,共5页
AIM:To evaluate the reliability of Photo-Hirschberg screening for global strabismus performed by non-specialized personnel.METHODS:Participants at three sites were enrolled.One person at each site was trained in visua... AIM:To evaluate the reliability of Photo-Hirschberg screening for global strabismus performed by non-specialized personnel.METHODS:Participants at three sites were enrolled.One person at each site was trained in visual acuity measurement and use of the computerized system.Visual acuity was measured,and strabismus testing was performed using two flash photographs.All data from the three primary observers were sent to an experienced assistant researcher,who was blinded to the primary results,for re-evaluation.The primary and re-evaluation results of the Photo-Hirschberg screenings using weighted kappa for agreement were compared.RESULTS:The study included 181 participants(88 males and 93 females)and the results for primary and re-evaluation screenings were corresponded.Ten participants with contrasting results presented with unclear corneal light reflex.Sensitivity and specificity were 100%[95%confidence interval(CI):29.0%-100%]and 99.4%(95%CI:96.6%-100%),respectively,based on the Agresti test of the primary evaluation,considering the re-evaluated classification as true.CONCLUSION:The computerized system can be used for primary strabismus screening by non-specialized personnel,with 98.8%agreement with specialists.However,it cannot be used as a substitute for professional examination. 展开更多
关键词 strabismus screening computerized system Photo-Hirschberg screening
原文传递
COMPUTERIZED SIMULATION OF MOLTEN SALT SOLUTION OF Li,KF,Cl SYSTEM BY MOLECULAR DYNAMIC METHOD 被引量:2
2
作者 SHAO Jun Shanghai University of Science and Technology,Shanghai,ChinaXU Hua CHEN Nianyi Shanghai Institute of Metallurgy,Academia Sinica,Shanghai,China SHAO Jun Associate Professor,Dept.of Chemistry,Shanghai University of Science and Technology,Shanghai 201800,China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1990年第10期221-225,共5页
The structure and properties of molten salt solution o J Li,K|F,Cl system have been investiged by computerized simulation of molecular dynamic method.The partial RDF,the partial molar energy of mixing and the diffusio... The structure and properties of molten salt solution o J Li,K|F,Cl system have been investiged by computerized simulation of molecular dynamic method.The partial RDF,the partial molar energy of mixing and the diffusion coeffients of Li^+,K^+,F^- and Cl^- have been calculated. The results are in agreement with the experimental values.The regularities of the distribution of ions and mieroscopic holes are discussed based on the results of computerized simulation. 展开更多
关键词 alkali halide molten salt molecular dynamic method computerized simulation
在线阅读 下载PDF
AN ANALYSIS OF ACOUSTIC CHARACTERISTICS OFCLEFT PALATE SPEECH WITH COMPUTERIZED SPEECH SIGNAL PROCESSING SYSTEM 被引量:1
3
作者 李锦峰 刘建华 《Journal of Pharmaceutical Analysis》 CAS 1996年第2期162-165,共4页
The acoustic characteristics or the chinese vowels of 24 children with cleft palate and 10 normal control children were analyzed by computerized speech signal processing system (CSSPS),and the speech articulation was ... The acoustic characteristics or the chinese vowels of 24 children with cleft palate and 10 normal control children were analyzed by computerized speech signal processing system (CSSPS),and the speech articulation was judged with Glossary of clert palate speech(GCPS).The listening judgement showed that the speech articulation was significantly different between the two groups(P<0.01).The objective quantitative measurement suggested that the formant pattern(FP)of vowels in children with cleft palate was different from that of normal control children except vowel[a](P< 0.05).The acoustic vowelgraph or the Chinese vowels which demonstrated directly the relationship of vocal space and speech perception was stated with the first formant frequence(F1)and the second formant frequence(F2).The authors conclude that the values or F1 and F2 point out the upward and backward tongue movement to close the clert, which reflects the vocal characteristics of trausmission of clert palate speech. 展开更多
关键词 cleft palate speech the Chinese vowels the formant pattern the speech articulation computerized speech singnal processing system
暂未订购
Mediation of Computerized Accounting System (CAS) Adoption on Relationship Between Environmental Uncertainty and Organizational Performance 被引量:1
4
作者 Quang Linh Huynh Lin Yaling 《Journal of Modern Accounting and Auditing》 2013年第6期747-755,共9页
This paper investigates the mediation of the adoption of computerized accounting system (CAS) on the relationship between environmental uncertainty and organizational performance. The authors use factor analysis, pa... This paper investigates the mediation of the adoption of computerized accounting system (CAS) on the relationship between environmental uncertainty and organizational performance. The authors use factor analysis, path analysis, and regression model to examine the effects of CAS adoption on the relationship between environmental uncertainty and organizational performance. The findings reveal that the adoption level of CAS is positively associated with organizational characteristics, environmental uncertainty, and organizational performance, and the usage of CAS has a statistically significant mediating effect on the relationship between environmental uncertainty and organizational performance. This paper will be significant to business managers in the decision to adopt CAS. 展开更多
关键词 computerized accounting system (CAS) environmental uncertainty organizational performance
在线阅读 下载PDF
Computerized Simulation of the Structure of Molten DyF_3-LiF System
5
作者 徐驰 刘健 +2 位作者 陈念贻 李洁 唐定骧 《Journal of Rare Earths》 SCIE EI CAS CSCD 1993年第3期170-173,共4页
The structure of molten DyF_3-LiF system has been simulated by Monte Carlo method.The radial distribution functions(RDFs)and the local structure have been obtained.It is concluded that F^- ions distribute closely arou... The structure of molten DyF_3-LiF system has been simulated by Monte Carlo method.The radial distribution functions(RDFs)and the local structure have been obtained.It is concluded that F^- ions distribute closely around Dy^(3+) ions.There exist some fissures and holes between F^- ions and Li^+ ions. There are mainly two kinds of ionic types:the complex ions like DyF_n^(3-n) clusters with the central Dy^(3+) ions (the main ionic clusters are octahedral complex ions like DyF_6^(3-))and the“free”Li^+ ions.Moreover,some complex ions like DyF_n^(3-n) clusters are connected to one another by flourine-bridge,forming more compli- cated ionic clusters like Dy_m^(3m-n) F_n.By calculating the potential energies of all types of ions,it is concluded that Li^+ ions have the highest potential energy in the molten system,which are current-carrying ions in the electrolytic conductance. 展开更多
关键词 Rare-Earth flouride Molten salt computerized simulation Monte Carlo method Local structure
在线阅读 下载PDF
Compilation and Analysis Method for Computer Aided Pattern Design System Based on Fully-Fashioned Computerized Flat Knitting Machine
6
作者 ZHU Bin FEI Sheng-wei +1 位作者 HE Yong JIANG Yu-hao 《Journal of Donghua University(English Edition)》 EI CAS 2016年第6期961-967,共7页
The knitting industry CAD/CAM system's development needs a solution of computer representation of the designed objects. One of them is a transformation of knitting rows and stitches form knitting pattern and its auto... The knitting industry CAD/CAM system's development needs a solution of computer representation of the designed objects. One of them is a transformation of knitting rows and stitches form knitting pattern and its automatic analysis is to control data from the knitting design data. A method of the pattern CAD system including the analyzing and the compiling of the pattern data was developed in this paper. By rasterizing the pattern map, the drafted pattern could be compiled into knitting row data and stitches. The storage format of knitting rows data and stitches data could be defined by analyzing the motion of computerized fiat knitting machine. By reassembling the control data, it could be analyzed into the execute data of the controller in computerized fiat knitting machine. This method mainly focused on the weak areas of multi-needle-bed technology and fully-fashioned knitting technology in inland and could be applied to most of control systems in the master-slave mode. The knitting row data and pattern row data in a " *. ptn" format file were integrated. Giving a corresponding analytic calculation process of control data and realizing independent development of the upper machine and the lower machine, the final knitting control data not only have low computation and transmission cost but also have fast transfer speeds. 展开更多
关键词 fully-fashioned knitting computerized flat knitting machine CAD ANALYZING COMPILING
在线阅读 下载PDF
COMPUTERIZED PREDICTION OF INTERACTION PARAMETERSAND PHASE DIAGRAMS OF CONTINUOUS SOLID SOLUTION OFBINARY ALLOY SYSTEMS
7
作者 J. Guo (Department of Physics, Guangxi University, Nanning 530004, China) 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1999年第3期216-220,共5页
The artificial neural network method has been applied to the relationship between the atomic parameters and intemction packeters of binary alloy Phases, and the principle of thermodynamics in combination with artifici... The artificial neural network method has been applied to the relationship between the atomic parameters and intemction packeters of binary alloy Phases, and the principle of thermodynamics in combination with artificial neural network method has been used for the computerized phase diagrams of continuous solid solution of bigamy alloy systems. The computerized phase diagrams well agree with the real phase diagmms. 展开更多
关键词 antificial neural network interaction parameter computerized phase diagram
在线阅读 下载PDF
Computerized cognitive behavioral therapy with sertraline in schizophrenia with depressive episodes: A 12-week randomized controlled trial
8
作者 Ren-Chun Huang Nicha Wareesawetsuwan +1 位作者 Nan Lin Xiao-Dan Li 《World Journal of Psychiatry》 2025年第11期357-366,共10页
BACKGROUND Schizophrenia is commonly associated with comorbid depression,which exacerbates cognitive impairments and negatively impacts quality of life.Despite the high prevalence and burden of these comorbidities,eff... BACKGROUND Schizophrenia is commonly associated with comorbid depression,which exacerbates cognitive impairments and negatively impacts quality of life.Despite the high prevalence and burden of these comorbidities,effective treatment options,particularly for cognitive dysfunction,remain limited.AIM To evaluate the efficacy of computerized cognitive behavioral therapy(CCBT)with sertraline vs sertraline monotherapy in improving depressive symptoms,cognitive function,and quality of life in schizophrenia and depressive episodes.METHODS In this single-center,randomized controlled trial,68 adults[mean age(SD)=36.5(10.0),57.4%male]with schizophrenia and depressive symptoms were randomly assigned to receive either CCBT with sertraline or sertraline monotherapy during a 4-week hospitalization.The CCBT intervention involved 45-60-minute sessions twice weekly for four weeks.Outcomes included comparisons of depressive symptoms(Calgary depression scale for schizophrenia),cognitive function[MATRICS consensus cognitive battery(MCCB)],and quality of life(36-item short form survey)between the groups.RESULTS The experimental group showed greater improvements in depressive symptoms at 4,8,and 12 weeks compared to the controls,with the most notable difference at 12 weeks[mean difference(MD)=-1.7;P<0.001;Cohen’s d=0.9].Cognitive function improved across all MCCB domains in the experimental group,with higher processing speed scores(MD=4.1;P=0.043;Cohen’s d=0.5)and social cognition scores(MD=4.9;P=0.006;Cohen’s d=0.7)than in the control group.Quality of life,particularly in mental health,was significantly better in the experimental group.CONCLUSION CCBT with sertraline was more effective than sertraline monotherapy for patients with schizophrenia and depressive episodes,supporting its use as an adjunctive therapy. 展开更多
关键词 Schizophrenia with depressive episode computerized cognitive behavioral therapy SERTRALINE Cognitive function Quality of life Randomized controlled trial
暂未订购
COMPUTERIZED SIMULATION AND EXPERIMENTAL RESEARCH ON SOFT-SWITCHING ARC WELDING INVERTER POWER SOURCE 被引量:24
9
作者 S. J. Chen S. Y. Yin L. Feng and L. Y. Li( 1) School of Materials Science and Engineering, Beijing Polytechnic University, Beijing 100022, China 2)National Key Laboratory of Advanced Welding Production Technology, HIT, Harbin 150001, China) 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2000年第1期128-132,共5页
Based on the existing component models in the Pspice software package, a combined model for Insulat- ed the Bipolar Transistor (IGBT) is established, in which a non - linear is introduced to represent the parasitic ... Based on the existing component models in the Pspice software package, a combined model for Insulat- ed the Bipolar Transistor (IGBT) is established, in which a non - linear is introduced to represent the parasitic capacitance. Using this model, computerized simulation is conducted for the FB - ZVZCS - PWM soft - ewitching converter,the switching and energy-transferring characteristics of the components are analyzed.The simulation results are testified by experiments.It is proved that by abopting appropriate models,computerized simulation becomes an effective tool for investigation of arc welding inverter power source. 展开更多
关键词 arc welding inverter computerized simulation.IGBT soft switching
在线阅读 下载PDF
Peripancreatic collections in acute pancreatitis: Correlation between computerized tomography and operative fi ndings 被引量:5
10
作者 Santhi Swaroop Vege Joel G Fletcher +1 位作者 Rupjyoti Talukdar Michael G Sarr 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第34期4291-4296,共6页
AIM: To evaluate the ability of contrast-enhanced computerized tomography (CECT) to characterize the nature of peripancreatic collections.METHODS: Twenty five patients with peripancreatic collections on CECT and who u... AIM: To evaluate the ability of contrast-enhanced computerized tomography (CECT) to characterize the nature of peripancreatic collections.METHODS: Twenty five patients with peripancreatic collections on CECT and who underwent operative intervention for severe acute pancreatitis were retrospectively studied. The collections were classified into (1) necrosis without frank pus; (2) necrosis with pus; and (3) fluid without necrosis. A blinded radiologist assessed the preoperative CTs of each patient for necrosis and peripancreatic fluid collections. Peripancreatic collections were described in terms of volume, location, number, heterogeneity, fluid attenuation, wall perceptibility, wall enhancement, presence of extraluminal gas, and vascular compromise.RESULTS: Fifty-four collections were identif ied at operation, of which 45 (83%) were identif ied on CECT. Of these, 25/26 (96%) had necrosis without pus, 16/19 (84%) had necrosis with pus, and 4/9 (44%) had fluid without necrosis. Among the study characteristics, fluid heterogeneity was seen in a greater proportion of collections in the group with necrosis and pus, compared to the other two groups (94% vs 48% and 25%, P = 0.002 and 0.003, respectively). Among the wall characteristics, irregularity was seen in a greater proportion of collections in the groups with necrosis with and without pus, when compared to the group with fluid without necrosis (88% and 71% vs 25%, P = 0.06 and P < 0.01, respectively). The combination of heterogeneity and presence of extraluminal gas had a specif icity and positive likelihood ratio of 92% and 5.9, respectively, in detecting pus. CONCLUSION: Most of the peripancreatic collections seen on CECT in patients with severe acute pancreatitis who require operative intervention contain necrotic tissue. CECT has a somewhat limited role in differentiating the different types of collections. 展开更多
关键词 Contrastenhanced computerized tomogra-phy CORRELATION Pancreatic necrosis PANCREATITIS Peripancreatic fluid collection Surgery
暂未订购
Identification of Porphyra lines using computerized DNA fingerprinting 被引量:7
11
作者 WangBin, Jia Jianhang, Shi Jinfeng, Chen Yihua, JinDemin, Xu Pu, Mei Junxue, Weng Manli 1. Institute of Genetics, Chinese Academy of Sciences, Beijing 100101 (E-mail: mlweng@genetics. ac. cn), China 2. Jiangsu Marine Fishery Institute, Nan 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2001年第3期401-407,共7页
RAPD (Randomly Amplified Polymorphic DNA) analysis was performed with filaments of 15 Porphyra lines representing four important groups (P. yezoensis, P. haitanensis, P. katadai var. Hemiphylla and P. digospermatangia... RAPD (Randomly Amplified Polymorphic DNA) analysis was performed with filaments of 15 Porphyra lines representing four important groups (P. yezoensis, P. haitanensis, P. katadai var. Hemiphylla and P. digospermatangia). Eight stable and repeatable RAPD bands amplified with two primers, OPN-02 and OPJ-18, were selected for the construction of DNA fingerprinting. The RAPD results were scored based on the presence or absence of each of the 8 bands and then converted to computer language expressed with two digitals, 1 and 0, which represented the presence (numbered as 1) or absence (numbered as 0) of each band, respectively. Based on these results, a model DNA fingerprint and a computerized DNA fingerprint were constructed. In the constructed DNA fingerprint, each Porphyra line has its unique fingerprinting pattern and can be easily distinguished from each other. Later, a software, named as PhGI, was designed based on this DNA fingerprinting. It can be used in practical Porphyra line identification. 展开更多
关键词 computerized DNA fingerprinting RAPD Porphyra germplasm identification
在线阅读 下载PDF
Adult reference values of the computerized diplopia test 被引量:8
12
作者 Ling-Yun Zhou Tie-Juan Liu Xue-Mei Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第11期1646-1650,共5页
AIM: To estimate the adult reference values for measured deviations by a computerized diplopia test and testify the validity.METHODS: Totally 391 participants were recruited and taken the computerized diplopia test.... AIM: To estimate the adult reference values for measured deviations by a computerized diplopia test and testify the validity.METHODS: Totally 391 participants were recruited and taken the computerized diplopia test. The plots and amplitude of deviations were recorded. The differences in different gender, age and visual acuity groups were analyzed respectively. Of 30 subjects were enrolled to testify the interobserver reliability. Another 46 subjects(including 26 normal subjects and 20 patients) were taken the test and theirs deviations were recorded to testify the validity of the reference value.RESULTS: The max horizontal and vertical deviations were 2.55° and 0.76° with normal corrected visual acuity while 3.88° and 1.46° for subjects with poor corrected vision. The differences between age groups was insignificant(Z =3.615, 4.758; P =0.461, 0.313 for horizontal and vertical respectively). The max horizontal deviation of female was smaller than male(Z =-2.177; P =0.029),but the difference in max vertical deviation was insignificant(Z =-1.296; P =0.195). The mean difference between observers were both-0.1°, with 95% confidence limits(CI) of-1.4° and 1.6° in max horizontal deviations while-2.1° and 1.8° in max vertical deviation. The mean deviation of 26 normal subjects was 1.02° ±0.84° for horizontal and 0.47° ±0.30° for vertical which both within the range of reference values. The mean deviation of 20 patients was 13.51°±11.69° for horizontal and 8.34°±8.58°for vertical which both beyond the reference range.CONCLUSION: The max amplitude of horizontal and vertical deviation is pointed as the numerical parameters of computerized diplopia test. The reference values are different between normal corrected visual acuity and poor corrected vision. These values may useful for evaluating patients with diplopia in veriety conditions during clinical practice. 展开更多
关键词 computerized diplopia test referencevalues amplitude of deviations
原文传递
Positron emission tomography/computerized tomography in the evaluation of primary non-Hodgkin's lymphoma of prostate 被引量:4
13
作者 Bo Pan Jian-Kui Han +1 位作者 Shi-Cun Wang Ao Xu 《World Journal of Gastroenterology》 SCIE CAS 2013年第39期6699-6702,共4页
Primary malignant lymphoma of the prostate is exceedingly rare.Here we report a case of a 65-year-old man who presented with increased urinary frequency,urinary urgency,and urinary incontinence for two years.Benign pr... Primary malignant lymphoma of the prostate is exceedingly rare.Here we report a case of a 65-year-old man who presented with increased urinary frequency,urinary urgency,and urinary incontinence for two years.Benign prostatic hypertrophy was suspected at primary impression.Ultrasound revealed a hypoechoic lesion of the prostate.The total serum prostate-specific antigen was within normal range.Positron emission tomography/computerized tomography(PET/CT)showed a hypermetabolic prostatic lesion.Prostate biopsy was consistent with a non-germinal center diffuse large B cell lymphoma.There was complete remission of the prostatic lesion following six cycles of chemotherapy as shown on the second PET/CT imaging.18F-fluoro-deoxy glucose PET/CT is not only a complement to conventional imaging,but also plays a significant role in the diagnosis and evaluation of treatment response of prostatic lymphoma. 展开更多
关键词 Fluoro-Deoxy-Glucose Positron emission tomography/computerized tomography Non-Hodgkin’s LYMPHOMA PROSTATIC LYMPHOMA EVALUATION
暂未订购
Pore structure of ore granular media by computerized tomography image processing 被引量:6
14
作者 吴爱祥 杨保华 +1 位作者 习泳 江怀春 《Journal of Central South University of Technology》 EI 2007年第2期220-224,共5页
The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the ... The pore structure images of ore particles located at different heights of leaching column were scanned with X-ray computerized tomography (CT) scanner, the porosity and pore size distribution were calculated and the geometrical shape and connectivity of pores were analyzed based on image process method, and the three dimensional reconstruction of pore structure images was realized. The results show that the porosity of ore particles bed in leaching column is 42.92%, 41.72%, 39.34% at top, middle and bottom zone, respectively. Obviously it has spatial variability and decreases appreciably along the height of the column. The overall average porosity obtained by image processing is 41.33% while the porosity gotten from general measurement method in laboratory is 42.77% showing the results of both methods are consistent well. The pore structure of ore granular media is characterized as a dynamical space network composed of interconnected pore bodies and pore throats. The ratio of throats with equivalent diameter less than 1.91 mm to the total pores is 29.31%, and that of the large pores with equivalent diameter more than 5.73 mm is 2.90%. 展开更多
关键词 ore granular media pore structure X-ray computerized tomography image processing
在线阅读 下载PDF
Rock joint coefficients and their computerized classification 被引量:3
15
作者 Tomás Ficker 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2019年第5期701-709,共9页
A computerized method for determining rock joint coefficients is presented.Two relative similarity indicators are introduced to classify surface morphology of rock joints.The classification enables to compare investig... A computerized method for determining rock joint coefficients is presented.Two relative similarity indicators are introduced to classify surface morphology of rock joints.The classification enables to compare investigated and database rock joints.Such a comparison aims at finding the couple of surfaces that are distinguished by the highest dynamical conformity.The first absolute indicator results from the Fourier matrix and evaluates wavy shapes of surfaces.The second absolute indicator quantifies the heights of surface reliefs and is defined as the root mean square height of the surface outline.Numerical reliability of these indicators is tested within the surface analysis of a series of limestone specimens.Besides the computerized assessment,25 people have performed visual assessment of these limestone specimens.The results of visual assessments have been statistically processed and compared to the results received from the computerized procedure.The newly introduced absolute indicators have proved to be prospective numerical tools for evaluating joint rock coefficients. 展开更多
关键词 Rock joints Shear strength Joint rock coefficients Numerical indicators computerized assessment
在线阅读 下载PDF
Application of Proton Magnetic Resonance Spectroscopy and Computerized Tomography in the Diagnosis and Treatment of Nonalcoholic Fatty Liver Disease 被引量:4
16
作者 王南 董慧 +1 位作者 魏世超 陆付耳 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2008年第3期295-298,共4页
In order to investigate the application of proton magnetic resonance spectroscopy (ill-MRS) and computerized tomography (CT) in the quantitative diagnosis of nonalcoholic fatty liver disease (NAFLD) and evaluati... In order to investigate the application of proton magnetic resonance spectroscopy (ill-MRS) and computerized tomography (CT) in the quantitative diagnosis of nonalcoholic fatty liver disease (NAFLD) and evaluation of therapeutic effects, 22 patients with NAFLD were selected according to the Chinese Medical Association's (CMA) standard of the NAFLD in comparison with 20 healthy volunteers (as control group). Blood samples for biochemistry were collected. The severity of hepatosteatosis was evaluated by ^1H-MRS scan and CT scan of liver. The intrahepatic content of lipid (IHCL) and CT value ratio of liver to spleen were calculated. The patients in NAFLD group were treated with Ganzhixiao Capsule for 8 weeks. The changes in IHCL and CT value ratio of liver to spleen were observed before and after treatment. In NAFLD group serum ALT, TG, IHCL calculated by ^1HMRS were increased and CT value ratio of liver to spleen decreased significantly as compared with control group. After treatment for 8 weeks serum ALT, TG, IHCL were decreased significantly, while CT value ratio of liver to spleen increased significantly in NAFLD group. It was suggested that IHCL could be measured precisely by ^1HMRS. NAFLD was treated effectively by Ganzhixiao capsule. 展开更多
关键词 proton magnetic resonance spectroscopy computerized tomography nonalcoholic fatty liver disease
暂未订购
Computerized cognitive remediation therapy on cognitive impairment and social function in patients with chronic schizophrenia 被引量:3
17
作者 Jian-Jun Hu Xi-Rong Sun +1 位作者 Shuang-Ming Ni Yan Kong 《World Journal of Psychiatry》 SCIE 2024年第6期884-893,共10页
BACKGROUND Patients with schizophrenia may have various disease manifestations,most of which gradually tend toward incurable chronic decline,leading to mental disability.The basic symptoms of the disease can impair so... BACKGROUND Patients with schizophrenia may have various disease manifestations,most of which gradually tend toward incurable chronic decline,leading to mental disability.The basic symptoms of the disease can impair social function,whereas long-term hospitalization produces hospitalization syndrome,causing serious damage to social function.AIM To investigate the effects of Computerized Cognitive Remediation Therapy(CCRT)on cognitive and social functioning in patients with chronic schizophrenia.METHODS A retrospective analysis of 120 patients with chronic schizophrenia in Shanghai Pudong New Area Mental Health Center was performed.They were divided into an intervention group(60 cases treated with CCRT combined with conventional medication)and a control group(60 cases treated with conventional medication).After treatment,effects on cognitive function and social roles were observed in both groups.The Positive and Negative Syndrome Scale(PANSS)was used to assess the patients'psychiatric symptoms.The Wisconsin Card Sorting Test(WCST)was used to assess the patients'cognitive functioning,and the Social Functioning Scale for Psychiatric Inpatients(SSPI)was used to assess the social functioning of the inpatient psychiatric patients.RESULTS No significant differences were observed in the PANSS,WCST,and SSPI intergroup scores before treatment(P>0.05).After 2,4,and 6 wk of therapy,general psychopathological factors,positive symptoms,negative symptoms,and total PANSS scores of PANSS in the intervention group were lower than in the control group(P<0.05).After 2,4,and 6 wk of treatment,the number of false responses,number of persistent bugs,and total responses in the WCST were significantly lower in the intervention group than in the control group(P<0.05),and the amount of completed classification was significantly higher than in the control group(P<0.05).After 2,4,and 6 wk of therapy,the SSPI scores were significantly greater than those of the controls(P<0.05).After 6 wk of treatment,the efficacy rates of the control and intervention groups were 81.67%and 91.67%,respectively.The curative effect in the intervention group was significantly higher than that in the control group(P<0.05).CONCLUSION CCRT can significantly improve cognitive function and social abilities in patients with chronic schizophrenia. 展开更多
关键词 computerized cognitive correction therapy SCHIZOPHRENIA Cognitive function Social function Psychopathological factors
暂未订购
The Clinical Application of Computerized Three-Dimensional Mimic Operation for Maxillofacial Bone Tumor 被引量:2
18
作者 陶学金 殷孝蓉 +1 位作者 朱芳 陈卫民 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1999年第4期328-330,共3页
Facial bone, as the frame to support maxillofacial region and with several sinuses and cavities, is structurally complicated and the maxillofacial tumors,benign or malignant, in this region usually grows into the deep... Facial bone, as the frame to support maxillofacial region and with several sinuses and cavities, is structurally complicated and the maxillofacial tumors,benign or malignant, in this region usually grows into the deep tissues, sinus-cav-ities and orbit and destroys the bone. In this study, the maxillofacial tumors were subjected to a mimic operation on a computer following CT scanning and 3-dimen-sional reconstruction. The data similar to those of real operation were obtained,which could be used for developing operative plans. As compared with data on the basis of conditions in the real operation, computerized mimic operation reflected the real conditions during operation. Computerized mimic operation is valuable for the preoperative planning and the prediction of probable intraoperative events. 展开更多
关键词 maxillofacia tumor computerized mimic operation computed tomography
暂未订购
Preliminary observation results of the Coherent Beacon Systemonboard the China Seismo-Electromagnetic Satellite-1 被引量:4
19
作者 Liang Chen Ming Ou +3 位作者 YaPing Yuan Fang Sun Xiao Yu WeiMin Zhen 《Earth and Planetary Physics》 2018年第6期505-514,共10页
This paper reports, for the first time, observation results of the Coherent Beacon System(CBS) onboard the China SeismoElectromagnetic Satellite-1(CSES-1). We describe the CBS, and the Computerized Ionospheric Tomogra... This paper reports, for the first time, observation results of the Coherent Beacon System(CBS) onboard the China SeismoElectromagnetic Satellite-1(CSES-1). We describe the CBS, and the Computerized Ionospheric Tomography(CIT) algorithm program is validated by numerical experiment. Two examples are shown, for daytime and nighttime respectively. The Equatorial Ionization Anomaly(EIA) can be seen, and the northern crest core is located at ~20°N in the reconstruction image at 07:28 UTC on 20 July 2018(daytime).Disturbances are shown in the reconstruction image at 18:40 UTC on 13 July 2018(nighttime). We find that beacon measurements are more consistent with ionosonde measurements than model results, by comparing Nm F2 at three sites at Lanzhou, Chongqing, and Kunming; consistency with ionosonde measurements validates beacon measurements. Finally, we have studied Vertical Total Electron Content(VTEC) variations from ground to ~500 km(the height of CSES-1 orbit) and ratios of VTEC between beacon measurements and CODE(Center for Orbit Determination in Europe) data. VTEC variation from ground to ~500 km has a range of 7.2–16.5 TECU for the daytime case and a range of 1.1–1.7 TECU for the nighttime case. The Beacon/CODE ratio of VTEC varies with latitude and time. The mean Beacon/CODE ratio is 0.69 for the daytime case and 0.26 for the nighttime case. The fact that the nighttime case yields lower ratios indicates the higher altitude of the ionosphere during nighttime when the ionosphere is assumed to be a thin layer. 展开更多
关键词 Coherent Beacon system(CBS) China Seismo-Electromagnetic Satellite-1(CSES-1) computerized Ionospheric Tomography(CIT) Total Electron Content(TEC)
在线阅读 下载PDF
Comments on the article about correlation between computerized tomography and surgery in acute pancreatitis 被引量:1
20
作者 Enver Zerem Goran Imamovi +1 位作者 Zoran Mavija Bahrija Harai 《World Journal of Gastroenterology》 SCIE CAS CSCD 2011年第3期407-408,共2页
We read with great interest the article by Vege et al published in issue 34 of World J Gastroenterol 2010. The article evaluates the ability of contrast-enhanced computerized tomography (CECT) to characterize the natu... We read with great interest the article by Vege et al published in issue 34 of World J Gastroenterol 2010. The article evaluates the ability of contrast-enhanced computerized tomography (CECT) to characterize the nature of peripancreatic collections found at surgery. The results of their study indicate that most of the peripancreatic collections seen on CECT in patients with severe acute pancreatitis who require operative intervention contain necrotic tissue and CECT has a limited role in differentiating various types of collections. However, there are some points that need to be addressed, including data about the stage of acute pancreatitis in which CECT was done and the time span between CECT examination and surgery. 展开更多
关键词 Acute pancreatitis Pancreatic necrosis Peripancreatic fluid collection Contrast-enhanced computerized tomography SURGERY
暂未订购
上一页 1 2 12 下一页 到第
使用帮助 返回顶部