Aiming at the application of a wireless sensor network to locating miners in underground mine,we design a wireless sensor network location node system,considering the communication performance and the intrinsic safety...Aiming at the application of a wireless sensor network to locating miners in underground mine,we design a wireless sensor network location node system,considering the communication performance and the intrinsic safety. The location node system consists of a mobile node,several fixed nodes,and a sink node,all of whose circuits were designed based on CC2430. A varistor and a RC circuit were used in the reset circuit of a sensor node to guarantee the intrinsic safety by reducing discharge energy,the theoretical analysis of the discharge energy shows that the reset circuit is an intrinsic safety one. The analysis and simulation about the performance of the location node system are discussed,such as network communication delay and packet loss rate,the results show that the highest network communication delay of the system is about 0.11 seconds,and the highest packet loss rate is about 0.13,which assures the location node system has a high reliability,and can locate miners in the underground mine.展开更多
The present study has been performed to understand the location of the virus, type of apoptotic cells, and their relation to lymph nodes of piglets infected with porcine circovirus type Ⅱ (PCV-2). Nine 32-day-old c...The present study has been performed to understand the location of the virus, type of apoptotic cells, and their relation to lymph nodes of piglets infected with porcine circovirus type Ⅱ (PCV-2). Nine 32-day-old conventional piglets free of infection with PCV-2 were used, and distributed into three groups: control group (n = 3), piglets inoculated with PCV-2 alone (PCV-2, n = 3), and PCV-2 inoculated and KLH immunostimulated group (PCV-2 + KLH, n = 3). Superficial inguinal lymph nodes from all piglets were collected for histological examination after 32 days postinoculation, and immunohistochemistry for PCV-2 detection. Location of apoptotic cells was detected with TdT-mediated dUTP nick end labeling (TUNEL) and cell cycle, and the apoptotic rates were measured by flow cytometry. The characteristic histopathological lesions of the piglets in PCV-2 and PCV-2 + KLH were lymphocyte depletions in the cortex and paracortex of the lymph nodes, epithelioid-like macrophage infiltration, and intracytoplasmic inclusion bodies presented in epithelioid-like macrophages. PCV-2 was mainly found in epithelioid-like macrophages by immunohistochemistry. In the lymph nodes, lymphocytes presented higher apoptotic rates in the cortex by TUNEL, special B-cell areas, and similar apoptotic cells were found in this compartment in the control. The apoptotic rates of the lymph nodes were 0.41, 3.34, and 4.88% in the control, PCV-2, and PCV-2 + KLH groups by flow cytometry, respectively. The apoptotic rates of lymph nodes for PCV-2 and PCV-2 + KLH piglets were significantly higher than those for the control group (P〈0.05 and P〈0.01). The proliferation index (PI) was 0.17_+0.01, 0.12_+0.01 and 0.12_+0.04 in the control, PCV-2, and PCV-2 + KLH group, the PI of the control group was higher than that of the other groups, but without the statistical difference. PCV-2 can induce lymphocyte depletion in lymph nodes of piglets by blocking cell proliferation and promoting apoptosis. This is one of the mechanisms of immunosuppression on infected piglets by PCV-2.展开更多
Objective: The presence of lymph node metastases is an important factor in the prognosis of gastric cancer patient. Therefore, the precise identification of sentinel lymph nodes (SLN) in these patients is critical....Objective: The presence of lymph node metastases is an important factor in the prognosis of gastric cancer patient. Therefore, the precise identification of sentinel lymph nodes (SLN) in these patients is critical. In this work, we investigated the feasibility and preciseness by injection of 99mTc-sulfur colloid (SC) 2 hours before operation after general anesthesia, instead of one day before surgery. Methods: Thirty-one patients of gastric cancer diagnosed as T1-T3 were enrolled in this study. During operation, a SLN was defined as those containing 10 times more radioactivity than surrounding tissue with a hand-held gamma probe and removed. All the patients underwent radical gastrectomy with extended lymphadenectomy. All resected nodes were examined postoperatively by routine H&E stain and those negative SLNs were examined with further cytokeratin immunohistochemistical staining. Results: The incidence of metastasis was significantly higher in SLNs than in non-SLNs (x2=67.48, P〈0.001). The overall sensitivity, specificity and accuracy of the SLN status in the diagnosis of the lymph node status of the patient were 86.36%, 100% and 96.77%, respectively. The positive predictive value and negative predictive value of SLN biopsy were 100%, and 75.0%, respectively. SLNs were used to diagnose the lymph node status with 100% accuracy in the T1 group. In the T2 and T3 groups, the sensitivity, specificity, and diagnostic accuracy were 92.3%, 100%, and 94.44%, 60.0%, 100%, and 66.66%, respectively. Most of the SLNs were located in the #1, #2, #3, #4, #5, and #6, except in 3 patients (9.68%).With cytokeratin immunohistochemical staining, lymphatic pathologic staging in 1 patient was upstaged. Conclusion: SLN biopsy with the above approach is a feasible and accurate diagnostic procedure for detecting lymph node metastasis in patients with gastric cancer, which is painless, noninvasive, easily accepted by patients and suitable for extensive clinical applications.展开更多
Objective: The aim of this study was to investigate Cathepsin-D (Cath-D) expression in different location and its relationship with prognosis in the axillary lymph nodes negative (ANN) breast cancer patients. Methods:...Objective: The aim of this study was to investigate Cathepsin-D (Cath-D) expression in different location and its relationship with prognosis in the axillary lymph nodes negative (ANN) breast cancer patients. Methods: Cath-D expression in 192 cases of breast carcinoma were examined by immunohistochemistry. Depending on different parts of expression, three evaluating methods were used, compared and analysed. Results: The positive rate of Cath-D expression in ANN breast cancer with poor prognosis group and axillary nodes positive (ANP) group were significantly higher than that in ANN breast cancer with good prognosis group (x 2=23.20,P<0.01), while there was no significant difference between ANP group and ANN with poor prognosis group (x 2=0.19,P>0.05). Cath-D expression in stromal cells had no statistical difference among the three groups (x}2=1.56,P>0.05). When the Cath-D expression in cancer and stromal cells were counted into the positive rate, it was near the same (u 1=0.47,u 2=1.41,P>0.05). Conclusion: These results suggest that Cath-D expression is one of the powerful prognostic markers in ANN breast cancer. It’s a reliable, practical, and convenient method to observe and evaluate Cath-D expression in cancer cells.展开更多
The thesis work was carried out in two phases. Firstly, we have designed the Cluster-Based Object Location Algorithm (CBOLA) for finding the object location in a cluster based network topology. Secondly, to take the a...The thesis work was carried out in two phases. Firstly, we have designed the Cluster-Based Object Location Algorithm (CBOLA) for finding the object location in a cluster based network topology. Secondly, to take the advantages of clustering architecture of Mobile Ad hoc Networks, we have especially designed Object Location Clusters Algorithm (OLCA) for efficient Object Location management in MANET. Our comparison of simulation analysis shows that the CBOLA is more efficient and accurate in location information services and more robust than GLS and HRLS. In addition, we believe that our comparative study with the various location services schemes was facilitated accurate results in ad hoc networks. we are portioned our network area by designing a new clustering algorithm called OLCA (Object Location Clusters Algorithm) for efficient object location in Mobile Ad hoc Networks. Simulation results and comparative analysis shows the performance and effectiveness of CBOLA and OLCA.展开更多
For mobile anchor node static path planning cannot accord the actual distribution of node for dynamic adjustment. We take advantage of the high localization accuracy and low computational complexity of ad-hoc localiza...For mobile anchor node static path planning cannot accord the actual distribution of node for dynamic adjustment. We take advantage of the high localization accuracy and low computational complexity of ad-hoc localization system( AHLos)algorithm. This article introduces mobile anchor nodes instead of the traditional fixed anchor nodes to improve the algorithm. The result shows that, through introduce the mobile anchor node, the information of initial anchor nodes can be configured more flexible.Meanwhile,with the use of the approximate location and the transition path,the distance and energy consumption of the mobile anchor node is greatly reduced.展开更多
Localization of the sensor nodes is a key supporting technology in wireless sensor networks (WSNs). In this paper, a real-time localization estimator of mobile node in WSNs based on extended Kalman filter (KF) is ...Localization of the sensor nodes is a key supporting technology in wireless sensor networks (WSNs). In this paper, a real-time localization estimator of mobile node in WSNs based on extended Kalman filter (KF) is proposed. Mobile node movement model is analyzed and online sequential iterative method is used to compute location result. The detailed steps of mobile sensor node self-localization adopting extended Kalman filter (EKF) is designed. The simulation results show that the accuracy of the localization estimator scheme designed is better than those of maximum likelihood estimation (MLE) and traditional KF algorithm.展开更多
The foundation of ad hoc networks lies in the guarantee of continuous connectivity.However,critical nodes,whose failure can easily destroy network connectivity,will influence the ad hoc network connectivity significan...The foundation of ad hoc networks lies in the guarantee of continuous connectivity.However,critical nodes,whose failure can easily destroy network connectivity,will influence the ad hoc network connectivity significantly.To protect the network efficiently,critical nodes should be identified accurately and rapidly.Unlike existing critical node identification methods for unknown topology that identify critical nodes according to historical information,this paper develops a critical node identification method to relax the prior topology information condition about critical nodes.Specifically,we first deduce a theorem about the minimum communication range for a node through the number of nodes and deployment ranges,and prove the universality of the theorem in a realistic two-dimensional scenario.After that,we analyze the relationship between communication range and degree value for each node and prove that the greater number of nodes within the communication range of a node,the greater degree value of nodes with high probability.Moreover,we develop a novel strategy to improve the accuracy of critical node identification without topology information.Finally,simulation results indicate the proposed strategy can achieve high accuracy and low redundancy while ensuring low time consumption in the scenarios with unknown topology information in ad hoc networks.展开更多
This paper, taking the distance between the piezoelectric ceramic center and the displacement node location of the transducer as a parameter, investigates the relation of characteristic parameters of transducer, such ...This paper, taking the distance between the piezoelectric ceramic center and the displacement node location of the transducer as a parameter, investigates the relation of characteristic parameters of transducer, such as force factor, equivalent resistance, potential maximum electroacoustical efficiency, and loading performance, to the displacement node location. Some design considerations about the selection of node location are noted .展开更多
基金Projects 20070411065 supported by the China Postdoctoral Science Foundation0801028B by the Jiangsu Postdoctoral Science Research Foundation
文摘Aiming at the application of a wireless sensor network to locating miners in underground mine,we design a wireless sensor network location node system,considering the communication performance and the intrinsic safety. The location node system consists of a mobile node,several fixed nodes,and a sink node,all of whose circuits were designed based on CC2430. A varistor and a RC circuit were used in the reset circuit of a sensor node to guarantee the intrinsic safety by reducing discharge energy,the theoretical analysis of the discharge energy shows that the reset circuit is an intrinsic safety one. The analysis and simulation about the performance of the location node system are discussed,such as network communication delay and packet loss rate,the results show that the highest network communication delay of the system is about 0.11 seconds,and the highest packet loss rate is about 0.13,which assures the location node system has a high reliability,and can locate miners in the underground mine.
基金supported by the National Natural Science Foundation of China(30471302).
文摘The present study has been performed to understand the location of the virus, type of apoptotic cells, and their relation to lymph nodes of piglets infected with porcine circovirus type Ⅱ (PCV-2). Nine 32-day-old conventional piglets free of infection with PCV-2 were used, and distributed into three groups: control group (n = 3), piglets inoculated with PCV-2 alone (PCV-2, n = 3), and PCV-2 inoculated and KLH immunostimulated group (PCV-2 + KLH, n = 3). Superficial inguinal lymph nodes from all piglets were collected for histological examination after 32 days postinoculation, and immunohistochemistry for PCV-2 detection. Location of apoptotic cells was detected with TdT-mediated dUTP nick end labeling (TUNEL) and cell cycle, and the apoptotic rates were measured by flow cytometry. The characteristic histopathological lesions of the piglets in PCV-2 and PCV-2 + KLH were lymphocyte depletions in the cortex and paracortex of the lymph nodes, epithelioid-like macrophage infiltration, and intracytoplasmic inclusion bodies presented in epithelioid-like macrophages. PCV-2 was mainly found in epithelioid-like macrophages by immunohistochemistry. In the lymph nodes, lymphocytes presented higher apoptotic rates in the cortex by TUNEL, special B-cell areas, and similar apoptotic cells were found in this compartment in the control. The apoptotic rates of the lymph nodes were 0.41, 3.34, and 4.88% in the control, PCV-2, and PCV-2 + KLH groups by flow cytometry, respectively. The apoptotic rates of lymph nodes for PCV-2 and PCV-2 + KLH piglets were significantly higher than those for the control group (P〈0.05 and P〈0.01). The proliferation index (PI) was 0.17_+0.01, 0.12_+0.01 and 0.12_+0.04 in the control, PCV-2, and PCV-2 + KLH group, the PI of the control group was higher than that of the other groups, but without the statistical difference. PCV-2 can induce lymphocyte depletion in lymph nodes of piglets by blocking cell proliferation and promoting apoptosis. This is one of the mechanisms of immunosuppression on infected piglets by PCV-2.
基金supported by grants from the Foundation of Bureau of Health of Xiamen City (No. 200205)
文摘Objective: The presence of lymph node metastases is an important factor in the prognosis of gastric cancer patient. Therefore, the precise identification of sentinel lymph nodes (SLN) in these patients is critical. In this work, we investigated the feasibility and preciseness by injection of 99mTc-sulfur colloid (SC) 2 hours before operation after general anesthesia, instead of one day before surgery. Methods: Thirty-one patients of gastric cancer diagnosed as T1-T3 were enrolled in this study. During operation, a SLN was defined as those containing 10 times more radioactivity than surrounding tissue with a hand-held gamma probe and removed. All the patients underwent radical gastrectomy with extended lymphadenectomy. All resected nodes were examined postoperatively by routine H&E stain and those negative SLNs were examined with further cytokeratin immunohistochemistical staining. Results: The incidence of metastasis was significantly higher in SLNs than in non-SLNs (x2=67.48, P〈0.001). The overall sensitivity, specificity and accuracy of the SLN status in the diagnosis of the lymph node status of the patient were 86.36%, 100% and 96.77%, respectively. The positive predictive value and negative predictive value of SLN biopsy were 100%, and 75.0%, respectively. SLNs were used to diagnose the lymph node status with 100% accuracy in the T1 group. In the T2 and T3 groups, the sensitivity, specificity, and diagnostic accuracy were 92.3%, 100%, and 94.44%, 60.0%, 100%, and 66.66%, respectively. Most of the SLNs were located in the #1, #2, #3, #4, #5, and #6, except in 3 patients (9.68%).With cytokeratin immunohistochemical staining, lymphatic pathologic staging in 1 patient was upstaged. Conclusion: SLN biopsy with the above approach is a feasible and accurate diagnostic procedure for detecting lymph node metastasis in patients with gastric cancer, which is painless, noninvasive, easily accepted by patients and suitable for extensive clinical applications.
文摘Objective: The aim of this study was to investigate Cathepsin-D (Cath-D) expression in different location and its relationship with prognosis in the axillary lymph nodes negative (ANN) breast cancer patients. Methods: Cath-D expression in 192 cases of breast carcinoma were examined by immunohistochemistry. Depending on different parts of expression, three evaluating methods were used, compared and analysed. Results: The positive rate of Cath-D expression in ANN breast cancer with poor prognosis group and axillary nodes positive (ANP) group were significantly higher than that in ANN breast cancer with good prognosis group (x 2=23.20,P<0.01), while there was no significant difference between ANP group and ANN with poor prognosis group (x 2=0.19,P>0.05). Cath-D expression in stromal cells had no statistical difference among the three groups (x}2=1.56,P>0.05). When the Cath-D expression in cancer and stromal cells were counted into the positive rate, it was near the same (u 1=0.47,u 2=1.41,P>0.05). Conclusion: These results suggest that Cath-D expression is one of the powerful prognostic markers in ANN breast cancer. It’s a reliable, practical, and convenient method to observe and evaluate Cath-D expression in cancer cells.
文摘The thesis work was carried out in two phases. Firstly, we have designed the Cluster-Based Object Location Algorithm (CBOLA) for finding the object location in a cluster based network topology. Secondly, to take the advantages of clustering architecture of Mobile Ad hoc Networks, we have especially designed Object Location Clusters Algorithm (OLCA) for efficient Object Location management in MANET. Our comparison of simulation analysis shows that the CBOLA is more efficient and accurate in location information services and more robust than GLS and HRLS. In addition, we believe that our comparative study with the various location services schemes was facilitated accurate results in ad hoc networks. we are portioned our network area by designing a new clustering algorithm called OLCA (Object Location Clusters Algorithm) for efficient object location in Mobile Ad hoc Networks. Simulation results and comparative analysis shows the performance and effectiveness of CBOLA and OLCA.
基金National Natural Science Foundations of China(Nos.U1162202,61203157)the Fundamental Research Funds for the Central Universities and Shanghai Leading Academic Discipline Project,China(No.B504)
文摘For mobile anchor node static path planning cannot accord the actual distribution of node for dynamic adjustment. We take advantage of the high localization accuracy and low computational complexity of ad-hoc localization system( AHLos)algorithm. This article introduces mobile anchor nodes instead of the traditional fixed anchor nodes to improve the algorithm. The result shows that, through introduce the mobile anchor node, the information of initial anchor nodes can be configured more flexible.Meanwhile,with the use of the approximate location and the transition path,the distance and energy consumption of the mobile anchor node is greatly reduced.
基金Project supported by the Shanghai Leading Academic Discipcine Project (Grant No.S30108)the National Natural Science Foundation of China (Grant No.60872021)the Science and Technology Commission of Shanghai Municipality (Grant No.08DZ2231100)
文摘Localization of the sensor nodes is a key supporting technology in wireless sensor networks (WSNs). In this paper, a real-time localization estimator of mobile node in WSNs based on extended Kalman filter (KF) is proposed. Mobile node movement model is analyzed and online sequential iterative method is used to compute location result. The detailed steps of mobile sensor node self-localization adopting extended Kalman filter (EKF) is designed. The simulation results show that the accuracy of the localization estimator scheme designed is better than those of maximum likelihood estimation (MLE) and traditional KF algorithm.
基金supported by the National Natural Science Foundation of China(62231020)the Youth Innovation Team of Shaanxi Universities。
文摘The foundation of ad hoc networks lies in the guarantee of continuous connectivity.However,critical nodes,whose failure can easily destroy network connectivity,will influence the ad hoc network connectivity significantly.To protect the network efficiently,critical nodes should be identified accurately and rapidly.Unlike existing critical node identification methods for unknown topology that identify critical nodes according to historical information,this paper develops a critical node identification method to relax the prior topology information condition about critical nodes.Specifically,we first deduce a theorem about the minimum communication range for a node through the number of nodes and deployment ranges,and prove the universality of the theorem in a realistic two-dimensional scenario.After that,we analyze the relationship between communication range and degree value for each node and prove that the greater number of nodes within the communication range of a node,the greater degree value of nodes with high probability.Moreover,we develop a novel strategy to improve the accuracy of critical node identification without topology information.Finally,simulation results indicate the proposed strategy can achieve high accuracy and low redundancy while ensuring low time consumption in the scenarios with unknown topology information in ad hoc networks.
文摘This paper, taking the distance between the piezoelectric ceramic center and the displacement node location of the transducer as a parameter, investigates the relation of characteristic parameters of transducer, such as force factor, equivalent resistance, potential maximum electroacoustical efficiency, and loading performance, to the displacement node location. Some design considerations about the selection of node location are noted .