The Northridge earthquake inflicted various levels of damage upon a large number of Caltrans' bridges not retrofitted by column jacketing.In this respect,this study represents results of fragility curve developmen...The Northridge earthquake inflicted various levels of damage upon a large number of Caltrans' bridges not retrofitted by column jacketing.In this respect,this study represents results of fragility curve development for two (2) sample bridges typical in southern California,strengthened for seismic retrofit by means of steel jacketing of bridge columns.Monte Carlo simulation is performed to study nonlinear dynamic responses of the bridges before and after column retrofit.Fragility curves in this study are represented by lognormal distribution functions with two parameters and developed as a function of PGA.The sixty (60) ground acceleration time histories for the Los Angeles area developed for the Federal Emergency Management Agency (FEMA) SAC (SEAOC-ATC CUREe) steel project are used for the dynamic analysis of the bridges. The improvement in the fragility with steel jacketing is quantified by comparing fragility curves of the bridge before and after column retrofit.In this first attempt to formulate the problem of fragility enhancement,the quantification is made by comparing the median values of the fragility curves before and after the retrofit.Under the hypothesis that this quantification also applies to empirical fragility curves developed on the basis of Northridge earthquake damage,the enhanced version of the empirical curves is developed for the ensuing analysis to determine the enhancement of transportation network performance due to the retrofit.展开更多
Over the past decade, seismically induced damage to bridges has been widely reported following major earthquakes such as the 1994 Northridge, 1995 Kobe and 1999 Chi-Chi events. Since these earthquakes, restrainers and...Over the past decade, seismically induced damage to bridges has been widely reported following major earthquakes such as the 1994 Northridge, 1995 Kobe and 1999 Chi-Chi events. Since these earthquakes, restrainers and stoppers have been installed on bridges to prevent unseating and excessive displacements, respectively. Alternatively, column jacketing has also been proven to be effective. However, the enhanced shear strength may result in extra retrofitting works on the footing. For bridges damaged in the Chi-Chi earthquake, investigations revealed that most bridge columns experienced none-to-minor damage in the longitudinal direction. The reason for this unexpected performance was the construction practice of using a rubber bearing, which is an unbolted design that may slide under large lateral forces. In this paper, parametric studies on simply-supported bridges retrofitted by a restrainer or concrete shear key along the longitudinal and transverse axes were carried out. The research focuses on finding suitable combinations of the design force and gap spacing so the restrainer and concrete shear key can be used as an unseating prevention device, with respect to the allowable column damage in terms of displacement ductility under near-fault type earthquakes. A two-lane PCI-girder bridge was selected as the benchmark model. In the longitudinal direction, a total of nine combinations considering yielding strength and gap spacing for the restrainer were analyzed; while parameters for the concrete shear key were divided into three shear force levels and three gap spacings. In the transverse direction, a similar approach was adapted, except smaller gap spacing was used. For each of the above mentioned earthquakes, seven input ground motions were selected and their PGAs were adjusted to 0.36g and 0.45g as the Design earthquake and Maximum Considerable Earthquake, respectively. Based on the results of nonlinear time history analyses, proper parameters to design the restrainers and concrete shear keys are obtained. Responses obtained from numerical simulations under the Chi-Chi earthquake leaded to new implications to design those devices. Restrainer should not exceed its breaking strain and sufficient unseating length will be needed always. Concrete Shear key was determined by considering both displacement demand of the superstructure and displacement ductility of the column at the same time. Further study is needed to provide optimal design parameters for use in performance based bridge design.展开更多
Illyria hotel (formerly Bozhur) was built during the sixties in the heart of the actual Kosovo's capital Prishtina, according to former old Yugoslav standards in a Modernist architectural style. It represents a mas...Illyria hotel (formerly Bozhur) was built during the sixties in the heart of the actual Kosovo's capital Prishtina, according to former old Yugoslav standards in a Modernist architectural style. It represents a massive structural system with brick walls up to 54 cm thick and "avramenko" type reinforced concrete floors. The investor's aim was to add another two floors on the top of the existing ones and to build two level underground parking floors, a health spa centre, whilst at the vicinity of the existing building (the northern side) to erect a new 17 story-high brand new hotel and administration building. The retrofitting of the structure as well as construction of the new structure has been done in full accordance with the new structural Eurocodes' recommendations. 3D FEM (finite element method) modeling was used for the analysis and design, using ETABS v 9.5 nonlinear and ARSAP 2010 (Autodesk Robot Structural Analysis Professional 2010). Response spectrum design according to EC 8,3.2.2.4 has been used for seismic analysis and design with a reference peak ground acceleration on type A ground Of AgR = 0.25 g.展开更多
基金MCEER/FHWA under Contract No.DTFH 61-98-C-00094Caltrans under Contract No.59A0304
文摘The Northridge earthquake inflicted various levels of damage upon a large number of Caltrans' bridges not retrofitted by column jacketing.In this respect,this study represents results of fragility curve development for two (2) sample bridges typical in southern California,strengthened for seismic retrofit by means of steel jacketing of bridge columns.Monte Carlo simulation is performed to study nonlinear dynamic responses of the bridges before and after column retrofit.Fragility curves in this study are represented by lognormal distribution functions with two parameters and developed as a function of PGA.The sixty (60) ground acceleration time histories for the Los Angeles area developed for the Federal Emergency Management Agency (FEMA) SAC (SEAOC-ATC CUREe) steel project are used for the dynamic analysis of the bridges. The improvement in the fragility with steel jacketing is quantified by comparing fragility curves of the bridge before and after column retrofit.In this first attempt to formulate the problem of fragility enhancement,the quantification is made by comparing the median values of the fragility curves before and after the retrofit.Under the hypothesis that this quantification also applies to empirical fragility curves developed on the basis of Northridge earthquake damage,the enhanced version of the empirical curves is developed for the ensuing analysis to determine the enhancement of transportation network performance due to the retrofit.
文摘Over the past decade, seismically induced damage to bridges has been widely reported following major earthquakes such as the 1994 Northridge, 1995 Kobe and 1999 Chi-Chi events. Since these earthquakes, restrainers and stoppers have been installed on bridges to prevent unseating and excessive displacements, respectively. Alternatively, column jacketing has also been proven to be effective. However, the enhanced shear strength may result in extra retrofitting works on the footing. For bridges damaged in the Chi-Chi earthquake, investigations revealed that most bridge columns experienced none-to-minor damage in the longitudinal direction. The reason for this unexpected performance was the construction practice of using a rubber bearing, which is an unbolted design that may slide under large lateral forces. In this paper, parametric studies on simply-supported bridges retrofitted by a restrainer or concrete shear key along the longitudinal and transverse axes were carried out. The research focuses on finding suitable combinations of the design force and gap spacing so the restrainer and concrete shear key can be used as an unseating prevention device, with respect to the allowable column damage in terms of displacement ductility under near-fault type earthquakes. A two-lane PCI-girder bridge was selected as the benchmark model. In the longitudinal direction, a total of nine combinations considering yielding strength and gap spacing for the restrainer were analyzed; while parameters for the concrete shear key were divided into three shear force levels and three gap spacings. In the transverse direction, a similar approach was adapted, except smaller gap spacing was used. For each of the above mentioned earthquakes, seven input ground motions were selected and their PGAs were adjusted to 0.36g and 0.45g as the Design earthquake and Maximum Considerable Earthquake, respectively. Based on the results of nonlinear time history analyses, proper parameters to design the restrainers and concrete shear keys are obtained. Responses obtained from numerical simulations under the Chi-Chi earthquake leaded to new implications to design those devices. Restrainer should not exceed its breaking strain and sufficient unseating length will be needed always. Concrete Shear key was determined by considering both displacement demand of the superstructure and displacement ductility of the column at the same time. Further study is needed to provide optimal design parameters for use in performance based bridge design.
文摘Illyria hotel (formerly Bozhur) was built during the sixties in the heart of the actual Kosovo's capital Prishtina, according to former old Yugoslav standards in a Modernist architectural style. It represents a massive structural system with brick walls up to 54 cm thick and "avramenko" type reinforced concrete floors. The investor's aim was to add another two floors on the top of the existing ones and to build two level underground parking floors, a health spa centre, whilst at the vicinity of the existing building (the northern side) to erect a new 17 story-high brand new hotel and administration building. The retrofitting of the structure as well as construction of the new structure has been done in full accordance with the new structural Eurocodes' recommendations. 3D FEM (finite element method) modeling was used for the analysis and design, using ETABS v 9.5 nonlinear and ARSAP 2010 (Autodesk Robot Structural Analysis Professional 2010). Response spectrum design according to EC 8,3.2.2.4 has been used for seismic analysis and design with a reference peak ground acceleration on type A ground Of AgR = 0.25 g.