This study proposes a multi-scale finite element simulation method to investigate the vehicle-induced local vibration effects of orthotropic steel decks(OSDs)by considering tire-road contact conditions.It also focuses...This study proposes a multi-scale finite element simulation method to investigate the vehicle-induced local vibration effects of orthotropic steel decks(OSDs)by considering tire-road contact conditions.It also focuses on the differences between the dynamic amplification factors(DAFs)of local deflection and strain compared to those corresponding overall response,as well as the influence of road roughness and driving speed on localized DAFs.The results show that vehicle-induced local vibration is distinct near vehicle wheels,especially within 0.5 m from the wheel centerline in the transverse direction and 0.3 m in the longitudinal direction.The localized strain DAFs may potentially exceed 1.4.Generally,the dynamic deflection of a bridge deck is mainly determined by the first system stiffness of OSDs,i.e.,sectional stiffness of the bridge girder.However,the dynamic strain of OSDs arises from the combination of overall bridge modes and local bridge deck panel modes,leading to a higher localized strain DAFs of approximately 16%compared to the overall bridge.Longitudinal and vertical strain DAFs typically occur on U-ribs,while the transverse strain DAFs often arise at stiffness discontinuities of OSD.The recurrent structural variations of OSDs in the transverse and vertical directions result in the maximum vertical strain DAF.展开更多
This paper is focused on the structural behavior of the single shear bolted connections with thin-walled ferritic stainless steel.The purpose of this study is to investigate the ultimate behaviors,such as ultimate str...This paper is focused on the structural behavior of the single shear bolted connections with thin-walled ferritic stainless steel.The purpose of this study is to investigate the ultimate behaviors,such as ultimate strength and fracture mode of the single shear bolted connections of thin-walled ferritic stainless steel(low cost steel) rather than austenitic stainless steel(high cost steel).Bolt arrangement and end distance parallel to the direction of applied load are considered as main variables of the test specimens for bolted connections.Specimens have a constant dimension of edge distance perpendicular to the loading direction,bolt diameter,pitch,and gauge.A monotonic tensile test for specimens has been carried out and some bolted connections with long end distance showed curling(out of plane deformation) occurrence which led to strength reduction.The ultimate behaviors such as fracture mode,ultimate strength are compared with those predicted by current design codes.Further,conditions of curling occurrence and the strength reduction due to curling are investigated and modified strength equations are suggested considering the curling effect.展开更多
With the rapid development of microscale cellular structures, the small-diameter cold-formed welded stainless steel tubes have recently been used for creating the metallic lat- tice topologies with high mechanical pro...With the rapid development of microscale cellular structures, the small-diameter cold-formed welded stainless steel tubes have recently been used for creating the metallic lat- tice topologies with high mechanical properties. In this paper, to obtain the accurate material properties of the circular hollow section (CHS) under pure compression, a series of concentric compression tests are conducted on the millimeter-scale cold-formed 304 stainless steel circu- lar tubular stub columns after exposure to a vacuum brazing process. The tests cover a total of 18 small-diameter stub tubes with measured thickness-to-diameter ratios (t/D) from 0.023 to 0.201. A generalized three-stage nominal stress-strain model is developed for describing the compressive behavior of the post-brazing CHSs over the full strain range. This mechanical model is especially applicable to computer code implementation. Hence, an interactive computer pro- gram is developed to simultaneously optimize three strain hardening exponents (n1, n2, n3) in the expression of the model to produce the stress-strain curve capable of accurately replicating the test data. To further reduce the number of the model and material parameters on which this model depends, this paper also develops five expressions for determining the 2.5% proof stress (ap2), n2, the ultimate compressive strength (σp3), n3, and the ultimate plastic strain (p3%) for given experimental values of three basic material parameters (E0, σ0.01, σ0.2). These expressions are validated to he effective for the CHSs with t/D 〉_ 0.027. The analytically predicted full-range stress-strain curves have generally shown close agreement with the ones obtained experimentally.展开更多
Application of weathering and cold-formed steel in transmission lines can reduce steel consumption and environmental pollution. Some advances in the studies on the weathering and cold-formed steel in transmission towe...Application of weathering and cold-formed steel in transmission lines can reduce steel consumption and environmental pollution. Some advances in the studies on the weathering and cold-formed steel in transmission tower are introduced. Firstly, corrosion-resistant tests of weathering steel samples under different simulating technical atmospheres were carried out separately for 240 hours. It shows that the corrosion degree of joint samples is higher than that of single chip samples, and the corrosion-resistant performance of weathering steel is superior to common carbon steel. The corrosion-resistance of weathering steel meets with the requirement of transmission tower. Secondly, experiments and finite element analysis for cold-formed angles and a 220kV prototype tower were completed, and the stability coeffi-cient fitting curves as well as the modification formulas of slenderness ratio for cold-formed members were determined. According to the structural characteristics of transmission towers, four sections of cold-formed angles with different sections and slenderness ratios were selected in this study. The finite element model well predicted the buckling behav-iour of the cold-formed members. Ultimate loads calculating by the fitting curve were well agreed to the experimental values, especially for the members with small slenderness ratios. Weight of the cold-formed steel tower can be reduced by more than 5 percent after considering the strength enhancement. Cost of the weathering and cold-formed steel transmission tower is nearly equivalent to that of hot-rolled steel tower with hot galvanizing.展开更多
In this study, the suitability of current design methods for the 0.2% proof yield strength of the comer regions for high strength cold-formed steel at normal room temperature was investigated. The current standard pre...In this study, the suitability of current design methods for the 0.2% proof yield strength of the comer regions for high strength cold-formed steel at normal room temperature was investigated. The current standard predictions are generally accurate for outer comer specimen but conservative for inner comer specimen. Based on the experimental results, an analytical model to predict the comer strength of high strength cold-formed steel at normal room temperature was also proposed. The comparison indicated that the proposed model predicted well the comer strength of high strength cold-formed steel not only at normal room temperature but also at elevated temperatures. It is shown that the predictions obtained from the proposed model agree well with the test results. Generally the comer strength enhancement of high strength cold-formed steel decreases when the temperature increases.展开更多
Given their numerous functional and architectural benefits,such as improved bearing capacity and increased resistance to elastic instability modes,cold-formed steel(CFS)built-up sections have become increasingly devel...Given their numerous functional and architectural benefits,such as improved bearing capacity and increased resistance to elastic instability modes,cold-formed steel(CFS)built-up sections have become increasingly developed and used in recent years,particularly in the construction industry.This paper presents an analytical and numerical study of assembled CFS two single channel-shaped columns with different slenderness and configurations(backto-back,face-to-face,and box).These columns were joined by double-row rivets for the back-to-back and box configurations,whereas they were welded together for the face-to-face design.The built-up columns were filled with ordinary concrete of good strength.Finite element models were applied,using ABAQUS software,to assess mechanical performance and study the influence of assembly techniques on the behavior of cold-formed columns under axial compression.Analytical approaches based on Eurocode 3 and Eurocode 4 recommendations for un-filled and concrete-filled columns respectively were followed for the numerical analysis,and concrete confinement effects were also considered per American Concrete Institute(ACI)standards for face-to-face and box configurations.The obtained results indicated a good correlation between the numerical results and the proposed analytical methodology which did not exceed 8%.The failure modes showed that the columns failed due to instabilities such as local and global buckling.展开更多
The hollow flange beam(HFB) is a unique cold-formed steel section developed in Australia for use as a flexural member.It′s a particular cross section with two torsion rigid closed triangular flanges and a comparative...The hollow flange beam(HFB) is a unique cold-formed steel section developed in Australia for use as a flexural member.It′s a particular cross section with two torsion rigid closed triangular flanges and a comparatively flexible web,and it is a type of high efficient cross section.This paper presents two kinds of new cold-formed flange-closed welding sections named HF1 and HF2 according to different section component and parameters of HFB.Nonlinear finite element method has been adopted to investigate the mechanical properties such as buckling mode,deformation process,rigidity,ductility and correlation curve of two kinds of new section members which being subjected to axial compression,flexure,combined compression and bending.Systematical comparisons of the consumed steel quantities of per unit load carrying capacity between new section members and the same section dimensions of cold-formed C-section members have been carried out.Some conclusions can be drawn from above work that the new sections have some superior properties including higher load carrying capacity and section modulus,sufficient section stiffness,and difficult occurrence for the sub element local buckling.The new sections are suitable for bearing flexure,compression,combined compression and bending.The new sections′ consumed steel quantities of per unit load carrying capacity are almost half as those of the same dimension C-section members′.The experimental investigation is carried out further on the new cold-formed flange-closed welding section members and can be used in the practical engineering.展开更多
Pitting corrosion is harmful during bridge construction,which will lead to uneven roughness of steel surfaces and reduce the thickness of steel.Hence,the effect of pitting corrosion on the mechanical properties of col...Pitting corrosion is harmful during bridge construction,which will lead to uneven roughness of steel surfaces and reduce the thickness of steel.Hence,the effect of pitting corrosion on the mechanical properties of cold-formed thin-walled steel stub columns is studied,and the empirical formulas are established through regression fitting to predict the ultimate load of web and flange under pitting corrosion.In detail,the failure modes and load-displacement curves of specimens with different locations,area ratios,and depths are obtained through a large number of non-linear finite element analysis.As for the specimens with pitting corrosion on the web,all the specimens are subject to local buckling failure,and the failure mode will not change with pitting corrosion,but the failure location will change with pitting corrosion location;the size,location,and area ratio of pitting corrosion have little influence on the ultimate load of cold-formed thin-walled steel short columns,but the loss rate of pitting corrosion section area has a greater impact on the ultimate bearing capacity.As for the specimen with flange pitting corrosion,the location and area ratio of pitting corrosion have less influence on the ultimate load of cold-formed thin-walled steel short columns,and the section area loss rate has greater influence on the ultimate bearing capacity;the impact of web pitting corrosion on the ultimate load is greater than that of flange pitting corrosion under the same condition of pitting corrosion section area.The prediction formulas of limit load which are suitable for pitting corrosion of web and flange are established,which can provide a reference for performance evaluation of corroded cold-formed thin-walled steel.展开更多
Accurate recognition of flight deck operations for carrier-based aircraft, based on operation trajectories, is critical for optimizing carrier-based aircraft performance. This recognition involves understanding short-...Accurate recognition of flight deck operations for carrier-based aircraft, based on operation trajectories, is critical for optimizing carrier-based aircraft performance. This recognition involves understanding short-term and long-term spatial collaborative relationships among support agents and positions from long spatial–temporal trajectories. While the existing methods excel at recognizing collaborative behaviors from short trajectories, they often struggle with long spatial–temporal trajectories. To address this challenge, this paper introduces a dynamic graph method to enhance flight deck operation recognition. First, spatial–temporal collaborative relationships are modeled as a dynamic graph. Second, a discretized and compressed method is proposed to assign values to the states of this dynamic graph. To extract features that represent diverse collaborative relationships among agents and account for the duration of these relationships, a biased random walk is then conducted. Subsequently, the Swin Transformer is employed to comprehend spatial–temporal collaborative relationships, and a fully connected layer is applied to deck operation recognition. Finally, to address the scarcity of real datasets, a simulation pipeline is introduced to generate deck operations in virtual flight deck scenarios. Experimental results on the simulation dataset demonstrate the superior performance of the proposed method.展开更多
The impact of longitudinal stiffener configurations on the structural performance of orthotropic steel bridge decks(OSD)was systematically investigated,with emphasis on U-shaped,T-shaped,and rectangular ribs.Finite el...The impact of longitudinal stiffener configurations on the structural performance of orthotropic steel bridge decks(OSD)was systematically investigated,with emphasis on U-shaped,T-shaped,and rectangular ribs.Finite element analysis was employed to evaluate deformation and stress distribution under three critical loading scenarios:vertical uniformload,vertical eccentric load,and lateral uniformload.Equivalentmodels ensuring identical steel usage,moment of inertia,and centroid alignment were established to compare five stiffener configurations.Results demonstrate that U-rib configurations exhibit superior performance in controlling local displacements and minimizing stress concentrations.Under eccentric loading,U-ribs significantly reduce deck displacement andmitigate stress fluctuations at critical junctions compared to alternative stiffeners.Stability analysis further reveals that U-ribs achieve stability coefficients substantially higher than open-section alternatives,particularly excelling under lateral loading due to enhanced torsional rigidity.Parametric optimization identifies key geometric thresholds where U-rib thickness exceeding 6 mm yields diminishing returns in stress reduction and stability enhancement,while deck flange thickness beyond 16 mm provides marginal improvements in displacement control despite increased material usage.An optimized design combining 6-mm U-ribs with 16-mm deck flanges is proposed,balancing structural efficiency with stringent deformation requirements for high-speed rail bridges.These findings provide foundational insights for optimizing stiffener selection and enhancing the longevity of orthotropic steel bridge decks in heavy-load applications.展开更多
Installing the splitter plates is a passive aerodynamic solution for eliminating vortex-induced vibration (VIV). However, the influences of splitter plates on the VIV and aerostatic performances are more complicated d...Installing the splitter plates is a passive aerodynamic solution for eliminating vortex-induced vibration (VIV). However, the influences of splitter plates on the VIV and aerostatic performances are more complicated due to aerodynamic interference between highway and railway decks. To study the effects of splitter plates, wind tunnel experiments for measuring VIV and aerostatic forces of twin decks under two opposite flow directions were conducted, while the surrounding flow and wind pressure of static twin decks with and without splitter plates are numerically simulated. The results showed that the incoming flow direction affects the VIV response and aerostatic coefficients. The highway deck has poor vertical and torsional VIV, and the VIV region and amplitude are different under different directions. While the railway deck only has vertical VIV when located upstream. The splitter plates can impede the process of vortex generation, shedding and impinging at the gap between twin deck, and significantly reducing the surface fluctuating pressure coefficient, thus effectively suppressing the VIV of twin decks. While, the splitter plates hurt the upstream deck regarding static wind stability and have little effect on the downstream deck. The splitter plates of appropriate width are recommended to improve VIV performances in twin parallel bridges.展开更多
Based on four-year field inspection and investigation on deck pavement of mastic asphalt on Jiangyin Bridge, cracking causes of mastic asphalt are studied. Cracks of deck pavement are summarized on crack length and wi...Based on four-year field inspection and investigation on deck pavement of mastic asphalt on Jiangyin Bridge, cracking causes of mastic asphalt are studied. Cracks of deck pavement are summarized on crack length and width to get a clear view of their propagations. Traffic surveys including traffic volume, axle load and vehicle speed were also conducted to assess their influences. Samples taken on-site were tested with pulling-out test and fatigue test to benchmark their properties. According to the inspection and tests results, it is concluded that the cracks are induced by rutting and fatigue. Lack of fatigue resistance, not well bonded to the steel deck and insufficient high temperature stability are supposed to be the main reasons as well as high density of low speed, excessively overloaded trucks.展开更多
A model for predicting the interface behavior of epoxy asphalt and steel composite beam under negative bending is developed incorporating partial interaction theory. Interfacial slips between the steel deck and the ep...A model for predicting the interface behavior of epoxy asphalt and steel composite beam under negative bending is developed incorporating partial interaction theory. Interfacial slips between the steel deck and the epoxy asphalt surfacing are included in the model with a new parameter of membrane stiffness. A series of analytical equations based on this model are derived to calculate slip and strain at the interface. Also, a numerical procedure for calculating the load responses of simply supported composite beams with concentrated force at the mid-span is established and verified with two samples. Characters of slip and strain at the interface, sensitivities of tensile stress and interface shear stress with material parameters are studied. It can be concluded that interfacial effects decrease the bending stiffness of the composite; hard and stiff bonding material is better for asphalt surfacing layer working at normal to low temperatures, and the damage of the asphalt surfacing layer will be accelerated with the damage accumulation of the bonding coat.展开更多
To analyze the stress state of steel orthotropic deck pavement and provide reference for the design of the overlay, the inner stress state and strain distribution of surfacing under the load of the deformation of the ...To analyze the stress state of steel orthotropic deck pavement and provide reference for the design of the overlay, the inner stress state and strain distribution of surfacing under the load of the deformation of the whole bridge structure and tyre load are analyzed by the finite element method of submodeling. Influence of surfacing modulus on the strain state of the overlay is analyzed for the purpose of the optimal design of the overlay structure. Analysis results show that the deformation of the whole bridge structure has no evident influence on the stress state of the overlay. The key factor of the overlay design is the transverse tensile strain in the overlay above the upper edge of web plate of rib. The stress state of the overlay is influenced evidently by the modulus of rigidity transform overlay. And the stress state of the overlay can be optimized and lowered by increasing the modulus and thickness of rigidity transform overlay, The fatigue test has been done to evaluate the fatigue performance and modulus of different deck pavement materials such as epoxy asphalt, SBS modified asphalt, rosphalt asphalt which can provide reference for deck pavement structure design.展开更多
基金National Key R&D Project of China under Grant No.2021YFB2600601the Science and Technology Research Program of Chongqing Municipal Education Commission under Grant No.KJZD-K202100704+1 种基金Team Building Project for Graduate Tutors in Chongqing under Grant No.JDDSTD2022003the Joint Training Base Construction Project for Graduate Students in Chongqing under Grant No.JDLHPYJD2020023。
文摘This study proposes a multi-scale finite element simulation method to investigate the vehicle-induced local vibration effects of orthotropic steel decks(OSDs)by considering tire-road contact conditions.It also focuses on the differences between the dynamic amplification factors(DAFs)of local deflection and strain compared to those corresponding overall response,as well as the influence of road roughness and driving speed on localized DAFs.The results show that vehicle-induced local vibration is distinct near vehicle wheels,especially within 0.5 m from the wheel centerline in the transverse direction and 0.3 m in the longitudinal direction.The localized strain DAFs may potentially exceed 1.4.Generally,the dynamic deflection of a bridge deck is mainly determined by the first system stiffness of OSDs,i.e.,sectional stiffness of the bridge girder.However,the dynamic strain of OSDs arises from the combination of overall bridge modes and local bridge deck panel modes,leading to a higher localized strain DAFs of approximately 16%compared to the overall bridge.Longitudinal and vertical strain DAFs typically occur on U-ribs,while the transverse strain DAFs often arise at stiffness discontinuities of OSD.The recurrent structural variations of OSDs in the transverse and vertical directions result in the maximum vertical strain DAF.
基金Project supported by the Basic Science Research Program through the National Research Foundation of Korea(NRF) funded by the Ministry of Education,Science and Technology(MEST)(No.2012-00-2110)the Sustainable Building Research Center of Hanyang University funded by the SRC/ERC Program of MEST(No.2012-0000-723)
文摘This paper is focused on the structural behavior of the single shear bolted connections with thin-walled ferritic stainless steel.The purpose of this study is to investigate the ultimate behaviors,such as ultimate strength and fracture mode of the single shear bolted connections of thin-walled ferritic stainless steel(low cost steel) rather than austenitic stainless steel(high cost steel).Bolt arrangement and end distance parallel to the direction of applied load are considered as main variables of the test specimens for bolted connections.Specimens have a constant dimension of edge distance perpendicular to the loading direction,bolt diameter,pitch,and gauge.A monotonic tensile test for specimens has been carried out and some bolted connections with long end distance showed curling(out of plane deformation) occurrence which led to strength reduction.The ultimate behaviors such as fracture mode,ultimate strength are compared with those predicted by current design codes.Further,conditions of curling occurrence and the strength reduction due to curling are investigated and modified strength equations are suggested considering the curling effect.
基金The work was supported by the National Natural Science Foundation of China under Grant Nos. 11432004 and 11421091.
文摘With the rapid development of microscale cellular structures, the small-diameter cold-formed welded stainless steel tubes have recently been used for creating the metallic lat- tice topologies with high mechanical properties. In this paper, to obtain the accurate material properties of the circular hollow section (CHS) under pure compression, a series of concentric compression tests are conducted on the millimeter-scale cold-formed 304 stainless steel circu- lar tubular stub columns after exposure to a vacuum brazing process. The tests cover a total of 18 small-diameter stub tubes with measured thickness-to-diameter ratios (t/D) from 0.023 to 0.201. A generalized three-stage nominal stress-strain model is developed for describing the compressive behavior of the post-brazing CHSs over the full strain range. This mechanical model is especially applicable to computer code implementation. Hence, an interactive computer pro- gram is developed to simultaneously optimize three strain hardening exponents (n1, n2, n3) in the expression of the model to produce the stress-strain curve capable of accurately replicating the test data. To further reduce the number of the model and material parameters on which this model depends, this paper also develops five expressions for determining the 2.5% proof stress (ap2), n2, the ultimate compressive strength (σp3), n3, and the ultimate plastic strain (p3%) for given experimental values of three basic material parameters (E0, σ0.01, σ0.2). These expressions are validated to he effective for the CHSs with t/D 〉_ 0.027. The analytically predicted full-range stress-strain curves have generally shown close agreement with the ones obtained experimentally.
文摘Application of weathering and cold-formed steel in transmission lines can reduce steel consumption and environmental pollution. Some advances in the studies on the weathering and cold-formed steel in transmission tower are introduced. Firstly, corrosion-resistant tests of weathering steel samples under different simulating technical atmospheres were carried out separately for 240 hours. It shows that the corrosion degree of joint samples is higher than that of single chip samples, and the corrosion-resistant performance of weathering steel is superior to common carbon steel. The corrosion-resistance of weathering steel meets with the requirement of transmission tower. Secondly, experiments and finite element analysis for cold-formed angles and a 220kV prototype tower were completed, and the stability coeffi-cient fitting curves as well as the modification formulas of slenderness ratio for cold-formed members were determined. According to the structural characteristics of transmission towers, four sections of cold-formed angles with different sections and slenderness ratios were selected in this study. The finite element model well predicted the buckling behav-iour of the cold-formed members. Ultimate loads calculating by the fitting curve were well agreed to the experimental values, especially for the members with small slenderness ratios. Weight of the cold-formed steel tower can be reduced by more than 5 percent after considering the strength enhancement. Cost of the weathering and cold-formed steel transmission tower is nearly equivalent to that of hot-rolled steel tower with hot galvanizing.
基金Project (No. 113000-X80703) supported by the Postdoctoral Fund of Zhejiang Province, China
文摘In this study, the suitability of current design methods for the 0.2% proof yield strength of the comer regions for high strength cold-formed steel at normal room temperature was investigated. The current standard predictions are generally accurate for outer comer specimen but conservative for inner comer specimen. Based on the experimental results, an analytical model to predict the comer strength of high strength cold-formed steel at normal room temperature was also proposed. The comparison indicated that the proposed model predicted well the comer strength of high strength cold-formed steel not only at normal room temperature but also at elevated temperatures. It is shown that the predictions obtained from the proposed model agree well with the test results. Generally the comer strength enhancement of high strength cold-formed steel decreases when the temperature increases.
文摘Given their numerous functional and architectural benefits,such as improved bearing capacity and increased resistance to elastic instability modes,cold-formed steel(CFS)built-up sections have become increasingly developed and used in recent years,particularly in the construction industry.This paper presents an analytical and numerical study of assembled CFS two single channel-shaped columns with different slenderness and configurations(backto-back,face-to-face,and box).These columns were joined by double-row rivets for the back-to-back and box configurations,whereas they were welded together for the face-to-face design.The built-up columns were filled with ordinary concrete of good strength.Finite element models were applied,using ABAQUS software,to assess mechanical performance and study the influence of assembly techniques on the behavior of cold-formed columns under axial compression.Analytical approaches based on Eurocode 3 and Eurocode 4 recommendations for un-filled and concrete-filled columns respectively were followed for the numerical analysis,and concrete confinement effects were also considered per American Concrete Institute(ACI)standards for face-to-face and box configurations.The obtained results indicated a good correlation between the numerical results and the proposed analytical methodology which did not exceed 8%.The failure modes showed that the columns failed due to instabilities such as local and global buckling.
文摘The hollow flange beam(HFB) is a unique cold-formed steel section developed in Australia for use as a flexural member.It′s a particular cross section with two torsion rigid closed triangular flanges and a comparatively flexible web,and it is a type of high efficient cross section.This paper presents two kinds of new cold-formed flange-closed welding sections named HF1 and HF2 according to different section component and parameters of HFB.Nonlinear finite element method has been adopted to investigate the mechanical properties such as buckling mode,deformation process,rigidity,ductility and correlation curve of two kinds of new section members which being subjected to axial compression,flexure,combined compression and bending.Systematical comparisons of the consumed steel quantities of per unit load carrying capacity between new section members and the same section dimensions of cold-formed C-section members have been carried out.Some conclusions can be drawn from above work that the new sections have some superior properties including higher load carrying capacity and section modulus,sufficient section stiffness,and difficult occurrence for the sub element local buckling.The new sections are suitable for bearing flexure,compression,combined compression and bending.The new sections′ consumed steel quantities of per unit load carrying capacity are almost half as those of the same dimension C-section members′.The experimental investigation is carried out further on the new cold-formed flange-closed welding section members and can be used in the practical engineering.
基金funded by the‘Research Project of the Sucheng to Sihong Section of the Yanluo Expressway-Measurement Technology and Application of Bridge Quality Project Based on UAV Binocular Imaging(No.00-00-JSFW-20230203-029)’,received by H.Z.Wang.
文摘Pitting corrosion is harmful during bridge construction,which will lead to uneven roughness of steel surfaces and reduce the thickness of steel.Hence,the effect of pitting corrosion on the mechanical properties of cold-formed thin-walled steel stub columns is studied,and the empirical formulas are established through regression fitting to predict the ultimate load of web and flange under pitting corrosion.In detail,the failure modes and load-displacement curves of specimens with different locations,area ratios,and depths are obtained through a large number of non-linear finite element analysis.As for the specimens with pitting corrosion on the web,all the specimens are subject to local buckling failure,and the failure mode will not change with pitting corrosion,but the failure location will change with pitting corrosion location;the size,location,and area ratio of pitting corrosion have little influence on the ultimate load of cold-formed thin-walled steel short columns,but the loss rate of pitting corrosion section area has a greater impact on the ultimate bearing capacity.As for the specimen with flange pitting corrosion,the location and area ratio of pitting corrosion have less influence on the ultimate load of cold-formed thin-walled steel short columns,and the section area loss rate has greater influence on the ultimate bearing capacity;the impact of web pitting corrosion on the ultimate load is greater than that of flange pitting corrosion under the same condition of pitting corrosion section area.The prediction formulas of limit load which are suitable for pitting corrosion of web and flange are established,which can provide a reference for performance evaluation of corroded cold-formed thin-walled steel.
基金co-supported by the National Key Research and Development Program of China(No. 2021YFB3301504)the National Natural Science Foundation of China (Nos. 62072415, 62036010, 42301526, 62372416 and 62472389)the National Natural Science Foundation of Henan Province, China (No. 242300421215)
文摘Accurate recognition of flight deck operations for carrier-based aircraft, based on operation trajectories, is critical for optimizing carrier-based aircraft performance. This recognition involves understanding short-term and long-term spatial collaborative relationships among support agents and positions from long spatial–temporal trajectories. While the existing methods excel at recognizing collaborative behaviors from short trajectories, they often struggle with long spatial–temporal trajectories. To address this challenge, this paper introduces a dynamic graph method to enhance flight deck operation recognition. First, spatial–temporal collaborative relationships are modeled as a dynamic graph. Second, a discretized and compressed method is proposed to assign values to the states of this dynamic graph. To extract features that represent diverse collaborative relationships among agents and account for the duration of these relationships, a biased random walk is then conducted. Subsequently, the Swin Transformer is employed to comprehend spatial–temporal collaborative relationships, and a fully connected layer is applied to deck operation recognition. Finally, to address the scarcity of real datasets, a simulation pipeline is introduced to generate deck operations in virtual flight deck scenarios. Experimental results on the simulation dataset demonstrate the superior performance of the proposed method.
基金supported by the Chongqing Municipal Talent Plan Project(cstc2024ycjh-bgzxm0186).
文摘The impact of longitudinal stiffener configurations on the structural performance of orthotropic steel bridge decks(OSD)was systematically investigated,with emphasis on U-shaped,T-shaped,and rectangular ribs.Finite element analysis was employed to evaluate deformation and stress distribution under three critical loading scenarios:vertical uniformload,vertical eccentric load,and lateral uniformload.Equivalentmodels ensuring identical steel usage,moment of inertia,and centroid alignment were established to compare five stiffener configurations.Results demonstrate that U-rib configurations exhibit superior performance in controlling local displacements and minimizing stress concentrations.Under eccentric loading,U-ribs significantly reduce deck displacement andmitigate stress fluctuations at critical junctions compared to alternative stiffeners.Stability analysis further reveals that U-ribs achieve stability coefficients substantially higher than open-section alternatives,particularly excelling under lateral loading due to enhanced torsional rigidity.Parametric optimization identifies key geometric thresholds where U-rib thickness exceeding 6 mm yields diminishing returns in stress reduction and stability enhancement,while deck flange thickness beyond 16 mm provides marginal improvements in displacement control despite increased material usage.An optimized design combining 6-mm U-ribs with 16-mm deck flanges is proposed,balancing structural efficiency with stringent deformation requirements for high-speed rail bridges.These findings provide foundational insights for optimizing stiffener selection and enhancing the longevity of orthotropic steel bridge decks in heavy-load applications.
基金Projects(51925808,52078504,51822803) supported by the National Natural Science Foundation of ChinaProject(2022JJ10082) supported by the Natural Science Foundation of Hunan Province,China+1 种基金Project(N2022Z004) supported by the Research on Technology Development Trend and Key Common Problems in Railway,ChinaProject(Xplorer Prize 2021) supported by the Tencent Foundation,China。
文摘Installing the splitter plates is a passive aerodynamic solution for eliminating vortex-induced vibration (VIV). However, the influences of splitter plates on the VIV and aerostatic performances are more complicated due to aerodynamic interference between highway and railway decks. To study the effects of splitter plates, wind tunnel experiments for measuring VIV and aerostatic forces of twin decks under two opposite flow directions were conducted, while the surrounding flow and wind pressure of static twin decks with and without splitter plates are numerically simulated. The results showed that the incoming flow direction affects the VIV response and aerostatic coefficients. The highway deck has poor vertical and torsional VIV, and the VIV region and amplitude are different under different directions. While the railway deck only has vertical VIV when located upstream. The splitter plates can impede the process of vortex generation, shedding and impinging at the gap between twin deck, and significantly reducing the surface fluctuating pressure coefficient, thus effectively suppressing the VIV of twin decks. While, the splitter plates hurt the upstream deck regarding static wind stability and have little effect on the downstream deck. The splitter plates of appropriate width are recommended to improve VIV performances in twin parallel bridges.
文摘Based on four-year field inspection and investigation on deck pavement of mastic asphalt on Jiangyin Bridge, cracking causes of mastic asphalt are studied. Cracks of deck pavement are summarized on crack length and width to get a clear view of their propagations. Traffic surveys including traffic volume, axle load and vehicle speed were also conducted to assess their influences. Samples taken on-site were tested with pulling-out test and fatigue test to benchmark their properties. According to the inspection and tests results, it is concluded that the cracks are induced by rutting and fatigue. Lack of fatigue resistance, not well bonded to the steel deck and insufficient high temperature stability are supposed to be the main reasons as well as high density of low speed, excessively overloaded trucks.
基金The National Natural Science Foundation of China(No50578038)
文摘A model for predicting the interface behavior of epoxy asphalt and steel composite beam under negative bending is developed incorporating partial interaction theory. Interfacial slips between the steel deck and the epoxy asphalt surfacing are included in the model with a new parameter of membrane stiffness. A series of analytical equations based on this model are derived to calculate slip and strain at the interface. Also, a numerical procedure for calculating the load responses of simply supported composite beams with concentrated force at the mid-span is established and verified with two samples. Characters of slip and strain at the interface, sensitivities of tensile stress and interface shear stress with material parameters are studied. It can be concluded that interfacial effects decrease the bending stiffness of the composite; hard and stiff bonding material is better for asphalt surfacing layer working at normal to low temperatures, and the damage of the asphalt surfacing layer will be accelerated with the damage accumulation of the bonding coat.
文摘To analyze the stress state of steel orthotropic deck pavement and provide reference for the design of the overlay, the inner stress state and strain distribution of surfacing under the load of the deformation of the whole bridge structure and tyre load are analyzed by the finite element method of submodeling. Influence of surfacing modulus on the strain state of the overlay is analyzed for the purpose of the optimal design of the overlay structure. Analysis results show that the deformation of the whole bridge structure has no evident influence on the stress state of the overlay. The key factor of the overlay design is the transverse tensile strain in the overlay above the upper edge of web plate of rib. The stress state of the overlay is influenced evidently by the modulus of rigidity transform overlay. And the stress state of the overlay can be optimized and lowered by increasing the modulus and thickness of rigidity transform overlay, The fatigue test has been done to evaluate the fatigue performance and modulus of different deck pavement materials such as epoxy asphalt, SBS modified asphalt, rosphalt asphalt which can provide reference for deck pavement structure design.