This paper presents the aspirated modification of a dual-stage counter-rotating compressor which contains inlet guide vanes(IGVs), two counter-rotating rotors(R1, R2), and outlet guide vanes(OGVs).Uniform circul...This paper presents the aspirated modification of a dual-stage counter-rotating compressor which contains inlet guide vanes(IGVs), two counter-rotating rotors(R1, R2), and outlet guide vanes(OGVs).Uniform circular holes are circumferentially distributed over the rotors' tips on the shroud casing which are designed to remove the low-energy fluid near the shroud casing.OGVs are hollow blades with two slots designed on the suction side which can better control the flow on the suction surface through boundary layer suction.Related works about the experiments have been carried out since June 2012 and the effect of flow suction on the performance of the compressor is investigated in detail.Characteristic lines at a 70% corrected rotating speed are tested and those with higher rotating speeds will be studied in the near future.Experimental results indicate that boundary layer suction can improve the compressor characteristics and the best suction methodology varies along the operating line.At the near stall condition, suction from the R2 tip region can obviously increase the efficiency and the total pressure ratio, as well as improve the flow capacity.Isentropic efficiency can be maximally increased by 4.24% with an increase of 1.94% in massflow under a suction flow of 160 m3/h.Suction at the R1 position with a suction rate below 0.35% in a high flow situation can make the performance of the compressor better than others.Around the peak efficiency point, boundary layer suction from the slots of OGVs is the best choice in improving the efficiency, but it causes a 0.1% loss in the total pressure ratio.展开更多
The impact of boundary layer suction on the aerodynamic performance of a high-turning compressor cascade was numerically simulated and discussed.The aerodynamic performance of a curved and a straight cascade with and ...The impact of boundary layer suction on the aerodynamic performance of a high-turning compressor cascade was numerically simulated and discussed.The aerodynamic performance of a curved and a straight cascade with and without boundary layer suction were comparatively studied at several suction flow rates.The results showed that boundary layer suction dramatically improved the flow behavior within the flow passage.Moreover,higher loading over the whole blade height,lower total pressure loss,and higher passage throughflow were achieved with a relatively small amount of boundary layer removal.The integration of curved blade and boundary layer suction contributed to better aerodynamic performance than the cascades with only curved blade or boundary layer suction used,and the more favorable effect resulted from the weakening of the three dimensional effects of the boundary layer close to the endwalls.展开更多
In the current study, the effects of a combined application between micro-vortex generator and boundary layer suction on the flow characteristics of a high-load compressor cascade are investigated. The micro-vortex ge...In the current study, the effects of a combined application between micro-vortex generator and boundary layer suction on the flow characteristics of a high-load compressor cascade are investigated. The micro-vortex generator with a special configuration and the longitudinal suction slot are adopted. The calculated results show that a reverse flow region, which is considered the main reason for occurring stall at 7.9° incidence, grows and collapses rapidly near the leading edge and leads to two critical points occurring on the end-wall with the increasing incidence in the baseline. As the micro-vortex generator is introduced in the baseline cascade, the corner separation is switched to a trailing edge separation by the thrust from the induced vortex. Meanwhile, the occurrence of failure is delayed due to the mixed low energy fluid and main flow. The synergistic effects between the micro-vortex generator and the boundary layer suction on the performance of the cascade are superior to the baseline at all the incidence conditions before the occurrence of failure, and the sudden deterioration of the cascade occurs at 10.3° incidence. The optimal results show that the farther upstream suction position, the lower total pressure loss of the cascade with vortex generator at the near stall condition. Moreover, the induced vortex with a leg can migrate the accumulated low energy fluid backward to delay the occurrence of stall.展开更多
There is introduced a new low-reaction, highly-loaded axial compressor design concept which is coupled with boundary layer suction method. The characteristic features of the concept are made clear through its comparis...There is introduced a new low-reaction, highly-loaded axial compressor design concept which is coupled with boundary layer suction method. The characteristic features of the concept are made clear through its comparison with the MIT boundary layer suction compressor. Also are pointed out the potential applications of this concept as well as its key technological problems. Based on this concept, a single-stage, low-reaction and low-speed axial compressor is constructed in association with analysis and computation of boundary layer suction on vanes with the aid of a three-dimensional numerical approach. The results attest to the effectiveness of this way to control separation in blade cascades by the boundary layer suction and the feasibility of this proposed design concept.展开更多
通过数学模型的建立与求解,分析吸气预处理涉及的压缩机吸气温度、含湿量和压力对压缩机能耗、比功率以及输气量的影响规律,旨在为吸气预处理换热器的设计提供理论依据。研究结果表明:当吸气温度每降低1℃,空压机比功率降低0.06 k W/(m^...通过数学模型的建立与求解,分析吸气预处理涉及的压缩机吸气温度、含湿量和压力对压缩机能耗、比功率以及输气量的影响规律,旨在为吸气预处理换热器的设计提供理论依据。研究结果表明:当吸气温度每降低1℃,空压机比功率降低0.06 k W/(m^(3)/min),输气量升高0.182 m^(3)/min;吸气含湿量对空压机比功率的影响与吸气温度相当,但除去每克水蒸气所需冷能约是空气单位温降的2.4倍;吸气压力每降低1 k Pa可抵消约2.67℃吸气温降带来的节能效果;因此吸气预处理换热器冷源温度不宜低于空气露点温度,需通过合理的结构设计降低吸气预处理导致的压力损失。展开更多
Based on the investigation of mid-span local boundary layer suction and positive bowed cascade, a coupled local tailored boundary layer suction and positive bowed blade method is developed to improve the performance o...Based on the investigation of mid-span local boundary layer suction and positive bowed cascade, a coupled local tailored boundary layer suction and positive bowed blade method is developed to improve the performance of a highly loaded diffusion cascade with less suction slot. The effectiveness of the coupled method under different inlet boundary layers is also investigated.Results show that mid-span local boundary layer suction can effectively remove trailing edge separation, but deteriorate the flow fields near the endwall. The positive bowed cascade is beneficial for reducing open corner separation, but is detrimental to mid-span flow fields. The coupled method can further improve the performance and flow field of the cascade. The mid-span trailing edge separation and open corner separation are eliminated. Compared with linear cascade with suction, the coupled method reduces overall loss of the cascade by 31.4% at most. The mid-span loss of the cascade decreases as the suction coefficient increases, but increases as bow angle increases. The endwall loss increases as the suction coefficient increases. By contrast, the endwall loss decreases significantly as the bow angle increases. The endwall loss of coupled controlled cascade is higher than that of bowed cascade with the same bow angle because of the spanwise inverse ‘‘C" shaped static pressure distribution. Under different inlet boundary layer conditions, the coupled method can also improve the cascade effectively.展开更多
As a reliability quantitative specification, parametric accelerated life testing was used to assess the reliability of a newly designed compressor of a commercial refrigerator subjected to repetitive stresses. A gener...As a reliability quantitative specification, parametric accelerated life testing was used to assess the reliability of a newly designed compressor of a commercial refrigerator subjected to repetitive stresses. A generalized life-stress failure model and new sample size equation with a new load concept were derived starting with the basic refrigeration cycle. The sample size equation with the acceleration factor also enabled the parametric accelerated life testing to quickly evaluate the expected lifetime. The design of this testing should help an engineer uncover the design parameters affecting reliability during the design process of the compressor system. Consequently, it should help companies improve product reliability and avoid recalls due to the product failures in the field. A newly designed compressor in a commercial refrigerator was used as a test case.展开更多
基金supported by the National Natural Science Foundation of China (No.51236006)Advanced Aeroengine Collaborative Innovation Center
文摘This paper presents the aspirated modification of a dual-stage counter-rotating compressor which contains inlet guide vanes(IGVs), two counter-rotating rotors(R1, R2), and outlet guide vanes(OGVs).Uniform circular holes are circumferentially distributed over the rotors' tips on the shroud casing which are designed to remove the low-energy fluid near the shroud casing.OGVs are hollow blades with two slots designed on the suction side which can better control the flow on the suction surface through boundary layer suction.Related works about the experiments have been carried out since June 2012 and the effect of flow suction on the performance of the compressor is investigated in detail.Characteristic lines at a 70% corrected rotating speed are tested and those with higher rotating speeds will be studied in the near future.Experimental results indicate that boundary layer suction can improve the compressor characteristics and the best suction methodology varies along the operating line.At the near stall condition, suction from the R2 tip region can obviously increase the efficiency and the total pressure ratio, as well as improve the flow capacity.Isentropic efficiency can be maximally increased by 4.24% with an increase of 1.94% in massflow under a suction flow of 160 m3/h.Suction at the R1 position with a suction rate below 0.35% in a high flow situation can make the performance of the compressor better than others.Around the peak efficiency point, boundary layer suction from the slots of OGVs is the best choice in improving the efficiency, but it causes a 0.1% loss in the total pressure ratio.
基金Sponsored by the National Natural Science Foundation of China(Grant No.50646021).
文摘The impact of boundary layer suction on the aerodynamic performance of a high-turning compressor cascade was numerically simulated and discussed.The aerodynamic performance of a curved and a straight cascade with and without boundary layer suction were comparatively studied at several suction flow rates.The results showed that boundary layer suction dramatically improved the flow behavior within the flow passage.Moreover,higher loading over the whole blade height,lower total pressure loss,and higher passage throughflow were achieved with a relatively small amount of boundary layer removal.The integration of curved blade and boundary layer suction contributed to better aerodynamic performance than the cascades with only curved blade or boundary layer suction used,and the more favorable effect resulted from the weakening of the three dimensional effects of the boundary layer close to the endwalls.
基金co-supported by the National Natural Science Foundation of China(Grants Nos.51576162 and 51536006)
文摘In the current study, the effects of a combined application between micro-vortex generator and boundary layer suction on the flow characteristics of a high-load compressor cascade are investigated. The micro-vortex generator with a special configuration and the longitudinal suction slot are adopted. The calculated results show that a reverse flow region, which is considered the main reason for occurring stall at 7.9° incidence, grows and collapses rapidly near the leading edge and leads to two critical points occurring on the end-wall with the increasing incidence in the baseline. As the micro-vortex generator is introduced in the baseline cascade, the corner separation is switched to a trailing edge separation by the thrust from the induced vortex. Meanwhile, the occurrence of failure is delayed due to the mixed low energy fluid and main flow. The synergistic effects between the micro-vortex generator and the boundary layer suction on the performance of the cascade are superior to the baseline at all the incidence conditions before the occurrence of failure, and the sudden deterioration of the cascade occurs at 10.3° incidence. The optimal results show that the farther upstream suction position, the lower total pressure loss of the cascade with vortex generator at the near stall condition. Moreover, the induced vortex with a leg can migrate the accumulated low energy fluid backward to delay the occurrence of stall.
基金National Defense Basic Research Program of China
文摘There is introduced a new low-reaction, highly-loaded axial compressor design concept which is coupled with boundary layer suction method. The characteristic features of the concept are made clear through its comparison with the MIT boundary layer suction compressor. Also are pointed out the potential applications of this concept as well as its key technological problems. Based on this concept, a single-stage, low-reaction and low-speed axial compressor is constructed in association with analysis and computation of boundary layer suction on vanes with the aid of a three-dimensional numerical approach. The results attest to the effectiveness of this way to control separation in blade cascades by the boundary layer suction and the feasibility of this proposed design concept.
文摘通过数学模型的建立与求解,分析吸气预处理涉及的压缩机吸气温度、含湿量和压力对压缩机能耗、比功率以及输气量的影响规律,旨在为吸气预处理换热器的设计提供理论依据。研究结果表明:当吸气温度每降低1℃,空压机比功率降低0.06 k W/(m^(3)/min),输气量升高0.182 m^(3)/min;吸气含湿量对空压机比功率的影响与吸气温度相当,但除去每克水蒸气所需冷能约是空气单位温降的2.4倍;吸气压力每降低1 k Pa可抵消约2.67℃吸气温降带来的节能效果;因此吸气预处理换热器冷源温度不宜低于空气露点温度,需通过合理的结构设计降低吸气预处理导致的压力损失。
基金supported by China Postdoctoral Science Foundationa key project of the National Natural Science Foundation of China (No. 51236006)
文摘Based on the investigation of mid-span local boundary layer suction and positive bowed cascade, a coupled local tailored boundary layer suction and positive bowed blade method is developed to improve the performance of a highly loaded diffusion cascade with less suction slot. The effectiveness of the coupled method under different inlet boundary layers is also investigated.Results show that mid-span local boundary layer suction can effectively remove trailing edge separation, but deteriorate the flow fields near the endwall. The positive bowed cascade is beneficial for reducing open corner separation, but is detrimental to mid-span flow fields. The coupled method can further improve the performance and flow field of the cascade. The mid-span trailing edge separation and open corner separation are eliminated. Compared with linear cascade with suction, the coupled method reduces overall loss of the cascade by 31.4% at most. The mid-span loss of the cascade decreases as the suction coefficient increases, but increases as bow angle increases. The endwall loss increases as the suction coefficient increases. By contrast, the endwall loss decreases significantly as the bow angle increases. The endwall loss of coupled controlled cascade is higher than that of bowed cascade with the same bow angle because of the spanwise inverse ‘‘C" shaped static pressure distribution. Under different inlet boundary layer conditions, the coupled method can also improve the cascade effectively.
文摘As a reliability quantitative specification, parametric accelerated life testing was used to assess the reliability of a newly designed compressor of a commercial refrigerator subjected to repetitive stresses. A generalized life-stress failure model and new sample size equation with a new load concept were derived starting with the basic refrigeration cycle. The sample size equation with the acceleration factor also enabled the parametric accelerated life testing to quickly evaluate the expected lifetime. The design of this testing should help an engineer uncover the design parameters affecting reliability during the design process of the compressor system. Consequently, it should help companies improve product reliability and avoid recalls due to the product failures in the field. A newly designed compressor in a commercial refrigerator was used as a test case.